research centers


Search results: Found 13

Listing 1 - 10 of 13 << page
of 2
>>
Sort by

Article
Experimental Study For Effect of Aspect Ratio on Forced Convection Heat Transfer Inside a Rectangular Cross- Sectional Duct
دراسة عملية لبيان تأثير النسبة الباعية على انتقال الحرارة بالحمل القسري داخل مجرى مستطيل المقطع

Author: Hayder Azeez Neamah حيدر عزيز نعمة
Journal: KUFA JOURNAL OF ENGINEERING مجلة الكوفة الهندسية ISSN: 25230018 Year: 2012 Volume: 3 Issue: 2 Pages: 31-45
Publisher: University of Kufa جامعة الكوفة

Loading...
Loading...
Abstract

The effect of aspect ratio on the forced convection heat transfer is studied experimentally by construction a device formed mainly from an air duct with sliding surfaces to up or down directions and from a copper tube represents a heat generation source placed inside the air duct. The aspect ratio considered the ratio of the distance between the upper and lower surfaces of the air duct to diameter of the copper tube. The experimental results which obtained from this study show that the Nusselt number decreases with increase of the aspect ratio for Reynolds number range equals to (500 < Re < 3000). From the experimental results, a correlation for Nusselt number calculation is presented that depending on the effect of Reynolds number, Prandtl number, and aspect ratio with an accuracy of ±8%.

تم دراسة تأثير النسبة الباعية على انتقال الحرارة بالحمل ألقسري عمليا من خلال إنشاء جهاز يتكون بصورة رئيسية من مجرى للهواء ذو سطحين علوي وسفلي قابلين للحركة باتجاه الأعلى أو الأسفل ومن أنبوب نحاسي كمصدر للحرارة المتولدة موقعه داخل مجرى الهواء. تم اعتماد النسبة الباعية على إنها النسبة بين المسافة بين السطحين العلوي والسفلي لمجرى الهواء إلى قطر الأنبوب الساخن. إن النتائج العملية التي تم الحصول عليها من هذه الدراسة بينت بأن رقم نسلت يقل بزيادة النسبة الباعية لمدى من رقم رينولدز مساو لـ (500 < Re < 3000). من النتائج العملية تم استخراج علاقة لحساب رقم نسلت بالاعتماد على رقم رينولدز ورقم براندل والنسبة الباعية بنسبة خطأ±8% .


Article
Natural Convection Heat Transfer in Horizontal Concentric Annulus between Outer Cylinder and Inner Flat Tube
انتقال الحرارة بالحمل الحر في أنبوب حلقي أفقي متحد المركز بيناسطوانة خارجية وأنبوب مسطح داخلي

Loading...
Loading...
Abstract

Natural convection heat transfer in two-dimensional region formed by constant heat flux horizontal flat tube concentrically located in cooled horizontal cylinder studied numerically. The model solved using the FLUENT CFD package. The numerical simulations covered a range of hydraulic radius ratio (5, 7.5, and 10) at orientation angles from (0o up to 90o).
The results showed that the average Nusselt number increases with hydraulic radius ratio, orientation angles and Rayleigh number. As well as enhancement ratio for Nusselt number at orientation angle 90o and hydraulic radius ratio 7.5 equal 24.87%. Both the fluid flow and heat transfer characteristics for different cases are illustrated velocity vectors and temperature contours that obtained from the CFD code. The results for the average Nusselt numbers are compared with previous works and show good agreement.

