research centers


Search results: Found 8

Listing 1 - 8 of 8
Sort by

Article
Design and Simulation of DPSS Laser with SHG for Material Processing

Author: A.A. Alsharify
Journal: Iraqi Journal of Applied Physics Letters الرسائل العراقية في الفيزياء التطبيقية ISSN: 1999656X Year: 2009 Volume: 2 Issue: 1 Pages: 3-8
Publisher: iraqi society for alternative and renewable energy sources and techniques الجمعية العراقية لمصادر وتقنيات الطاقة البديلة والمستجدة

Loading...
Loading...
Abstract

In the present work, multilayer reflection coating analysis has been employed for design and simulating diode-pumped solid state (DPSS) laser system with second harmonic generation (SHG) using composite crystal (DPM010X). It was found that the optical reflection greatly depends on the refractive index, optical thickness and number of anti-reflection coating layers used. The calculated refractive index was found to be 1.949 for phase matched angle of 23.2° for the KTP non-linear crystal.

Keywords

DPSSL --- SHG --- KTP --- Nonlinear crystal --- Optical pumping


Article
Effect of Laser Wavelengths on the Silver Nanoparticles Size Prepared by PLAL

Authors: Mohammed J. Haider --- Mohammed S. Mahdi
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2016 Volume: 34 Issue: 7 Part (A) Engineering Pages: 1324-1334
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

In this present study, Pulsed Laser Ablation in Liquid (PLAL) experiment setup for synthesis colloidal solution of silver-NPs. The laser system was used in this study, a (Nd-YAG) nanosecond laser system with optimal pulse duration of 10 ns and repetition rate 1-6 Hz. The Laser wavelengths were: 1064 nm, 532 nm and 355 nm. The spot size of the laser beam on the surface of metal plate was varied in the range of 1.4-1.5 mm in diameter by changing the distance between the focusing lens and the metal plate.The ablation process was typically done for 1 minute. The average particle size has been characterized by TEM, SEM and UV-Vis investigation. From morphologyresults for colloidal silver nanoparticles images were spherical shape and average size of the particles is 55-60 nm at wavelength (λ =1064 nm), average size of the particles is 35-40 nm at(λ =532 nm) and average size of the particles is 28 nm at(λ =355 nm).

Keywords

silver nanoparticles --- PLAL --- Nd:YAG laser --- SHG --- THG


Article
Thin Films Ablation by Induced Forward Transfer Technique
إزالة الاغشية الرقيقة باستخدام تقنية انتقال الليزر المحتث المباشر

Authors: Adawiya J. Haider --- Iman H. Hadi
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2012 Volume: 30 Issue: 8 Pages: 1405-1414
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

Laser-Induced Forward Transfer (LIFT) is a technique which enables thecontrolled transfer of a thin film material from a transparent carrier (donor) to areceiver substrate (acceptor). The receiver substrate is usually placed in paralleland close to the thin film source under air or vacuum conditions. In this workmicrodeposition of gold (Au) and Copper (Cu) thin films were deposited on glasssubstrate by Pulsed Laser Deposition (PLD). These thin films were irradiated by asingle pulse and transferred to a silver (Ag) and silicon (Si) receiver substrates. Thelaser source used for this study was a Nd-YAG Q-Switching second harmonicgeneration (SHG) Pulsed Laser with a wavelength 532nm, repetition rate 1-6 Hz,and pulse duration 10ns. Deposited size, morphology and adhesion to the receiversubstrate as a function of applied laser fluence are investigated.

الانتقال الامامي المحتث بالليزر هو تقنية تسيطر على انتقال جزء من الغشاء الرقيق للمادةمن الحاملات الشفافة (الواهبة) الى القواعد المستلمة (القابلة) ،وعادة ما توضع القواعد المستلمةبموازاة وبالقرب من الغشاء الواهب وتتم العملية في الجو او تحت ظروف الفراغ. في هذا البحثتم ترسيب اغشية رقيقة من معدني الذهب والنحاس على قواعد من الزجاج (الواهبة) بواسطةالترسيب بالليزر النبضي . تم تسليط نبضات منفردة على هذه الاغشية وتم نقلها الى قواعد منالفضة والسليكون. مصدر الليزر المستخدم في هذه الدراسة هو ليزر النيديميوم- ياك يعمل بنمط6 هرتز وآمد نبضة 10 - التولد التوافقي الثاني( بطول موجي 532 نانومتر و تكرارية 1نانوثانية).حجم الغشاء المرسب على القاعدة المستلمة ، طوبوغرافية السطح ،وقوة الالتصاق بينالغشاء والقاعدة المستلمة تم دراستها كدالة لكثافة طاقة الليزر المستخدم.


