research centers


Search results: Found 8

Listing 1 - 8 of 8
Sort by

Article
A Technique of Computer-Simulated Dose Reduction for Conventional Chest Computed Tomography (CT)
تقنية الكومبيوتر لتقليل الجرعة الاشعاعية لمنطقة الصدر بواسطة جهاز المفراس

Author: Runak Tahr Ali د. روناك طاهرعلي
Journal: IRAQI JOURNALOF COMMUNITY MEDICINE المجلة العراقية لطب المجتمع ISSN: 16845382 Year: 2009 Volume: 22 Issue: 2 Pages: 105-111
Publisher: Al-Mustansyriah University الجامعة المستنصرية

Loading...
Loading...
Abstract

Abstract: Computed Tomography is a diagnostic imaging modality giving higher patient dose in comparison with other radiological procedures. The level of CT radiation dose is of concern to radiologists, medical physicists, government regulators, and the media. This review addresses this problem with particular reference to radiation dose in chest CT. Specifically it outlines the topics of measurement units used to quantify radiation exposure, factors affecting CT scanner dose efficiency, scanner settings that determine the administered radiation dose, and radiation dose reduction in chest CT.The Objective: Aim of this study is to determine minimal tube current (mAs) required for good image quality on conventional chest CT (Computed Tomography).Patients & Methods: Prospectively, 35 consecutive patients (mean weight, 65 kg; range, 38-92 kg) older than 45 undergoing conventional chest CT with standard technique (120 kVp, 400 mAs) had four additional sections imaged at reduced tube current (200, 140, 80, 20 mAs) at two levels (tracheal carina and left atrium). CT scans were evaluated in random order by two independent observers who were blinded to technical factors used. Results: The 400 mAs scan was considered the reference standard. When compared with the reference technique (400 mAs), the first and second (200 mAs and 140 mAs) reduction levels showed no significant difference (p > .05) in subjective image quality. A significant difference (p < .001) was seen at the third and fourth (80 mAs and 20 mAs) reduction levels. A two fold reduction in tube current (400-140 mAs) and resultant radiation dose did not cause a significant change in subjective image quality or in detection of lung abnormalities with conventional chest CT. One hundred forty milliampere-seconds is the minimal tube current required to provide good image quality in patients of average weight.CT is a diagnostic imaging modality giving higher patient dose in comparison with other radiological procedures. CT scan parameters have been adjusted with the aim of working towards optimization of image quality and patient dose. Conclusions: The effective dose of our population is (1.8 mSv) compared with UK, Crawly et al and Hughes et al have the same value.Key words: Radiation dose, CT scan& Reduction dose.

الملخص: جهاز المفراس هو لتشخيص الصوروتوضيحها من خلال جرعة اشعاعية مؤثرة,اذا قارناها مع اجهزة اخرى لتشخيص هذه العملية. ان مستوى الجرعة الاشعاعية يتعلق ب الاشعاعين والفيزياء الطبيةوالوسط. وفائدة استخدام الفحص الطبقى المبرمج هى من خلال استخدامها لتشخيص الامراض كما انها دليل برامج التدخل والعلاجية , هذه الفوائد لا تخلوا من المخاطر ولهذا فان توضيح هذه المخاطر وتقليلها ذو أهمية بالغة من خلال التحكم والابقاء على الجرع الاشعاعية فى مثل هذه الانواع من الفحوصات على أقل المستويات المقبولة وخصوصا بالنسبة للاطفال والبالغين من الشباب والذين هم أحيانا يستلمون جرع اشعاعية أكثر من اللازم للحصول على صور تشخيصية ذات معلومات واضحة . الهدف من هذه الدراسة هو ايجاد اقل زمن تيار للتعرض (mAs) مع وضوح الصورة بواسطة جهاز المفراس. وقد اختيرو 35 مريضا وكان معدل الوزني 65 كيلوغرام وبمدى ( 38-92) كيلوغرام وكان عمرهم اكبر من 45 سنة من خلال فحصهم بجهاز المفراس لمنطقة الصدر, وبتقنية معيارية ثابتة لزمن التعرض 400 mAs)) وبتقليل زمن التيار)20,80,140.200( mAs . زمن التيار للتعرض 400 mAs هو كمرجع معيارى ثابت , عند مقارنة زمن التيار مع الاول والثاني )140-200( mAs نرى ان هنالك معيارا غير معنويا P>0.05) ( لخلال الدقة للصورة. ولكن نرى معيارا معنويا P<0.001) ( لزمن تيار للتعرض الثالث والرابع )20-80) mAs وتقليل جرع الاشعاعية .اذا زمن تيار للتعرض 140 -400 mAs لا نرى غموضا للصورة التشخيصية او عدم وضوح منقة المطلوبة بواسطة جهاز المفراس للاوزان المختلفة. أما معدل الجرعة المؤثرة للمرضى هو )1.8 mSv ( مقارنة مع UK. , Crawly et. al, Hugusted et.al