تضمن البحث دراسة عددية لانتقال الحرارة بالحمل الحر في منطقة ثنائية الأبعاد لأنبوب حلقي أفقي متحد المركز بين أنبوب مسطح عند فيض حراري ثابت داخل اسطوانة مبردة. تم حل النموذج الرياضي باستخدام برنامج معد خصيصا للحل العددي (FLUENT CFD package)، تناولت المحاكاة العددية مدى نسبة أنصاف الأقطار الهيدروليكية (5، 7.5، 10) عند زاويا توجية من °0 الى°90. بينت النتائج بأن متوسط عدد نسلت يزداد بزيادة كل من نسبة نصف القطر الهيدروليكي، زوايا توجيه الأنبوب المستوي وعدد رايلي، وجد أن أفضل نسبة تحسن لقيم عدد نسلت عند زاوية توجية °90 و نسبة أنصاف الأقطار الهيدروليكية (7.5) هي (24.87%). مثلت خصائص جريان المائع وانتقال الحرارة لحالات مختلفة بمخططات درجة الحرارة ومتجه السرعة. عند مقارنة نتائج البحث الحالي مع البحوث السابقة تم الحصول على توافق جيد.


Article
Bending Moment Influence Surfaces For Rectangular Concrete Plates Simply Supported At Three Edges And Built-In At The Fourth Edge

Authors: Zena R. Al-Ani --- Sabah S. Razouki
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2010 Volume: 16 Issue: 2 Pages: 4795-4821
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

Presented in this paper is a series of bending moment influence surfaces for concrete rectangular plates simply supported at three edges and built-in at the fourth edge. The solutions are obtained analytically on the basis of thin plate's theory with small deflection using double Fourier series. The influence surfaces are presented for two observation points namely the center of the plate as well as the midpoint of the built-in edge. A computer program was written in FORTRAN language to generate the influence surfaces making use of the developed analytical solutions of this work. The validity of the computer solution was confirmed by comparing its results with published results for zero Poisson's ratio and excellent agreement was obtained. An application of the influence surfaces for the case of a line load as well as a strip load is also presented. The paper reveals that the bending moment influence surfaces depend on the actual value of Poisson's ratio, aspect ratio of the plate, and position of the observation point.

يقدم هذا البحث حلولا" تحليلية لسطوح التأثير لعزوم الانحناء لألواح كونكريتية مستطيلة بسيطة الاسناد في ثلاثة حافات و مبنية في حافتها الرابعة اعتمادا" على نظرية الألواح النحيفة ذات الأود القليل. أن سطوح التأثير التي تم تطويرها في هذا البحث , قد خصصت لأيجاد عزوم الانحناء في نقطتين من نقاط الملاحظة : الاولى في مركز اللوح و الثانية في نقطة الوسط للحافة المبنية .لقد تم كتابة برنامج على الحاسبة بلغة الفورتران لغرض أيجاد سطوح الانحناء و ذلك بالاعتماد على الحلول التحليلية التي تم تطويرها في هذا البحث. أظهرت مقارنة النتائج للحلول التحليلية التي طورت في هذا العمل توافقا" ممتازا" مع نتائج حلول متوفرة لنسبة بوسون تساوي صفر.ان البحث يبين بأن سطوح التأثير لعزوم الانحناء تعتمد على نسبة بوسون والنسبة بين أبعاد اللوح (الطول/العرض) و موقع نقاط الملاحظة.


Article
EFFECT OF ECCENTRICITY ON THE PRESSURE AND VELOCITY GRADIENTS ALONG A STREAMLINE PAST A CYLINDERICAL BODY
تأثير معامل المركزية على تدرج السرعة والضغط على طول خطوط الجريان حول جسم اسطواني

Author: Ali A. Jazie Al-Khaledy علي عبد الحسين جازع
Journal: Al-Qadisiyah Journal for Engineering Sciences مجلة القادسية للعلوم الهندسية ISSN: 19984456 Year: 2009 Volume: 2 Issue: 2 Pages: 459-476
Publisher: Al-Qadisiyah University جامعة القادسية

