research centers


Search results: Found 5

Listing 1 - 5 of 5
Sort by

Article
Soil Site Investigations Using 2D Resistivity Imaging Technique
تحریات التربة الموقعیة باستخدام تقنیة المقاومة النوعیة التصویریة ثنائیة الأبعاد

Authors: Hussein H. Karim --- Mohammed A. Al-Neami --- Wisam M. Y. Mohammad
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2013 Volume: 31 Issue: 16 Part (A) Engineering Pages: 3125-3146
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

The use of 2D Electrical Resistivity Imaging (ERI) technique in combination withgeotechnical and geological data allow the determination of the lithologicalcomposition and detailed internal architecture of the subsurface and understanding thecharacterisation and description of the geology of the site. This study is aimed toevaluate the use of 2D ERI for the detection and characterisation of heterogeneities insubsurface soil. The survey was conducted using a Wenner-Schlumberger and Wennerconfigurations along thirteen ERI parallel profiles which have been investigated in theproject of Al-Obaidi Electrical Transformation Station site to find the resistivity anddepth of soil horizons with their lithological description. Analysis of imaging sectionsshows that Wenner-Schlumberger sections are with higher resolving power thanWenner sections in both horizontal and vertical variations in resistivity reflecting morepronounced soil horizons with depth, where Wenner sections are limited to the uppersoil layers. Resisitvity values in the imaging sections indicate that the stratigraphy ofthe study area is mostly of clayey soil. 4 to 7 distinct geoelectric layers generallyidentify the subsurface down to depth of about 20 m. High resistivity values in the topsoil, medium-high resistivity values representing the upper soil layers, while lowerreistivity values are indicated for the lowerest layers. The resistivity values areinversely proportional to many soil properties such as fine content (clay and silt), saltcontent (sulphate and gypsum content) for saturated conditions, water content,plasticity index (P.I) and void ratio particularly for saturated condition. The resistivityvalues are directly proportional to sand content, void ratio, salt contents for drycondition. The integrated use of ERI technique and conventional site investigation hasled to a far better understanding of the site than could have been achieved using siteinvestigation methods alone.


Article
Characteristics of 2-D Electrical Resistivity Imaging Survey for Soil
خصائصية المسح التصويري ثنائي الأبعاد للمقاومة النوعية الكهربائية للتربة

Authors: Hussein H. Karim --- . Imzahim Abdul Kareem Alwan --- Mohammed A. Al-Neami
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2013 Volume: 31 Issue: 19 Part (A) Engineering Pages: 70-89
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

The present work is aimed to show the efficiency of 2-D Electrical Resistivity Imaging (ERI) in probing the subsurface soil for site investigation, in addition to highlight some capabilities and characteristics of the sections acquired by 2D-ERI survey. In the field survey, where the University of Technology site is chosen for such investigation, ERI technique has been used implementing three common arrangements (Wenner, Wenner-Sclumberger and dipole-dipole). Different resolving powers have been obtained for the used arrays. Wenner-Schlumberger array gives moderate number of possible measurements and has a median depth of investigation of about 10% larger than that for the Wenner array. It is moderately sensitive to both horizontal and vertical structures, thus it might be a good compromise between the Wenner and the dipole-dipole arrays. Good agreements have been obtained between the stratigraphic columns of the site with the inversion models using the different arrays. The distribution of resistivity of the inversion models for the study site reflects the highly inhomogeneous subsurface soil with a wide variation of soil resistivity at different depths.

يهدف العمل الحالي إلى إظهار كفاءة تقنية المقاومة النوعية الكهربائية التصويرية ثنائية الأبعاد (2D-ERI) في فحص التربة تحت السطحية للتحري الموقعي، بالإضافة إلى تسليط الضوء على بعض قدرات وخصائص المقاطع التصويرية التي تم الحصول عليها بواسطة المسح الكهربائي ثنائي الأبعاد ((2D-ERI. في المسح الحقلي, حيث أختير موقع الجامعة التكنولوجية لهذا التحري, حيث استخدمت تقنية (ERI) بتنفيذ ثلاثة ترتيبات شائعة (فنر و فنر-شلمبرجر وثنائي القطب-ثنائي القطب). تم الحصول على قوى تحليلية مختلفة باستخدام هذه الترتيبات.أعطى ترتيب فنر- شلمبرجر عدد معتدل من القياسات الممكنة وبمعدل عمق للتحري أكبر بحوالي 10٪ مما هو لترتيب فينر. كما انه حساس بدرجة متوسطة للتراكيب الأفقية والعمودية, وبالتالي قد يكون حلا وسطا جيدا بين ترتيبي فينر و ثنائي القطب- ثنائي القطب. تم الحصول على اتفاقات جيدة بين العمود الطباقي للموقع مع نماذج الانعكاس باستخدام الترتيبات المختلفة. عكس توزيع المقاومة من نماذج الانعكاس لموقع الدراسة التربة تحت السطحية غير المتجانسة للغاية مع تباين واسع للمقاومة النوعية للتربة في الأعماق المختلفة.


