research centers


Search results: Found 21

Listing 1 - 10 of 21 << page
of 3
>>
Sort by

Article
Preparation and Analytical Study of New Chelating Resin Containing Tetracycline Drug
لتحضير والدراسة التحليلية مِنْ راتنجِ Chelating الجديد يَحتويانِ مخدّرَ Tetracycline

Author: Modhar N. Abdulla, Munther A. M-Ali and Rawnaq T. Kadhim
Journal: Journal of Basrah Researches (Sciences) مجلة ابحاث البصرة ( العلميات) ISSN: 18172695 Year: 2012 Volume: 38 Issue: 3A Pages: 78-88
Publisher: Basrah University جامعة البصرة

Loading...
Loading...
Abstract

A new chelating resin was prepared by mixing tetracycline drug and trimethylolphenol. It was polymerized by heating to 90 °C then it was post cured to 100 °C after that it was grinded. The chelating behavior was examined against Co(II), Ni(II) and Cr(III) using patch method in different conditions like treatment time and pH at room temperature. The resin shows a good loading capacity toward Co(II) (time = 24 hrs and pH = 4) = 12.24 mg ion/ g resin, Cr(III) (time = 24 and pH = 4) = 11.21 mg ion/ g resin, and Ni(II) (time = 4 hrs and pH = 2) = 9.3 mg ion/ g resin.

نوع جديد من الراتنج chelating هُيّأَ بخَلْط مخدّرِ tetracycline وtrimethylolphenol. هو بُلمرَ بتسخين إلى 90 °C ثمّ اجبرت إلى 100 °C بعد ذلك طحنت ودرس سلوك chelating فُحِصَ ضدّ شركاء Co(II), Ni(II) and Cr(II) إستعمال طريقةِ رقعةِ في الشروطِ المختلفةِ مثل وقتِ معالجةِ وpH في درجةِ حرارة الغرفةِ. يُشوّفُ a قدرة تحميل جيدةِ نحو شركاءِ (الثّانية) (وقت = 24 ساعات وpH = 4) = 12.24 آيون mg / g راتنج، Cr (الثّالث) (زمن = 24 وpH = 4) = 11.21 آيون mg / g راتنج، وNi (الثّاني) (زمن = 4 ساعات وpH = 2) = 9.3 آيون mg / g راتنج.


Article
ASSAY OF TETRACYCLINE IN PHARMACEUTICAL PREPARATIONS, SPIKED INDUSTRIAL WASTEWATER AND CHICKEN MEAT SAMPLES USING VISIBLE SPECROPHOTOMETER TECHNIQUE
تقدیر التتراسایكلین طیفیا في المستحضرات الصیدلانیة ولحم الدجاح والمیاه الصناعیة المطروحة

Loading...
Loading...
Abstract

A simple, accurate, and rapid visible spectrophotometric method has beendeveloped for the determination of tetracycline hydrochloride in pure, pharmaceuticalpreparations and environmental water samples. The method is based on the oxidationof tetracycline hydrochloride by sodium hypochlorite in alkaline medium to form ared colored product with an absorption maximum at 400 nm. Beer’s Law was obeyedin the range of 2-24 µg/ml with molar absorptivity of 1.346×104 L.mol.-1.cm-1. Therelative standard deviation of the method was less than 2% and accuracy (averagerecovery ) was 100 ± 0.85 % .The optimum conditions for all color development aredescribed and the proposed method has been successfully applied for thedetermination of tetracycline hydrochloride in pharmaceutical preparations, chickenmeat and waste water samples.

تم اختبار طریقة طیفیة جدیدة مباشرة لتقدیر التتراسایكلین في حالتھ النقیة وفي بعض مستحضراتھ الدوائیة وفيلحم الدجاج وفي المیاه الصناعیة المطروحة،تتمیز الطریقة بالبساطة والانتقائیة والحساسیة والدقة وتعتمد الطریقةعلى أكسدة التتراسایكلین بواسطة الھایبوكلورات في الوسط القاعدي لتعطي ناتج احمر اللون لھ أقصى امتصاصعند الطول ألموجي 400نانومیتر وأمكن تقدیر الكمیات التي تتراوح بین 24-2مایكروغراممل وان معاملالامتصاص المولاري للطریقة المقترحة ھو 1.346×104لتر .مول-.1سم-.1ان الانحراف القیاسي النسبيللطریقة أقل من % 2وبدقة )معدل استرجاعیة( . % 0.85 ±100وتم دراسة الظروف المثلى للتفاعل .وطبقتالطریقة بنجاح لتقدیرھیدروكلورید التتراسایكلین في حالتھ النقیة وفي مستحضراتھ الصیدلانیة وفي لحم الدجاجوفي المیاه الصناعیة المطروحة