Article
Impact of Laser Induced Forward Transfering on Transfer of Escherichia Coli Bacteria
الانتقال الامامي المحتث بالليزر لنقل بكتريا E.coli

Authors: Adawiya J. Haider --- Amer T. Tawfeeq --- Amar H. Jareeze
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2014 Volume: 32 Issue: 5 Part (B) Scientific Pages: 885-891
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

Laser Induced Forward Transfer (LIFT) is a technique uses to print different materials with high spatial resolution for microarray preparation. In this work, the mechanism in which LIFT process effect E.coli bacteria used to produce microarray droplets from a liquid solution thin film coated a glass slide previously coated with gold of 65nm thick which was used as a laser absorbing layer. The transferred bacteria was achieved at laser fluence of 10 J/cm2 and 100 µm distance between donor and receptor substrates.The purpose of using such a technique was to assess the impact of laser on the viability of the transferred bacteria. Scanning electron microscope observation indicated that E.coli bacterial cells integrity was maintained during the process. The bacteria was viable as tested using MacConkey agar culture media.

النقل الامامي المحتث بالليزر تقنية تستعمل لنقل مختلف المواد وبدقة مكانية عالية لتحضير مجموعات بحجم مايكرومتر في هذا البحث , الية تاثير البكتريا E.coli المستعملة لانتاج قطيرات مايكروية من محلول سائل على شكل غشاء يغطي شريحة زجاجية قد طليت مسبقا بالذهب بسمك 65 نانومتر والتي تستعمل كطبقة ماصة لاشعة الليزر , طاقة اشعة الليزر المستعملة لنقل البكتريا كانت 10جول/سم2 و 100مايكرومتر المسافة بين المانح والطبقة القابلة . الغرض من استعمال هذه التقنية هو تقييم تاثير الليزر على قابلية النمو البكتريا المنقولة , اشار المجهر الالكتروني الماسح ان البكتريا المنتقلة سليمة والتي تم فحص النمو بواسطة الوسط المغذي .


Article
Transfer of Metal Thin Films by Laser Induced Forward Technique

Author: Iman H. Hadi
Journal: Al-Nahrain Journal of Science مجلة النهرين للعلوم ISSN: (print)26635453,(online)26635461 Year: 2016 Volume: 19 Issue: 3 Pages: 87-91
Publisher: Al-Nahrain University جامعة النهرين

Loading...
Loading...
Abstract

In this work preparation and characterization of Aluminum thin films by laser induced forward transfer has been studied. These thin films were deposited by thermal evaporation on glass substrates as donor substrates. These thin films were irradiated by a single pulse and transferred to a silver (Ag) and silicon (Si) receiver substrates. The laser source used for LIFT process was a Nd-YAG Q-Switching second harmonic generation (SHG) Pulsed Laser with a wavelength 532nm, repetition rate 1-6 Hz ,and pulse duration 10ns. Deposited size, morphology and adhesion to the receiver substrate as a function of the applied laser fluence are investigated.

في هذا العمل تم تحضير ودراسة خصائص الألمنيومِ بطريقة الانتقال المحتث المباشر بالليزر. تم تحضير اغشية الالمنيوم بطريقة التبخير الحراري كأغشية واهبة. تم تسليط نبضات منفردة على هذه الاغشية وتم نقلها الى قواعد من الفضة والسليكون. مصدر الليزر المستخدم في هذه الدراسة هو ليزر النيديميوم- ياك يعمل بنمط التولد التوافقي الثاني (بطول موجي 532 نانومتر و تكرارية 1-6 هرتز وآمد نبضة 10 نانوثانية). حجم الغشاء المرسب على القاعدة المستلمة, طوبوغرافية السطح, وقوة الالتصاق بين الغشاء والقاعدة المستلمة تم دراستها كدالة لكثافة طاقة الليزر المستخدم.


Article
Effect of laser energy density on ZnO / α- Al2O3 of films grown by pulsed laser deposition

Authors: Khaled M. Chahrour --- Amer B. Dheyab --- Mohammad J .Haider --- Ali K. Shakir --- et al.
Journal: Iraqi Laser Scientists Journal مجلة علماء الليزر العراقية ISSN: 2523 689X Year: 2018 Volume: 1 Issue: 2 Pages: 12-21
Publisher: Iraqi Laser Scientists Society جمعية علماء الليزر العراقيين

Loading...
Loading...
Abstract

In this work, Pulsed Laser Deposition (PLD) was employed for preparation of the thin films of Zinc Oxide on Sapphire α- Al2O3 (0001). The effect of laser energy density on the structure and optical characterizations of the ZnO films have been studied by X-Ray diffraction (XRD), and Scanning Electron Microscopy (SEM). The results showed that crystalline and (002)-oriented ZnO films were obtained at laser fluence 0.8, 1.6, and 2.4J/cm2 and the optimized growth ZnO films were at substrate temperature of 400 oC.Optical transmission for all films was around 85-90% within the visible region of the spectrum.


