research centers


Search results: Found 2

Listing 1 - 2 of 2
Sort by

Article
Aerobic Granular Sludge: an Advanced Technology to Treat Oil Refinery and Dairy Wastewaters

Authors: M.A.I. Al-Hashimi --- T.R. Abbas --- G.F. Jumaha
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2017 Volume: 35 Issue: 3 Part (A) Engineering Pages: 216-221
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

Aerobic granular sludge (AGS) is an emerging and an advance technology for intensive and high-rate biological nutrient removal from wastewater that may play as important role in industrial wastewater treatment strategy in Iraq. Lab scale sequential batch reactor (SBR) operated with selected operation cycle was used to cultivate granular sludge for each of dairy and oil refinery wastewaters. Successful granulation process in each reactor was achieved after 72 day of operation. The results of experimental work proved the flexibility of AGS technology to treat refinery and dairy wastewater and withstand fluctuated load. The COD and NH4 removal efficiencies for oil refinery wastewater were 86% and 92%, respectively, with sludge volume index (SVI) of 50 ml/g and granules size distribution of (0.3-3) mm. While COD and NH4 removal efficiencies for dairy wastewater were 80% and 82%, respectively, with SVI of 70 ml/g and the large percentage of its granules were ranged between 0.3 and 0.5 mm and the other smaller percentage were ranged between 0.75 and 2 mm. In addition microbiology observations showed high diverse in microorganisms communities which indicated the presence of stabilized sludge in both reactors.


Article
Effect of Using Anaerobic Selectors on the Performance of Continuous Flow Activated Sludge Systems
تأثير استخدام الأحواض الانتقائية اللاهوائية على كفاءة أنظمة الحماة المنشطة المستمرة الجريان-عربي

Authors: Dr. Kossay K. Al-Ahmady د. قصي كمال الدين الأحمدي --- HananHaqeIsmaeel حنان حقي إسماعيل
Journal: AL Rafdain Engineering Journal مجلة هندسة الرافدين ISSN: 18130526 Year: 2013 Volume: 21 Issue: 6 Pages: 88-99
Publisher: Mosul University جامعة الموصل

Loading...
Loading...
Abstract

AbstractIn this research, four experimental plants have been constructed and operated in order to study the impact of using the anaerobic selectors on the behavior and efficiency of the extended aeration activated sludge system. The study program was divided into three stages. In the first stage, the experimental plants were run on the hydraulic retention time of the aerobic reactor equals to (32) hours, whereas, the hydraulic retention times in the biological aerobic reactors for the second and the third stages were (24 and 18) hours respectively. The results of the study revealed that; adding the anaerobic selectors improves the properties of the aerobic biological treatment in terms of removing soluble organic materials (CODs) and the efficiency of removing phosphor (PO4). The results also showed that,the organic and phosphorus removal efficiency increases with increasing the hydraulic retention time of the anaerobic selector. In contrast the values of the sludge volume index (SVI) decreases with this increasing. Higher removal efficiencies were recorded in the experimental stations that include anaerobic selector, which operates on a hydraulic retention time of (120 min) followed by the plant with the selector of (60 min) detention time and in the last place the plant that include selector, which operates on a hydraulic retention time of (30 min).Keywords:Anaerobic selector, Activated sludge, HDT,SVI, Phosphorus removal, Organic removal

الملخصتم في هذا البحث إنشاء وتشغيل محطة اختباريه تتكون من أربعة مفاعلات بيولوجية لغرض دراسة تأثير استخدامالأحواض الانتقائية اللاهوائية على سلوك وكفاءة أداء وحدات الحماة المنشطة المستمرة الجريان.قسم برنامج العمل إلى ثلاثة مراحل تم في المرحلة الأولى تشغيل الوحدات الاختبارية على وقت تعويق هيدروليكي للمفاعل الهوائي يساوي (32 ساعة)، في حين كان وقت التعويق الهيدروليكي في المفاعل البيولوجي الهوائي وللمرحلتين الثانية والثالثة مساويا لـ (24 و 18 ساعة) وعلى التوالي.أثبتت نتائج البحث إن إضافة الأحواض الانتقائية اللاهوائية يحسن من خصائص المعالجة البيولوجية الهوائية من حيث إزالة المواد العضوية الذائبة والفسفور والخصائص الترسيبية للحماة البيولوجية. كذلك أظهرت النتائج أن هناك علاقة بين زيادة وقت التعويق الهيدروليكي للحوض الانتقائي اللاهوائي وكفاءة إزالة كل من المواد العضوية والفسفور وتحسين خصائص الحمأة حيث تزداد كفاءة إزالة المواد العضوية والفسفور مع زيادة وقت التعويق الهيدروليكي للأحواض الانتقائية اللاهوائية، بالمقابل تقل قيمة معامل دليل الحماة الحجمي مع زيادة وقت التعويق الهيدروليكي للأحواض الانتقائية،حيث لوحظ أن أفضل كفاءة إزالة واقل معامل دليل حماة حجمي (SVI) تحقق في المحطة الاختبارية الحاوية على حوض انتقائي يعمل بوقت تعويق يساوي (120) دقيقة تليها المحطة الاختبارية ذات الحوض الانتقائي اللاهوائي الذي يعمل بوقت تعويق يساوي (60) دقيقة ثم المحطة ذات الحوض الانتقائي الذي يعمل بوقت تعويق يساوي (30) دقيقة.

Listing 1 - 2 of 2
Sort by
Narrow your search

Resource type

article (2)


Language

Arabic (1)

English (1)


Year
From To Submit

2017 (1)

2013 (1)