THERMAL ANALYSIS OF TRANSIENT OPERATION OF A SMALL SCALE REFRIGERATION SYSTEM

Loading...
Loading...
Abstract

An unsteady- state model of vapor compression refrigeration system is presented. Thermal and flow processes occurring in a small-scale refrigeration system have been discussed. A theoretical description of the processes in the system components has been proposed in order to develop a theoretical model of the entire system. Components model include the heat exchangers (condenser and evaporator), expansion valve and compressor. For the condenser and evaporator mathematical model, assume two approaches for homogenous refrigerant, the first approach is the lumped model and the second is distributed model.Experimental investigations are carried out on the laboratory scale system model RCT/EV.The results obtained from the two models prediction are in a good agreement with the experimental results. The system approaches its final steady-state operating condition in a few minutes.

يتناول البحث دراسة التغيرات الفيزياوية التي تحدث لمائع الشغل في كل مكونة من مكونات وحدة تثليج تعمل بدورة تبريد انضغاطية واعتمدت الحالة الغير المستقرة (unsteady) في هذه الدراسة. حيث تمت مناقشة عمليات الجريان وانتقال الحرارة مع وصف نظري للعمليات التي تحدث داخل مكونات المنظومة من اجل تطوير نموذج رياضي للمنظومة وتشمل الدراسة الأجزاء التالية: المبادل الحراري (المكثف والمبخر) وصمام الخنق والضاغط . إن النموذج الرياضي الذي تم عمله إلى المكثف و المبخر اعتمد على المعادلات الفيزياوية لتوازن الكتلة والطاقة في حاله الجريان غير المستقر بالاعتماد على تغير الزمن. أما في للضاغط وصمام الخنق فان العمليات اعتبرت مستقرة وذلك لأنها تحدث بسرعة اكبر من المبادل الحراري . تمت الدراسة النظرية على أساس الجريان المتجانس في المكثف والمبخر وعلى اعتماد الحالة غير المستقرة . وتم عمل نموذجين منفصلين باستخدام فرضيتين: الفرضية الأولى: هي طريقة السعات المجمعة (Lumped)وتم في هذه الطريقة توقع معدل التغيرات لدرجات الحرارة كتوزيع حقيقي للمسافات والزمن. و الفرضية الثانية هي طريقة التوزيع(Distributed) لتوقع التغير ألموقعي لدرجة الحرارة والمحتوي الحرارى في كل نقطة كدالة للزمن . هذين النموذجين أعطيا وصفا نظريا جيدا للظواهر الفيزيائية التي تحدث للمائع في كل مكونة من مكونات وحدة تثليج.النتائج ألعمليه تم إنجازها بشكل حقيقي على وحدة تثليج نموذجيه مختبريه إيطالية الصنع. تم إعداد برنامج حاسوبي لكل طريقة لحساب الاستجابة العابرة لوحدة تثليج انضغاطية مبردة بالهواء تعمل بمائع التثليج R134a .النتائج العملية تمت مقارنتها مع النتائج النظرية للطريقتين وأعطت نتيجة جيدة ومتقاربة.


Article
A Study For Refrigerant's Characteristics to Choose the Optimum For Ejector Refrigeration System
دراسة صفات موائع التثليج واختيار الأمثل لنظام تثليج يعمل بالقاذف

Authors: Mohammad S. Al - Dabbagh محمد سالم الدباغ --- Dr. Adnan M. Al – Saffawi د. عدنان محمد الصفاوي
Journal: AL Rafdain Engineering Journal مجلة هندسة الرافدين ISSN: 18130526 Year: 2011 Volume: 19 Issue: 6 Pages: 16-29
Publisher: Mosul University جامعة الموصل

Loading...
Loading...
Abstract

AbstractRefrigeration systems needs efficient refrigerant to perform it's determined objective, so, an optimum refrigerant, must have a good and desirable characteristics as compared with other refrigerants as well as a high coefficient of performance for the working cycle, which results for minimizing operating power to attain determined refrigeration capacity.A variety kinds of improved refrigerants had been appeared within the last twenty years, and many countries did large efforts to phaseout some refrigerants, or at least reduce it's usage, that's for it's ozone layer depletion and it's bad influence on environment and climate.This research deals with a comparative study between many Refrigerants on the basis of it's characteristics , COP and compressibility factor in ejector refrigeration system to select the optimum to be used in this system.From this study results , the optimum refrigerant is Butane (R – 600), which have a good characteristics , a relatively high compressibility factor values , and a COP value of (0.615) , which is a good result as compared with other refrigerants included the phaseouted for it's bad influence on environment and climate.