Article
Differentiating Clayey Soil Layers from Electrical Resistivity Imaging (ERI) and Induced Polarization (IP)
تمییز طبقات التربة الطینیة من المقاومة النوعیة الكھربائیة (ERI) التصویریة (IP) والاستقطاب المستحث

Authors: Nadia A. Aziz --- Mahmoud R. AL- Qaissy --- Hussein H. Karim
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2013 Volume: 31 Issue: 17 Part (A) Engineering Pages: 3216-3234
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

Electrical Resistivity Imaging (ERI) method is one of the most promisingtechniques which is well suited for the applications in the fields of geohydrology,environmental science and engineering. The present work is aimed to show theefficiency of 2D Electrical Resistivity Imaging (ERI) and Induced Polarization (IP) inprobing the subsurface soil for site investigation and differentiating the clayey soillayers as it is a common practice to measure the IP sounding along with resistivity forcorrect interpretation of field data. The study has demonstrated the practicalapplication of 2D ERI and IP tomography along 7 lines using Wenner- Schlumbergerarray. The data analysis comprises of 2D inversions using the RES2DINV software,thus 2D electrical resistivity and IP imaging sections have been obtained. The depth ofinvestigation was 4 m, and resistivity values range from <1 to 292 ohm.m. Twoelectrical layers were recognized: the upper layer with high resistivity (7-71 ohm.m)represents the loamy soil extends to a depth around 1.3 m; and the second layer withlow resistivity (<1-9 ohm.m) represents the clayey layer. Some anomalous low andhigh electric zones are appeared reflecting the inhomogeneity in deposits. The IPvalues are ranging from -2 to 17 mV/V showing good confirmation with resistivitydata, where high chargeability are associated with low resistivity. The study revealsthat combining IP with resistivity surveys is recommended since IP is, sometimes, veryeffective in relieving ambiguity in interpretation.


Article
2D and 3D Resistivity Imaging for Soil Site Investigation
المقاومة النوعیة التصویریة ثنائیة وثلاثیة الأبعاد للتحري الموقعي للتربة

Authors: Hussein H. Karim --- Mahmoud R. AL- Qaissy --- Nadia A. Aziz
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2014 Volume: 32 Issue: 1 Part (A) Engineering Pages: 249-272
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

Electrical Resistivity Imaging (ERI) method is one of the most promisingtechniques which is well suited to applications in the fields of geohydrology,environmental science and engineering. The present work is aimed to show the efficiency of 2D Electrical Resistivity Imaging (ERI) and Induced Polarization (IP) in probing the subsurface soil for site investigation and differentiating the clayey soil layers as it is a common practice to measure the IP sounding along with resistivity forcorrect interpretation of field data. The study has demonstrated the practical application of 2D ERI and IP tomography along 7 lines using Wenner- Schlumberger array. The data analysis comprises of 2D inversions using the RES2DINV software, thus 2D electrical resistivity and IP imaging sections have been obtained. The depth of investigation was 4 m, and resistivity values range from <1 to 292 ohm.m. Two electrical layers were recognized: the upper layer with high resistivity (7-71 ohm.m)represents the loamy soil extends to a depth around 1.3 m; and the second layer with low resistivity (<1-9 ohm.m) represents the clayey layer. Some anomalous low and high electric zones are appeared reflecting the inhomogeneity in deposits. The IP values are ranging from -2 to 15 mV/V showing good confirmation with resistivity data, where high chargeability are associated with low resistivity. The study reveals that combining IP with resistivity surveys is recommended since IP is, sometimes, very effective in relieving ambiguity in interpretation.


Article
USING VERTICAL ELECTRICAL SOUNDING IN BUILDING SITES INVESTIGATION; A CASE STUDY IN SOUTH OF BAGHDAD, IRAQ
استعمال التحري الكهربائي العمودي لدراسة مواقع إنشائية؛ دراسة حالة، جنوب بغداد، العراق

Authors: Jassim M. Thabit جاسم محمد ثابت --- Ahmed S. Al-Banna أحمد شهاب البناء --- Mundher D. Al-Awsi منذر ظاهر نصيف الأوسي
Journal: Iraqi Bulletin of Geology and Mining مجلة الجيولوجيا والتعدين العراقية ISSN: 18114539 Year: 2016 Volume: 12 Issue: 1 Pages: 31-39
Publisher: Ministry of Industry and Minerals وزارة الصناعة والمعادن

