research centers


Search results: Found 25

Listing 1 - 10 of 25 << page
of 3
>>
Sort by

Article
Hardness Removal from Drinking Water

Authors: Ahmed A. M. Ali --- Nawar O. A. Nasser
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2006 Volume: 12 Issue: 2 Pages: 405-413
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

This study included three trials that were made during December 2003 by using lime, of 98% w/w calcium hydroxide to find the relation between lime doses to be added and the hardness removed .The trials were performed by adding various doses of lime and measuring the hardness, electrical conductivity and pH in water produce by three plants, Nissan in the north of Baghdad, Al-Karama and Al-Wathba water treatment plant in Baghdad center. The objective of this study is to find the optimum lime dose that gives the minimum hardness content.The results indicate a non linear relation between lime dose added and the hardness removed . The results represented a 36% removal in hardness when using an optimum dose of lime 200 ppm in Nissan water treatment plant, while a percentage removal of 34% was obtained in both Al-Karama and Wathba water treatment plants with 300 ppm dose of lime.The low percentage removal indicates the presence of non-carbonate hardness which could not be removed by lime alone.

تضمنت هذه الدر اسه ثلاث محاولات أجريت خلال كانون الأول 2003باستخدام هيدروكسيد الكالسيوم 98% نسبه وزنيه لإيجاد العلاقة بين جرعة هيدروكسيد الكالسيوم وإزالة العسرة ,المحاولات تمت بإضافة جرع مختلفة من هيدروكسيد الكالسيوم وقياس العسرة والتوصيل الكهربائي وقوة أيون الهيدروجين للماء المسحوب من ثلاث محطات لتصفية ماء الشرب وهي مشروع نيسان شمال مدينة بغداد ,مشروع الكرامة ومشروع الوثبة مركز مدينة بغداد ,الهدف من هذه الدر اسه هو إيجاد الجرعة القصوى من هيدروكسيد الكالسيوم التي تعطي اقل تركيز للعسره. النتائج أظهرت أن هناك علاقة لا خطيه بين جرع هيدروكسيد الكالسيوم المضافة والعسره المزالة ,النتائج تمثلت بإزالة 36% من العسره عند إضافة أقصى جرعه من هيدروكسيد الكالسيوم 200 ملغملتر في مشروع نيسان بينما نسبة أزاله 34% تم الحصول عليها في مشروعي الكرامة والوثبة لجرع 300 ملغملتر النسبة القليلة للازاله أشارت إلى وجود عسره لا كاربونيه والتي لا يمكن أزالتها باستخدام هيدروكسيد الكالسيوم لوحده


Article
INFLUENCE OF WATER AND SEWAGE TREATMENT PROCESSES ON DECREASING DIARRHEAL DISEASES IN MARSH COMMUNITY OF IRAQ

Author: Hussein Al-Nasrawi
Journal: AL-TAQANI مجلة التقني ISSN: 1818653X Year: 2009 Volume: 22 Issue: 2 Pages: 1-8
Publisher: Foundation of technical education هيئة التعليم التقني

Loading...
Loading...
Abstract

Water contaminated by sewage or human excrement presents the greatest danger to public health associated with drinking water,and pathogens present in water are usually greatly outnumbered by normal intestinal bacteria, which are easier to isolate and identify. The coliform group merits consideration as an indicator of water pollution because these bacteria are always present in the intestinal tracts of humans and other warm-blooded animals and are excreted in large numbers in faecal wastes , so in case of discharging sewage disposals under untreated conditions , coliform group appears as a focus of water contamination . The present study aimed to confirm the influence of rehabilitation water and sanitation facilities on decreasing diarrheal cases among marsh community . Multiple tubes fermentation method was used in present paper, included Measurement of Most Probable Number of E.coli which incubated under 44 C˚. Results of our present study revealed that diarrheal cases among marsh community children have been decreased from 139 to 49 case after construction new water facility and decrease of E.coli from >10 to < 10 colonies per 100ml due to treatment process of waste water . Conclusions of present study confirmed that untreated sewage influents consider the main key factor for possibility of spreading E.Coli in untreated drinking water which contribute in increasing of morbidity cases among children under years of age

