research centers


Search results: Found 46

Listing 1 - 10 of 46 << page
of 5
>>
Sort by

Article
Experimental and Theoretical Study of a Parabolic Trough Solar Collector
دراسة عملية ونظرية لمجمع شمسي ذي القطع المكافىء

Author: Tadahmun Ahmed Yassen تضامن احمد ياسين
Journal: Anbar Journal of Engineering Sciences مجلة الأنبار للعلوم الهندسية ISSN: 19979428 Year: 2012 Volume: 5 Issue: 1 Pages: 109-125
Publisher: University of Anbar جامعة الانبار

Loading...
Loading...
Abstract

An experimental and theoretical study has been conducted to determine the thermal efficiency of a parabolic trough solar collector. The experiments have been performed during winter and summer at Tikrit-Iraq. The solar radiation of Tikrit University was calculated theoretically and a theoretical study was performed by using FORTRAN 90 program. The dimensions and specifications of the collector were entered to the program to determine the theoretical thermal efficiency. It has been found the experimental thermal efficiency of collector is less than the theoretical one in percentage between (7-15) .So the increase in water mass flow rate leads to an increase in the thermal efficiency, and there is no significant change in thermal efficiency when the water mass flow rate becomes more than forty kilograms per hour.

درس عمليا ونظريا مجمع شمسي ذي القطع المكافىء لحساب الكفاءة الحرارية. انجزت الدراسة العملية خلال فصل الصيف والشتاء في مدينة تكريت في العراق. الاشعاع الشمسي لمدينة تكريت حسب نظريا. الدراسة النظرية انجزت باستخدام برنامج الفورتران 90 .مواصفات وابعاد المجمع ادخلت الى البرنامج لحساب الكفاءة الحرارية النظرية. وجد ان الكفاءة الحرارية العملية للمجمع اقل من الكفاءة الحرارية النظرية بنسبة تتراوح ما بين (7-15) بالمئة، كذلك وجد ان الزيادة بتدفق الكتلي للماء تقود الى الزيادة بالكفاءة الحرارية ولا يوجد تغير بالكفاءة الحرارية عندما يزيد التدفق الكتلي للماء عن اربعين كيلوا غرام بالساعة.


Article
Design and Implementation of an Automatic Control for Two Axis Tracking System for Applications of Concentrated Solar Thermal Power
تَصميم وتنفيذ تَحكّم آلي لمنظومة تَتبع ذاتُ محورين لتطبيقات الطاقة الحرارية الشمسية المُرَّكزة

Loading...
Loading...
Abstract

The present work presents design and implementation of an automated two-axis solar tracking system using local materials with minimum cost, light weight and reliable structure. The tracking system consists of two parts, mechanical units (fixed and moving parts) and control units (four LDR sensors and Arduino UNO microcontroller to control two DC servomotors). The tracking system was fitted and assembled together with a parabolic trough solar concentrator (PTSC) system to move it according to information come from the sensors so as to keep the PTSC always perpendicular to sun rays. The experimental tests have been done on the PTSC system to investigate its thermal performance in two cases, with tracking system (case 1) and without tracking system (case 2). The experimental results showed that the average solar radiation falling on the PTSC prototype in the two cases during the same time was 854 and 701 watt/m2, respectively, which means an increase in the solar radiation about 21.8 % when using tracking system. It was found that the average useful heat gain output of solar collector was equal to (376.2, 252.6 watt) for the two cases, respectively, so there was an increase of about 48.9 % when using the tracking system. Also, the average thermal efficiency of the PTSC was found to be (20.7, 26.5 %) for the two cases, respectively, which means an increase in the average efficiency by 28% with use of tracking system compared to the fixed case.