Article
Effect of Substrate Temperature on the Structural and Morphological Properties of Nano-structure ZnO films by Pulsed Laser Deposition

Authors: Adawiya J. Haider --- Afnan k. yousif
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2011 Volume: 29 Issue: 1 Pages: 58-64
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

In this work, ZnO thin films were grown on sapphire (0001) substrate byPulsed Laser Deposition using SHG with Q-switched Nd:YAG pulsed laser operationat 532nm in O2 gas ambient 5×10-2 mbar at different substrate temperatures varyingfrom room temperature to 500°C. The influence of the substrate temperature on thestructural and morphological properties of the films were investigated using XRD andSEM. As result, at substrate 400°C, a good quality and crystalline films were depositedthat exhibits an average grain size (XRD) of 22.42nm with an average grain size(SEM) of 21.31nm.


Article
Effect of Diabetes in Blood Dilution and Angle of Rotation on the Output Power of Second Harmonic Generation of Nd: YAG Laser

Author: Mohammed F. Mohammed
Journal: Al-Nahrain Journal of Science مجلة النهرين للعلوم ISSN: (print)26635453,(online)26635461 Year: 2012 Volume: 15 Issue: 4 Pages: 114-119
Publisher: Al-Nahrain University جامعة النهرين

Loading...
Loading...
Abstract

Glucose monitoring is a crucial factor for diabetic self management. Widely used technologies require the use of fresh blood samples in special test strips. This is expensive and does not lend it self to continuous monitoring. An alternative method of measuring blood glucose levels optically is investigated. This method is called “Optical Activity”. It’s able to determine glucose concentrations with varying degrees of sensitivity and ranges of applicability. This method is used to determine the angle of rotation for different glucose concentrations when the laser beam passing through the samples of blood.In this research, a green laser of second harmonic generation (SHG) of Nd: YAG with measured maximum output power 55 mW and wavelength of 532 nm was used. The output power of laser beam which was passing through the glass cuvette of blood with diabetes was measured as a function of calculated specific rotation angle for different concentrations of the diluted blood and also the output power of laser beam which was passing through the glass cuvette of blood with null diabetes was measured. These results of two samples are reported and the implications for possible new monitoring strategy are considered. Thus, the person can be specified his blood contain the diabetes or not.

مراقبة الكلوكوزِ عامل حاسم للإدارةِ الشخصية لداء السكر. تَتطلّبُ التقانات الحالية الشائعة الإستعمالُ أستخدامُ عيناتِ دمّ جديدِة في أشرطةِ الإختبار الخاصّةِ وهي غاليةُ وغير ملائمة للمراقبة المستمرةِ .هنالك طريقة بديلة لكشف مستويات كلوكوزِ الدمِّ بصرياً وهذه الطريقةِ تُدْعَى "النشاط بصري". تَتطلّبُ هذه الطريقةِ حسابَ زوايا الدورانِ لعدة تراكيزللدمِّ المخفف عندما يمر مصدرَ ضوء مستقطبَ من خلالِ عيّنةِ الاختبار.في هذا البحث أستخدم ليزر ذو اللون الأخضر الناتج من التوافقية الثنائية لليزر النديميوم-ياك ذو قدرة خرج بحدود 55 mW وطول موجي 532nm ,وتم قياس قدرة الليزر النافذة كدالة لزاوية الدوران من خلال مروره بعينة من الدم المخفف التي تحتوي على نسبة عالية من السكر وكذلك قياس قدرة اليزر النافذة من خلال مرورها بعينة من الدم المخفف التي تحتوي على النسبة الطبيعية للسكر وأجراء مقارنة بين الحالتين. النتائج التي حصلنا عليها في هذا البحث فتحت افاق جديدة لمراقبة السكر في الدم بحيث أنه من خلال مراقبة زوايا الدوران لعينة الدم يمكن للشخص أن يحدد بأنه مصاب بداء السكري أو لا.

Listing 1 - 8 of 8
Sort by
Narrow your search

Resource type

article (8)


Language

English (8)


Year
From To Submit

2018 (1)

2016 (2)

2014 (1)

2012 (2)

2011 (1)

More...