Loading...
Loading...
Abstract

In chemical technology and power engineering, equipment containing heat exchanging pipes and various cylindrical links immersed into moving fluid was often used. The estimation of the hydrodynamic action on these elements is based on the solution of the plane problem on the flow past a cylinder. In the hydrodynamics of inviscid flow past a body of nonzero thickness, it was assumed that there are regions near the body in which the flow accelerates from the front stagnation point to the midsection and decelerates behind the midsection. According to the Bernoulli theorem, a pressure counter-gradient arises in the deceleration region, which acts both in the outer flow and in the boundary layer. For the inviscid flow, the fluid particles store sufficiently much kinetic energy in the acceleration region to overcome this barrier, but in the frictional flow, the fluid particles that remain in the boundary layer cannot reach the region of higher pressure. They are pushed away from the wall, and an opposite flow arises downstream. This phenomenon is known as the boundary layer separation. A CFD models were simulated for the viscous flow past bodies changed from a circular cylinder to flat plate. FLUENT 6.3.26 package was used for solving the model preprocessed in GAMBIT 2.3.16 for flow past a body. Fluent solvers were based on the finite volume method and general conservation (transport) equation for momentum was discretized into algebraic equations. The pressure and velocity gradients for viscous flow past bodies changed from a circular cylinder to flat plate was predicted and plotted and the effect of eccentricity on the pressure and velocity gradients was studied.

في الهندسة الكيمياوية وهندسة الطاقة , عادة تستخدم المعدات التي تحتوي على أنابيب التبادل الحراري و الاسطوانات المختلفة المغمورة داخل مائع متحرك.حساب التأثير الهيدروديناميكي على هذه العناصر معتمد على حل مسالة الجريان حول اسطوانة .في هيدروديناميكية الموائع الغير لزجة ( inviscid flow ) حول جسم ذو سمك لايساوي صفر يفترض بان هنالك مناطق بالقرب من الجسم فيها الجريان يعجل من نقطة الركود الى منتصف المقطع ثم يثبط بعد منصف المقطع .طبقا الى نظرية برنولي ,تدرج ضغط ينشا في هذه المنطقة والذي يؤثر على كلا الجريان الخارجي والطبقة المتاخمة. بالنسبة للجريان الغير لزج ,جسيمات المائع تختزن كمية كافية من الطاقة الحركية في منطقة التعجيل لتتغلب على ذلك ولكن في الجريان الاحتكاكي ,جسيمات المائع الباقية في الطبقة المتاخمة لايمكن ان تصل الى منطقة الضغط العالي .هذه الجسيمات يتم دفعها بعيدا عن الجدار وهنا ينشا جريان باتجاه معاكس .هذه الظاهرة تعرف بمصطلح انفصال الطبقة المتاخمة. في هذا البحث تم استخدام (CFD models ) لجريان لزج حول جسم اسطواني متغير الشكل للمقطع من اسطوانة دائرية الى صفيحة مستوية.تم استخدام برنامج ( FLUENT 6.3.26 ) لحل الموديل المعالج مسبقا باستخدام( GAMBIT 2.3.16 ) للجريان حول جسم اسطواني .برنامج ( FLUENT 6.3.26 )معتمد على طريقة الحجم المحدد ومعادلات الحفظ العامة للكتلة والزخم والطاقة والتي يتم تجزئتها الى معادلات جبرية . في هذا البحث تم تحري كيفية تغير تدرج السرعة والضغط بالنسبة لجريان لزج حول اجسام متغيرة الشكل بدءا بالاسطوانة الدائرية وانتهاء بالصفيحة المستوية وتم رسم النتائج وبيان تاثير تغير الشكل على تدرج السرعة والضغط.


Article
Experimental Study of Mixed Convection in an Enclosure with a Cold Movable Top Wall and Hot Bottom Wall
دراسة تجريبية للحمل المختلط داخل مغلف ذو سطح علوي متحرك بارد وسطح سفلي ساخن

Loading...
Loading...
Abstract

Mixed convection heat transfer to air inside an enclosure is investigated experimentally. The bottom wall of the enclosure is maintained at higher temperature than that of the top wall which keeps in oscillation motion, whereas the left and right walls are well insulated. The differential temperature of the bottom and top walls changed several times in order to accurately characterize the temperature distribution over a considerable range of Richardson number. Adjustable aspect ratio box was built as a test rig to determine the effects of Richardson number and aspect ratio on the flow behavior of the air inside the enclosure. The flow fields and the average Nusselt number profiles were presented in this work. The results show that, at a constant value of the Richardson number, average Nusselt number (Nuav.) increases with aspect ratio. Furthermore, as Richardson number decreases, the time period decreases with constant values of aspect ratio.