يُمثل العمل الحالي تصميم و منظومة تتبع شمسي ذاتية الحركة ذات محوريين بأستخدام مواد محلية وتنفيذها بأقل كلفة وأخف وزناً وموثوقية بناء. منظومة التتبع تتألف من جزأين: الوحدات الميكانيكية (الأجزاء الثابتة والمتحركة) ووحدات التحكم الكهربائية (من اربعة متحسسات ضوئية من نوع LDR ومسيطر دقيق نوع أردوينو الذي يقوم بالسيطرة على محركيين نوع ذاتي الحركة يعملان بالتيار المستمر) . إنّ منظومة التتبع ثنائية المحاور تأتي متُلائمة ومُجمتعة سوية مع المُركّز الشمسي ذي القطع المكافىء لتحريك المُركز وبحسب المعطيات القادمة من المتحسسات الضوئية لكي تُبقى المُركز الشمسى بشكل دائم عمودياً على الاشعة الساقطة من الشمس .أجريت الأختبارات التجربية على المُركز الشمسي لتقويم الأداء الحراري في حالتين: (الحالة الأولى) بأستخدام منظومة التتبع الشمسي و(الحالة الثانية) عند عدم استخدامها. بَيّنت النتائج التجريبية المستحصلة بأن مُعدل أشعة الشمس الساقطة على المُركز الشمسي في الحالتين هي على التوالي (854 واط/متر2 و 701 واط/متر2) وهذا يعني زيادة في معدل الأشعاع الشمسي حوالى 21.8 % عند استخدام منظومة التتبع. لقد وُجدَ بأن معدل الحرارة المفيدة المكتسبة للمُركز الشمسي للمدة نفسها وللحالتين أعلاه هي على التوالي (376.2 واط و 252.6 واط) وهذا يعني زيادة حوالى 48.9 % عند استخدام منظومة التتبع وكما وجد بأن مُعدل الكفاءة الحرارية للمُركز الشمسي في حالتي التتبع كانت على التوالي (26.5% و 20.7%) وهذا يعني زيادة بمقدار 28 % عند استخدام منظومة التتبع ثنائي المحاور بالمقارنة مع المنظومة الثابتة.


Article
Front Window Heat Loss From Different Material of Flat Plate Collector
الفقدان الحراري من الجهة الأمامية لصفائح مختلفة للسخان الشمسي

Author: Luma Mohammad Ali لمى محمد علي
Journal: Tikrit Journal of Pure Science مجلة تكريت للعلوم الصرفة ISSN: 18131662 Year: 2012 Volume: 17 Issue: 4 Pages: 169-173
Publisher: Tikrit University جامعة تكريت

Loading...
Loading...
Abstract

The present paper includes a theoretical study concerning front window heat loss of a single glazing flat plate collector, for different emissivity (e) of material (black chrome , black paint copper and black paint aluminum) and ambient temperature (Ta). A computer program is devised to find a relationship between heat loss through the glass cover and collection plate temperature. Computed data are fitted to 4th order polynomial equation include a constant coefficients shown in table (1) for application convenience.

يتضمن البحث دراسة نظرية حول الفقدان الحراري لصفيحة السخان الشمسي مغطاة بطبقة زجاجية واحدة ولمواد مختلفة الإنبعاثية (المواد المطلية بالصبغة السوداء وهي الكروم،النحاس والألمنيوم) ودرجة حرارة المحيط. صمم برنامج على الآلة الحاسبة لإيجاد العلاقة بين الفقدان الحراري من خلال الغطاء الزجاجي ودرجة حرارة الصفيحة الجامعة. أدخلت القيم المستحصلة في معادلة متعددة الحدود من الدرجة الرابعة تتضمن ثوابت موضحة في جدول رقم (1) لاستخدامها في تطبيقات مناسبة.


