research centers


Search results: Found 15

Listing 1 - 10 of 15 << page
of 2
>>
Sort by

Article
Syntheses, Characterization of a New Ligand(3-Hydrazino-N-isopropylidene-5-methyl-4H-1,2,4-trizole-4-amine) and its complex with (Fe(III), Co(III) and Ni(II))
تحضير وتشخيص ليكاند جديد (3-Hydrazino-N-isopropylidene-5-methyl-4H-1,2,4-trizole-4-amine) ومعقداته مع Fe(III), Co(III) and Ni(II)

Authors: Muntaha .Y. Hayal منتهى ياسين حيال --- Sajda .S. Affat ساجدة صبار عفات --- Ibrahim .A. Flifel ابراهيم عبود فليفل
Journal: JOURNAL OF THI-QAR SCIENCE مجلة علوم ذي قار ISSN: 19918690 Year: 2016 Volume: 5 Issue: 4 Pages: 65-71
Publisher: Thi-Qar University جامعة ذي قار

Loading...
Loading...
Abstract

The preparation of some, transition metal complexes ( Fe3+, Co3+ and Ni2+) with Novel ligand (3-Hydrazino-N-isopropylidene-5-methyl-4H-1,2,4-trizole-4-amine) .Prepared compounds diagnosed by spectrum ( Infrared(IR) , Nuclear magnetic resonance (1HNMR) , and Mass spectra (MS) ) and analytical techniques (Elemental analyses (CHN) , Conductivity measurements) .Each data explained in the tables (2,3 and 4) .We were able to determine the consistency through the infrared spectrum data show us that consistency is happening through amine and azomethine groups as illustrated in Figure (1) . This conclusion is confirmed by the diagnosis of a new absorption packages at (542, 534, 530) and (289, 270, 262) back to M-N and M-Cl respectively .Were not present in the spectrum ligand back to the central atom with two atoms of nitrogen consistency and the results were identical to what is practically expected. from all the outcome can be concluded the octahedral geometry of Fe3+and Co3+ complexes,, while Ni+2 complex were tetrahedral geometrics.

تم تحضير بعض معقدات العناصر الانتقالية ( Fe3+, Co3+ and Ni2+) مع اليكاند (3-Hydrazino-N-isopropylidene-5-methyl-4H-1,2,4-trizole-4-amine) . شخصت الصيغ التركيبية لليكاند ومعقداته باستخدام تقنية تحليل العناصر, التوصيل المولاري ، بالإضافة إلى استخدام أطياف الأشعة تحت الحمراء, أطياف الرنين النووي المغناطيسي وطيف الكتلة. وقد حصل التناسق من خلال مجموعتي الامين NH2 والازوميثين واكد هذا الاستنتاج يؤكد من خلال تشخيص حزم امتصاص جديدة ، عند (542,534,530) و( (289,270,262عائدة الى M-N وM-Cl على التوالي. لم تكن موجودة في طيف اليكاند عائدة إلى تناسق الذرة المركزية مع ذرتي النيتروجين وكانت النتائج مطابقة لما هو متوقع عمليا. ونعتقد بأن الهيئة الفراغية لأيون النيكل رباعي السطوع ببينما اظهر الحديد الثلاثي والكوبلت الثلاثي شكل ثماني السطوح.


Article
Using a Nonlinear Analysis Technique, Lyapunov Coefficient, and Conductance Study on the Understanding of DNA Nanowire asa Quasi-One-Dimensional Tight-Binding Chain

Authors: Shakir A. AL-Saidi --- Alaa Ayad Khedhair --- Mohammed Hallool
Journal: Journal of Education for Pure Science مجلة التربية للعلوم الصرفة ISSN: 20736592 Year: 2018 Volume: 8 Issue: 2 Pages: 261-272
Publisher: Thi-Qar University جامعة ذي قار

Loading...
Loading...
Abstract

Abstract:In this study, a nonlinear analysis technique, Lyapunov Coefficient, and the conductancemeasurements are used to understand the properties of DNA Nanowire as a Quasi-One-DimensionalTight-Binding Chain. Lyapunov Coefficient for five DNA sequences including [(G/C)24], [(A/T)24],[periodic)24], [(code periodic)24] and [(random)24] were studied. Its magnitude and behavior aswell as the conductance-temperature dependence are proved to be very useful for providingconsiderable information about DNA Nanowire system. In addition, the transmission of these fivesequences and temperature-dependent conductance (vary from 0K to 300K)has been investigated.