Article
Occupational Radiation Exposure to Workers Used 18F-DG

Authors: A.A. Wabdan --- H.M. Yassin --- M.S. El- Nagdy1
Journal: Al-Mustansiriyah Journal of Science مجلة علوم المستنصرية ISSN: 1814635X Year: 2018 Volume: 29 Issue: 4 Pages: 100-105
Publisher: Al-Mustansyriah University الجامعة المستنصرية

Loading...
Loading...
Abstract

The increasing interest of medical institutes in the development of imaging services to include the hybrid system [Positron Emission Tomography combined with Computed Tomography (PET/CT)], this system is acquiring explosive growth due to its ability to accurately detect and stage many types of cancer and follow the progress of treatments. An increasing demand for use of (18F-FDG PET) in oncology has been the main reason for its growth. The physical characteristics of positron emissions result in higher radiation risk for staff and growing use of PET/CT for diagnostic purposes increase radiation exposure.The objective of this study was to estimate the radiation exposure to the medical physicists, technicians and nurses working in three Egyptian nuclear medicine institutes under our investigations, based on the whole body collective dose measured by thermoluminescent dosimeters (TLDs) and the effective dose per study received by medical staff were measured by electronic pocked dosimeters and the finger doses by ring dosimeter during a period of six months. The (mean± SD) dose measured per PET/CT procedure were (2.45±0.137, 3.22±0.218 and 1.69±0.11) μSv for the medical physicist, technician and nurse respectively. The (mean± SD) dose measured per MBq of 18F-FDG were (7.35±0.43, 9.73±0.66 and 5.13±0.33) nSv/MBq for the medical physicist, technician and nurse respectively. The (mean± SD) finger dose measured per 18F-FDGPET/CT scans were (179.9±24.94, 8.82±2.912 and 24.15±4.164) μSv for the medical physicist, technician and nurse respectively

Keywords

PET/CT --- Radiation Dose --- 18F-FDG.


Article
Asses of Indoor Radon Dose and its Risks on children’s Health using Track Detectors: Case Study in Koya Kindergartens
تقييم جرع غاز الرادون و مخاطرها على صحة الاطفال باستخدام كواشف الاثر: دراسة الحالة في روضة مدينة كويسنجق

Authors: Hiwa H. Aziz --- Jahfer M. Smail --- Asaad. H. Ismail --- Hawbash H. Karim
Journal: journal of kerbala university مجلة جامعة كربلاء ISSN: 18130410 Year: 2015 Volume: 13 Issue: 2 Pages: 106-113
Publisher: Kerbala University جامعة كربلاء

Loading...
Loading...
Abstract

In order to assess effects of long term exposure of radon gas, CR-39NTDs exposed to indoor radon during summer season in the rest halls (ground floor) of 20 selected Kindergartens of the districts of Koya, Iraqi Kurdistan. Ventilation rate affect on the results of indoor radon concentration for each kindergarten. Good ventilation got a low level of indoor radon as measured inside Papula Kindergarten: opposite of that of poor ventilation rate got a high level of indoor radon, as measured inside Hang kindergarten.Average of high value of indoor radon concentration (Bq/.m3), annual effective dose (mSv/y) ,and potential alpha energy concentration (WL) were equal to (45.459±8.546) Bq/.m3,(0.281) mSv/y, and (0.056) mWL, respectively. Results were compared with some international reports and references that used CR- 39NTDs to asses of indoor radon concentration. It was under the levels that mentioned in other references.