يعد تلوث الماء بمياه المجاري أو براز الإنسان من أكثر المخاطر التي تواجه صحة المجتمع فيما يخص مياه الشرب , وان مصدر الممرضات الملوثة للماء عادة ما يكون منشأها بكتريا القولون التي من السهولة عزلها والتعرف عليها . إن وجود بكتريا القولون في الماء هو دليل على التلوث لكون هذه البكتريا تعيش في أمعاء الإنسان وفي بقية الكائنات ذوات الدم الحار وتفرغ بإعداد كبيرة في مياه المجاري و لذلك ففي حالة تصريف مياه المجاري إلى النهر دون معاملة فان هذه الأحياء سوف تتركز في المياه وتعد مصدرا لتلوثها .استهدفت الدراسة الحالية التأكيد على تأثير إعادة تأهيل محطات تصفية المياه ووحدة معاملة مياه المجاري على انخفاض حالات الإسهال في مجتمع الأهوار .استخدمت في الدراسة الحالية طريقة التخمر للأنابيب المتعددة والتي تضمنت العد الأكثر احتمالا لبكتريا القولون التي حضنت تحت درجة 44م ˚المشجعة على نمو بكتريا القولون .أظهرت نتائج الدراسة الحالية انخفاضا في عدد حالات الإصابة بالإسهال من 139 حالة إلى 49 حالة بعد إنشاء محطة تصفية المياه في المنطقة المستهدفة في الدراسة , بينما انخفضت حالات الإسهال من 688حالة إلى 250 حالة تسبب تنقية مياه المجاري .استنتجت الدراسة الحالية إن المصدر الرئيسي للتلوث في المياه هي مياه المجاري التي تفرغ في النهر دون معالجة مما يؤدي إلى انتشار بكتريا القولون قي الماء والتي تساهم في ارتفاع حالات الإصابة بالإسهال خصوصا لدى الأطفال دون الخامسة من العمر


Article
Evaluation of a Number of Water Treatment Plants in Kirkuk Governorate using the Water Quality Index

Authors: AbdulRazaq Khader Abdul Wahid --- Idan I. Ghdhban --- Rodhan Abdullah Salih
Journal: Tikrit Journal of Engineering Sciences مجلة تكريت للعلوم الهندسية ISSN: 1813162X 23127589 Year: 2018 Volume: 25 Issue: 1 Pages: 49-59
Publisher: Tikrit University جامعة تكريت

Loading...
Loading...
Abstract

A study was conducted on sixteen water purification plants in Kirkuk governorate to evaluate the treatment of water in them, where physical and chemical tests were conducted for raw water and treated water for a period of (6) months from December until May. Temperature, turbidity, pH, Total Dissolved Solid (TDS), Electric Conductivity (EC), alkali, Total Hardness (TH) and calcium (Ca+2) were measured. Water quality index Canadian method (CCME) was used to classify raw water quality and treated water. The results showed that the raw water for all stations was classified as category (4) (bad) during the study period. The treated water was different for the treatment plants. Two of the treatment plants recorded good efficiency in water treatment (AL-Shallalah plant and Sin AL-Thiban) the treated water remained in category (2) (good). While the water quality of AL-Mosanaa plant indicated that there was a problem in the treatment of water in this plant, the treated water remained in category (4) bad during the study period. Water quality index fluctuated for other plants during the study period. The study also showed that alkali values of all stations were higher than the allowable limit for raw water and treated water.


Article
Evaluating the Performance of Sharq Dijila Water Treatment Plant
تقيم اداء محطة ماء شرق دجلة

Authors: Wassel Kadum واصل كاظم --- Faris Hammoodi Al-Ani فارس حمودي محمد
Journal: Al-Khwarizmi Engineering Journal مجلة الخوارزمي الهندسية ISSN: 18181171 23120789 Year: 2011 Volume: 7 Issue: 2 Pages: 55-67
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