Article
Simulation of the Incremental Conductance Algorithm for Maximum Power Point Tracking of Photovoltaic System Based On Matlab

Author: Parween R.Kareem
Journal: DIYALA JOURNAL OF ENGINEERING SCIENCES مجلة ديالى للعلوم الهندسية ISSN: 19998716/26166909 Year: 2019 Volume: 12 Issue: 1 Pages: 34-43
Publisher: Diyala University جامعة ديالى

Loading...
Loading...
Abstract

Due to the urgent need to make maximum use of electrical power generated from the Photo-Voltaic System (PVS) solar panels, several techniques have been developed for this purpose. Maximum Power Point Tracking (MPPT) algorithm raises the efficiency of PVS’s. Simulation of the complete (PVS) possesses the ability of MPPT is present in this paper. The approved PVS consists of a PV array, DC-DC Boost Converter and MPPT algorithm using Incremental Conductance Method (INC). All parts of the system were simulated programmatically using MATLAB. The obtained Results showed the efficiency of the algorithm used to extract the maximum power regardless of changes in solar radiation and cell’s temperature.


Article
Evaluation of physical parameters in mitral valve stenosis by using Doppler Ultrasound
تقييم العوامل الفيزياوية لتضيق الصمام الأكليلي بأستخدام الدوبلر

Author: Numan Salman dawood م. نعمان سلمان داود
Journal: IRAQI JOURNALOF COMMUNITY MEDICINE المجلة العراقية لطب المجتمع ISSN: 16845382 Year: 2012 Volume: 25 Issue: 1 Pages: 56-60
Publisher: Al-Mustansyriah University الجامعة المستنصرية

Loading...
Loading...
Abstract

Background: Mitral valve stenosis is a condition in which the hearts mitral valve is narrowed (stenosis), This narrowing blocks the valve from opening properly obstructing blood flow through the heart and the rest of the body and this causes changes in physical parameters (resistance and conductance).Aim of the study: To assess the changes in the physical parameters in mitral valve stenosis disease in different gender and age by using Doppler ultrasound.Methods : The examination of patients at the Division of Echo - at the Iraqi Center for Heart Disease in Medical City for surgery specialist - Baghdad - Iraq, during(February2009 till November2010). The current study included fifty eight cases containing (27 males and 31 females) ages ranging between (16- 82) and is divided between 29 people from healthy people (I) which contain (13 males and 16 females) ages ranging between (16- 82) and a standard deviation of 22.6. Twenty nine of patients with mitral valve stenosis were divided into group (II) contains (6 males and 8 females) ages ranging between (28-76) and the standard deviation of 17.8, group (III) contains (5 males and 4 females) ages ranging between (40-71) and the standard deviation of 16.1 and group (IV) contain (3 male and 3 female) ages ranging between (56-72) and the standard deviation of 17.9. Studying changes developments in physical factors resulting from mitral valve stenosis and depending on these factors were calculated to change the resistance and conductivity and studying the relationship of the change in area and the change of physical factors.Results: The flow rate and area of mitral valve was significantly less in group IV than other groups, but pressure gradient, max velocity, pressure half time, max pressure were higher and more significantly in group IV. Resistance is significantly increases and it is higher in group IV compared with other groups. Conductance is higher in group I but more significant in group II.Conclusion: There is a strong correlation between the pressure half time and area of mitral valve. Resistance was significantly increased and it is higher in sever mitral stenosis. Conductance is high in mild mitral stenosis. The increase in mitral pressure gradient is frequently compensated by a decreased conductance. Age was highly influential but sex exerts less influence to change the physical parameters.Key word: Mitral valve stenosis, Area, Resistance, Conductance, Doppler US.