لغرض تفييم تأثيرات التعرض لغاز الرادون لفترات طويلة , تم تعرض كواشف الاثر النووي الصلب من نوع (CR-39 ) الى غاز الرادون الداخلي داخل قاعات 20 روضة اطفال في قضاء كويسنجق في كوردستان العراق خلال موسم الصيف. بينت النتائج على ان معدل التهوية اثرت على نتائج تركيز عاز الرادون لكل روضة . وجد عند التهوية الجيدة انحفاض في تسجيل تركيز غاز الرادون كما في روضة ببولة , على عكس ذالك وجد عند التهوية الرديئة ارتفاع في تسجيل تركيز غاز الرادون كما في روضة هنك.وجد ان اعلى معدل لتركيز غاز الرادون الداخلي و الجرعة السنوية الفعالة و تركيز طاقة جهد الفا كان (45.459±8.546) Bq/m3 و ( 0.281 mSv/y ( و) 0.056) mWL على التوالي. تم مقارنة النتائج مع نتائج بعض التقارير و المصادر الدولية التي استحدمت كواشف الاثر النووية الصلب لتقيم تركيز غاز الرادون , ووجدت انها كانت تحت المستويات المنشورة في تلك المصادر .


Article
Measuring the concentrations of natural radioactive isotopes and radiation dose rates for Missan Province
قياس تراكيز النظائر المشعة الطبيعية ومعدلات الجرعة الاشعاعية لمحافظة ميسان

Loading...
Loading...
Abstract

This research included measuring the concentrations of natural radioactive isotopes U-238 and Th-232 and radiation dose rates for selected areas of Missan province, GR-460 system was used which has the potential to measure the concentrations of natural radioactive isotopes in (ppm) unit and measuring the radiation dose rates in µR/h unit. It was also used with the system the mobile device FH-40 which measures the radiation dose rates in units µSv/h the measurement results showed the absence of a significant increase in the U-238 and Th-232 concentration where the concentration of isotopes of U-238 and natural Th-232 (3.35-5.46) ppm respectively it is authorized and universally accepted. In terms of radiation dose rates it ranged between 45-65ոSv/հ by GR-460 system and FH-40 device and all these values are within the natural background radiation. Except for one outlying villages that affiliate to the Kahla area were found the radioactive source type 137Cs was left in a swamp of water rancid. Dose rate reached about 6 meters distance from the source 5.3 mSv/h by FH-40 device and GR-460 system 90.6 µR/h where equivalent 815 ոSvհ. The radioactive source has been transferred safely to the main store in AlTuwaitha site.

تضمن هذا البحث قياس تراكيز اليورانيوم- 238 والثوريوم-232 ومعدلات الجرعة الاشعاعية لمناطق منتخبة من محافظة ميسان، حيث استخدمت منظومة GR-460 المتنقلة التي لها الامكانية في قياس تراكيز النظائر المشعة الطبيعية بوحدة ppm و قياس معدلات الجرعة الاشعاعية بوحدة Rhµ. كما واستخدم مع المنظومة الجهاز المحمول FH-40 الذي يقيس معدلات الجرعة الاشعاعية بوحدات հ vSµ. اظهرت نتائج القياسات عدم وجود زيادة ملحوظة في تراكيز النظائر المشعة لليورانيوم -238 والثوريوم -232 في المناطق المنتخبة حيث بلغ تركيز نظيري اليورانيوم والثوريوم الطبيعي ppm(3.35- 5.46 ) على التوالي وهي قيم مصرح بها ومقبولة عالميا. اما من حيث معدلات الجرعة الاشعاعية فقد ترواحت بين ոSvհ) 45-65 ) قيست بواسطة منظومة GR-460 وجهازFH-40 وجميع هذه القيم هي ضمن الخلفية الاشعاعية الطبيعية. باستثناء احدى القرى النائية التابعة لقضاء الكحلاء حيث عثر على مصدر مشع نوع Cs137 كان متروكاً في بركة للمياه الاسنة حيث بلغ معدل الجرعة الاشعاعية على بعد 6 امتار mSvհ 5.3 بواسطة الجهاز المحمول FH-40 اما قراءة المنظومة فقد بلغت µR/h 90.6 اي ما يعادل ոSvհ815 و نُقل المصدر بصورة امنة الى المخزن الرئيسي في التويثة.