الخلاصةان أنظمة التثليج تحتاج الى مائع كفوء يؤدي عمله المحدد ، إلا أن الحصول على مائع تثليج أمثل مناط بوجود صفات جيدة ومرغوبة فيه تميزه عن غيره من الموائع ، وتسهم في ارتفاع معامل الأداء للدورة التي يقوم بتشغيلها ، وبالنتيجة تقليل القدرة اللازمة للتشغيل وتحقيق سعة التثليج المطلوبة .وقد ظهرت أنواع مختلفة من موائع التثليج خلال العقدين الماضيين ، وهناك جهود كبيرة تبذل في العديد من الدول لاستبعاد بعض من هذه الموائع أو الحد من استخدامها، لتأثيرها على طبقة الاوزون وعلى البيئة والمناخ .تناول البحث إجراء دراسة مقارنة بين مجموعة من موائع التثليج بالاستناد الى خصائصها ومعامل ادائها ومعامل انضغاطها في نظام تثليج يعمل بالقاذف للتوصل الى الامثل للاستخدام في هذا النظام . ومن نتائج هذه الدراسة يتبين ان مائع التثليج الامثل هو البيوتان (R – 600) لما يمتلكه من خصائص ومميزات إيجابية ، وان قيم معامل الانضغاط له عالية نسبياً ، وقد بلغ معامل أداءه 0.615 وهي قيمة جيدة نسبة الى الموائع الاخرى لاسيما التي تم التخلي عنها لأضرارها على البيئة والمناخ .


Article
Performance of Alternative Refrigerant R431A on Air- Conditioning System under Real Transient Conditions
أداء المبرّدِ البديلِ آر 431 أي على منظومة تكييف الهواء تحت ظروف استجابة عابرة حقيقية

Author: Haider ali hussen
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2013 Volume: 31 Issue: 10 Part (A) Engineering Pages: 1962-1971
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

This paper presents the performances of new ozone-friendly refrigerant (R431a) in air-conditioning system were investigated experimentally and compared with R22 under transient conditions.R431a has no ozone depletion potential and very low greenhouse warming potential of less than 43 (ASHRAE Listed,2007)[1].The variation in refrigeration rate of evaporator, work consumption of compressor and heat rejection rate of condenser with time from the start to stop of the air condition system have been examined. Test results showed that the refrigeration rate of evaporator and heat rejection rate of condenser drops almost parallel to each other, both with a decreasing rate with time. The power consumption on the other hand does not increasing much. The coefficient of performance of R431a decreased from rang 8.96 to 9.28% through (5000 sec) at different ambient temperatures. The refrigeration rate of evaporator decreased by 2.69% through 5000 sec at ambient temperature 30 C° for R431a .The heat rejection rate of condenser decreased by 2.34% through 5000 sec at ambient temperature 30 C° for R431a. Results showed that the coefficient of performance of R431a is 14.67 to 20.34% higher than that of R22. Compressor input power of R431a is 8.39 to 14.19% lower than that of R22 at different ambient temperatures.

