research centers


Search results: Found 130

Listing 1 - 10 of 130 << page
of 13
>>
Sort by

Article
Behavior of Short Reinforced Porcelinite Concrete Columns Under Concentric Loads
تصرف الأعمدة الخرسانیة المسلحة القصیرة المصنوعة من ركام البورسلینایت تحت الاحمال المركزية

Authors: Kaiss F. Sarsam --- Ihsan A. S. Al-Shaarbaf --- Mustafa S. Shuber
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2009 Volume: 27 Issue: 6 Pages: 1219-1233
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

This study presents on experimental method to investigate the behavior ofreinforced porcelinite concrete columns subjected to concentric load. The experimentalwork includes investigation of ten lightweight concrete columns with square crosssection 190×190mm and 1000mm in length subjected to concentric load to assess theeffect of the amount of longitudinal steel reinforcement, lateral tie reinforcement andgrade of concrete. From the experimental observation it was found that the porceliniteaggregate is a good structural material to produce lightweight concrete columns. It isnoted from tested columns that keeping the amount of the longitudinal steel ratioconstant, the increase in the amount of transverse steel to about four times (bydecreasing the spacing to about a quarter according to the ACI-Code (318M-05)) gave asignificant influence on column post-cracking behavior. The improvements in thecolumn due to higher value of confinement include: (i) less brittle behavior; (ii)significantly less damage to the concrete core; (iii) 12% increase in column loadcarrying capacity. Also, A modified formula for column capacity is proposed to takeinto account the influence of spacing of ties (effect of confinement).

تقدم هذه الدراسة بحثا عمليا لدراسة سلوك الاعمدة الخرسانية خفيفة الوزن التي تحوي علىركام البورسلنايت تحت تاثير الاحمال المحورية . يتضمن الجزء المختبري فحص عشر ة أعمدة خفيفة190 ملم) وبطول ( 1000 ملم) والمعرضة الى احمال محورية × الوزن مربعة المقطع بابعاد ( 190ومقاومة الخرسانة للانضغاط . (lateral) لتقدير تاثير كمية الحديد الطولي وكمية الحديد العرضييمكن الملاحظة من خلال التجارب المختبرية (العملية) بان مادة ركام البورسل نايت جيدة انشائيا وملائمةلتنتج خرسانة خفيفة الوزن وكذلك يمكن الملاحظة عند الحفاظ على كمية الحديد الطولي ثابتة فانالزيادة في الحديد العرضي اربعة أضعاف حسب ماتحدده متطلبات الكود الامريكي لسنة 2005 يؤثرتاثيرا كبيرا على تصرف العمود في مرحلة ما بعد التشقق . ان تحسين اداء وكفاءة العمود من خلالاستخدام نسبة حديد عرضي اكبر يؤدي الى : أ-زيادة في المطيلية . ب-اقل تضررا لقلب العمودالخرساني (الجزء الخرساني من العمود والمحصور داخل الحديد العرضي). ج-زيادة 12 % للتحملالاقصى للعمود.كذلك تم تطوير معادلة تجريبية لحساب الحمل تاخذ بنظر الاعتبار تاثير الحديد العرضي.

Keywords

Porcelinite --- R.C. --- Columns


Article
Quasi Cancellation R-Modules
موديولات الحذف الكاذب

Authors: Nada Khalid Aldaban ندى خالد الدبان --- Mahera Rabia Alnima مهيرة ربيع النعمة
Journal: Journal of university of Anbar for Pure science مجلة جامعة الانبار للعلوم الصرفة ISSN: ISSN: 19918941 Year: 2015 Volume: 9 Issue: 2 Pages: 67-73
Publisher: University of Anbar جامعة الانبار

Loading...
Loading...
Abstract

Let R be a commutative ring with identity, and let M be a unitary left R-module. In this work, we introduce quasi cancellation R-module (weakly quasi cancellation R-module) concept as a generalization of cancellation R-module (weakly cancellation R-module) concept we generalize some properties of cancellation (weakly cancellation) R-modules to quasi cancellation (weakly quasi cancellation) R-modules. Furthermore, we give some conditions under which R-module M is quasi cancellation R-module.