Article
Measuring the Rates of Radioactive Contamination and Radiation Doses for Rockwool plant
قياس معدلات التلوث الاشعاعي والجرعات الاشعاعية لمعمل الصوف الصخري

Author: Ahmed Abdul Hassan Hussein أحمد عبد الحسن حسين
Journal: JOURNAL OF MADENAT ALELEM COLLEGE مجلة كلية مدينة العلم الجامعة ISSN: 2073,2295 Year: 2014 Volume: 6 Issue: 2 Pages: 49-60
Publisher: City College of Science University كلية مدينة العلم الجامعة

Loading...
Loading...
Abstract

This research aims to assess the radioactivity for the rock wool plant in the province of Baghdad – Al Taji city through conducting radiological survey for the plant which of six part ( crushers , furnaces , machines spinning , materials store and waste site ) in addition assessment of radiation doses to the worker who are near smelting furnaces by using portable detectors to know the level of exposure and the contamination resulting from smelting basalt stone operations which the essential material for making the rock wool, its contain the natural radioactivity series such as U-238 and Th-232 . The results of radiological survey were conducted showed the presence of a significant increase in the rates of radioactive contamination and the dose rates in the area of smelting furnaces ranged between (11.2- 7.81) cps using the FH-40 compared with the rate of natural background 0.75 cps and the rates of radiation doses ranged between (0.65- 0.47) µSv/h using the device RadEye compared with natural background 0.04 µSv/h ,while the reading in another site within normal levels . it also collected soil samples from the smelting furnaces and from basalt stone accumulation site accordance to IAEA standard which were measured by using gamma spectrometry ( which consist of high –purity germanium detector with efficiency of 30% and resolution 2 keV for energy 1.33 MeV of 60Co ) . The results of laboratory tests for the soil elected showed absence of a significant increase in the values of the concentration for the radionuclide which back to the series of U-238 and Th-23 and showed a natural concentrations for isotope of Radium -226 especially in the samples that have been taken from the smelting furnaces ( B1,B2) ranged between (62.23 – 24.1 ) Bq / kg, respectively, that Ra-226 isotope (1600 year half life ) emitting Alpha and Gamma rays and decaying to the Radon gas.Where high concentrations of Radon gas is one of the main reasons causing lung cancer, so it is necessary to use protective equipment needed by workers in these factories.