انتقال الحرارة بالحمل المختلط إلى الهواء داخل حيز مغلق تمت دراسته تجريبيا. ثبتت درجة حرارة السطح السفلي للحيز المغلق لتكون أعلى من درجة حرارة السطح العلوي وحرك السطح العلوي بحركة ترددية ثابتة، فيما تم عزل السطحين الجانبيين حراريا. الفرق بدرجات الحرارة للسطحين العلوي والسفلي غيرت عدة مرات لتتم المراقبة الدقيقة للتوزيع الحراري داخل الحيز المغلق مع تغير عدد ريجاردسون. تم استخدام صندوق يمكن تغيير نسبة طوله الى ارتفاعه كحقل اختبار لغرض تحديد تأثير عدد ريجاردسون ونسبة الطول الى الارتفاع على شكل الحركة الهوائية داخل الحيز. تم عرض مخططات كنتورية لحركة الهواء ومعدل عدد نسلت داخل الحيز في هذا العمل. أظهرت النتائج ان معدل عدد نسلت يزداد مع نسبة الطول الى الارتفاع بثبوت عدد ريجاردسون. كما إن نقصان عدد ريجاردسون يقلل من الفترة الزمنية بثبوت نسبة الطول الى الارتفاع.


Article
Numerical Investigation of Unsteady Mixed Convection Heat Transfer In ventilated enclosure With Different Aspect Ratio
دراسة عددية لانتقال الحراة بالحمل المختلط غير المستقر داخل حيز مهوى لقيم مختلفة من نسبة ارتفاع الحيز الى طوله

Authors: Amir S. Dawood1 د. أمير سلطان داؤد --- Ali A. Mohammed علي عزام محمد
Journal: AL Rafdain Engineering Journal مجلة هندسة الرافدين ISSN: 18130526 Year: 2015 Volume: 23 Issue: 4 Pages: 143-156
Publisher: Mosul University جامعة الموصل

Loading...
Loading...
Abstract

Unsteady mixed convection heat transfer of a laminar fluid flow in ventilated enclosure was studied numerically. Thebottom horizontalsurface was considered isothermal, whereas the other walls were considered adiabatic. The fluid enters into enclosure through a hole located at the bottom of the left vertical wall and exits from the top of the opposite wall. The mathematical model is governed by two dimensional conservations of mass, momentum and energy equations. The numerical simulations of the fluid flow and heat transfer were investigated with a range of Reynolds number (50-500) and Richardson number (0-10), with Prandtl number fixed at 0.71. The effect of the aspect ratio on the fluid flow and heat transfer characteristics in the enclosure was studied in three different values (0.5, 1, 1.5 ). The numerical results showed that the maximum value of the average Nusselt number was achieved at aspect ratio of 0.5. Also, the average Nusselt number increases with the increase of Richardson and Reynolds numbers for whole different cases.

يقدم البحث دراسة عددية لانتقال الحرارة بالحمل المختلط غير المستقر لجريان المائع الطباقي في حيز مهوى. يعتبر الحيز المهوى معزول حراريا عدا السطح السفلي له حيث يعتبر ذو درجة حرارة ثابتة المقدار. يدخل المائع الى الحيز المهوى من المنطقة السفلى للجدار الايسر، في حين يخرج من المنطقة العليا للجدار المقابل. المعادلات الحاكمة التي تُمثّلالانموذج الرياضياتي هي معادلة حفظ الكتلة ومعادلة حفظ الزخم ومعادلة حفظ الطاقة. أُجريت المحاكاة العددية لجريان المائع وانتقال الحرارة لمدى واسع من قيم عدد رينولدز يتراوح بين (500- 50) ومدى من قيم عدد ريشاردسون يتراوح بين (10-0) مع اعتبار قيمة عدد برانتل ثابتة المقدار 0.71. تم دراسة ثلاث قيم مختلفة لتغيير نسبة ارتفاع الحيز الى طوله وهي (0.5 , 1 , 1.5 )، ومدى تأثيرها على خواص الجريان وانتقال الحرارة خلال الحيز المهوى. اوضحت النتائج ان معدل عدد نسلت يبلغالقيمة العظمى له عندما تكون نسبة ارتفاع الحيز الى طوله 0.5. وكذلك اوضحت النتائج ان معدل عدد نسلت يزداد بزيادة كل من عدديرينولدزوريشاردسون ولجميع الحالات المدروسة.


