Article
Experimental Investigation Effect of Capillary Tube Number on Window Type Air Conditioning Unit Performance
دراسة عملية لتأثير عدد الأنابيب الشعرية على أداء مكييف هواء جداري

Author: Ali Khalid Shaker Al-Sayyab
Journal: journal of kerbala university مجلة جامعة كربلاء ISSN: 18130410 Year: 2018 Volume: 16 Issue: 1 Pages: 333-341
Publisher: Kerbala University جامعة كربلاء

Loading...
Loading...
Abstract

Capillary tubes are widely used in refrigerating and air conditioning units. It has no moving part however, a capillary tube is less expensive and generally performs nearly as well. In this work, the effect of capillary tube numbers on air conditioning system performance is studied for refrigerant R22. The study was adopted with the five capillary tubes at same diameter of 2.2 mm and length of 0.6 m. The experimental work shows that, the air conditioning operates with three capillary tubes gives highest COP from other of the same diameter with 14% increasing from base case of two capillary tubes, where the performance of the air conditioning that operates with one capillary tube gives the lowest COP from other.

تستخدم ألأنابيب الشعرية على نطاق واسع في وحدات التبريد وتكييف الهواء. تمتاز بعدم وجود اي جزء متحرك ويعتبر ألأنبوب الشعري أقل تكلفة .في هذا العمل، تم دراسة تأثير عدد ألأنابيب الشعرية على أداء منظومة تكييف هواء جدارية تعمل بالمائع R22. واعتمدت في هذه الدراسة خمسة أنابيب شعرية ذات قطر 2.2 ملم وطول 0.6 متر. اظهر الجانب العملي أن مكييف الهواء الذي يعمل مع ثلاثة أنابيب شعرية يعطي أعلى معامل اداء من غيرها لنفس القطر مع زيادة 14٪ عن حالة الاساسية (انبوبين شعريين )، كذلك مكييف الهواء الذي يعمل مع أنبوب شعري واحد يعطي أدنى معامل اداء.


Article
A Comparative Study of the Performance of Finned Tube Air Cooled Condenser with Refrigerants R22 and R407C

Authors: Ahmed Abdulnabi Imran --- Falah Fakhir Hatem --- Faeza Mehdi Hadi
Journal: AL-NAHRAIN JOURNAL FOR ENGINEERING SCIENCES مجلة النهرين للعلوم الهندسية ISSN: 25219154 / eISSN 25219162 Year: 2017 Volume: 20 Issue: 3 Pages: 657-665
Publisher: Al-Nahrain University جامعة النهرين

Loading...
Loading...
Abstract

Mathematical and numerical study of finned tube air cooled condenser for air conditioning unit with two ton refrigeration capacity using R22 as a base fluid and R407C an alternative fluid was investigated. Different parameters were considered in this work, such as condensing pressure, ambient temperature and refrigerant mass flow. A comparison of performance between two condensers when using R22 and R407C were performed. A redesign the condenser operates with the R407C to operate with the same system that operates with R22. The result showed the same behavior for the two refrigerants, the condensers are possible to work with R407C for the same geometry and some modifications in the structure of heat exchange with the same air velocity. The proposed model was validated with the outputs from the test data given in literature papers, derived from air cooled condensers with different dimensions. The results exhibited an agreement with the experimental results with a percentage of compatibility ± 10%.

تم في هذا البحث دراسة عددية ورياضية لاداء مكثف ذو انابيب مزعنفة في وحدة تكييف هواء سعة اثنين طن تبريد تعمل بمائع التثليج R22 كمائع اساسي وR407C كمائع بديل. تمت دراست عدة متغيرات كضغط المكثف, ودرجة حرارة المحيط, ومعدل تدفق الكتلة لمائعي التثليج. عند مقارنة اداء المكثف عندما يعمل بمائعي التثليج R407C و R22 وجد انه يجب اعادة تصميم المكثف ليلائم العمل مع المائع R407C مع الابقاء على نفس اجزاء المنظومة الاخرى. اظهرت النتائج تشابه في سلوك مائعي التثليج لذا يمكن ان يعمل المكثف بمائع التثليج R407C بنفس الوحدة مع بعض التحسينات في تركيب المبادل الحراري ولنفس سرعة الهواء. تم مطابقة نتائج الانموذج المقترح مع النتائج العملية المنشورة في البحوث ولابعاد مختلفة , ووجد ان نسبة التوافق مع النتائج العملية لكمية الحرارة المطروحة في المكثف هي بحدود 10 % ± .