هذا البحث يقدم دراسة عملية لاداء منظومة تكييف الهواء باستخدام موائع تبريد جديدة R431a تحت ظروف استجابة عابرة حقيقية بالمقارنة مع الموائع القديمة R22.وسيط تبريد R431a لايؤثر على طبقة الاوزون وكذالك GWP اقل من 34.أظهرت النتائج العملية بان كمية الحرارة الممتصة من قبل المبخر وكمية الحرارة المطروحة من قبل المكثف تنخفض بشكل متوازي. لكن الطاقة المستهلكه من قبل الظاغط من جهة اخرى لا تزداد كثيرأ. معامل الأداء للغاز (R431a) تقل بنسبة 8.96-9.28% خلال 5000 ثانية عند درجاتِ الحرارة البيئيةِ المختلفةِ . كمية الحرارة الممتصة من قبل المبخر تقل بنسبة 2.69% خلال 5000 ثانية عند درجة الحرارة البيئيةِ 30 مئوية للغاز (R431a). كمية الحرارة المطروحة من قبل المكثف تقل بنسبة 2.34% خلال 5000 ثانية عند درجة الحرارة البيئيةِ 30 مئوية للغاز (R431a). معامل الأداء للغاز (R431a) هو أعلى بنسبة 14.67-20.34% بالمقارنه مع غاز(R22). وكذالك أقل أستهلاك للطاقه للغاز (R431a) بنسبة 8.39-14.19% بالمقارنه مع غاز(R22) عند درجاتِ الحرارة البيئيةِ المختلفةِ.


Article
Studying the Performance of Refrigeration Units Powered by Solar Panel

Authors: Venus Majeed Hameed فينوس مجيد حميد --- Maha Ali Hussein مها علي
Journal: Iraqi Journal of Chemical and Petroleum Engineering المجلة العراقية للهندسة الكيمياوية وهندسة النفط ISSN: 19974884/E26180707 Year: 2013 Volume: 14 Issue: 1 Pages: 39-46
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

An experimental study was conducted to determine the performance of a solar electric refrigeration system. The system contained flat photovoltaic solar panel which absorbs the solar energy and convert it to electrical energy, used to run the refrigeration cycle. Two refrigeration cycles with electrical solar panel were used over a period of 12 months, the first one with classical parts known in refrigeration cycle, while the second one introduced heat exchanger which improves the coefficient of performance by saving the consumed energy. The coefficient of performance of these refrigeration cycles with compressor efficiency 85% are 2.102 and 2.57 respectively. The overall efficiency of the two systems are 18.9% and 23.13%.


Article
Study The Use Of Solar Energy For Heating Buildings In Baghdad City
دراسة استخدام الطاقة الشمسية لأغراض تدفئة الابنية في مدينة بغداد

Author: Ahmad Hassan Khuder أحمد حسن خضر
Journal: Journal of Engineering and Sustainable Development مجلة الهندسة والتنمية المستدامة ISSN: 25200917 Year: 2013 Volume: 17 Issue: 6 Pages: 215-230
Publisher: Al-Mustansyriah University الجامعة المستنصرية

Loading...
Loading...
Abstract

The research is devoted of study the possibility of using solar energy for home heating system by using the absorption refrigeration system and solar collector design has the ability to provide the heating system, solar thermal energy intake in winter, and chosen for the study of building and an area of 100 m^2 and study the system for the winter months, December (12) and January (1) and February (2). Was represented mathematically as the system is calculated solar energy falling on the rooftop solar energy absorbed and the energy collected and added energy by auxiliary heater in addition to water temperatures to different locations of the system and the thermal loss, efficiency of solar collector and heating load for all hours of operation of the system, and can raise the efficiency of the system in winter by using the system to heat water for residential uses in addition to heating the air.

تضمن البحث دراسة أمكانية استخدام الطاقة الشمسية لأغراض تدفئة المنازل باستخدام منظومة تثليج امتصاصية وتصميم مجمع شمسي له القدرة على تزويد منظومة التسخين الحرارية الشمسية بالطاقة الحرارية شتاء"ا ولأغراض الدراسة اختيرت بناية نموذجية مساحتها 100 m2 ودراسة المنظومة للأشهر الشتوية كانون الأول (12) وكانون الثاني (1) وشباط (2). تم تمثيل المنظومة رياضيا حيث تم حساب الطاقة الشمسية الساقطة على سطح المجمع الشمسي والطاقة الممتصة والمجمعة والطاقة المضافة من السخان المساعد بالإضافة إلى درجات حرارة الماء لمواقع مختلفة من المنظومة والخسائر الحرارية وكفاءة المجمع الشمسي وحمل التدفئة لكل ساعة من ساعات اشتغال المنظومة، ويمكن رفع كفاءة المنظومة شتاءا باستخدام المنظومة لتسخين الماء للاستعمالات المنزلية بالإضافة الى تدفئة الهواء.