Article
AN EXPERIMENTAL STUDY FOR A NEW DESIGN OF A STORAGE SOALR COLLECTOR
دراسة عملية لمجمع شمسي خازن ذو تصميم جديد

Authors: Khalid Ahmed Joudi خالد احمد جودي --- Imad Ahmed Hussein عماد احمد حسين --- Omer Khalil Ahmed عمر خليل احمد
Journal: AL-TAQANI مجلة التقني ISSN: 1818653X Year: 2014 Volume: 27 Issue: 4 Pages: E76-E88
Publisher: Foundation of technical education هيئة التعليم التقني

Loading...
Loading...
Abstract

An experimental study was carried out on a new design of a storage solar collector to verify its suitability for domestic use. The storage collector can be used as storage water tanks to replace the ordinary cubical or cylindrical tank commonly used in Iraqi houses. Experiments were carried out for both summer and winter weather conditions with and without hot water removal. The hourly system performance parameters were investigated systematically for all test conditions. These included the mean storage temperature and total stored energy. The day-long collection efficiency of the triangular collector under no load condition in winter (13-November-2004) was found to be 48.7% for a maximum mean storage temperature of 40.5 oC and a maximum hot water temperature at the tip of the collector of 65 oC. In summer (9-July-2004), the day-long collection efficiency was found to be 62.2% for a maximum mean storage temperature of 57 oC and a maximum hot water temperature of 70 oC. At continuous loading, the collection efficiency was 55.7% in winter, and 65.1% in summer. Also, in winter the maximum difference between the outlet and inlet water temperatures were 12 oC at 2 p.m. and 9 oC at the end of the day

يتضمن البحث دراسة عملية لتصميم جديد لمجمع شمسي خازن وتحقيق ملاءمته للاستخدامات المنزلية. يمكن استخدام المجمع الشمسي المقترح كخزان ماء بدلا من الخزانات المعتادة المكعبة أو الأسطوانية الشكل المستخدمة في البيوت العراقية. أجريت سلسلة تجارب منتظمة لدراسة أداء هذه المنظومة خلال فصلي الشتاء والصيف و بظروف تحميل و كذلك بدون تحميل وتم تحليل هذا الأداء لمختلف الظروف. تمت دراسة تأثير المتغيرات الأساسية على أداء المجمع الشمسي الخازن والتي تضمنت متوسط درجة حرارة الخزين وكفاءة المجمع. بلغت كفاءة المجمع الإجمالية بدون تحميل 48,7% لفصل الشتاء (13- تشرين الثاني -2004) بينما بلغت متوسط درجة حرارة الخزين العظمى حوالي 40.5 درجة مئوية و في فصل الصيف (9-تموز-2004) بلغت الكفاءة الإجمالية 62,2% وكان متوسط درجة حرارة الخزين العظمى نحو 57 درجة مئوية. في حالة التحميل المستمر بلغت الكفاءة 55,7% و 65,1% لفصلي الشتاء والصيف على التوالي وكان الفرق بين درجة حرارة الدخول والخروج في فصل الشتاء حوالي 12 درجة مئوية عند الثانية بعد الظهر و 9 درجة مئوية عند نهاية اليوم.


Article
Experimental Investigation Of An Evacuated-Tube Solar Water Collector With Serpentine Through-Flow Pipe
دراسة تجريبية لمجمع شمسي مائي ذو الأنابيب المفرغة ومزود بأنبوب ناقل من النوع الملتوي

Authors: Aouf A. Al-Tabbakh عوف عبد الرحمن احمد الطباخ --- Amer A. Mohammed عامر عبد الله محمد
Journal: Journal of Engineering and Sustainable Development مجلة الهندسة والتنمية المستدامة ISSN: 25200917 Year: 2014 Volume: 18 Issue: 2 Pages: 122-132
Publisher: Al-Mustansyriah University الجامعة المستنصرية