يهدف هذا البحث الى تقييم النشاط الاشعاعي لمعمل الصوف الصخري الواقع في محافظة بغداد / التاجي من خلال اجراء مسح اشعاعي للمعمل والمتكون من ستةاجزاء (الكسارات , الافران , ماكنات الغزل , المخازن, موقع النفايات وموقع تجميع حجر البازلت ) بالاضافة الى تقييم الجرعات الاشعاعية للعاملين باستخدام اجهزة الكشف الاشعاعي المحمولة لغرض معرفة الزيادة الحاصلة في مستويات التعرض والتلوث الاشعاعي الناتجة من عمليات صهر حجر البازلت الذي يعتبر المادة الاساس في صناعة الصوف الصخري وذلك لاحتوائه على السلاسل الاشعاعية الطبيعية مثل سلسلة اليوراينويم-238 والثوريوم-232. وقد اضهرت نتائج المسوحات الاشعاعية التي اجريت وجود زيادة ملحوضة في معدلات التلوث الاشعاعي في منطقة افران الصهر تراوحت بين cps)11.2– 7.81) باستخدام جهاز FH-40مقارنةً مع معدل الخلفيىة الاشعاعية الطبيعيةcps 0.75 اما معدلات الجرع الاشعاعية تراوحت بين հµSv( 0.65-0.47 ) باستخدام جهاز RadEye مقارنةً مع الخلفية الطبيعية հµSv 0.04 اما بقية المواقع فكانت القراءات ضمن مستوياتها الطبيعية . كما واخذت نماذج تربة من افران الصهر ومن موقع تجميع حجر البازلت وفق المعايير والمواصفات المعتمدة عالميا لهذا النوع من قياسات النشاط الاشعاعي. وتم قياساها باستخدام منظومة الجرمانيوم عالي النقاوة ذو كفاءة 30% وقدرة فصلkeV 2 للطاقة MeV 1.33 لنظير الكوبلت 60Co , اظهرت نتائج الفحوصات المختبرية لنماذج التربة الماخوذة عدم وجود زيادة ملحوظة في قيم النشاط الاشعاعي النوعي للنويدات المشعة التي تعود الى سلسلتي اليورانيوم-238 والثوريوم-232 واظهرت تراكيز طبيعية لنظير الراديوم -226 خاصةً في النماذج التي تم اخذها من افران الصهر حيث تراوحت بين Bqkg ( 24.1-62.23 ) حيث يعتبر نظير الراديوم-226( ذو عمر نصف 1600 سنة ) من النظائر الباعثة لاشعة الفا وكاما ويتحلل الى غاز الرادون ,وحيث ان ارتفاع تراكيز غاز الرادون هو احد الاسباب الرئيسية المسببة لسرطان الرئة لذا فانه من الضروري استخدام المعدات الوقائية اللآزمة من قبل العاملين في هذه المصانع .


Article
المعزولة من )Enterococcus( دراسة تأثير الليزر على بكتريا منتجات الألبان

Author: أحمد كاظم خضيري
Journal: Albahir journal مجلة الباهر ISSN: 23125721 Year: 2016 Volume: 3 Issue: 5+6 Pages: 17-25
Publisher: Shiite Endowment ديوان الوقف الشيعي

Loading...
Loading...
Abstract

AbstractIn this study, Enterococcus bacteria was isolated from the Iraqi local dairy products then it havebeen compared with global products from )Saudi Arabia, Jordan, Syria, Iran(,An study of absorptionspectrum have been achieved to the planted bacteria in the middle nutritious before and after theirradiation by laser, as used several lasers with wavelengths )405, 532, 650(nm and the laser powerof irradiation variable )1-20( m Watt and different irradiation times )1-24(min at different doses ofradiation. The results showed that the bacteria isolated focused largest amount of Iraqi and SyrianMilk, it turns out that the bacteria isolated positive Gram appeared on the spherical shape under amicroscope by )68.8%( of the total isolates, found them almost )79.8%( of the genus )Enterococcus(,and have found that higher absorption of isolated bacteria in the extent of wavelengths UV nearvisible light within the wavelength )235(nm and the absorbance of the bacteria less when irradiationlaser، note from the results that the effect of the laser (405)nm his percentage kill of bacteria higherthan the laser )532(nm This has the largest of the laser effect )650(nm under the same conditions, thestudy showed required to get the proportion of killing )100%( of time is )21( min and at least increase thelaser power or radiation dose, and increase energy density by increasing the exposure time enoughto damage the inside living cell and kill bacteria. The study has shown that lasers can be used as atool, rather than the traditional pasteurization sterilization that lose Taste the milk and some of itsproperties.