لتكن R حلقة ابدالية ذات عنصر محايد، وليكن M موديول احادي ايسر معرف على الحلقة R . أن الهدف من هذا البحث هو تعميم مفهوم موديولات الحذف إلى موديولات حذف كاذبة كما تم تعميم مفهوم موديولات الحذف الضعيفة إلى موديولات الحذف الكاذبة الضعيفة. كما درسنا العلاقة بينهما وكيف يمكن الحصول على موديولات الحذف الكاذبة من موديولات الحذف وبالعكس وكذلك قام البحث بتعميم بعض خصائص موديولات الحذف على موديولات الحذف الكاذبة وذلك بوضع بعض الشروط الضرورية .


Article
On coc-r-compact spaces
حول الفضاءات coc-r-compact

Loading...
Loading...
Abstract

In this.work, We will study a.new class of popularizer open.sets called.coc-r-open sets and we will study its properties too, also we will study coc-r-compact, I-Compact space and the relationship between them, finally we have to get some results that show the relationship between these spaces through some of the theorems obtained by using coc-r-open sets.

في ورقة العمل هذه، سوف ندرس مجموعه جديدة من المجموعات مفتوحة تسمى مجموعة coc-r-open وسندرس أيضا خصائصها، كما سندرس coc-r-compact, I-Compact والعلاقة بينهما، حيث حصلنا على بعض النتائج التي تظهر العلاقة بين تلك الفضــاءات من خلال بعض النظريــات التي تم الحصول عليهــا باستخــدام مجموعــات coc-r-open.


Article
Experimental Perspective Assessments for a Proper Refrigerant Alternative to R-22 in a Window-Type Air Conditioning Unit
وجهة نظر لتقييم تجريبي لاستخدام مائع تثليج مناسب بديلاً لفريون-22 في وحدة تبريد هواء من النوع الشباكي

Authors: Ameera Yaseen Salim --- Ali Hussain Tarrad
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2009 Volume: 15 Issue: 2 Pages: 3756-3775
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

The present research is concerned with the future phase-out of halocarbon types of refrigerants used in the vapor compression refrigeration systems. A window-type air conditioner is selected for the tests to be conducted with two different refrigerants. It is well known that these cooling units are wide spread in their applications and are circulating R-22 as a refrigerant. It is intended to replace this type of refrigerant by another type which is considered to be as environmental friendly refrigerant for smooth operation. The refrigerant selected for this object was R-407C for its favorable thermal properties and acceptable pressure and temperature ranges. The effect of replacing this refrigerant as a substitute on the performance of the cooling unit was studied. The performance characteristics comprise of cooling capacity (Q evap ), power consumed by the compressor (W ̇_cons ) and the coefficient of performance (COP) of the air conditioning unit were obtained. The results showed that the pressure ratio of the R-407C for a proper operation was higher than that of the R-22 by a mean value of (13) %. The power consumed per ton of refrigeration by the unit when circulating R-407C was about (19) % greater than the R-22 values for the whole range of tests. Further, the experimental work has revealed that the actual COP of the unit was reduced by (17) % when circulating the alternative R-407C for the test conditions. The results also showed that this alternative for the present refrigerant with existing cooling unit requires the attention to the mass flow rate of refrigerant circulated and the pressure and temperature ranges throughout the system.