Loading...
Loading...
Abstract

The present work deals with experimental study of an evacuated-tube (all-in-glass) solar collector. The collector consists of 5 evacuated tubes filled with ordinary engine oil. An additional stainless steel pipe is integrated with the tubes to carry the working fluid (water). The steel pipe (through-flow pipe) is bent 5 times to form 5 U-shape turns. Each U-turn is immersed in a single evacuated tube. Oil acts as the heat transfer medium between tube inner surface and the stainless steel pipe outer surface. Experiments are carried out for several values of water mass flow rate and under various meteorological conditions (irradiance, ambient temperature). Results show that the collector exhibits high conversion efficiency and fast response to the affecting parameters (water inlet temperature changes, clouding, replacement of oil) compared to conventional flat-plate collectors. However, the limited number of tubes and the small diameter of the stainless steel pipe combined with its large length (14 m) caused some fluctuations in the water flow rate at the pipe exit. To enhance the performance of the system and make it suitable for higher loads (e.g. for producing superheated steam) the number of evacuated tubes should be increased and the stainless steel pipe diameter is increased and its length decreased.

يتناول البحث الحالي دراسة تجريبية لمجمع شمسي ذو الأنابيب المفرغة. يتكون المجمع من خمسة أنابيب مملوءة بزيت المحركات. كما يحتوي المجمع على أنبوب ناقل للمائع الشغال (الماء) يخترق تجاويف الأنابيب المفرغة الخمسة. ولكي يتم ذلك تم لي الأنبوب الناقل في خمس مناطق وعلى مسافات متساوية للحصول على خمس التواءات بشكل حرف U بحيث يدخل كل جزء ملتوي في واحد من الأنابيب المفرغة الخمسة.يعمل الزيت داخل تجاويف الأنابيب كوسيط لانتقال الحرارة بين السطح الداخلي للأنبوب المفرغ والسطح الخارجي للأنبوب الناقل.تم إجراء التجارب لقيم مختلفة من معدل جريان الماء وفي ظروف جوية مختلفة. وقد بينت النتائج كفاءة تحويل عالية للمجمع واستجابة سريعة لظروف التشغيل المختلفة والتي تشمل درجة حرارة الدخول للماء أو وجود الغيوم أو استبدال الزيت, مقارنة مع الأنواع التقليدية من المجمعات الشمسية المسطحة.ولكن نظرا لمحدودية عدد الأنابيب المفرغة والقطر الصغير للأنبوب الناقل مقرونا بطوله الكبير البالغ 14 مترا فقد عانت المنظومة من تذبذب في معدل الجريان الخارج من الأنبوب الناقل. ولذلك ومن اجل تحسين أداء المجمع وجعله مناسبا لأحمال حرارية أعلى قد تمكن من استعماله مولدا للبخار فيجب زيادة عدد الأنابيب المفرغة وزيادة قطر الأنبوب الناقل وتقليل طوله.


Article
COMPARISON BETWEEN SIMULATED AND CALCULATED POWER OF THE SOLAR CHIMNEY WITH BLACK CONCRETE BASE USING ANSYS PROGRAM
مقارنة بين القدرة النظرية والمحسوبة لمدخنة شمسية ذات قاعدة كونكريتية سوداء بأستخدام برنامج ANSYS

Loading...
Loading...
Abstract

A solar chimney has been analyzed by solving its governing equations and compare with the simulated results. The solar absorbent of the chimney is selected as a black painted concrete, which is useful as an energy saver at night. The numerical simulation using ANSYS, based on solving the governing equations with suitable assumptions and boundary conditions for many variables such as the collector area, the chimney height, the ambient temperature, and the exit area of the chimney. The results shows that the chimney height and base area are very important parameters for improving the gained power, and it is also important to choose the region with suitable mean ambient temperature. And economically there are limitations to collector and chimney sizes to get suitable profit output power and any increment in system size becomes a small percentage increment in profit output power. The results compared with some experimental data from other results researchers and there is a good agreement between simulated and calculated results

