Article
Generalized Λgs-Sets and Generalized Vgs- Sets
Vgs-و المجموعات العامة Λgs- المجموعات العامة

Authors: Alan Jalal Abd Alqader ئالان جلال عبد القادر --- Dalal Ibraheem Resan دلال ابراهيم رسن
Journal: Journal of College of Education مجلة كلية التربية ISSN: 18120380 Year: 2012 Issue: 3 Pages: 112-120
Publisher: Al-Mustansyriah University الجامعة المستنصرية

Loading...
Loading...
Abstract

In this paper , we introduced a new concepts of generalized Λgs - sets ( breifly.g. Λgs- sets ) and generalized Vgs- sets (breifly. g.Vgs- sets ) and study its connection with Λgs- (resp. Vgs-) sets ,we give some results about that.

في هذا البحث سوف نقدم مفهومي المجموعات الاعم- Sᶢ˄و- ˢᵍ˅ كماسندرس ارتباطهما مع المجموعات- Sᶢ˄و- ˢᵍ˅ سوف نعطي بعض النتائج حول ذلك•


Article
Numerical and Experimental Investigations of Heat Transfer Enhancement in a Duct Heater with Different Areas of Vortex Generators
محاكاة نظرية وعملية لتأثير المساحات لمولدات الدوامات على تحسين انتقال الحرارة في مجرى في داخلة مسخنات كهربائية

Authors: Afrah Turki Awad افراح تركي عواد --- Kutaeba J. M. Al-Khishali قتيبة جميل الخشالي
Journal: AL-NAHRAIN JOURNAL FOR ENGINEERING SCIENCES مجلة النهرين للعلوم الهندسية ISSN: 25219154 / eISSN 25219162 Year: 2017 Volume: 20 Issue: 1 Pages: 88-104
Publisher: Al-Nahrain University جامعة النهرين

Loading...
Loading...
Abstract

Numerical and experimental investigations were carried out on the effect of the vortex generators on the flow field and heat transfer from duct heaters. The flow Reynolds number ranging from 32000اجريت محاكاة نظرية و عددية لمعرفة تأثير المساحات المختلفة لمولدات دوامات (شبكة دوائر صغيرة و شبكة دوائر كبيره) على مجال الجريان و انتقال الحرارة من مجرى بداخله ملفات تسخين كهربائية و لقيم رينولدز مختلفة من 32000 الى 83000 مع ثبوت الفيض الحراري=43.09426 كيلو واط/م2.بالمحاكاة العددية تم استخدام برنامج الفلونت (3,6) مع حلول بالفرضيات التالية : جريان مستقر و ثلاثي الابعاد وكذلك حل معادلات الاستمرارية¸ معادلات الزخم و معادلات الطاقة باستخدام نموذج(k-ε)القياسي.باستخدام برنامج الفلونت تم استنتاج ان وجود مولدات الدوامات يحفظ الطاقة بمقدار 27% من طاقة المسخنات بتأثير زيادة مساحة مولدات الدوامات (كنسبة نصف قطر مولدات الدوامات ذات المقطع الدائري الكبير الى نصف قطر مولدات الدوامات ذات المقطع الدائري الصغير=1.5) ولنفس الشكل على اداء المسخنات.النتائج العملية تبين انه هنالك تحسين بانتقال الحرارة بوجود مولدات الدوامات.حيث يعتمد تحسين انتقال الحرارة على مساحه مولدات الدوامات و تبين ان ذات النوع الدائري الكبيره هي أفضل في تحسين انتقال الحراره بمقدار (2.76%-4.11%) في حالة وجود ثلاثة صفوف من مولدات الدوامات وعلى بعد 2سم قبل او بين المسخنات و مولدات الدوامات.ان الزيادة في: (مساحة مولدات الدوامات,عدد صفوف مولدات الدوامات ,المسافة بين أي صفين من مولدات الدوامات والمسخنات)هذه تعتبر اكثر العوامل المؤثرة على تحسين انتقال الحرارة.


Article
An Experimental Study on the Effect of Shape and Location of Vortex Generators Ahead of a Heat Exchanger
دراسة عملية عن تأثير شكل وموقع مولدات الدوامات عند مدخل المبادل الحراري

Author: Wisam Abed Kattea وسام عبد كاطع
Journal: Al-Khwarizmi Engineering Journal مجلة الخوارزمي الهندسية ISSN: 18181171 23120789 Year: 2012 Volume: 8 Issue: 2 Pages: 12-29
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

An experimental study is carried out on the effect of vortex generators (Circular and square) on the flow and heat transfer at variable locations at (X = 0.5, 1.5, 2.5 cm) ahead of a heat exchanger with Reynolds number ranging from 62000< Re < 125000 and heat flux from 3000 ≤ q ≤ 8000 W/m2 .In the experimental investigation, an apparatus is set up to measure the velocity and temperatures around the heat exchanger. The results show that there is an effect for using vortex generators on heat transfer. Also, heat transfer depends on the shape and location. The circular is found to be the best shape for enhancing heat transfer at location [Xm=0.5 cm] distance before heat exchanger is the best location for enhancing heat transfer. The square is the best shape for enhancing heat transfer at location [Xm=2.5 cm] distance before heat exchanger is the best location for enhancing heat transfer.The results of flow over heat exchanger with vortex generators are compared with the flow over heat exchanger without vortex generators. Heat transfer around heat exchanger is enhanced (56%, 50%, 36%) at location (X=0.5, 1.5, 2.5cm) respectively by using circular vortex generators without turbulator and heat transfer around heat exchanger is enhanced (39%, 42%, 51%) at location (X=0.5, 1.5, 2.5cm) respectively by using square shape vortex generators without turbulator.

دراسة عملية أجريت لفحص تأثير مولد الدوامات ( الشبكة الدائرية ، الشبكة المربعة ) على الجريان و انتقال الحرارة عند مواقع (X = 0.5, 1.5, 2.5 cm) قبل مبادل حراري ضمن مدى لرقم رينولد 62000< Re < 125000 و فيض حراري 3000 ≤ q ≤ 8000 W/m2.في الدراسة العملية تم نصب و صيانة جهاز مختبري لقياس السرعة و درجة الحرارة حول المبادل الحراري.أظهرت النتائج أن لوجود مولد الدوامات اثر كبير على تحسين انتقال الحرارة ويعتمد هذا على شكل المولد وموقعهِ. الشبكة الدائرية هي الأفضل لعملية نقل الحرارة عند موقع [Xm=0.5 cm] قبل المبادل الحراري. الشبكة المربعة هي الأفضل لعملية نقل الحرارة عند موقع [Xm=2.5 cm]قبل المبادل الحراري. قورنت النتائج العملية في حالة وجود مولد الدوامات مع عدم وجود مولد الدوامات. أظهرت هذه المقارنة تحسن في انتقال الحرارة حول المبادل الحراري بنسب (56%, 50%, 36%)عند مواقع (X=0.5, 1.5, 2.5cm )على التوالي بأسنخدام مولد الدوامات الدائري الشكل نسبةً الى عدم وجود عوائق جريان،وانتقال الحرارة حول المبادل الحراري يتحسن بنسب (39%, 42%, 51%)عند مواقع (X=0.5, 1.5, 2.5cm ) على التوالي بأسنخدام مولد الدوامات المربع الشكل نسبةً الى عدم وجود عوائق جريان.