The study aims mainly to evaluate the performance of Sharq Dijila water treatment plant in removing turbidity for the period of 1-4-2001 to 31-3-2004. Daily data for turbidity of raw, clarified, filtered, and supplied water were analyzed. The results of the study showed that there is a wide variation in turbidity levels of raw water fluctuating between 10-1000 NTU with mean value of 41.3 NTU. Turbidity values of the clarified water varied between 1.4-77 NTU. Based on the turbidity value of 10 NTU and 20 NTU (the design maximum turbidity) the readings gave an acceptable percentage of 32.4% and 86% respectively. The turbidity of filtered water ranged between 0.2-4.5 NTU which are completely in compliance with Iraqi and WHO standards. In accordance with the American Environmental Protection Agency (USEPA) and based on the analysis of 2-day moving average of 5 NTU and 30-day moving average of 1 NTU, it was found that the filters operated at acceptable percentage of 100% and 45% respectively. Turbidity value of the supplied water averaged between 0.4-9.5 NTU which is higher than the turbidity of the filtered water due to the mixing of the water from all other filters. Also turbidity values from the unwashed filters are higher than the washed filters and the precipitation in the treated water reservoir. Based on the Iraqi Drinking Water Standard, USEPA 2-day and 30-day moving average, the supplied water was within the permissible limits of 98%, 98.6%, and 98.6% respectively.

إن الهدف من هذه الدراسة هو تقيم اداء محطة تصفية ماء شرق دجلة في ازالة العكورة للفترة من 1-4-2001 ولغاية 31-4-2004 تم تحليل قياسات العكورة للمياه الخام، المياه المرسبة، المياه المرشحة، والمياه المجهزة. بينت نتائج الدراسة ان هناك اختلاف كبير في درجة العكورة للماء الخام تراوحت بين 1-1000 وبمعدل41,3 وحدة قياس العكورة . قيم العكورة للمياه المرسبة كانت 1.4-77 وحدة و بالاعتماد على قيمة عكورة 10 و20 (التصميمية) نرى ان القراءات اعطت نسبة قبول مقدارها 32.4% و86% على التوالي. اما العكورة للمياه المرشحة فتراوحت بين 0.2-4.5 وحدة والتي تتوافق كليا مع مواصفة القياسبة العراقية ومواصفة منظمة الصحة العالمية. وبالمقارنة مع مواصفة منظمة حماية البيئة الامريكية وبالاعتماد على تحليل 2- يوم معدل متغير (5 وحدة ) و30- يوم معدل متغير (1وحدة ) وجد ان الفلاتر تعمل بنسبة قبول قدرها 100%و45% على التوالي.واما المياه المجهزة تراوحت العكورة بين 0.4-9.5 وحدة وهي اعلى من عكورة المياه الراشحة وهذا نتيجة للخلط الحاصل بين مياه جميع المرشحات كون العكورة للمرشحات الغير مغسولة اكبر من المرشحات المغسولة اضافة للترسبات الطينية داخل الخزان الارضي للمياه المجهزة. وبالاعتماد على المواصفات القياسبة العراقية، 2- يوم معدل متحرك، و30- يوم معدل متحرك فأن المياه المجهزة كانت 98%، 98.6%، 98.6% ضمن الحدود المسموح بها على التوالي


Article
IRAQI WATER TREATMENT PLANTS PROCESS CONTROL BY MEASURING EFFLUENT TURBIDITY
السيطرة على وحدات معالجة مياة الشرب في العراق بقياس كمية العكورة الناتجة

Authors: Jwad Khadhum. Ghaziy م.م. جواد كاظم غازي --- Ali H. GHAWI1 د.علي هادي غاوي
Journal: Al-Qadisiyah Journal for Engineering Sciences مجلة القادسية للعلوم الهندسية ISSN: 19984456 Year: 2010 Volume: 3 Issue: 4 Pages: 373-381
Publisher: Al-Qadisiyah University جامعة القادسية

Loading...
Loading...
Abstract

The Al-Dewanyia Water General Authority (DWGA) operates and maintains four water treatment plants to produce potable water for 300,000 inhabitations in Al-Dewanyia city. Surface water from Al-Dewanyia river is treated by aluminum sulphate (alum) coagulation, flocculation, sedimentation, filtration, and chlorine disinfection (clearwell). DWGA has set goals for turbidity for clarified and filtered water. These goals pertain to water inside the Water Treatment Plant (WTP), outside the water treatment plant, and in the distribution system, DWGA continues to meet the Iraqi Ministry of Health Standard of 5 NTU. Each day at DWGA WTPs, chemists measure the turbidity of water from each individual clarifier and from each individual filter. The WTP Manager reviews this data and uses it to make process control decisions about chemical dosage and filter backwash. This paper explains DWGA’s Turbidity Goal for filtered water, presents recent data, and describes how WTP managers use this data for process control. Any water treatment plant in Iraq can use these procedures. The results can be better process control and higher quality water