تم تحليل المدخنة الشمسية عن طريق حل المعادلات الحاكمة ومقارنة النتائج مع نتائج المحاكاة. إن اللوح الماص للمدخنة الشمسية تم اختياره من الكونكريت المطلي باللون الاسود والذي يعتبر مفيدا لخزن الحرارة ليلا. إن المحاكاة العددية باستخدام برنامج ANSYS 11.0 تم بناءه على حل المعادلات الحاكمة مع الفرضيات والشروط الحدية المناسبة لعدة متغيرات مثل مساحة المجمع ارتفاع المدخنة ودرجة حرارة المحيط و مساحة مخرج المدخنة. أظهرت النتائج أن ارتفاع المدخنة ومساحة المجمع هي عوامل مهمة جدا لتحسين القدرة الناتجة، وكذلك من المهم اختيار المنطقة بمعدل درجة حرارة محيط مناسبة.وان هناك محددات اقتصادية لحجم المدخنة والمجمع الشمسي للحصول على قدرة خارجة مناسبة وان أي زيادة في الحجم يقلل من نسبة الزيادة في القدرة الخارجة المفيدة. ناظرت النتائج في هذا البحث مع بعض النتائج التجريبية لباحثين آخرين وان هناك تقاربا جيدا بين نتائج الحسابات والمحاكاة .


Article
Parabolic Trough Solar Collector – Design, Construction and Testing
تصميم وتركيب واختبار مركز شمسي حوضي ذو قطع مكافىء

Loading...
Loading...
Abstract

This paper presents the design, construction and investigates an experimental study of a parabolic Trough Solar Collector (PTSC). It is constructed of multi – piece glass mirror to form the parabolic reflector (1.8 m  2.8 m) its form were checked with help of a laser and carbon steel rectangular as receiver. Sun tracker has been developed (using two – axis) to track solar PTSC according to the direction of beam propagation of solar radiation. Using synthetic oil as a heat transfer its capability to heat transfer and load high temperature (400 oc). The storage tank is fabricated with stainless steel of size 50 L. The experimental tests have been carried out in Baghdad climatic conditions (33.3o N, 44.4o E) during selective days of the months October and November. The performance of PTSC is evaluated using outdoor experimental measurements including the useful heat gain, the thermal instantaneous efficiency and the energy gained by the storage tank oil. The storage tank oil temperature is increased from 30oc at 9:30h to 136oc at 13:30h without draw – off oil. The experimental result shows the average thermal efficiency was 42% which is fairly acceptable assessment results of a PTSC locally.

هذا البحث يمثل دراسة عملية لمركز شمسي اسطواني ذو قطع مكافئ وجهاز التوجيه الشمسي تم تصميمهم وتصنيعهم باستخدام التقنيات العراقية والمواد المتاحة محليا. وقد صنع مركز شمسي بمساحة كلية بلغت 5.4 m2 وقد تم ترتيب قطع المرايا بعرض 5cm على السطح الداخلي للمركز حيث استخدمت كسطح عاكس للاشعة . صنع الجزء المستلم من معدن الفولاذ الكاربوني كسطح امتصاص واستخدم زيت المكائن الصناعي كوسط ناقل للحرارة لما يمتاز به من قابلية على نقل الحرارة وتحمله لدرجات حرارة عالية. زودت المنظومة بخزان ووضع داخل الخزان زيت ذو سعة 50 L لخزن الطاقة الحرارية , جهاز التوجيه الشمسي من العناصر الكهربائية والالكترونية بمحورين في اقتفاء الاشعاع الشمسي المباشر. التجارب العملية تم انجازها تحت الظروف المناخية لمدينة بغداد خلال شهري تشرين الاول والثاني , خلال هذه التجارب بلغت اقصى درجة حرارة خروج الزيت من المستلم 150oC اما درجة حرارة الزيت داخل الخزان زادت من 30oC الى 136oC خلال اربع ساعات تشغيل. اظهرت النتائج العملية ان معدل كفاءة المنظومة كانت 42% وهي مقبولة باعتبار ان هذه المحاولة الاولى لتصنيع مثل هذا المجمع محليا.