يهتم البحث الحالي بالإيقاف المستقبلي لاستخدام موائع التثليج الهالوكاربونية والتي يدخل في تركيبها الكيميائي الغازات الهالوجينية في منظومات التبريد ألإنضغاطية. لقد تم اختيار مكيف هواء من النوع الشباكي لإجراء التجارب العملية ولمائعي تثليج مختلفين. ومن المعروف إن هذه الوحدات واسعة الانتشار بالاستخدام وتعمل بواسطة تدوير (Freon-22) كوسيط للتبريد. لقد كانت الرغبة باستخدام مائع تثليج قليل التأثير السلبي على البيئة وله القابلية على تشغيل الوحدة بصورة طبيعية. لقد وقع الاختيار على (Freon-407C) كبديل مناسب خلال البحث الحالي نظراً لما يتميز به من مواصفات حرارية مفضلة وله القابلية للعمل بمديات مقبولة من حيث درجة الحرارة والضغط. تم دراسة التأثير الناتج من استخدام هذا المائع على أداء وحدة تكييف الهواء موضوع البحث. إن دراسة الأداء لوحدة التبريد تتضمن حساب كلاً من حمل التبريد (Q evap )’ الطاقة المستهلكة من قبل الضاغط (W ̇_cons ) ومعامل الأداء (COP).لقد بينت النتائج لهذه الدراسة إن نسبة الضغط بين جانب الدفع والسحب للضاغط لمائع التثليج (Freon-407C) ولعمل مستقر ومناسب للوحدة كان أعلى مما عليه في حالة استخدام (Freon-22) كمائع للتثليج وبمعدل ( %13). الطاقة المستهلكة لكل طن تثليج باستخدام (Freon-407C) كانت أعلى بمقدار (19 %) من مثيلتها لحالة (Freon-22) ولكل مدى التجارب الحالية. بالإضافة لذلك فان النتائج العملية قد بينت بان معامل الأداء لوحدة التكييف قل بمقدار (17 %) عند تدوير (Freon-407C) عبر منظومة التبريد. كما وبينت الدراسة الحالية بان البديل المقترح عند استخدامه في منظومات التبريد يتطلب الاهتمام بمعدل التدفق ومديات الضغط التشغيلي ودرجة الحرارة عبر المنظومة.


Article
Sub-Cooling Auxiliary System for Performance Enhancement of Main Refrigeration System
استخدام منظومة تبريد مفرط ثانويه لتحسين اداء منظومات التبريد الرئيسية

Authors: Mustafa W. Hamadalla --- Fawziea M. Hussien --- Ahmed J. Hamad
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2015 Volume: 33 Issue: 8 Part (A) Engineering Pages: 1798-1812
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

In presentwork, a sub-coolingauxiliary system is integrated with vapour compression refrigeration system to predict the performance characteristics and energy saving of the system. An experimental investigation was performed to determine the performance parameters at various operating conditions using two types of refrigerants, R-134a and zeotropic mixed refrigerant R-404A.Investigating the results hasshowed that, the enhancement in performance of the refrigeration system with sub-cooling circuit compared with that for system without sub-cooling for R-134a was about 5% increase in RE, 14% optimization in COPand 2.8% energy saving for different thermal loads applied on the evaporator.While for R-404A, the increase in RE was 4%, the optimization in COP was about 13% and 3.7%energy saving. There is a significant improvement in the performance of the system with R-404A compared with that forR-134a at the same operating conditions.

تتضمن الدراسة الحالية استخدام منظومة تبريد انضغاطية ملحق بها منظومة تبريد مفرط ثانويه لدراسة خصائص الاداء ومقدار التوفير بالطاقة للمنظومة. تم اجراء استقصاء تجريبي لحساب برامترات الاداء في ظروف تشغيل مختلفة باستخدام نوعين من وسائط التبريد, R-134aووسيط مختلط زيوتروبي R-404A عندما تشغل المنظومة بدون ومع دورة تبريد مفرط ثانويه. تحليل النتائج قد أوضح بان مقدار زيادة الاداء للمنظومة مع دورة التبريد الثانويه كان بزيادة 5% في سعة التبريد و 14% زيادة في معامل الاداء ومقدار التوفير بالطاقة 2.8% لوسيط التبريدR-134a عند احمال حرارية مختلفه, بينما للوسيط R-404A كانت بحدود 4% و 13% و3.7%على التوالي. لوحظ وجود تحسن ملموس في اداء المنظومة عندما تعمل بوسيط التبريد R-404A مقارنة بالوسيطR-134a عند ظروف تشغيل متشابهة.


Article
EFFECT OF USING R-22, R404 AND R-407C ON PERFORMANCE OF AN AIR-CONDITIONING SYSTEM
على اداء منظومة التثليجR-22, R404 AND R-407C تاثير استخدام

Author: Abeer Hashim Falih*
Journal: Journal of Engineering and Sustainable Development مجلة الهندسة والتنمية المستدامة ISSN: 25200917 Year: 2018 Volume: 22 Issue: 5 Pages: 200-214
Publisher: Al-Mustansyriah University الجامعة المستنصرية