مديرية ماء الديوانية تشغل و تصين اربعة محطات لمعالجة مياه الشرب في مدينة الديوانية و التي تخدم 300,000 ألف نسمة. ان مصدر المياه المعالج هو نهر الديوانية و تستخدم وسائل التلبيد (إضافة الشب) و التخثير و الترسيب و الترشيح و التعقيم في تصفية المياه. مديرية ماء الديوانية و ضعت أهداف لإزالة العكورة من حوضي الترسيب و الترشيح. هذة الأهداف تتمثل بالحصول على ماء صالح للشرب و مطابق للمواصفات العراقية و البالغة NTU 5 . تم قياس تركيز العكورة يوميا من أحواض الترسيب و أحواض الترشيح. المهندسين المسئولين عن تشغيل المشروع قاموا بتحليل تلك القياسات لاتخاذ قرار حول مقدار الشب المضاف و عملية غسل الفلاتر. من خلال هذا البحث تم توضيح وسيلة فعالة من خلال القياسات اليومية لتركيز العكورة للحصول على ماء مطابق للمواصفات العراقية.ان هذة التقنية يمكن استخدامها في أي محطة معالجة لمياه الشرب في العراق.


Article
Evaluation of the Performance of the Dora Refinery Wastewater Treatment Plant

Authors: Muwafaq A. Abed --- Rafa H. Al-Suhaili
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2008 Volume: 14 Issue: 4 Pages: 3020-3035
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

Oil refineries are major contributors to local environmental problems .The main pollutants are oil , dissolved components , spent acids , suspended solids, sludge . Technically it is possible to remove all these pollutants by Physical , chemical and biological means .Oil is initially removed in the (API) separators , by skimming, while the heavy particles by scrapping . Further removal of discrete particles is done by gravity settlement in the primary settlement tank .The remaining suspended matter is removed by chemicals , that are added in the flocculation tank , while further flocs are removed in the air flotation tank . The biological treatment follows to remove the biological pollutants , usually followed by secondary settlement to reduce the flux of suspended particles carried with the effluent water. This thesis deals with the Dora refinery wastewater treatment plant , its present performance in comparison with the designed treatment performance and its final effluents compared with the Iraqi discharged water quality limitations .In order to identify the characteristics of the refinery effluents and to evaluate the performance of the refinery wastewater treatment plant , wastewater from different treatment stages were analyzed for various physical and chemical parameters . Using these parameters as the criteria of performance , comparisons were made between the actual and the designed performance for various potential pollutants. The sampling was conducted during 6 months from May to October 2006 , with two samples in each month for each of the units, one before , and one after.The results showed that the wastewater treatment plant in Al-Dora Refinery performed significantly, where high removal efficiencies , were obtained. For T.S.S , Oil , COD , BOD , Sulfide and Phenol which were 95% , 88% , 86% , 81% , 85% and 97% respectively . And the plant was not very efficient in NH3 , SO4 and PO4 removal .