Article
PERFORMANCE INVESTIGATION OF VAPOR COMPRESSION REFRIGERATION SYSTEM WITH INTEGRATED MECHANICAL SUB-COOLING CIRCUIT USING HYDROCARBON BLENDS
استقصاء اداء منظومة التبريد الانضغاطيه مع دورة تبريد مفرط باستخدام خلائط تبريد هايدروكاربونية

Author: Ahmed J. Hamad أحمد جاسم حمد
Journal: DIYALA JOURNAL OF ENGINEERING SCIENCES مجلة ديالى للعلوم الهندسية ISSN: 19998716/26166909 Year: 2016 Volume: 9 Issue: 1 Pages: 1-17
Publisher: Diyala University جامعة ديالى

Loading...
Loading...
Abstract

This work presents an experimental study to investigate the performance of vapor compression refrigeration system using hydrocarbon mixtures. A sub-cooling circuit and phase separator are integrated with main vapor compression refrigeration system and used to predict the performance of hydrocarbon blend R-290/R-600a as alternative refrigerant with three mass fractions of (60/40, 50/50 and 40/60) and compared with R-134a. The results showed that, the enhancement in the system performance was about 14% increase in coefficient of performance, 6% increase in refrigeration effect and reduction percentage in freezing compartment temperature was in range of 12%. Lower values of pressure ratio and discharge temperature are noticed for R-290/R-600a blends comparing with R-134a. The reduction percentage in compressors power was in range of 9% during operation period. It can be concluded that the hydrocarbon refrigerants are an efficient, economically feasible and environment friendly alternative refrigerants to R-134a in vapor compression refrigeration system with sub-cooling circuit. Hydrocarbon refrigerants are flammable, therefore, safety implications of using such fluids may require specific system design and suitable operating and maintenance routines to prevent ignition and leakage sources from refrigeration system components.

يقدم هذا البحث دراسة تجريبية لاستقصاء اداء منظومة التبريد الانضغاطيه باستخدام خليط من وسائط التبريد الهيدروكاربونيه.تم اضافة دورة تبريد مفرط وفاصل طور الى منظومة التبريد الانضغاطيه واستخدمت لفحص اداء خليط هايدروكاربوني من R-290/R-600a وبنسب خلط كتليه 60/40 ,50/50 و 40/60 باعتباره وسيط تبريد بديل وقورنت النتائج المستحصله مع وسيط التبريد R-134a. تحليل النتائج قد اظهر وجود تحسين في معامل الاداء بحدود 14% وفي سعة التبريد %6 ونسبة التخفيض في درجة حرارة مقصورة التثليج كانت بحدود 12% مع انخفاض في قيم نسبة الانضغاط ودرجة الحرارة بعد الضاغط للخليط الهايدروكاربوني R-290/R-600a مقارنة مع وسيط التبريد R-134a ونسبة التخفيض في قدرة الضاغط كانت بحدود 9%. يمكن الاستنتاج بان خلائط التبريد الهايدروكاربونيه تعتبر وسائط تبريد كفوءة بديله لوسيط التبريد R-134aفي منظومة التبريد الانضغاطيه مع دورة تبريد مفرط. وسائط التبريد الهايدروكاربونية قابلة للاشتعال لذلك فان استخدامها يتطلب تطبيق اجراءات امان محددة عند تصميم مكونات منظومة التبريد او عند اجراء الصيانة لمنع تسرب أو اشتعال وسيط التبريد.