Loading...
Loading...
Abstract

Due to the environment depletion, replacing chlorofluorocarbons in refrigeration industry was an important problem. In the experimental study a (1.0 TR) vapor compression system were used with original working fluid of R-22 and compared to alternatives refrigerant R-407C and R-22. The effects of the main parameters of performance analysis such as refrigerant type, compressor pressure ratio, outlet air evaporative temperature, coefficient of performance were investigated for various ambient temperatures above 50 ºC. The results showed that the compressor ratio of system using R404 and R-407C is more than the compressor ratio of system using R22 by 2% and 4% respectively. Also, the outlet air evaporative temperature of system using the alternative refrigerant R-22 is more than the outlet air evaporative temperature with system using R-407C and R-404 by 8% and 5% respectively. The coefficient of performance of R-407C was measured with the same reciprocating compressor that was supplied with the R-22 system. It could be concluded that there is a decrease of 8% in system COP as friendly environment R407C compared with system using R-22 and a decrease of 12% in system COP when using R-404. However; the result showed that R407C have thermodynamic performance similar to R-22. Engineering Equation Solver (EES) software is used for draw (p-h) diagram for the cycle


Article
Synthesis and Characterization of Tripodal Tetradentate Ligand Type NS3 and its Complexes with Re(V), Ni(II), Cu(II), Zn(II), Cd(II), and Hg(II)
تحضير وتشخيص ليكاند رباعي السن نوع NS3 ومعقداته مع ايوناتRe(V)، Ni(II)، Cu(II)، Zn(II)، Cd(II)، و Hg(II)Re(V)&#1548; Ni(II)&#1548; Cu(II)&#1548; Zn(II)&#1548; Cd(II)&#1548; &#1608; Hg(II)

Authors: Kanan M. Tawfiq كنعان محمود توفيق --- Mohamad J. Al-Jeboori محمد جابر الجبوري --- Matheel D. Al-Sabti مثيل ضايف السبتي
Journal: Baghdad Science Journal مجلة بغداد للعلوم ISSN: 20788665 24117986 Year: 2009 Volume: 6 Issue: 1 Pages: 173-187
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

This work represents the preparation of the starting material, 3-chloro-2-oxo-1,4-dithiacyclohexane (S) using a new method. This material was reacted with, 4-phenylthiosemicarbazide to give (H3NS3) as a tetradentate ligand H3L. New complex of rhenium (V) with this ligand of the formula [ReO(L)] was prepared. New complexes of the general formula [M(HL)] of this ligand when reacted with some metal ions where: M = Ni(II), Cu(II), Cd(II), Zn(II), Hg(II) have been reported.The ligand and the complexes were characterized by infrared, ultraviolet–visible, mass, 1H nuclear magnetic resonance and atomic absorption spectroscopic techniques and by (HPLC), elemental analysis, and electrical conductivity. The proposed structure for H3L with Re (V) is square pyramidal, while Ni(II) complex was square planar geometry, and with the rest of metal ions are distorted tetrahedral.

تضمن البحث تحضير المادة الأولية 3-كلورو-2-اوكسو-1،4-ثنائي ثايا سايكلوهكسان (S) بطريقة جديدة. تم مفاعلة هذه المادة مع 4-فنيل ثايو سميكاربزايد للحصول على ليكاند رباعي السن (H3L) نوع (H3NS3). كذلك تضمن البحث تحضير معقد جديد لهذا الليكاند مع أيون الرينيوم الخماسي بالصيغة [ReO(L)]. كذلك تم تحضير معقدات جديدة بالصيغة العامة [M(HL)] لهذا الليكاند مع أيونات Ni(II)، Cu(II)، Zn(II)، Cd(II)، و Hg(II).شخص الليكاند والمعقدات بواسطة طيف الأشعة تحت الحمراء، طيف الأشعة فوق البنفسجية والمرئية، طيف الكتلة، طيف الرنين النووي المغناطيسي، طيف الامتصاص الذري، تقنية (HPLC)، التحليل الكمي الدقيق للعناصر، وكذلك قياس التوصيلية الكهربائية. بينت الدراسات ان الشكل الفراغي المتوقع لمعقد الرينيوم الخماسي مع H3L هو هرم مربع القاعدة، مع Ni(II) والأيونات الأخرى مربع مستو.