ان المصافي تعتبر عالميا مساهم رئيسي في مشاكل البيئة الموقعية . اهم الملوثات الناتجة من المصافي والتي تنصرف مع المياه هي النفط ومركباته ,المواد المذابة والعالقة , الحوامض , الحمأة وغيرها . فنيا بالامكان ازالتها جميعا باساليب فيزياوية , كيمياوية وبايلوجية .حيث يتم ازالة النفط اولا في محطة المعالجة في خزانات خاصة للعزل وذلك بترك المياه فيها وقشط النفط الطافي على السطح وكذلك قشط المواد المترسبة في القعر . وتكون عملية الفصل في هذه الخزانات بفعل الجاذبية الارضية . تلي هذه المرحلة عملية فصل للمواد العالقة وذلك بخلط مواد كيمياوية مخثرة مع المياه في خزانات التخثير والدمج ومن ثم يتم تطويف المواد العالقة والمتكتلة في خزانات التطويف حيث يتم قشطها من السطح ومن قعر الخزان باستخدام القاشطات الخاصة لذلك . تتبع هذه العمليات عملية المعالجة البايلوجية , والتي يتم فيها معالجة المواد الذائبة بفعل الاحياء المجهرية (البكتريا ) ومن ثم يتم فصل هذه الملوثات وترسيبها في احواض الترسيب النهائي لفصل ما تبقى من المواد العالقة والمتجمعة والاحياء الحية المجهرية لتقليل جريانها مع المواد المنصرفة الى النهر. المعالجة البايلوجية في مصفى الدورة تستخدم التهوية الممتدة ووحدات الحمأة المنشطة . يتوفر في وحدات المشروع الاجهزة اللازمة للقشط والخلط والتهوية , وأحياء مجهرية حية تتغذى على الملوثات المجهرية . تستخدم هذه الدراسة أسلوب البحث والتحليل الاحصائي للبيانات المستحصلة من قراءات التحاليل الكيميائية للنماذج المأخوذة من مختلف المواقع في محطة المعالجة . وطريقة اخذ النماذج المتبعة كانت نموذج قبل وبعد كل وحدة من وحدات محطة المعالجة ولمدة ستة اشهر وللفترة من ايار وحتى تشرين الاول من عام 2006 وبواقع فحصين كل شهر وللملوثات:- (pH ,Oil , T.S.S , BOD5 ,COD ,N-NH3 ,Sulfide ,Sulfate , Phosphorous and Phenol ) النتائج اظهرت الاداء الكفوء لمحطة المعالجة في ازالة الملوثات (T.S.S ,OIL ,BOD , COD ,Sulfide , Phenol ) حيث سجلت اعلى نسبة ازالة لهذه الملوثات وهي 95% , 88% , 86% , 81% , 85% و97% على التوالي وكذلك النتائج اظهرت ان محطة المعالجة ليست كفوءة جدا في ازالة الملوثات NH3 , SO4 and PO4 .


Article
PERFORMANCE EVALUATION OF AL-DEWANYIA WATER TREATMENT PLANT IN IRAQ
تقيم أداء محطة معالجة مياه الشرب في مدينة الديوانية

Author: د . علي هادي غاوي,د. عباس عليوي الجبوري
Journal: Al-Qadisiyah Journal for Engineering Sciences مجلة القادسية للعلوم الهندسية ISSN: 19984456 Year: 2009 Volume: 2 Issue: 4 Pages: 664-677
Publisher: Al-Qadisiyah University جامعة القادسية

Loading...
Loading...
Abstract

In order to design and operate an effective water treatment system, a thorough understanding of the process of coagulation-flocculation and filtration is essential in the delivery of water of the greatest clarity and lowest possible turbidity in the finished water. This research outlines the finding of investigation of the treatment plant in Al-Dewanyia in Iraq. Performance of Al-Dewanyia Water Treatment Plant in Iraq is an essential parameter to be monitored and evaluated to better understanding of design and operating difficulties in water treatment plants. The conclusions of these evaluations may determine required recommendations and highlight modification requirements for continuous design and operating schemes. The evaluation conducted in this research was carried out by reviewing the engineering design to assure matching of standards and codes. Also, physical (turbidity and TSS) , and biological, analysis were conducted to investigate water quality. The conclusions drawn from this research outlines the importance of accurate engineering design and need for continuous monitoring and analysis of each unit performance. Finished water is not conforming to World Health Organization (WHO) Standard for Drinking water.