Article
EFFECT OF USING MIRRORS ON THE EFFICIENCY OF SILICON SOLAR CELL TEXTURED WITH TRIANGULAR GROOVES BY USING ZEMAX

Authors: Basma Nazar Nadhim --- Mustafa Mahdi Ali --- Mustafa Abbas Fadel
Journal: Journal of Engineering and Sustainable Development مجلة الهندسة والتنمية المستدامة ISSN: 25200917 Year: 2018 Volume: 22 Issue: 2 (Part-4) Pages: 63-72
Publisher: Al-Mustansyriah University الجامعة المستنصرية

Loading...
Loading...
Abstract

Solar cell (photovoltaic cell)efficiency depends on the amount of sunlight falling on its surface and reflection within the cell. Different methods are used to improve solar cell efficiency. In this paper, we use triangular grooves on the upper surface of the silicon cell to reduce outside reflection on the surface of the cell and increase the internal reflection withinthe cell by putting mirrors on the four sides of the cell. We compare the performance of this cell using the Zemax program for different aspect ratio (A.R) values and incident angles of the rays against another cell with triangular grooves and no mirrors. For A.R=1,with a parallel incidence angle of the triangular grooves of"θ" ^"°" = 〖"50" 〗^"°" , the number of rays that hit the detector is equal to2998 in the case of using mirrors. However, it was equal to 1200 without mirrors with across incidence angle of the triangular grooves of"θ" ^"°" = 〖"20" 〗^"°" and A.R =1thenumber of rays for the case using mirrors was equal to 2960,and 1000 without mirrors.


Article
Effect of Obstacle in River on the Heat Dissipation of Hot Water Injection

Author: Ayser M. Fleh
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2009 Volume: 15 Issue: 1 Pages: 3443-3465
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

Numerical analysis of the cooling process of hot water discharge from a steam power plant into a river has been carried out in the present study. A mathematical model describing the flow field and temperature distribution induced in the river as a result of the cooling process is made based upon the assumptions of steady state, two-dimensional, turbulent flow, in the horizontal plane. The governing equations are the continuity, the momentum, the (К-ε) turbulence model and the energy equation. A proper initial and boundary condition are specified to be used in the solution of the governing equations. A numerical solution of the governing equations is made by using the control volume approach, with non-staggered grid technique and modified SIMPLE algorithm. The numerical solution is capable of calculating the velocity and temperature distributions of the calculation domain. The numerical results show that the developed algorithm is capable of calculating the flow field, properly and accurately. Results are obtained for ten cases of configuration, constant aspect ratio and weather conditions for Baghdad. The results show that the injection velocity effect on the temperature distribution and stream line , the exist of obstacle and its distance from the injection zone but the increase in injection temperature cause a small effect on temperature distribution and stream line.