Article
Loss of Tetracycline Resistant Gene from pBR322 by Direct Repeat Spontaneous Homologous Recombination

Author: Evan L. Khaleef ايفان لطيف خليف
Journal: Al- Anbar Medical Journal مجلة الأنبار الطبية ISSN: PISSN: 27066207 / EISSN: 26643154 Year: 2012 Volume: 10 Issue: 2 Pages: 11-18
Publisher: University of Anbar جامعة الانبار

Loading...
Loading...
Abstract

Objectives: It's well known that tetracycline resistant gene in pBR322 is about 1190bp clockwise in direction and tetracycline antibiotic inhibits bacterial protein synthesis. Resistant cells are able to grow in the presence of tetracycline because of efflux system. In this study, we try to delete tetracycline resistant gene from pBR322 by spontaneous homologous recombination between direct homology flanked regions. Subject and Methods: There is direct repetitions Direct repeat between flank regions of tetrgene of pBR322 yield loss of tetrgene (Tetracycline Resistant Gene) by spontaneous homologous recombination. Restriction enzyme and T4 DNA ligation from NEB Phusion High Fidelity PCR Kit from NEB was used for PCR amplification. The measurement of rate of loss of tetrgene from pBR322 by homologous recombination was made using fluctuation test.Results: After construction of new derivative from pBR322 which includes200bp flank region upper to tetrgene homology with downstream region in same direction, the measurement of rate of loss of tetrgene by fluctuation test was 64%.Conclusion: The high rate of loss of tetrgene from pBR322 by direct repeat spontaneous homologous recombination indicated that homologous recombination between 200bp flank region for gene like tetrwhich it is about 1190bp consider as active method to delete the wanted gene.


Article
Application of Factorial Design for Optimization of Flow-Injection Spectrophotometric Determination of Tetracycline in Some Pharmaceutical Formulations
تطبيق تصميم المضروب لإيجاد الظروف المثلى للحقن الجرياني المطيافية الضوئية لتقدير التتراسايكلين في بعض التركيبات الدوائية

Author: Chinar Mohammed Risheed جنار محمد رشيد
Journal: Tikrit Journal of Pure Science مجلة تكريت للعلوم الصرفة ISSN: 18131662 Year: 2013 Volume: 18 Issue: 3 Pages: 56-62
Publisher: Tikrit University جامعة تكريت

Loading...
Loading...
Abstract

A simple and rapid flow injection (FI) spectrophotometric procedure for the determination of tetracycline (TC) has been developed. The method is based on the injection of 150 μl standard or sample solution into a distilled water carrier stream which merged at the merging zone with ferric nitrate solution with the optimum flow rate of 1.5 mL/min, subsequently the reaction will occur inside the reactor coil, forming brown color product that monitored at 418 nm. The flow injection experimental conditions were optimized by means of full factorial design. Under the optimum conditions, calibration graph was obtained over the range 2.0-120 μg/ml with a detection limit of 1.0 μg/ml. The correlation coefficient and molar absorptivity were 0.9994 and 4.343x103 L/mol.cm respectively. The results showed a good precision and accuracy. The method was successfully applied to the determination of tetracycline in pharmaceutical formulations and showed good agreement with those obtained by the standard method at 95% confidence level, with a sample throughput of 60/h.


