research centers


Search results: Found 2

Listing 1 - 2 of 2
Sort by

Article
EXPERIMENTAL STUDY FOR GROUND TYPE EFFECT ON SOLAR CHIMNEY POWER PLANT

Authors: Mohammed H. Abbood --- Mohammed R. Abbas
Journal: KUFA JOURNAL OF ENGINEERING مجلة الكوفة الهندسية ISSN: 25230018 Year: 2018 Volume: 9 Issue: 2 Pages: 103-113
Publisher: University of Kufa جامعة الكوفة

Loading...
Loading...
Abstract

Solar chimney power plant is a technology capable to generate electric energy through a wind turbine using the solar radiation as energy source; nevertheless, one of the objectives pursued since its invention is to achieve energy generation during day and night. The ground under the power plant plays an important role on the energy balance and heat transfer, due to its natural behavior as a heat storage system. An experimental model was designed in Holley Kerbala city (Iraq), which consisted of a 3m collector radius with 8ᴼ collector inclination angle and a 6m height of chimney been constructed and collector periphery opening height 3cm. Three kinds of grounds was studied in this work: sand, mixed from sand and pebble and the third is black pebble. The results show that the highest airflow temperature inside the chimney reached was 66.8Co when using the black pebbles basement. The maximum basement temperature measured was 81.6Co for the mixed basement. Also, the highest temperature difference reached was 23.2Co for the same ground that have good performance during day light compared with pebble basement that have more energy saving in night.


Article
Analysis and Control of Buck-Boost Converter with the Same Input Polarity Based on Novel Energy Factor Evaluation

Author: Mahmoud Shaker Nasr
Journal: Journal of University of Babylon مجلة جامعة بابل ISSN: 19920652 23128135 Year: 2017 Volume: 25 Issue: 1 Pages: 45-59
Publisher: Babylon University جامعة بابل

Loading...
Loading...
Abstract

This paper presents firstly a buck-boost circuit with the advantage that its output voltage polarity is the same as the input polarity. The circuit operation is presented and analyzed in different modes of operation.The well known parameters used in evaluation of DC/DC converters like Total Harmonic Distortion THD, Power Factor PF, and Ripple Factor RF have no meaning in DC/DC converters, so it is to introduce efficient concepts to permit a fair evaluation of the converter. This paper present other parameters that can be used to study the characteristics of the converter and gives a real and logic means of its operation. These main parameters are: pumping energy PE, storage energy SE, energy factor EF, and energy losses EL. In addition, the converter efficiency is not considered as 100 % as taken in most analyzing studies.The positive DC/DC buck-boost converter is evaluated according to the new concepts and the system model is deduced for different cases of operation taking into account the resistance of the circuit inductor. The circuit is implemented practically and the presented obtained results show the correct operation under different modes of operation.In addition the control design of the converter is built such that a PI controller with windup is considered. In order to test the effectiveness of the designed control algorithm, the system were exposed to different voltage reference values and the obtained results demonstrate that the system responses for all cases are very acceptable according to the criteria of the control system theory.

تقدم هذه الورقة أولا دائرة مغير القدرة خافض/رافع (Buck/Boost) مع ميزة أن قطبية جهد الخرج التيار الكهربائي لها هو نفس قطبية الإدخال. كذلك سيتم تقديم عمل الدائرة اضافة الى تحليل كافة الحالات في مختلف انماط عملها. المتغيرات المعروفة والمستخدمة في تقييم مغيرات القدرة مثل عامل التموج (RF)، التشوه التوافقي الكلي (THD)، ومعامل القدرة (PF) في الحقيقة لا تمتلك المعنى الحقيقي لها والتي تفيد بشكل دقيق في تقييم مغيرات القدرة نوع جهد مستمر/مستمر، لذلك اضحى من الضروري ايجاد متغيرات ذات مفاهيم كفوءة في تقييم عادل و منطقي وعملي لمغيرات الطاقة من هذا النوع. يقدم هذا البحث معايير جديدة والتي يمكن استخدامها لدراسة خصائص مغيرات القدرة ( نوع مستمر/مستمر) وتعطي وسيلة حقيقية ومنطقية لعملها. المتغيرات الجديدة الرئيسية هي عامل الطاقة (EF)، ضخ الطاقة (PE)، تخزين الطاقة (SE)، خسائر الطاقة (EL). وبالإضافة إلى ذلك فإننا لم نفرض أن الكفاءة تساوي 100٪ كما هو الحال في معظم الدراسات وإنما يتم أخذ المفاقيد بنظر الاعتبار عند التحليل.في هذه الورقة، تم تقييم عمل مغير القدرة ( جهد مستمر/ مستمر ) ذات القطبية المتطابقة استنادا الى مفاهيم المتغيرات الجديدة و أن نموذج المنظومة تم تقييمه لحالات عمل مختلفة (تغيير زمن التوصيل للمفتاح) آخذين بنظر الاعتبار ان الملفات لها مقاومة وبالتالي هنالك فقد في القدرة. تم تنفيذ الدائرة عمليا وعرضت النتائج المستحصلة بحالات العمل المختلفة خلال عرض البحث حيث تؤكد عمله بشكل ممتاز. وبالإضافة إلى ذلك تم تصميم السيطرة على عمل المغير حيث استخدمنا وحدة تحكم نوع تناسبي/ تكاملي PI)) مع تقنية الانطلاق (windup) ومن أجل إختبار فعالية نظام السيطرة تم تعريض النظام إلى حالات متعددة من جهد العمل المطلوب (جهد المرجعية) (Reference Voltage) حيث أثبتت النتائج التي تم الحصول عليها فعالية وحدة تحكم لمتابعة جهد المرجعية.

Listing 1 - 2 of 2
Sort by
Narrow your search

Resource type

article (2)


Language

English (2)


Year
From To Submit

2018 (1)

2017 (1)