تقدم هذه الدراسة تحليلا عدديآ لعملية تبريد الماء الساخن المتدفق من مكثفات محطات الطاقة الكهربائية الى النهر. فقد تم وضع نموذجآ رياضيا يصف طبيعة الجريان والتوزيع الحراري الحاصل في النهر نتيجة لعملية التبريد تلك, وقد أعتمد هذا النموذج على فرضيات منها حالة ألاستقرار,ثنائي البعد، الجريان مضطرب في المستوى الأفقي. يتضمن النموذج الرياضي أشتقاق المعادلات التفاضلية الجزئية للمسألة، والتي هي معادلات الاستمرارية، الزخم، معادلتي نموذج (K-E) للاضطراب ومعادلة الطاقة. بالاضافة الى ذلك . تم تعريف ظروف أبتدائية وحدية مناسبة لاستخدامها في حل المعادلات. تم حل المعادلات عدديآ بأستخدام تقنية الحجم المحكوم مع شبكة غير مزحفة وطريقة (SIMPEL ) المعدلة. للحل العددي القابلية على حساب توزيعات السرع ودرجات الحرارية. أظهرت النتائج العددية ان النموذج العددي الذي تم التوصل أليه له القابلية على حساب الجريان بصورة مناسبة ودقيقة ولقيمة ثابتة(نسبة طول النهر الى عرضها aspect ratio) وللظروف الجوية لمدينتة بغداد.ولقد أظهرت النتائج مياه النهر القريب من منطقة التدفق تتأثربزيادة سرعة التدفق,زيادة درجة الحرارة,قرب وبعد الجسم العائق وكذلك وجود العائق وتتأثر قليلا بزيادة درجة الحرارة.


Article
Comparison between a Heat Pipe and a Thermosyphon Performance with Variable Evaporator Length_ENG
مقارنة بين أداء أنبوب حراري وسيفون حراري مع مبخر متغير الطول

Authors: Dr. Hussain H. Ahmad د. حسين حامد احمد --- Anwar A. Yousif أنوار احمد يوسف
Journal: AL Rafdain Engineering Journal مجلة هندسة الرافدين ISSN: 18130526 Year: 2013 Volume: 21 Issue: 2 Pages: 1-12
Publisher: Mosul University جامعة الموصل

Loading...
Loading...
Abstract

AbstractHeat pipes and two phase thermosyphons are heat transfer devices whose operating principles are based on the evaporation/condensation of a working fluid using the capillary pumping forces (in the case of heat pipe) and gravity forces (in the case of two phase thermosyphons) to ensure the fluid circulation. The two systems were designed and constructed to investigate the performance and the affecting parameters, using ethanol as a working fluid. The affecting parameters which were studied are power input (200≤Q≤700) W, working fluid filling ratios (35% and 85%) and aspect ratio, the ratio of evaporator length to inner diameter, (4.0, 7.8 and11.5) . The experimental results showed that the best performance of heat pipe obtained at aspect ratio (7.8) and (85%) filling ratio at (500) W where the maximum heat transfer coefficient was (9950) W/m2.oC, while for the two phase thermosyphon the best performance was obtained at aspect ratio (4.0) for (35%) filling ratio and power input (600) W with maximum heat transfer coefficient equals to(4590) W/m2.oC. The overall comparison between the two systems showed that the performance of the heat pipe is better than that of the two phase thermosyphon. The experimental results of heat pipe was compared with theoretical and empirical correlations showing reasonable agreement especially with immura with percent 70%.KEY WORDS: heat pipe, two phase thermosyphon, aspect ratio, filling ratio

الخلاصةالأنبوب الحراري والثرموسيفون الحراري ثنائي الطور هي أجهزة نقل حرارة تعتمد مبادئ تشغيلها على تبخر وتكثف المائع التشغيلي وذلك بالاعتماد على قوى الخاصية الشعرية في حالة الأنبوب الحراري والجاذبية في حالة الثرموسيفون الحراري ثنائي الطور لتدوير المائع التشغيلي. المنظومتان تم تصميمهما و تصنيعهما لتحري الكفاءة والعوامل المؤثرة وباستخدام الأيثانول كسائل تشغيلي. العوامل المؤثرة التي تم دراستها هي: القدرة المجهزة200≤Q≤700) W) ،نسبة مائع التشغيل ( 35%و 85%) والنسبة الباعية، وهي نسبة طول المبخر إلى القطر الداخلي، (4.0, 7.8, 11.5). النتائج العملية أظهرت أن أعلى كفاءة للأنبوب الحراري كانت عند النسبة الباعية (7.8) ونسبة مائع التشغيل (85%) عندما كانت القدرة المجهزة500) W) حيث كان أعلى معامل لانتقال الحرارة هو9950) W/m2.oC) بينما بالنسبة للثرموسيفون الحراري ثنائي الطور فان أعلى كفاءة كانت عند النسبة الباعية (4.0) ونسبة مائع التشغيل (35%) و القدرة المجهزة هي600) W) حيث كان أعلى معامل لانتقال الحرارة يساوي(4590) W/m2.oC. المقارنة العامة بين المنظومتين أظهرت أن الأنبوب الحراري كان أعلى كفاءة من الثرموسيفون الحراري ثنائي الطور. النتائج العملية لكلا المنظومتين تم مقارنتها مع علاقات نظرية وتجريبية و أظهرت المقارنة أن التوافق كان بمقدار70%.