Article
Sensitive Spectrophotometric Determination of Tetracycline Hydrochloride Indosage forms using Sodium Nitroprusside and Hydroxylamine Hydrochloride

Authors: Hind Hadi --- Ghadah Fadhil
Journal: Al-Nahrain Journal of Science مجلة النهرين للعلوم ISSN: (print)26635453,(online)26635461 Year: 2014 Volume: 17 Issue: 3 Pages: 53-58
Publisher: Al-Nahrain University جامعة النهرين

Loading...
Loading...
Abstract

An optimized and validated spectrophotometric method has been developed for the determination of Tetracycline hydrochloride (TCH) in pharmaceutical formulations. The method is based on the reaction between TCH, sodium nitroprusside and hydroxylamine hydrochloride in alkaline medium. The product absorbed maximally at 529 nm. Beer’s law is obeyed in the working concentration range of 2-60 µg mL-1 with apparent molar absorptivity of 5.049×103 L mol-1cm-1 and Sandell’s sensitivity of 0.0952 µg cm2/ 0.001 absorbance unit. The proposed procedure was applied successfully for estimation of drug in different commercial forms. The proposed method was applied to the determination of the studied drug in pharmaceutical formulations and the results demonstrated that the method is equally accurate and precise as the official method as found from the t- and F-values.

يتضمن البحث تطوير طريقة طيفية سريعة وحساسة للتقدير الكمي للمقادير الضئيلة من مستحضر التتراسايكلين هيدروكلورايد في المحاليل المائية والمستحضرات الصيدلانية باستخدام الطريقة الطيفية. تعتمد الطريقة على التفاعل بين التتراسايكلين وكاشف نتروبروسيد الصوديوم وهيدروكسيل امين هيدروكلورايد في الوسط القاعدي. بلغ مدى الخطية 2-60 مايكروغراممل من التتراسايكلين حيث تم القياس عند طول موجي 529 نانومترا. قيمة الامتصاصية المولارية وحساسية ساندل مساوية الى 5.049 ×103 لتر.مول-1.سم-1 و 0.0952 مايكروغرام .سم-2 على التوالي .طبقت الطريقة المقترحة بنجاح لتقدير الدواء في مستحضراته الصيدلانية حيث اثبتت النتائج من خلال اختباري t وF بعدم وجود اختلاف بالدقة والتوافقية بين الطريقة المقترحة والطريقة القياسية.


Article
Spectrophotometric Determination of Tetracycline by Coupling with Diazotised 4-Aminoantipyrine in Presence of Cetylpyridinium Chloride
التقدير الطيفي للتترأسايكلين بالاقتران مع العامل المؤزوت 4-امينو انتي بايرين بوجود سيتيل بريدنيوم كلوريد

Authors: Rasha J. Al-Ashow رشا جياد العشو --- Nabeel S. Othman نبيل صبيح عثمان
Journal: Rafidain journal of science مجلة علوم الرافدين ISSN: 16089391 Year: 2012 Volume: 23 Issue: 2E Pages: 72-84
Publisher: Mosul University جامعة الموصل

Loading...
Loading...
Abstract

A spectrophotometric method for the determination of microgram amounts of tetracycline -HCl(TCH) has been proposed. The method is based on coupling of tetracycline-HCl with diazotized 4-aminoantipyrine in presence of cetylpyridinium chloride in alkaline medium. The molar absorptivity of the formed dye reached to 1.92×104 l.mol-1. cm-1 at 537 nm and Beer's law is obeyed within the range of 10-300 μg of tetracycline-HCl /10 ml (i.e.1.0 – 30 ppm). The colour reaction was highly stable, a relative error ranged from - 2.5 to + 0.21 % and a relative standard deviation of ± 0.37 to ± 0.73 %, depending on concentration level of tetracycline-HCl. The proposed method has been applied successfully to the determination of tetracycline-HCl in pharmaceutical preparations.

تم اقتراح طريقة طيفيه لتقدير كميات متناهية في الصغر من هيدروكلوريد التتراسايكلين. تعتمد الطريقة على اقتران التتراساكلين مع العامل المؤزوت 4- امينوانتي بايرين بوجود سيتيل بريدنيوم كلوريد في الوسط القاعدي. بلغت قيمة معامل الامتصاص المولاري للصبغة المتكونة1.92 ×10 4 لتر.مول-1.سم-1 عند الطول الموجي الاعظم 537 نانوميتر. وتتبع الطريقه قانون بير في مدى التراكيز من 10 الى 300 مايكروغرام/ 10 مل (أي من1-30 جزء/مليون). يمتاز التفاعل اللوني باستقرارية جيدة وبخطأ نسبي يتراوح بين 2.5 - و 0.21 %وانحراف قياسي نسبي بين 0.37± و % 0.73± اعتمادا على مستوى التركيز. تم تطبيق الطريقة بنجاح في تقدير هيدروكلوريد التتراسايكلين في المستحضرات الصيدلانية.