Article
Optimization of Ethylene Refrigeration System Using Genetic Algorithms Method
إختيار الظروف المثلى لأنظمة تبريد الأثيلين باستخدام الطريقة الخوارزمية الجينية

Authors: Shurooq Talib Al-Hemeri --- Mumtaz A. Yousif --- Ahmed M. AL Barifcani
Journal: Journal of Petroleum Research & Studies مجلة البحوث والدراسات النفطية ISSN: 22205381 Year: 2016 Volume: 272 Issue: 13 Pages: 1-37
Publisher: Ministry of Oil وزارة النفط

Loading...
Loading...
Abstract

Ethylene refrigeration for gases separation at low temperature and high pressure for olefin production is an important technique in the chemical industry. Since small changes in the operating conditions of such a process can have a significant influence on its economics, optimization is desirable. The present work was aimed to propose and establish a mathematical model for the ethylene refrigeration system of the ethylene plant in Basrah petrochemical complex NO.1 (PC1) and reformulated as a geometric programming problem using Visual Basic for predicting:- (overall efficiency of the ethylene refrigeration system {% }and percent of energy saving %E). Through the formulated model shaft work consumption by the centrifugal compressor, refrigeration effect and coefficient of performance of the system were obtained and other parameters concerning the system. The results of simulation showed a good agreement with the manufacturer manual.In this study the effect of four factors as independent variables on the overall refrigeration system efficiency and percent of energy saving were studied ;evaporator low pressure (PL) in the range of (1-3)bar ,compressor discharge high pressure (Ph) in the range of ( 28-32)bar ,condenser degree of sub-cool temperature (Tsub-D) in the range of (6-22)0C and evaporator degree of superheat temperature (Tsup-D) in the range of (1-5)0C. And the optimum conditions that aimed to minimize the thermodynamic irreversibility i.e (maximize overall refrigeration system efficiency) and also lower operating cost i.e (maximize percent of energy saving) evaporator low pressure (PL) (2.8 bar), compressor discharge high pressure (Ph) (28.7 bar), condenser degree of sub-cool temperature (Tsub-D) (190C), and evaporator degree of superheat temperature (Tsup-D) (3.40C). At these conditions the overall refrigeration system efficiency is (81.8%) and percent of energy saving is 51.18% with respect to conditions in the factory.Ke

إن أنظمة التبريد بإستخدام غاز الاثيلين كمادة تبريد من العمليات المهمة لأغراض فصل الغازات في الصناعات الكيمياوية عند الضغط العالي و درجة الحرارة الواطئة. و لهذا فإن أي تطور بالظروف التشغيلية للنظام ولو كان قليلاً فإنه يؤثر بشكل ملحوظ على اقتصاديات العملية أي إنه يوفر الكثير من المال . الدراسة الحالية تهدف لإقترح موديل رياضي لنظام تبريد الأثيلين الموجود في وحدة الأثيلين في المجمع البتروكيمياوي رقم (1) و قد تم بناء برنامج بالحاسبة الإلكترونية بلغة Visual Basic)) يستخدم لتحديد الكفاءة الكلية للدورة و النسبة المئوية لخزن الطاقة و بمختلف الظروف التشغيلية و تم من خلاله حساب الشغل المستهلك بواسطة الضاغطة المركزية و سعة التبريد و معامل اداء النظام بالإضافة إلى العديد من العوامل المتعلقة بالنظام . إن نتائج التحليل الرياضي أظهرت تقارب جيد بين القيم الناتجة من عمل البرنامج و بين القيم الحقيقية لنظام التبريد حيث تم دراسة أربعة متغيرات رئيسية في الدورة هي ضغط المبخرات المنخفض ، الضغط العالي الناتج من الكابسة ، درجة الحرارة الناتجة من المكثفات و درجة الحرارة الناتجة من المبخرات و ضمن المدى bar (1-3) ، (28-32) bar ، (6-22)oC و (1-5)oC على التوالي . وكانت النتائج التي تم الحصول عليها هي : (2.8 bar) لضغط المبــــخرات المنخفض ، (28.7 bar) للضغط العالي الناتج من الكابسة ، (19oC) لدرجة الحرارة الناتجة من المكثفات و (3.4 oC) لدرجة الحرارة الناتجة من المبـخرات . و نتائج الدراسة أظهرت إن زيادة ضغط المبخرات المنخفض يؤدي إلى تحسن الكفاءة في النظام و كذلك زيادة حزن الطاقة لكن الزيادة بالضغط العالي الناتج من الكابسة يؤدي إلى خفض كفاءة النظام و التقليل من خزن الطاقة .