الخلفية : تضيق الصمام التاجي هو التضيق الحاصل في صمام القلب وهذا التضيق يمنع من فتح بشكل صحيح ويعرقل تدفق الدم عبر القلب وبقية الجسم وهذا يسبب تغيرات في العوامل الفيزياوية (المقاومة والحث). الأهداف: تقييم التغيير الحاصل في العوامل الفيزياوية الناتج من التضيق الحاصل في الصمام الأكليلي في الأعمار والأجناس المختلفة بواسطة استخدام جهاز الدوبلر . الطريقة: تم أجراء الفحص على المرضى المراجعين لشعبة الأيكو – في المركز العراقي لأمراض القلب في مدينة الطب للجراحة التخصصية – بغداد – العراق، خلال عام 2009 م. الدراسة الحالية تضمنت 58 حالة تحتوي على (27 من الذكور و31 من الإناث) بأعمار تتراوح بين (16 –82) ومقسمة بين 29 شخصا من الأصحاء (I) وتحتوي على (13 من الذكور و16من الإناث ( بأعمار تتراوح بين (16 – 82) وانحراف معياري 22.6 و 29 من المرضى الذين يعانون من التضيق في الصمام الأكليلي تم تقسيم المرضى الى مجاميع : المجموعة ((II وتحتوي على (6 من الذكور و8 من الإناث) بأعمار تتراوح بين (28 – 76) وبأنحراف معياري 17.8والمجموعة (III) تحتوي على (5 من الذكور و 4 من الإناث) بأعمار تتراوح بين (40 – 71 ) وبأنحراف معياري 16.1 والمجموعة (IV) وتحتوي على (3 من الذكور و3 من الإناث) بأعمار تتراوح بين (56 – 72) وبإنحراف معياري 17.9. تم دراسة التغييرات الحاصلة في العوامل الفيزياوية الناتجة من الإصابة بالتضيق الحاصل في الصمام الأكليلي وبالاعتماد على هذه العوامل تم حساب تغيير المقاومة والتوصيلية ودراسة علاقة تغيير مساحة الصمام بتغيير العوامل الفيزياوية للصمام.النتائج: وجد ان هناك علاقة بين تغيير مساحة الصمام وتغيير الضغط والعوامل الفيزياوية الأخرى حيث ان المعدل الحسابي للجريان في المجموعة (I) اكبر من المجموعة ((II ، والمجموعة ((III، والمجموعة (IV) وهذا التغيير ناتج من تغيير المساحة وقد صاحب هذه التغييرات المعتمدة إحصائياً تغيير في سرعة الجريان والمعدل الحسابي لمقاومة الأذين الأيسر للمجموعة (IV) اكبر من المجموعة (I) وهذا ناتج من العلاقة العكسية بين تغيير المساحة والمقاومة بينما تسلك التوصيلية سلوك مغاير لسلوك المقاومة وقد صاحب هذا تغيير في انحدار الجهد . وقد وجدت الدراسة ان عامل العمر ذو تأثير واضح ولكن الجنس ذو ثأثير ضعيف على تغيير هذه العوامل الفيزياوية.الاستنتاجات : هنالك علاقة بين معدل الضغط والمساحة .التضييق الحاصل في الصمام الإكليلي له تأثير مباشر على مقاومة الجريان والتوصيلية وهذا ناتج من تغيير مساحة الصمام . وزيادة انحدار الضغط يسبب نقصان في التوصيلية .


Article
Asymmetric Double Quantum Dot Structure as Nanoscale Diode

Authors: Shakir A. A. AL-Saidi --- Alaa Ayad Khedhair Al-mebir
Journal: Univesity of Thi-Qar Journal مجلة جامعة ذي قار العلمية ISSN: 66291818 Year: 2018 Volume: 13 Issue: 4 Pages: 1-17
Publisher: Thi-Qar University جامعة ذي قار

Loading...
Loading...
Abstract

In this studying, a nanoscale diode was proposing by using asymmetric double quantum dot structure attached to metallic electrodes. An asymmetric double quantum dot (ADQD) is used as a diode for rectification. Tight-binding model was adopting to describe our specimen, and our results depend upon steady-state forming to show charge transport. The theoretical computations for current and conductance as a function of the time, that encouraging common traits of the rectifications, were presented. The analysis may be helpful in fabricating nanoscale electronic devices


Article
Substituent Effect on the Association Phenomenon of an Aqueous Solution of Benzylidene Substituted Aniline at Different Temperatures
دراسة تأثير المعوضات على ظاهرة التجمع الأيوني للمحاليل المائية للبنزيلدين أنيلين المعوض عند درجات حرارية مختلفة

Authors: Mohammed A. Al-Iraqi محمد احمد العراقي --- Yaser O. Al-Allaf ياسر عمر العلاف --- Kawther H. Al-Naimi كوثر حسين النعيمي
Journal: Rafidain journal of science مجلة علوم الرافدين ISSN: 16089391 Year: 2013 Volume: 24 Issue: 3E Pages: 51-65
Publisher: Mosul University جامعة الموصل