Keywords

Tetradentate ligand --- NS3 --- Re --- r


Article
Measurements of HbA1c for Patients with Diabetes Mellitus and Foot Ulceration

Authors: Aqeel S. Mahmood --- Mayada M. Moustafa --- Mohammed A.Taher محمد عباس طاهر
Journal: Iraqi Journal of Pharmaceutical Sciences المجلة العراقية للعلوم الصيدلانية ISSN: 16833597 Year: 2011 Volume: 20 Issue: 1 Pages: 19-24
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

People with diabetes can develop different foot problems. In the blood stream glucose reacts with hemoglobin to make a glycosylated hemoglobin molecule called hemoglobin A1c or HbA1c, the more glucose in the blood the more hemoglobin A1c will be present in the blood. The HbAlc test is currently one of the best ways to check diabetes to be under control. The aim of study is to compare between the blood investigations which includes the fasting blood sugar and HbAlC (glycosylated hemoglobin), and to evaluate the benefit of HbAlc (measurement for diabetic patients with foot ulcer, to be a good indicator for controlling blood glucose). Sixty patients with type2 diabetes mellitus from the outpatient clinic of Baghdad Teaching Hospital, Medical City over the period from Nov. 2006 to Nov. 2008, were included in the study. Follow up was done only to 30 patients with diabetic foot ulcer. Twenty (66.66%) were males and 10(33.33%) were females their age range from (23-75) years (mean age of 52years), and 21 normal subjects as control. A (Glycohemoglobin HbAl-Test/fast lon-Exchange Resin Separation Method) kit was used. The data finding that there is a greater association between HbAlc level and foot ulceration healing. There is a relationship between the age of the patients and the HbAlc level. The patients who used (Glibenclamide+Metformin) have the lower range of HbAlC, while those who use (Metformin) have the higher level of HbAlc. HbAlc (glycosylated hemoglobin) is most accurate test to determine actual reading over the past 2-3 months, and to evaluating the risk of glycemic damage to the tissues. So, we recommend the HbAlc testing, but it can't be used to monitor day-to-day blood glucose concentration because it's not influenced by fluctuation in blood concentration.

المصابين بداء السكري من الممكن ان تتطور لديهم الحالة المرضية الى الاصابة بتقرحات في القدم . في مجرى الدم جزيئاتوكلما كانت كمية الكلوكوز HbA1c او A1c الكلوكوز تلتصق بالهيموغلوبين لتكوين كلايكوسيلايتد هيموغلوبين وتدعى هيموغلوبينواحد من HbA1c اكثر . لقد وجد في الاونة الاخيرة بان الاستعانة باختبار مستوى A1c في الدم اكثر كلما كانت كمية الهيموغلوبينافضل الطرق للتحقق من مرض السكري الواقع تحت السيطرة . الغاية من هذه الدراسة للمقارنة بين الطرق المتبعة والمعتمد عليها فيالسيطرة على نسبة السكر لدى المرضى السكري من النوع الثاني ٬ مثل اختبار السكري في حالة الصيام ومقارنته باختبار مستوىالكلايكوسيلايتد هيموغلوبين . اجريت الدراسة على 60 شخص مصابين بمرض السكري من النوع الثاني واستمرت الدراسة على 30. (%33.33) 66.66 %) والاناث 10 ) 75 سنة وكان عدد الذكور 20 شخصمنهم مصاب بتقرحات في القدم وبمعدل عمري من 23كما استعين ب 21 شخص سليم غير مصاب بداء السكري وليس لديه تقرحات (مجموعة سيطرة) وقد وجدنا نتيجة هذه الدراسة بانوشفاء تقرحات القدم. كما وجدنا هناك علاقة بين عمر HbA1c النتائج المستحصل عليها تفيد بان هناك علاقة كبيرة بين مستوىالمريض ونسبة الكلايكوسيلايتد هيموغلوبين في الدم ٬ كذلك وجدنا من خلال هذه الدراسة بان المرضى المعالجين بمجموعة الادويةالمخفضة للسكر (ميتفورمين + كليبينكلامايد) قد انخفض مستوى الكلايكوسيلايتد هيموغلوبين اكثر من مجموعة المرضى الذيناستعملوا (الميتفورمين) فقط حيث كان مستوى الكلايكوسيلايتد هيموغلوبين اعلى . تستنتج الدراسة بان الكلايكوسيلايتد هيموغلوبين هو3 اشهر سابقة ولتقدير الخطورة التي يتعرض لها المصاب . لذلك نوصي باستعمال – اصح اختبار لتعيين القيمة الحقيقية للسكر بمدة 2اختبار الكلايكوسيلايتد هيموغلوبين حتى وان كان لايعطينا قيمة السكر المتغيرة يوميا.