Article
Design Of A solar Dryer Provided With Back And Heating systems And Its Testing In The Drying Of Fishes And meats
تصميم مجفف شمسي مزود بمنظومتي الراجع والتسخين واختباره في تجفيف الاسماك واللحوم

Author: Asaad R. AL-Hilphy Ghyath.H.majeed
Journal: Journal of Basrah Researches (Sciences) مجلة ابحاث البصرة ( العلميات) ISSN: 18172695 Year: 2007 Volume: 33 Issue: 3B Pages: 20-30
Publisher: Basrah University جامعة البصرة

Loading...
Loading...
Abstract

A solar dryer was designed for fish and meat drying . Its consist of solar collector with ribbed absorbent plate , its dimensions 1*0.5 m2 and drying chamber contains ten beds , plastic pipe that humid air carry to the head of solar collector and small kerosene cooker under drying chamber .The results showed that the solar dryer enable usage in the winter and summer semesters, rainy and cloudy days for drying fishes and meats .The consumption time to drying , drying efficiency , rate of dehydration , drying rate and mean of humidity reducing higher than usage of natural sun drying . And showed the results the drying rate for fish and meat was multi stage for two methods of drying, exception dried fish by natural sun drying. .

تم تصميم مجفف شمسي للاسماك واللحوم سعته 25 كغم يتكون من مجمع شمسي ذي صفيحة امتصاص مضلعة ابعادها 0.5*1 م وغرفة تجفيف تحتوي على عشرة اطباق وانبوب بلاستيكي ينقل الهواء المحمل بالرطوبة الى مقدمة المجمع الشمسي وطباخ نفطي صغير اسفل غرفة التجفيف .اظهرت النتائج امكانية استعمال المجفف الشمسي في فصلي الصيف والشتاء وكذلك في الايام الغائمة والممطرة في تجفيف الاسماك واللحوم . كما ان الزمن المستغرق للتجفيف وكفاءة التجفيف ونسبة استرجاع الماء ومعدل التجفيف ومعدل انخفاض الرطوبة باستعمال ذلك المجفف الشمسي كانت اعلى من تلك عند استعمال التجفيف الشمسي الطبيعي .كما بينت النتائج ان معدل التجفيف للسمك واللحم كان من نوع متعدد المراحل ولكلا طريقتي التجفيف ماعدا السمك في حالة التجفيف الشمسي الطبيعي.


Article
Study on the Effect of the Curvature of Solar Collector on Wind Loading Coefficients and Dynamic Response of Solar Collector
دراسة تأثير انحناء المجمع الشمسي على الاستجابة الديناميكية للمجمع الشمسي

Authors: Khalid Hameed Hussein خالد حميد حسين --- Aladine Abdulkader Kazem علاءالدين عبد القادر
Journal: Al-Khwarizmi Engineering Journal مجلة الخوارزمي الهندسية ISSN: 18181171 23120789 Year: 2013 Volume: 9 Issue: 2 Pages: 21-32
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

In the current research, the work concentrated on studying the effect of curvature of solar parabolic trough solar collector on wind loading coefficients and dynamic response of solar collector. The response of collector to the aerodynamic loading was estimated numerically and experimentally. The curvature of most public parabolic trough solar collectors was investigated and compared. The dynamic response of solar collector due to wind loading was investigated by using numerical solution of fluid-structure interaction concept. The experimental work was done to verify the numerical results and shows good agreement with numerical results. The numerical results were obtained by using finite element software package (ANSYS 14). It was found that the change in collector curvature (focal length) lead to remarkable changes in wind loading coefficients (drag, lift, and moment), dynamic response (displacement) and natural frequencies but does not affect the first mode shape.