Loading...
Loading...
Abstract

Conductivity parameters of an aqueous solution of benzylidene substituted anilines (I-IV) have been determined at five different temperatures in the range of 283.15-318.15 ºK, through accurate conductance measurements. The obtained data were analyzed in accordance to Lee-Wheaton equation taking into account the activity of the electrolyte in the solution. The conductance measurement results were used to determine the association constants (KA) of ion-pairs, the mean distance between ions in solution, in addition to the molar conductance at infinite dilution (Λo¬) for the free ion in the solution. The dependence of (KA) values on the temperature has been examined by plotting Log KA against the reciprocal values of temperature (1/T), which showed linear relationship, where (KA) values decrease with increasing temperature. Moreover, the enthalpy (ΔH), Gibbs free energy (ΔG) and the entropy (ΔS) have been derived from this linear relationship.

تم تقدير دوال التوصيلية للمحاليل المائية للبنزيلدين أنيلين المعوض(I-IV) عند خمس درجات حرارية في المدى (383.15-318.15 ºK) من خلال قياسات التوصيلية الدقيقة. تم تحليل النتائج باستخدام معادلة لي-ويتون مع الأخذ بنظر الإعتبار فعالية الإلكتروليت في المحلول. أستخدمت قياسات التوصيلية في تقدير ثابت التجمع الأيوني (KA) للمزدوج الأيوني، ومعدل المسافة بين الأيونات في المحلول فضلا عن حساب التوصيلية المولارية عند التخفيف النهائي (Λo) للأيون الحر في المحلول. درس تأثير درجة الحرارة على قيم ثابت التجمع الأيوني من خلال رسم العلاقة بين Log KA ضد مقلوب درجة الحرارة (1/T) والتي أعطت علاقة خطية، إذ انخفضت قيمة (KA) بزيادة درجة الحرارة، فضلا عن ذلك حسبت قيم المحتوى الحراري (ΔH) والطاقة الحرة (ΔG) والعشوائية (ΔS) من العلاقة الخطية هذه.


Article
Parametric Simulation on Enhancement of the Regenerative Gas Turbine Performance by Effect of Inlet Air Cooling System and Steam Injection

Author: Aadel Abdulrazzaq Alkumait
Journal: Tikrit Journal of Engineering Sciences مجلة تكريت للعلوم الهندسية ISSN: 1813162X 23127589 Year: 2015 Volume: 22 Issue: 1 Pages: 38-44
Publisher: Tikrit University جامعة تكريت

Loading...
Loading...
Abstract

Iraq being one of the developing countries of the world considers energy efficiency and the impact of its generation on the environment an imperative process in improvement of its power generation policies. Iraq bearing high temperatures all year long results in reduction of air density, therefore, Inlet air Cooling and Steam Injection Gas Turbines are a striking addition to the regenerative gas turbines. Regenerating Gas turbines tend to have a high back work ratio and a high exhaust temperature, thus, it leads to a low efficiency in power generation in hotter climate. Moreover, STIG and IAC through fog cooling have known to be the best retrofitting methods available in the industry which improve the efficiency of generation from 30.5 to 43% and increase the power output from 22MW to 33.5MW as the outcomes of computer simulations reveal. Additionally, this happens without bringing about much extensive change to original features of the power generation cycle. Furthermore, STIG and spray coolers have also resulted in power boosting and exceeding generation efficiency of gas turbine power plant.


Article
Internal Convective Heat Transfer Effect on Iraqi Building Construction Cooling Load
تأثير انتقال الحرارة الداخلي بالحمل على حمل التبريد لأبنية عراقية التركيب الإنشائي

Authors: Khalid Ahmed Joudi خالد أحمد جودي --- Ali Naser Hussien علي ناصر حسين
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2015 Volume: 21 Issue: 9 Pages: 119-134
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

This work involves the calculation of the cooling load in Iraqi building constructions taking in account the effect of the convective heat transfer inside the buildings. ASHRAE assumptions are compared with the Fisher and Pedersen model of estimation of internal convective heat transfer coefficient when the high rate of ventilation from ceiling inlet configuration is used. Theoretical calculation of cooling load using the Radiant Time Series Method (RTSM) is implemented on the actual tested spaces. Also the theoretical calculated cooling loads are experimentally compared by measuring the cooling load in these tested spaces. The comparison appears that using the modified Fisher and Pedersen model when large ventilation rate is used; modify the results accuracy to about 10%.