Quarterly Refereed Journal for Natural and Engineering science 18 Vol. 3, No. 5 and 6, P. (17-25)Aالخلاصةمن منتجات الالبان المحلية العراقية )Enterococcus( تم في هذه الدراسة تشخيص وعزل بكتريا من جنسومقارنتها بألبان منتجة من مصانع عالمية )سعودية ،اردنية ، سورية وإيرانية( بعد زرع البكتيريا في الوسط المغذي.دُرس طيف الامتصاص لها قبل وبعد تشعيعها بالليزر ، كما استعملت عدة ليزرات ذات الأطوال الموجية1-24 ( بجرعات ( min 1-20 ( وأزمان تشعيع مختلفة ( mW 405,532,650 ( وبقدره أشعاع متغيره ( nmإشعاعية مختلفة. بينت النتائج أن البكتيريا المعزولة تركزت بكمية أكبر بالالبان العراقية والسورية، كما تبين أن البكتيرياالمعزولة موجبة الغرام ظهرت على شكل كروي تحت المجهر بنسبة )% 68.8 ( من مجموع العزلات الكلية ، وجد منهاوتبين أن أعلى امتصاص للبكتريا المعزولة في مدى الاطوال ،)Enterococcus( تقريبا )% 79.8 ( التابعة لجنس235 ( كما أن الامتصاصية للبكتيريا تقل ( nm الموجية فوق البنفسجية القريبة من الضوء المرئي ضمن الطول الموجي)532( nm 405 ( له نسبة قتل للبكتيريا أعلى من الليزر ( nm عند التشعيع بالليزر، نلاحظ من النتائج أن تاثير الليزر650 ( ضمن نفس الظروف، أظهرت الدراسة ان الزمن المطلوب للحصول على ( nm وهذا له تأثير أكبر من الليزر21 ( ويقل بزيادة قدرة الليزر أو الجرعة الاشعاعية ، وان زيادة كثافة الطاقة بزيادة زمن ( min نسبة قتل )% 100 ( هوالتعريض كافية لإلحاق الضرر داخل الخلية الحية وقتل البكتريا.اثبتت الدراسة انه يمكن استعمال الليزرات أداة تعقيمبدل البسترة التقليدية التي تفقد الحليب مذاقة وبعض خواصة.


Article
Risk Of Cancer And Radiation Dose Received By Patients From Common Diagnostic Radiological Examinations

Author: Ridha Jawad Al-Basri *
Journal: Al-Kindy College Medical Journal مجلة كلية الطب الكندي ISSN: 18109543 Year: 2017 Volume: 13 Issue: 1 Pages: 66-69
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

Background: Although radiological diagnostic studies (RDS) are an important and acceptable part of medical practice, it is not without hazards. It is associated with increased risk of cancer. Unfortunately the typical and safe dose of each radiological examination is not known. Most of our knowledge of cancer risk comes from studies of survivors of those exposed to whole body radiation from atomic bomb in Hiroshima & Nagasaki, jobs associated with radiation exposure, Chernobyl survivors & patients treated with radiation therapy for cancer and other diseases. Objectives To estimate radiation dose received by patients from diagnostic radiological examinations and lifetime attributable risk of cancer (LTARC).Type of the study: A prospective study. Methods A prospective study was conducted in Al-Kindi Teaching Hospital (KTH) during the period from 1st June to 31st august 2016. The study was performed on 910 adult patients. There were 595 males (65.38%) and 315 females (34.62%); mean age was 41.5 years (range 20-63).Different RDS were considered including chest-x ray (CXR), skull x-ray(SXR), x-ray of limbs and pelvis (LPXR) for orthopedic causes , computed tomography scan (CTS) and mammography (MG) .Results CXR was performed for 260 (28.57%) patients which delivers 0.12 mSv. SXR was done for 160 (17.58%) patients which delivers 0.3 mSv. LPXR was performed for 220 (24.175%) which delivers 0.3-0.6 mSv. MG exposes 150 (16.48%) to 3 mSv. While CTS ,which delivers 6.2-16 mSv according to anatomic area being scanned, was done for 120(13.19%) patients. Conclusion There is great abuse for using RDS from both patients and doctors, without realizing their danger and association with cancer development. It was proved that RDS expos patients to different kinds of tissues injury including cancer.