Loading...
Loading...
Abstract

Vertical Electrical Sounding is used for engineering purposes at Al-Jadiriya area, within Baghdad University site .Two different electrical resistivity techniques were applied using Schlumberger array. These are the vertical electrical sounding (VES) and cross vertical electrical sounding (CVES) technique. The measurements of VES were carried out at 38 points distributed as much as possible to cover the area. Three main layers were delineated; these are the top soil, unsaturated layer of clayey sand or silty sand and saturated layer of sand to clayey sand and sand mixed with gravel at some places. The resistivity of the top soil varies from 11 – 600 ohm.m, and thickness ranges from 0.7 – 2.8 m. The unsaturated layer has resistivity values varying from 46 – 320 ohm.m, and thickness ranging from 2.0 – 7.2 m. The resistivity of the saturated layer varies from 11 – 60 ohm.m, and thickness ranges from 4.6 – 13.8 m. There are also lenses in some places within the layers, 1.2 – 2.45 m. thick, which have high resistivity 800 – 900 ohm.m or low resistivity 9.6 – 29 ohm.m that may represent fill material and clay lenses respectively. The average depth of the groundwater surface ranges between 5 – 8 m. The measurements of CVES were taken along two perpendicular directions around fixed central point, at 5 points. The results are presented as radial graphs to show the variation of resistivity with direction; these graphs show that the sediments are heterogeneous in their vertical and horizontal distribution; especially for the top soil. Finally, it is concluded that three major causes of failures prevail in the buildings in Baghdad University. The first cause is the lateral inhomogeneity of the subsurface sediments. The second is the presence of lenses, and the third is the variation in the groundwater level. These failures may cause many engineering problems such as cracks in the foundation and walls of buildings.

استخدم الجس الكهربائي العمودي للأغراض الهندسية في منطقة الجادرية (موقع جامعة بغداد). إذ تم تطبيق اسلوبين هما الجس الكهربائي العمودي والجس الكهربائي العمودي المتقاطع، وباستعمال ترتيب شلمبرجر للأقطاب في 38 نقطة جس موزعة في منطقة الدراسة قدر المستطاع. واستخدم أسلوب الجس المتقاطع في خمسة مواقع ضمن منطقة الدراسة للتعرف على طبيعة تجانس الرواسب، حيث أجريت القياسات الكهربائية باتجاهين مختلفين لهما نفس مركز الترتيب. أظهرت المقاطع الجيوكهربائية وجود اربعة أنطقة كهربائية.النطاق الأول يمثل الطبقة السطحية التي تتألف من ترسبات الطين أو الغرين وبنسب مختلفة، والحاوية في بعض الأحيان على الرمل أو بقايا مواد البناء، تتراوح المقاومة النوعية لهذا النطاق من 600 – 11 اوم.متر، اما سمكه فيتراوح من 2.8 – 0.7 متر. النطاق الثاني يظهر بشكل عدسات غير مستمرة ويتراوح سمكة من 2.45 – 1.2 متر. أما مقاومتة النوعية فقد كانت منخفضة في بعض المواقع حيث تراوحت من 29 – 9.6أوم.متر وتشير إلى الترسبات الطينية الحاوية على نسبة قليلة من الرمل في بعض الأحيان. وفي بعض المواقع الأخرى تراوحت مقاومتها النوعية من 950 – 800 أوم.متر وهذه تشير إلى عدسات من الحصى أو بقايا مواد الدفن. ويمثل النطاق الثاني نطاق الترسبات الرملية غير المشبعة بالمياه الجوفية والحاوية على نسب مختلفة من الغرين أو الطين، وتتراوح مقاومتة النوعية من 320 – 46 أوم.متر، أما السمك فيتراوح بين 7.2 – 2 متر. النطاق الرابع يمثل نطاق المياه الجوفية في منطقة الدراسة ويتألف من الرمل الحاوي على نسب مختلفة من الغرين أو الرمل الحاوي على الطين، ومن المحتمل أن يكون حاوي على القليل من الحصى الناعم في بعض المواقع. تراوحت مقاومته النوعية من 60 – 11 أوم.متر، أما سمكه فيتراوح بين 13.8 – 4.6 متر. وتبين إن رواسب منطقة الدراسة غير متجانسة في خصائصها وفي توزيعها الأفقي والعمودي وذلك بناءاً على نتائج الجس الكهربائي العمودي المتقاطع. كذلك أظهرت المقاطع الجيولوجية عدم استمرارية الرواسب وتواجدها بشكل عدسات تتغير من موقع لآخر وضمن مسافات قليلة خاصة نطاق الطبقة السطحية وترسبات الرمل الطيني. وأظهرت منطقة الدراسة الوسطى عدم تجانس واضح في خواص ومكونات الترسبات الرملية غير المشبعة بالمياه الجوفية، حيث يكثر وجود الترسبات الرملية ذات المحتوى المائي القليل والحاوية على نسب متغيرة من الغرين، في حين تنتشر الترسبات الرملية الحاوية على الطين أو الرطوبة في الشمال الشرقي والجنوب الغربي. لذلك يعتقد بأن تشقق جدران بعض البنايات سببة تأثير عدم تجانس الرواسب حيث يؤدي ذلك إلى حدوث تجلس متباين في التربة التي تقام عليها البنايات، بالإضافة إلى تأثير ارتفاع منسوب المياه الجوفية في مواقع هذه البنايات ووجود تذبذب في منسوب هذه المياه.

Listing 1 - 5 of 5
Sort by
Narrow your search

Resource type

article (5)


Language

English (5)


Year
From To Submit

2016 (1)

2014 (1)

2013 (3)