العمل الحالي يتضمن حساب حمل التبريد في تراكيب البناء العراقي مع الأخذ في الاعتبار تأثير انتقال الحرارة بالحمل داخل البناية. فرضية اشري قورنت مع طريقة فيشر وبدرسن في تخمين معامل انتقال الحرارة الداخلي عند استخدام معدلات عالية للتهوية لحالة تجهيز الهواء من السقف. تم احتساب حمل التبريد نظريا باستخدام طريقة السلسلة الزمنية للإشعاع RTSM)) لفضاءات اختبار حقيقية. كذلك فان حمل التبريد المحسوب نظريا تم مقارنته عمليا بقياس حمل التبريد في هذه الفضاءات. المقارنة أظهرت ان استخدام طريقة فيشر وبدرسن المعدلة لمعدلات كبيرة من التهوية, يحسن دقة النتائج لحدود تصل ل 10%.


Article
Conductance-Voltage Characteristics of Single Molecule Junction: in Resonant Tunneling Regime
خصائص التوصيلية-الفولتية لوصلة احادية الجزيئة : في نهج الرنين النفقي

Authors: Fouad Nimr Ajeel --- Jenan Majeed AL-Mukh --- Lafy Faraj Al-Badry
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2015 Volume: 33 Issue: 5 Part (B) Scientific Pages: 799-812
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

Electronic transport characteristics through a single molecule junction are investigated by using the Keldysh non equilibrium Green function (NEGF) model. The model consists of a molecular bridge (represented by a molecular orbital) attached with two free electron reservoirs (represents two metallic leads) and it is coupled with a vibrational degree of freedom (represents a molecular vibrational mode). The behavior of the electronic transfer through the molecular junction becomes more clearly visible by studying of the conductance-voltage characteristics. The numerical calculations are done based on this model to study the changes in conductance behavior through a single molecule junction in the resonant tunneling regime. According to our results, the conductance-voltage characteristics are influenced by (I) the electron-vibration interaction, (II) the molecular bridge-leads coupling strength, (III) the junction temperature, and (IV) the molecular vibrational mode energy. We conclude that the previous parameters have a significant role in determination of the electron conduction through the single-molecule junctions. Especially, the conductance is very sensitive to the molecular bridge-leads coupling strength and the junction temperature. These features provide important information about the study of the electronic transport phenomena in molecular junctions.

تم فحص خصائص النقل الإلكتروني عبر وصلة احادية-الجزيئة باستخدام نموذج دالة گرين غير المتزنة (NEGF). حيث يتألف هذا النموذج من الجسر الجزيئي (تم تمثيله بالمدار الجزيئي) المرتبط بخزاني الإلكترون الحر (تمثلان قطبين معدنيين) والمرتبط كذلك بدرجة الحرية الاهتزازية (والذي تم تمثيله بالنمط الاهتزازي الجزيئي). ان سلوك النقل الالكتروني من خلال الوصلة الجزيئية يصبح أكثر وضوحاً بدراسة خصائص التوصيلية-الفولتية. انجزت الحسابات العددية استناداً على هذا النموذج لدراسة التغيرات في سلوك التوصيلية عبر الوصلة احادية-الجزيئة في نهج النفق الرنيني. ووفقاً لنتائجنا، فأن خصائص التوصيلية-الفولتية تتأثر بـ : (I) تفاعل الكترون-اهتزاز، (II) قوة اقتران المدار الجزيئي-الاقطاب، (III) درجة حرارة الوصلة، و (IV) طاقة النمط الاهتزازي الجزيئي. واستنتجنا بان المعاملات السابقة لها دور هام في تحديد توصيل الإلكترون عبر وصلة احادية-الجزيئة. وبالخصوص تكون التوصيلية حساسة جداً لقوة اقتران المدار الجزيئي-الاقطاب ودرجة حرارة الوصلة. هذه السمات توفر معلومات هامة حول دراسة ظواهر النقل الإلكتروني في الوصلات الجزيئية.