Article
Measurement and calculate the concentrations of radioactive isotopes (238U,232 Th and 40K) and the radiation doses in Thiqar governorate using GR-460 system
)والجرع الاشعاعية في محافظة K 232 و Th,238U( قياس وحساب ت ا ركيز النظائر المشعة GR- ذي قار بأستخدام منظومة 460

Journal: JOURNAL OF MADENAT ALELEM COLLEGE مجلة كلية مدينة العلم الجامعة ISSN: 2073,2295 Year: 2016 Volume: 8 Issue: 2 Pages: 76-85
Publisher: City College of Science University كلية مدينة العلم الجامعة

Loading...
Loading...
Abstract

AbstractThis study included measurement and calculates the concentrations of radioactiveisotopes (238U, 232 Th and 40K) and the radiation doses in Thiqar governorate (Nasiriyah,Shatrah, Suq Chabaish, Rifai) has been conducting this research by radiological surveysystem (GR-460) that it has high efficiency in detection. This system consist from twolarge sodium iodide detectors Nal (TI) the size of each of them (256 inch3) associatedwith data analysis unit that associated with computer to display and store the results,this computer have analysis program (GR-660), which has the ability to determine thedose rate and the concentrations of radioactive isotopes (uranium - thorium - potassium)in soil. The concentrations of radioactive isotopes subject of research and doses radiationwere within the permitted nature limits. The radiation dose to sites that surveyed:)Nasiriyah Center 6.79 μR/h, Shatrah 7.2 μR/h, Suq Chabaish 6.41μR/h, Rifai 6.6μR/h andthe average dose rate for the whole Thiqar governorate was 6.8 μR/h(, theconcentrations of radioactive isotopes (238U, 232 Th, and40 k) to across the governorate asfollows: (uranium-238 2.7 ppm, thorium -232 5.6 ppm and for potassium- 40 14000).Key words: - radioactive isotopes, natural radiation,radiation dose

الخلاصة:40 )والجرع الاشعاعية لمحافظة ذي قار K 232 و Th,238U( تضمنت هذه الد ا رسة قياس و حساب ت ا ركيز النظائر المشعة)قضاء الناصرية, قضاء الشطرة, قضاء سوق الشيوخ والجبايم, قضاء الرفاعي(,تم اج ا رء البحث بمنظومة الكشفذات كفاءة الكشف العالية والمنظومة عبارة عن كاشفين كبيرين نوع أيوديد الصوديوم المطعم )GR- الاشعاعي ) 460256 ( مرتبطة بوحدة تحليل البيانات والاخيرة ترتبط بحاسبة حقلية لعرض inch حجم كل منهما) 3 Nal(TI( بالثاليومالذي لة القدرة على تحديد معدل الجرعة و نسبة ت ا ركي ا زلنظائر )GR- وخزن النتائج والحاسبة محملة ببرنامج) 660المشعة في التربة ) اليو ا رنيوم – الثوريوم – البوتاسيوم(. كانت ت ا ركيز النظائر المشعه موضوع البحث والجرع الاشعاعيةضمن الحدود الطبيعة المسموحة وكانمعدل الجرعة الاشعاعية للمواقع التي أجري لها المسح الاشعاعي كالاتي)مركز6.41 ،قضاء الرفاعي 6.6 μR/h 7.2 ،قضاء سوق الشيوخ والجبايم μR/h 6.79 ،قضاء الشطرة μR/h الناصرية6.8 ( اما ت ا ركيز النظائر μR /h ومتوسط معدل الجرعة لعموم محافظة ذي قار هو μR / h2.7-238 ، وللثوريوم - 232 كانت ppm 40 ( فكانت لعموم المحافظة كالاتي )لليو ا رنيوم k 232 و Th,238U( المشعة.(14000ppm 5.6 وللبوتاسيوم المشع ppmكلمات مفتاحية:- النظائر المشعة,الإشعاع الطبيعي, الجرعة الاشعاعية.

Listing 1 - 8 of 8
Sort by
Narrow your search

Resource type

article (8)


Language

English (5)

Arabic (2)

Arabic and English (1)


Year
From To Submit

2018 (1)

2017 (1)

2016 (2)

2015 (2)

2014 (1)

More...