Sub-Cooling Auxiliary System for Performance Enhancement of Main Refrigeration System
استخدام منظومة تبريد مفرط ثانويه لتحسين اداء منظومات التبريد الرئيسية

Authors: Mustafa W. Hamadalla --- Fawziea M. Hussien --- Ahmed J. Hamad
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2015 Volume: 33 Issue: 8 Part (A) Engineering Pages: 1798-1812
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

In presentwork, a sub-coolingauxiliary system is integrated with vapour compression refrigeration system to predict the performance characteristics and energy saving of the system. An experimental investigation was performed to determine the performance parameters at various operating conditions using two types of refrigerants, R-134a and zeotropic mixed refrigerant R-404A.Investigating the results hasshowed that, the enhancement in performance of the refrigeration system with sub-cooling circuit compared with that for system without sub-cooling for R-134a was about 5% increase in RE, 14% optimization in COPand 2.8% energy saving for different thermal loads applied on the evaporator.While for R-404A, the increase in RE was 4%, the optimization in COP was about 13% and 3.7%energy saving. There is a significant improvement in the performance of the system with R-404A compared with that forR-134a at the same operating conditions.

تتضمن الدراسة الحالية استخدام منظومة تبريد انضغاطية ملحق بها منظومة تبريد مفرط ثانويه لدراسة خصائص الاداء ومقدار التوفير بالطاقة للمنظومة. تم اجراء استقصاء تجريبي لحساب برامترات الاداء في ظروف تشغيل مختلفة باستخدام نوعين من وسائط التبريد, R-134aووسيط مختلط زيوتروبي R-404A عندما تشغل المنظومة بدون ومع دورة تبريد مفرط ثانويه. تحليل النتائج قد أوضح بان مقدار زيادة الاداء للمنظومة مع دورة التبريد الثانويه كان بزيادة 5% في سعة التبريد و 14% زيادة في معامل الاداء ومقدار التوفير بالطاقة 2.8% لوسيط التبريدR-134a عند احمال حرارية مختلفه, بينما للوسيط R-404A كانت بحدود 4% و 13% و3.7%على التوالي. لوحظ وجود تحسن ملموس في اداء المنظومة عندما تعمل بوسيط التبريد R-404A مقارنة بالوسيطR-134a عند ظروف تشغيل متشابهة.


Article
Numerical and experimental investigation on the performance of the capillary tube using R-134a and R-600a
التحليل العملي والعددي على الجريان الاديباتي لموائع التثليج البديلة في الانبوب الشعري

Authors: Qasim Saleh Mehdi قاسم صالح مهدي --- Baydaa Jaber Nabhan بيداء جابر نبهان
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2012 Volume: 18 Issue: 12 Pages: 1403-1420
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

In this paper, isobutane (R-600a) is used as a suitable substitute for (R-134a) when changing the length of capillary tube. And the experimental data on capillary tube are obtained under different conditions such as (subcooling and ambient temperatures) on domestic refrigerator (9ft3 size), this data shows that (R-600a) a suitable substitute for (R134a) .The test presented a model for a steady state, two-phase flow in capillary tube for vapour compression system .The numerical model depends on conservation equations (mass, energy and momentum) as wall as the equation of state for refrigerant. The solution methodology was implemented by using finite difference techniques. The system results indicate that it is possible to change the refrigeration system using (R-134a) by shorter capillary tube length about (28.6%) when using (R-600a) .The theoretical results for different variables such as(subcooling and ambient temperatures) showed a good agreement with the "ASHRAE" tables and experimental results.

تم في هذا البحث استخدام مائع التثليج R-600a كبديل لمائع التثليج R-134aمن خلال تغير طول الأنبوب الشعري ,حيث تم الحصول على بيانات عملية لأنبوب شعري تحت مختلف الظروف مثل (درجة التبريد الإضافي ودرجة حرارة المحيط ) لثلاجة منزلية سعة (9 قدم3) والتي أوضحت بان R-600a هو مائع التثليج المناسب ل (R-134a). قدم هذا الاختبار الحالة المستقرة للجريان الثنائي للمائع داخل الأنبوب الشعري في منظومة التثليج الانضغاطية . اعتمدت النمذجة العددية على معادلات حفظ (الكتلة , الطاقة , الزخم ) بالإضافة إلى معادلة الحالة للمائع . منهجية الحل نفذت باستخدام تقنية الفروق المحددة في حل المعادلات . ونتائج المنظومة تشير إلى إمكانية تغير منظومة التثليج المستخدمة R-134a بواسطة تقصير طول الأنبوب الشعري بحوالي (28.6%) عندما نستخدم R-600a.النتائج النظرية لمتغيرات مختلفة مثل (درجة التبريد الإضافي ودرجة حرارة المحيط ) تشير إلى تطابق جيد مع جداول ASHRAE"" وكذلك مع النتائج العملية لهذا البحث.