Article
INVESTIGATION THE EFFECT OF ASPECT RATIO ON THE FREE HEAT CONVECTIVE INSIDE A HORIZONTAL HEATED TUBE
دراسة تأثير نسبة الطول الى القطر على الحمل الحراري الحر داخل أنبوب أفقي مسخن

Author: Saad Najeeb Shehab Saad Najeeb Shehab Saad Najeeb Shehab
Journal: Journal of Engineering and Sustainable Development مجلة الهندسة والتنمية المستدامة ISSN: 25200917 Year: 2017 Volume: 21 Issue: 3 Pages: 119-135
Publisher: Al-Mustansyriah University الجامعة المستنصرية

Loading...
Loading...
Abstract

In this work, an experimental investigation has been done for steady-state free heat convection into a heated externally horizontal open ends circular tube with and without internal ring fins. The tests are carried out for five different aluminum tubes in aspect ratios. Another four tubes are used providing internal ring fins with varying fin spacing and constant aspect ratio . Wide levels of the wall heat fluxes (254 - 2267) W/m2 are used. The influence of aspect ratio , heat flux , ring fins , fin spacing on the free-convection through a heated tube are analyzed and discussed. The experimental results indicate that the local Nusselt number increases with decreasing the aspect ratio. Also the results appear that the free heat convection performance through the tube in terms of local Nusselt number improved with internal fins about 25% higher than without fins. An experimental correlations of local and average Nusselt numbers as a function of Rayleigh number for a wide range of aspect ratios under uniform wall heat flux condition are concluded.

في هذا البحث أجريت دراسة عملية للحمل الحراري الحر في الحالة المستقرة داخل أنبوب دائري مسخن من الخارج مفتوح النهايتين بوجود وبدون وجود زعانف حلقية داخلية . أجريت الأختبارات لخمسة أنابيب من الألمنيوم مختلفة في نسبة الطول الى القطر. كما أستخدمت أربع أنابيب أخرى تحتوي على زعانف حلقية داخلية بمسافات مختلفة للزعانف ومتساوية بنسبة الطول الى القطر. أستخدمت عدة مستويات للفيض الحراري لجدار الأنبوب (254 - 2267) واط/م2. تم تحليل و مناقشة تأثير كل من نسبة الطول الى القطر و الفيض الحراري ووجود الزعانف الحلقية و المسافات البينية بينها على الحمل الحر داخل الأنبوب المسخن . تشير النتائج العملية بأن رقم نسلت الموقعي يزداد مع نقصان نسبة الطول الى القطر. كذلك بينت النتائج أن أداء الحمل الحراري الحر خلال الأنبوب بدلالة رقم نسلت الموقعي بوجود الزعانف الحلقية الداخلية يزداد بحدود 25% مقارنة بعدم وجود الزعانف. أستنتجت علاقتين أرتباطيتين عمليتين لرقم نسلت الموقعي والمعدل كدالة لرقم ريليه لمدى واسع من نسب الطول الى القطر بثبوت الفيض الحراري.

Listing 1 - 10 of 13 << page
of 2
>>
Sort by
Narrow your search

Resource type

article (13)


Language

English (10)

Arabic and English (3)


Year
From To Submit

2018 (2)

2017 (2)

2015 (1)

2014 (1)

2013 (1)

More...