Calibration of ionization chamber survey meter
معايرة جهاز القياس الإشعاعي (غرفة التأين)

Authors: Ali Kareem Kadhim علي كريم كاظم --- Taiman Bin Kadni تايمان بن كادني
Journal: Iraqi Journal of Physics المجلة العراقية للفيزياء ISSN: 20704003 Year: 2016 Volume: 14 Issue: 29 Pages: 198-208
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

Radiation measuring devices need to process calibration which lose their sensitivity and the extent of the response and the amount of stability under a changing conditions from time to time and this period depends on the nature and use of field in which used devices. A comparison study was done to a (451P)(ionization chamber survey meter) and this showed the variation of calibration factor in five different years. This study also displayed the concept of radiation instrument calibration and necessity of every year calibration of them.In this project we used the five years calibration data for ionization chamber survey meter model Inspector (451P) to get that the values of Calibration Factor (CF) and Response (1/CF). The value deviation (Δ%) of CFs for four years of calibration in comparison of CF for the year 2007 are very high and the device under research is not good to use in field and reliable because the ionization chamber is very sensitive to humidity and must calibrate ayearor less, or during every two years and must maintain carefully to reduce the discarded effects to the measurements.

تحتاج أجهزة القياس الإشعاعي الى عملية معايرة والتي تفقد حساسيتها ومدى إستجابتها للقياس ومقدار كفائتها في الظروف المتغيرة بين فترة وأخرى وهذه الفترة تعتمد على طبيعة الاستخدام واﻟﻤﺠال المستخدمة فيه هذه الأجهزة. حيث تم إجراء دراسة المقارنة هذه لجهاز القياس الإشعاعي (451P)(حجرة التأين) وأظهرت الإختلاف لعامل المعايرة خلال خمس سنوات وكذلك بينت هذه الدراسة مفهوم معايرة جهاز القياس الإشعاعي وضرورة إجرائها. في هذا البحث تم إستخدام قراءات المعايرة لجهاز القياس الإشعاعي (451P)(حجرة التأين) وحصلنا على قيم عامل المعايرة والإستجابة. وإن نسبة الإنحراف(Δ%)عند مقارنة عوامل المعايرة للسنوات الأربعة (2010, 2011, 2012, 2013) مع عامل معايرة السنة (2007) نجدها مرتفعة جدا وبذلك فالجهاز غير موثوق به للعمل والقياس, ذلك بسبب ان كاشف حجرة التأين حساس جدا للرطوبة ويجب معايرته سنويا أو اقل أو خلال كل سنتين والمحافظة عليه للحد من الآثار السلبية المحتملة على القياسات.


Article
Calibration Factor for Conventional Linear Cephalometric Measurements

Authors: Ruba J. Mohammed --- Nazar Gh. Jameel --- Mohammad N Al-Mallah
Journal: Al-Rafidain Dental Journal مجلة الرافدين لطب الأسنان ISSN: 18121217 Year: 2018 Volume: 18 Issue: 34 Pages: 31-41
Publisher: Mosul University جامعة الموصل

Loading...
Loading...
Abstract

Aims: the aim of this study is to determine a calibration factor to eliminate the distortion in the linear cephalometric measurements. Materials and Methods; the study was performed on the 5 dry skulls, the first skull contained 12 radiopaque markers fixed at different plains, and radiographed by digital cephalometric x-ray machine. The X and Y axes of the shadow of each radiopaque marker used to estimate the calibration factor. Eight linear distances measured directly and radiographically on the conventional cephalographs of the 5 skulls to evaluate the detected calibration factor. Results; the results showed no-significant difference (p > 0.05) between the direct and calibrated radiographic measurement on the digital and conventional cephalographs. whereas significant difference was found between the conventional cephalometric linear measurements as compared with direct anatomical linear and the conventional cephalometric linear measurements with those measurements manipulated with the estimated calibration factor (p < 0.05). Conclusions; this study found that the conventional cephalometric linear measurements could be reliable as that of digital cephalometric linear measurements, if it's calibrated by the calibration factor (1.08) which is estimated by the present study.


Article
Radon Concentration in Al-Gazalia City, Baghdad, Iraq

Author: Milad J. Ali
Journal: Al-Nahrain Journal of Science مجلة النهرين للعلوم ISSN: (print)26635453,(online)26635461 Year: 2013 Volume: 16 Issue: 1 Pages: 121-128
Publisher: Al-Nahrain University جامعة النهرين

Loading...
Loading...
Abstract

Inhalation of indoor radon has been recognized as one of the health hazards. In the present work a set of indoor radon measurements was carried out, in different Iraqi houses in Al-Gazalia city/ Baghdad, built of the same type of building materials. Radon concentration determined by using time–integrated passive radon dosimeters containing CR-39 solid state nuclear track detector. Measurements were carried out from September to November 2011. The results show that, the radon concentrations varied from (38.7 to 200) Bq m-3. The mean values of radon concentrations in second floor hall and first floor of living rooms, kitchens and bathrooms, were: (46.56±9.13), (68.32±8.55), (128.03±21.65) and (168.92±33.52) Bq.m-3 respectively. This data shows that, bathrooms and kitchens have significantly higher radon concentrations and the second floor is lower radon concentration in all dwellings.

يعد غاز الرادون من الأخطار الصحية المنتشرة التي يُستهان بها. ففي كل يوم يتعرّض الكثيرون لمخاطره دون علمهم، وذلك من خلال المباني التي يعملون أو يسكنون فيها، حيث يتسرّب هذا الغاز عبر الشقوق الصغيرة الموجودة في أسس المباني. وان تقييم مستويات الرادون في البيوت والمباني العامة من الخطوات الهامة الأولى التي ينبغي اتخاذها. لذا في هذا البحث تم ايجاد تركيز غاز الرادون في منازل منفصله ومتعددة الاتجاهات في منطقة الغزاليه ببغداد العراق. حيث تم بناء هذه المنازل من نفس مواد البناء تقريبا. تم ايجاد تركيزغاز الرادون باستخدام كواشف الأثر النووي الصلبةCR-39 حيت تم تعريضها لمدة 60 يوما ابتداءا من شهر سبتمبر الى شهرنوفمبر 2011. من هذه الدراسة وجد ان معدلات تركيز غاز الرادون يتغير من (38.7-200) بيكرل في المتر المكعب. حيث وجد معدل تركيز غاز الرادون لكل من الطابق العلوي و غرفة المعيشه و المطبخ والحمام في الطابق الارضي لكل منزل من المنازل التي تـم فحصهـا، وكانـت النتائـج كالاتـي: (9.13±46.56)، (8.55±68.32)،(21.65±128.03)،(33.52±168.92) على التوالي بيكرل للمتر المكعب الواحد. من هذه النتائج استنتج ان اعلى تركيز لغاز الرادون في كل من الحمام والمطبخ للطابق الارضي وان اقل تركيز في الطابق العلوي لكل منزل.

Listing 1 - 3 of 3
Sort by
Narrow your search

Resource type

article (3)


Language

English (3)


Year
From To Submit

2018 (1)

2016 (1)

2013 (1)