Article
Selection of Best House Construction Materials for Roofs and Walls Regarding Cost, Weight, thermal Insulation and Mechanical Properties
أختيار أفضل مواد أنشائية للتسقيف والجدران في أنشاء وحدات سكنية من حيث (الكلفة ، الوزن ، العزل الحراري والخواص الميكانيكية)

Authors: Amer Mohamed Ibrahim --- Ahmed Abdullah Mansor --- Jaleel Ibrahim Kaduri
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2017 Volume: 35 Issue: Special Issue 1 Pages: 248-260
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

Research includes the study of the effect of using different local and low cost construction materials in thecreation of traditional buildings and the effect of using these materials in terms of cost, loads over the soil,and the thermal insulation.The research plan on the construct of three rooms has (4 × 5) m dimensions and a 3 m height from differentmaterials. And adopt its findings on the reality of the buildings in Iraq. It has been concluding that the costsof stiroboor and thermiston slab were less than the cost of a rigid slab by 43.4% and 21.3% respectively.And the weight of stiroboor and thermiston slabs were less than weight of rigid slab by 33.8% and 6.6%,respectively, and the deflection of stiroboor and thermiston slabs were higher than sold slab by 20% and0.5% respectively.The thermal conductivity coefficient, and conductance of stiroboor and thermiston slab was less than therigid slab by 41% and 20.5% respectively, and that the thermal conductivity coefficient, and conductanceof brick and thermiston walls were less than the hollow concrete block walls by 25% and 66.7%,respectively. The thermal resistances of stiroboor and thermiston slab were higher than the sold slab by41% and 20.5%, and that the coefficient of thermal resistance of the brick and thermiston walls was higherthan hollow concrete block walls by 25% and 66.7%.The energy that needed for stiroboor slab and brick walls room during the day and night were lower by35.1% and 11.4%, respectively, and for thermiston room by 64% and 54.1%, respectively, compared to therigid slab and hollow concrete walls room.

يتضمن البحث دراسة تاثير أستخدام مواد انشائية محلية مختلفة واطئة الكلفة في أنشاء الابنية التقليدية من حيث الكلفة، الاحمالالمسلطة على التربة ، ومدى العزل الحراري.3(متر وبارتفاع 5متر من مواد مختلفة كعينة يمكن تطبيقها × تقوم خطة البحث على أنشاء ثلاث نماذج من الغرف بابعاد ) 4وأعتماد نتائجها على واقع الابنية في العراق. فقد تبين ان كلفة انشاء بلاطتي الفلين والثرمستون اقل من كلفة أنشاء البلاطة الصلدةبنسبة 45.4 % و 71.5 % على التوالي. وتم التوصل الى ان وزن بلاطتي الفلين والثرمستون اقل من وزن البلاطة الصلدة بنسبة%55.3 و بنسبة 6.6 % على التوالي ، اضافة الى ان قيم الهطول الاني لبلاطتي الفلين والثرمستون كانت اعلى من القيم العمليةللبلاطة الصلدة بنسبة 71 % و 1.3 % على التوالي.% وتم التوصل الى ان معامل التوصيل الحراري والموصلية لبلاطتي الفلين والثرمستون اقل من البلاطة الصلدة بنسبة 41و 71.3 % على التوالي ،وان معامل التوصيل الحراري والموصلية لجدران من الطابوق والثرمستون اقل من جدران البلوكالخرسانية المجوفة بنسبة 73 % و 66.2 % على التوالي. اما الممانعة الحرارية لبلاطتي الفلين والثرمستون فكانت اعلى منالبلاطة الصلدة بنسبة 41 % و 71.3 % ، وان معامل الممانعة الحرارية لجدران الطابوق والثرمستون كانت اعلى من جدران. % البلوك الخرسانية المجوفة بنسبة 73 % و 66.2 اما بخصوص الطاقة التي تحتاجها الغرفة المشيدة من بلاطة الفلين وجدرانها من الطابوق خلال النهار والليل فكانت اقلبنسبة 53.1 % و 11.4 % على التوالي و للغرفة المشيدة من الثرمستون بنسبة 64 % و 34.1 % على التوالي مقارنة بالغرفةالمشيدة من البلاطة الصلدة وجدرانها من البلوك

Listing 1 - 10 of 15 << page
of 2
>>
Sort by
Narrow your search

Resource type

article (15)


Language

English (14)

Arabic (1)


Year
From To Submit

2019 (2)

2018 (2)

2017 (3)

2016 (2)

2015 (3)

More...