Article
SPECTROPHOTOMETRIC DETERMINATIONOF TETRACYCLINE IN SOME PHARMACEUTICALPREPARATIONS
التقدير الطيفي للتتراسايكلين في بعض المستحضرات الصيدلانية

Loading...
Loading...
Abstract

This paper briefly describes a simple spectrophotometric method for the determination of tetracycline in pharmaceutical preparation . The method is based on measurement of the absorbance of tetracycline- cerium(IV)complex at 430 nm in 1M sulphuric acid solution. Calibration graph for tetracycline was obtained over the range of 50-350 µg.ml- 1 The detection limit (2x noise) is 0.0025 µg.ml- 1 and with R.S.D for 5 replicate 0.03% .This method allowed the determination of tetracycline in pharmaceutical preparations with a satisfactory accuracy when comparing it with official BP method.

يصف البحث باختصار طريقة طيفية بسيطة لتقدير التتراسايكلين في بعض المستحضرات الصيدلانية.الطريقة تعتمد على امتصاصية معقد التتراسايكلين-السير يوم الرباعي عند 430 نانومتر في محلول1 مولارى من حامض الكبريتيك وتم الحصول على منحنى المعايرة للتتراسايكلين بحدود50-350 مايكروغرام/مل مع حد كشف (2xالضوضاء) 0.0025 مايكروغرام/مل ومعدل الانحراف القياسي النسبي لخمس قرأءات 0.03%. هذه الطريقة تسمح بتقدير التتراسايكلين في المستحضرات الصيدلانية وبدقة الطريقة العالميةالبريطانية


Article
Batch and Flow Injection Spectrophotometric Determination of Tetracycline Hydrochloride and Doxycycline Hyclate in Pharmaceutical Preparations
التقدير الطيفي للتتراسايكلين هيدروكلورايد والدوكسي سايكلين هايكلات في المستحضرات الصيدلانية بطريقة الدفعة والحقن الجرياني

Authors: Mouayed Q. Al-Abachi مؤيد قاسم العبايجي --- Zaid A. Al-Nedawi زيد عبد الستار النداوي
Journal: Iraqi Journal of Science المجلة العراقية للعلوم ISSN: 00672904/23121637 Year: 2015 Volume: 56 Issue: 2A Pages: 909-920
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

New, simple and accurate batch and flow injection spectrophotometric methods have been developed for the determinationsof tetracycline hydrochloride (TCH) and doxycycline hyclate (DCH) in pharmaceutical preparations.The methods are based on diazotization of metchlopramide and coupling reaction with either TCH or DCH in alkaline medium to form yellow–orange water soluble dye with absorption maxima at 414 and 436 nm for TCH and DCH, respectively. A graphs of absorbance versus concentration show that Beer’s law was obeyed over the concentration ranges of 1 –52 µgmL-1 TCH and DCH for batch method and of 8 – 240 µg mL-1 TCH and 5 – 350 µgmL-1 DCH for FIA method. The limits of detection in batchmethods were 0.333 and 0.235µgmL-1for TCH and DCH respectively, and in FIA methods were 0.895, 0.612 µgmL-1for TCH and DCH respectively. Samplethroughputs in FIA procedures were 120 and 80samples per hour for TCH and DCH, respectively. Different chemical and physical experimental parameters affecting on the development and stability of the colored product were carefully studied and the proposed methods were successfully applied for determination of TCH and DCH in pharmaceutical preparations.

