research centers


Search results: Found 2

Listing 1 - 2 of 2
Sort by

Article
Evaluation The Accuracy Of Modified Closed Tray Impression Technique For Multiple Angled Implants Using Condensation-Silicone Impression Material

Authors: Osama A Hammoodi --- Lamia T Rejab --- Wael T Alwattar
Journal: Al-Rafidain Dental Journal مجلة الرافدين لطب الأسنان ISSN: 18121217 Year: 2013 Volume: 13 Issue: 23 Pages: 413-422
Publisher: Mosul University جامعة الموصل

Loading...
Loading...
Abstract

Aims: is to evaluate the linear distance accuracy of new modified closed tray impression technique of 6 angled implants and compared with open tray technique using condensation silicone impression material. Materials and Methods: : standard master model was prepared with six angled implants analogues (25 degree) buccaly and labial deviated .Two impression techniques were performed (open tray and new modified splinted closed tray) using condensation silicone impression material , then poured with die type IV stone. Capturing of the standard model and stone casts produced from both impression techniques. To perfume the measurement, first determine and label the reference points and reference line on standard model then measure the linear distances and angles with Matalab software program (7.12.0.635(R2011a). The entire measurements of the stone models were done by coordination way of implants analogues in sequence .Total number of impressions was ten, five impression for each technique. Statistically one sample t-test and two sample t-tests were performed to determine the significance differenc at p ≤ 0.05. Results: appeared there is no significance difference of the linear distances and angles of standard model and stone casts for open tray and a new modified closed splinted techniques. Conclusion: A new modified closed splinted technique is an accurate impression technique for multiple angled (6) implants as same as the open tray technique with condensation silicon, so a new technique is an accurate and easier technique to be carried out with multiple angled non- parallel implants.


Article
Tilted Implant Technique Solved Numerous Limitation of Straight Technique

Authors: Natheer A.Jassem نذير عايد علي --- Nabaa A. Ali نبأ علي
Journal: Tikrit Journal for Dental Sciences مجلة تكريت لعلوم طب الاسنان ISSN: 20731213 Year: 2016 Volume: 4 Issue: 2 Pages: 157-162
Publisher: Tikrit University جامعة تكريت

Loading...
Loading...
Abstract

Present of important anatomical structures in both upper and lowerjaws make challenge during planning for implant procedures in theatrophic alveolar bone and to overcome this problem need boneaugmentation which still complex and difficult procedures make itnot accepted by large number of patient. In this study we spot lighton the teeth implant in an area where short bone or insufficientheight of alveolar ridge and inclined alveolar ridge so when weplace implant should be tilted either palatelly, mesially or distallyin bone around and we compare the success rate between angledplaced implant and up right placed implant. 61 patients came toclinic asking for tooth or teeth implant, 300 implant fixtures wereplaced in both upper and lower arch 203 implants were straightand 97were tilted. After 24 months follow up in the upper andlower alveolar arches of dental implant (97.54%) of uprightimplant were success and (97.94%) of tilted implant were success.Results indicate that the use of tilted implants effective and safemethod over bone augmentation procedures and nervetransferring.

Listing 1 - 2 of 2
Sort by
Narrow your search

Resource type

article (2)


Language

English (1)


Year
From To Submit

2016 (1)

2013 (1)