Article
Numerical and experimental investigation on the performance of the capillary tube using R-134a and R-600a
التحليل العملي والعددي على الجريان الاديباتي لموائع التثليج البديلة في الانبوب الشعري

Authors: Qasim Saleh Mehdi قاسم صالح مهدي --- Baydaa Jaber Nabhan بيداء جابر نبهان
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2012 Volume: 18 Issue: 12 Pages: 1403-1420
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

In this paper, isobutane (R-600a) is used as a suitable substitute for (R-134a) when changing the length of capillary tube. And the experimental data on capillary tube are obtained under different conditions such as (subcooling and ambient temperatures) on domestic refrigerator (9ft3 size), this data shows that (R-600a) a suitable substitute for (R134a) .The test presented a model for a steady state, two-phase flow in capillary tube for vapour compression system .The numerical model depends on conservation equations (mass, energy and momentum) as wall as the equation of state for refrigerant. The solution methodology was implemented by using finite difference techniques. The system results indicate that it is possible to change the refrigeration system using (R-134a) by shorter capillary tube length about (28.6%) when using (R-600a) .The theoretical results for different variables such as(subcooling and ambient temperatures) showed a good agreement with the "ASHRAE" tables and experimental results.

تم في هذا البحث استخدام مائع التثليج R-600a كبديل لمائع التثليج R-134aمن خلال تغير طول الأنبوب الشعري ,حيث تم الحصول على بيانات عملية لأنبوب شعري تحت مختلف الظروف مثل (درجة التبريد الإضافي ودرجة حرارة المحيط ) لثلاجة منزلية سعة (9 قدم3) والتي أوضحت بان R-600a هو مائع التثليج المناسب ل (R-134a). قدم هذا الاختبار الحالة المستقرة للجريان الثنائي للمائع داخل الأنبوب الشعري في منظومة التثليج الانضغاطية . اعتمدت النمذجة العددية على معادلات حفظ (الكتلة , الطاقة , الزخم ) بالإضافة إلى معادلة الحالة للمائع . منهجية الحل نفذت باستخدام تقنية الفروق المحددة في حل المعادلات . ونتائج المنظومة تشير إلى إمكانية تغير منظومة التثليج المستخدمة R-134a بواسطة تقصير طول الأنبوب الشعري بحوالي (28.6%) عندما نستخدم R-600a.النتائج النظرية لمتغيرات مختلفة مثل (درجة التبريد الإضافي ودرجة حرارة المحيط ) تشير إلى تطابق جيد مع جداول ASHRAE"" وكذلك مع النتائج العملية لهذا البحث.


Article
Generalized Amply Cofinitely Supplemented Modules
المقاسات المكملة المنتهية المضاده باسهاب معمم

Author: Alaa Abbas Elewi ألأء عباس عليوي
Journal: Iraqi Journal of Science المجلة العراقية للعلوم ISSN: 00672904/23121637 Year: 2013 Volume: 54 Issue: 3 Pages: 706-708
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

Let R be an associative ring with identity. An R-module M is called generalized amply cofinitely supplemented module if every cofinite submodule of M has an ample generalized supplement in M. In this paper we proved some new results about this conc- ept.

لتكن R حلقة تجميعية تمتلك عنصر محايد. المقاس M من النمط Rيدعى مقاس مكمل منتهي مضاد باسهاب معمم اذا كان لكل مقاس جزئي منتهي مضاد من M يمتلك تعميم مكمل باسهاب في M. في هذا لبحث قدمنا نتائج جديدة حول هذا النوع من المقاسات.

Listing 1 - 10 of 130 << page
of 13
>>
Sort by
Narrow your search

Resource type

article (130)


Language

English (95)

Arabic (17)

Arabic and English (16)


Year
From To Submit

2019 (5)

2018 (12)

2017 (12)

2016 (18)

2015 (15)

More...