لتصميم و تشغيل محطات معالجة مياه الشرب بكفاءة عالية, يتطلب أدراك شامل لعمليات و مراحل معالجة مياه الشرب من تخثير, تلبيد و ترشيح لغرض أنتاج مياه صالحة للشرب و تقليل العكورة إلى أدنى حدود مسموحه. يلخص هذا البحث تقيم أداء محطة معالجة مياه الشرب في مدينة الديوانية في العراق. يعتبر تقييم أداء محطة معالجة مياه الشرب في مدينة الديوانية عامل ضروري و مهم لمراقبة و تقيم و فهم صعوبات التصميم و التشغيل لمحطات معالجة مياه الشرب في العراق لان معظم محطات المعالجة في العراق لها نفس التصميم الهيدروليكي ومصدر المياه هو النهر (مياه سطحية) و لكن تختلف في مقدار التدفق. في هذا البحث تم تقييم التصميم الهندسي لمحطة المعالجة لغرض التأكد من مطابقته للمحددات التصميمية. و لغرض تقييم نوعية الماء الناتج من المحطة تم قياس العكورة, المواد الصلبة العالقة, و الملوثات الحيوية في مختبر محطة المعالجة. و من أهم نتائج هذه الدراسة هو وجوب الاهتمام بتصميم محطات المعالجة و المراقبة المستمرة لمراحل المعالجة و تحليل أداء كل مرحلة. ان نوعية الماء الناتج ن محطة المعالجة لا يتوافق مع معاير ومحددات منظمة الصحة العالمية لمياه الشرب.


Article
EVALUATION THE EFFICIENCY OF GAS AL- SHAMAL WATER TREATEMENT PLANT
تقييم كفاءة محطة إسالة ماء شركة غاز الشمال

Loading...
Loading...
Abstract

This study gives a description for the units and components of water treatment plant of Gas AL- Shamal Company. The study aimed to evaluation the efficiency of the plant through testing physical and chemical characteristics of raw water and treated water, then comparing with the characteristics of Iraqi drinking water standards. The study showed that the plant was efficient for turbidity and total suspended solids removal. The results appeared that characteristics of the total dissolved solids (T.D.S.), total hardness (T.H.), electrical conductivity (E.C.), chloride (Cl), and sulfate within the characteristics limits of Iraqi drinking water standards for raw and treated water. The results also show that the (pH) values were out of suitable values of flocculation materials. The fluoride values of raw and treated water were low within the standards.

تقدم هذه الدراسة وصفا لوحدات ومكونات محطة إسالة الماء لشركة غاز الشمال وتهدف إلى تقييم عمل وكفاءة المحطة من خلال فحص الخصائص الفيزياوية والكيمياوية للمياه الخام والمياه المعالجة بهذه المحطة ومن ثم مقارنتها مع المواصفات القياسية العراقية لمياه الشرب. بينت الدراسة أن المحطة كفوءة بإزالة العكارة والمواد العالقة و أظهرت أن خصائص الأملاح الذائبة الكلية (T.D.S) والعسرة الكلية (T.H) والايصالية والكلوريد والكبريتات وقعت ضمن الحدود المسموح بها في المواصفات العراقية لكل من الماء الخام والمعالج. أظهرت النتائج أن قيم (PH) تجاوزت الحدود الملائمة لتفاعل المادة الملبدة (الشب). اما قيم الفلوريد في المياه الخام و المعالجة فقد انخفضت عن حدود المواصفة القياسية العراقية.


Article
STOCHASTIC MODELS OF SOME PROPERTIES OF WASTE WATER IN THE MAAMERA SEWAGE TREATMENT PLANT
نماذج عشوائية لبعض خصائص فضلات المياه في محطة معالجة مياه المجاري في المعيميرة

Author: Nabaa Shakir Hadi نبأ شاكر هادي
Journal: Al-Qadisiyah Journal for Engineering Sciences مجلة القادسية للعلوم الهندسية ISSN: 19984456 Year: 2015 Volume: 8 Issue: 2 Pages: 186-198
Publisher: Al-Qadisiyah University جامعة القادسية

Loading...
Loading...
Abstract

The records of influents concentration for both BOD5 and TSS of Maamera sewage treatment plant which were chosen of this study are very important parameters, They play an important part in the planing and management of the national water resources. Most of these records have periods of missing data of the influent BOD5 and TSS. In this study a model for generating missing monthly concentrations influent BOD5 and TSS. Data are introduced. Initially univariate models using the Box-Jenkins approach were fitted to the logarithmically transformed series. Both transformed series were found to be generated by a random process using sampling theory were considered to be white noise. Ordinary regression analysis was performed. No significant correlation between influent BOD5 and TSS concentration were found.