يتضمن البحث تطوير طرائق بسيطة وجديدة وذلك باستخدام تقنية المطياف الضوئي بطريقة الدفعة والحقن الجرياني للتقدير الكمي لكل من التتراسايكلين هيدروكلورايد و الدوكسي سايكلين هايكلات في المستحضرات الصيدلانية .اعتمدت الطرائق على تفاعل الازودتة والازدواج بين الميتكلوربرمايد المؤزوت والتتراسايكلين والدوكسي سايكلين حيث تتكون نواتج من اصباغ الاوزو الملونة وذائبة بالماء اعطتا على قمة امتصاص عند طول موجي414 و436نانوميتر لكل من التتراسايكلين والدوكسي سايكلين على التوالي . تشير منحنيات الامتصاص مقابل التركيز بانقانونبيرينطبقضمنمدىالتركيز52-1و50-1 مايكروغرام لكل مل لكل من التتراسايكلين هيدروكلورايد والدكوكسي سايكلين على التوالي وبحدودكشف 0.333 و 0.235 مايكروغرام لكل مل للتتراسايكلين هيدروكلورايد والدوكسي سايكلين هيكلات على التوالي لطريقةالدفعة.امابطريقةالحقن- الجريانيفكانمدى التراكيز من 280-5 و350-5 مايكرو غرام لكل مل للتتراسايكلين هيدروكلورايد والدوكسي سايكلين هيكلات على التوالي، وحدود الكشفكانت0.895 و0.612 مايكروغرام لكل مل للتتراسايكلين والدوكسي سايكلين على التوالي، تمت دراسة الظروفالمثلى للمتغيراتالكيميائيةوالفيزيائيةبدقةوطبقتالطريقتينبنجاحعلى المستحضرات الصيدلانية الحاويةعلى التتراسايكلينهيدروكلورايد والدوكسي سايكلين هيكلات.وقورنتالنتائجالتيتمالحصولعليها معنتائجطرائقالتحليل القياسبةللادويةاعلاهواظهرتنتائجالمقارنةعدموجودفرق جوهري بين نتائج الطرائق المقترحة ونتائج الطريقة القياسية .


Article
Determination and quality evaluation of some imported drugs in Iraqi kurdistan region
تقدیر و تخمین نوعیة بعض الأدویة المستوردة في کردستان – العراق

Author: Yousif J. Azeez یوسف جلال عزیز
Journal: Tikrit Journal of Pure Science مجلة تكريت للعلوم الصرفة ISSN: 18131662 Year: 2016 Volume: 21 Issue: 3 Pages: 81-85
Publisher: Tikrit University جامعة تكريت

Loading...
Loading...
Abstract

Some of important drugs in Kurdistan Region are planned to be determined such as analgesics and antibiotics from different available companies. For the first stages Paracetamol, Aspirin, Chloramphenicol, Ibuprofen and Tetracycline drugs were examined and the real quantities determined were compared with that reported on a commercial labels. Mean recoveries 99.2,95.9,99.2,99 and 102.8 respectively, and have percentage errors (%E) -0.80, -4.07,-0.80, 2.80 and -1.00 respectively and the best companies for these drugs.

تم تقدير بعض ادوية مهمة في منطقة كردستان و بطريقة قياسية وكمياتهم ومقارنتهم مع المكتوب على غلاف الورقة والأدوية المهمة عبارة عن: باراسيتامول، أسبرين، الكلورمفينكول، ابوالپرفين، و تيتراسايكلين و استرجاعية ,99.2 99,99.2,95.9 و 102.8 علی التوالي ونسبة الخطأ(E%) -0.80,-4.07,- 0.802.80 ,و-1.00 على التوالي وأفضل شركة لأنتاج هذه الأدوية.


Article
Chromatographic estimation of tetracycline in saliva

Loading...
Loading...
Abstract

Tetracyclines have been widely used in dentistry, especially in treatment of periodontal diseases and other oral pathological lesions. They are effective in treatment because their concentration in the gingival crevice is 2-10 times that in serum. In addition, several studies have demonstrated that tetracyclines at a low gingival crevicular fluid concentration (2-4 mg/ml) are very effective against many periodontal pathogens. Tetracyclines are an extensively used group of antibiotic medicines. Clinical pharmacology of tetracycline in saliva was not clear until the time of this research achieving on normal subjects or patients required tetracycline treatment. The evaluation was achieved by using suitable method (efficient, low cost, and reproducible). The purpose of this study is the determination of the tetracycline concentration in saliva. The obtained results from HPLC method recorded saliva concentration of tetracycline ranged fom 0.08 to 0.23 μg. / ml. The HPLC method provided successful methods for monitoring the tetracycline in saliva with a detection limit reached to 0.05 ng/ml. Since the saliva is considered as the first line of immune system in the oral cavity, so it is important to suggest further study to know the therapeutic effect of tetracycline through saliva against certain oral lesions.

Listing 1 - 10 of 21 << page
of 3
>>
Sort by
Narrow your search

Resource type

article (21)


Language

English (18)

Arabic (2)

Arabic and English (1)


Year
From To Submit

2018 (4)

2017 (3)

2016 (3)

2015 (2)

2014 (3)

More...