في هذا البحث, تركز العمل على دراسة تاثير انحناء المجمع الشمسي ذو المقطع بشكل قطع مكافئ على معاملات الاحمال الهوائية والاستجابة الديناميكية للمجمع الشمسي.تم ايجاد استجابة المجمع لتاثير الاحمال الهوائية عدديا وعمليا. تمت دراسة انحناء اكثر المجمعات الشمسية استخداما في العالم وتمت المقارنة بينها. تمت دراسة الاستجابة الديناميكية للمجمع الشمسي باستخدام الحل العددي لمفهوم تفاعل المائع-الهيكل. تم اجراء الجانب العملي للتحقق من دقة النتائج العددية وقد اظهرت النتائج العملية تقاربا جيدا مع النتائج العملية. النتائج العددية استخرجت باستخدام طريقة العناصر المحددة عن طريق برنامج المحاكاة الحاسوبي ANSYS 14 . لقد وجد ان تغيير تقوس المجمع الشمسي (البعد البؤري) ادى الى تغيرات واضحة في قيمة الاحمال الهوائية (الكبح، الرفع والعزم)، الاستجابة الديناميكية (الازاحة) وكذلك الترددات الطبيعية ولكن نسق الاهتزاز الاول لم يتأثر .


Article
Construction and performance study of a solar - powered hybrid cooling system in Iraq
تقييم أداء منظومة تبريد هجينة تعمل بالطاقة الشمسية وفق الأجواء العراقية

Loading...
Loading...
Abstract

The systems cooling hybrid solar uses solar collector to convert solar energy into the source of heat for roasting Refrigerant outside of the compressor and this process helps in the transformation of Refrigerant from the gas to a liquid state in two-thirds the top of the condenser instead of two-thirds the bottom of the condenser as in Conventional cooling systems and this in turn reduces the energy necessary to lead the process of cooling. The system cooling hybrid use with a capacity of 1 ton and Refrigerant type R22 and the value of current drawn by the system limits (3.9-4.2A), the same value of electric current calculated by the system are Conventional within this atmosphere of Iraq, and after taking different readings of the temperatures and pressure to several points in the system's found that the Refrigerant when it comes out of the compressor, it loses part of the temperature of the water in the solar collector through a heat exchanger while the literature published in accordance with the manufacturers that the solar collector, a kind of vacuum tubes contributes to raise the pressure and temperature of the fluid cooler to reduce the consumption of energy spent on compressor. Therefore, the system described by the current not fit for domestic use within the Iraqi environmental conditions.

في منظومات التبريد ألهجينه العاملة بالطاقة الشمسية تستخدم مجمع شمسي لتحويل الطاقة الشمسية إلى مصدر حرارة لتحميص مائع التثليج الخارج من الضاغط وهذه العملية تساعد في تحول مائع التثليج من الحالة الغازية إلى الحالة السائلة في الثلثين الأعلى من المكثف بدلا من الثلثين السفلي من المكثف كما في منظومات التبريد التقليدية وهذا بدوره يقلل من الطاقة الضرورية لقياده عمليه التبريـــــــــــــد ،تم استخدام منظومة تبريد هجينه بسعة 1 طن ولمائع التبريد نوع R22 وكانت قيمه التيار المسحوب من قبل المنــــــــظومة بحــــــدود (3.9-4.2A) وهو نفس قيمه التيار المحسوب من قبل منظومة تقليدية ضمن هذه الأجواء للعراق، وبعد اخذ قراءات مختلفة لدرجات الحرارة والضغط لعده نقاط في المنظومة وجد إن مائع التثليج عندما يخرج من الضاغط فأنه يفقد جزء من حرارته إلى الماء الموجود في المجمع الشمسي عن طريق المبادل الحراري في حين إن الأدبيات المنشورة وفق الشركات المصنعة إن المجمع الشمسي وهو من النوع المفرغ الأنابيب يساهم برفع الضغط ودرجة الحرارة لمائع التثليج وذلك لتقليل استهلاك الطاقة المصروفة على الضاغط. لذلك فأن المنظومة على وصفها الحالي لاتتناسب للاستخدام المنزلي ضمن الظروف البيئية العراقية.

Listing 1 - 10 of 46 << page
of 5
>>
Sort by
Narrow your search

Resource type

article (46)


Language

English (36)

Arabic and English (6)

Arabic (2)


Year
From To Submit

2019 (2)

2018 (11)

2017 (7)

2016 (5)

2015 (3)

More...