تم في هذا البحث دراسة الخصائص لمياه الفضلات الداخلة لمحطة معالجة المعميرة لأهم المتغيرات الأساسية لنوعية المياه وهي المطلب الحيوي للأوكسجين والمواد الصلبة العالقة, حيث أنها تلعب دورا هاما في التخطيط وإدارة الموارد المائية. معظم هذه البيانات فيها فترات لبيانات مفقودة للمطلب الحيوي للأوكسجين والمواد الصلبة العالقة. تم دراسة موديل بإدخال البيانات الشهرية المفقودة لتركيز المطلب الحيوي للأوكسجين والمواد الصلبة العالقة. موديل احادي المتغير باستخدام طريقة بوكس جينكينز يلائم التحويلات للسلاسل الزمنية. في كل التحويلات للسلاسل يوجد متغير عشوائي بأستخدام نموذج نظري يعبر عنه . وباستخدام تحليل الانحدار تبين عدم وجود ارتباط بين التراكيز الداخلة للمطلب الحيوي للأوكسجين والمواد الصلبة العالقة


Article
Upgrading of Alum Preparation and Dosing Unit for Sharq Dijla Water Treatment Plant by Using Programmable Logic Controller System
تطوير وحدة إضافة جرعة الشب لمشروع ماء شرق دجلة باستخدام منظومة السيطرة المنطقية PLC

Authors: Aumar Al-Nakeeb عمر نجدت النقيب --- Adnan A. Al-Samawi عدنان عباس السماوي --- Huda A. Al-Saffar هدى عدنان الصفار
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2018 Volume: 24 Issue: 2 Pages: 131-141
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

One of the important units in Sharq Dijla Water Treatment Plant (WTP) first and second extensions are the alum solution preparation and dosing unit. The existing operation of this unit accomplished manually starting from unloading the powder alum in the preparation basin and ending by controlling the alum dosage addition through the dosing pumps to the flash mix chambers. Because of the modern trend of monitoring and control the automatic operation of WTPs due to the great benefits that could be gain from optimum equipment operation, reducing the operating costs and human errors. This study deals with how to transform the conventional operation to an automatic monitoring and controlling system depending on a Programmable Logic Controller (PLC) and online sensors for alum preparation and dosing unit in Sharq Dijla WTP. PLC system will receive, analyze transmitting data, compare them with preset points then automatically orders the operational equipment (such as pumps, valves, and mixers) in a way that guarantees the safe and appropriate operation of the unit. As a result of Process and Instrumentation Diagrams (PID) that were prepared in this study, these units can be fully operating and manage by using Supervisory Control and Data Acquisition (SCADA) system.

تعد وحدة تحضير وأضافة الشب من الوحدات المهمة في مشروع ماء شرق دجلة بتوسعيه الأول والثاني. حيث تتم أدارة عمليات تحضير وأضافة الشب في احواض التحضير بصوره يدوية بدءاً من أضافة مسحوق الشب وانتهاءً بعملية تعديل جرع الشب المضافة عن طريق مضخات اضافة جرع الشب الى أحواض المزج السريع. وبالنظر للتوجه الحديث في السيطرة والمراقبة الاوتوماتيكية لمشاريع الماء لما يوفره من منافع متعددة سواء في التشغيل الامثل للمعدات، وتقليل كلف التشغيل والأخطاء البشرية. فهذه الدراسة تعنى بتحويل نظام التشغيل التقليدي لوحدة تحضير واضافة الشب للمشروع الى منظومة سيطرة ومراقبة أوتوماتيكية اعتمادا على جهاز سيطرة مبرمج (PLC) ومتحسسات. حيث تقوم هذه المنظومة باستلام وتحليل البيانات المنقولة ومقارنتها بعدد من القيم مسبقة الضبط وتوجيه الاوامر للمعدات التشغيل (مثل المضخات والصممات واجهزة المزج) بما يضمن التشغيل الامثل والأمن لهذه الوحدة. كنتيجة لمخططات أجهزة العمليات PID المعدة في هذه الدراسة، يمكن لهذه الوحدات ان تشغل وتدار بواسطة منظومة التحكم الاشرافي واستحصال البيانات SCADA.