research centers


Search results: Found 2

Listing 1 - 2 of 2
Sort by

Article
Experimental and Theoretical Investigation of Propane/Butane and Propane/Isobutane Mixtures as an Alternative to R134a in a Domestic Refrigerator
تحقيق عملي ونظري في خليط بروبانبيوتان وخليط بروبانايزوبيوتان كبديل عن R134a في الثلاجة المنزلية

Authors: Wahid S. Mohammad --- Assad Oda Jassim
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2014 Volume: 32 Issue: 5 Part (A) Engineering Pages: 1266-1286
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

In the present work, theoretical and experimental investigation have been carried out with two hydrocarbon refrigerant mixtures as a possible alternatives to R134a. Theoretical performance of an ideal vapor compression refrigeration cycle using R290/R600 and R290/R600a was studied and the results were compared with those of R134a. The performance of the hydrocarbon mixtures of R290/R600 and R290/R600a were experimentally investigated as a drop-in alternatives to replace R134a in 297 liter domestic refrigerator designed to work with R134a. The results showed a lower freezer air temperature, lower cabinet air temperature, lower discharge temperature, higher coefficient of performance, lower pressure ratio and lower electrical power by about 3.2°C, 2.3°C, 3.1°C, 4.9%, 7% and 9.4%, respectively, for R290/R600 (60/40) % with 60g mass charge and 50% longer capillary tube compared with those of R134a with 120g mass charge.

في العمل الحالي تم اجراء تحقيق نظري وعملي لخليطين من موائع التثليج الهيدروكربونية كبديلين محتملين لمائع التثليج R134a. تم دراسة الأداء النظري لدورة التثليج الانضغاطية المثالية باستخدام بروبانبيوتان و بروبانايزوبيوتان وقورنت النتائج مع نتائج مائع التثليج .R134a ان اداء الخليطين الهيدروكربونين المكونان من بروبانبيوتان و بروبانايزوبيوتان تم التحقيق به عمليا كبديلين لمائع التثليج R134a في ثلاجة منزلية سعة 297 لتر صممت للعمل على مائع التثليج R134a. اظهرت النتائج العملية ان بروبانبيوتان (بنسبة كتلية للبروبان مقدارها 60% وشحنة 60g للخليط50% زيادة في طول الانبوب الشعري) له درجة حرارة حجرة تجميد اوطأ ودرجة حرارة حجرة تبريد اوطأ ودرجة حرارة اوطأ لمائع التثليج الخارج من الضاغط ومعامل اداء اعلى ونسبة انضغاط اوطأ وطاقة كهربائية اقل بمقدار 3.2°C و 2.3°C و 3.1°C 4.9% و 7% و 9.4% على التوالي, مقارنة مع تلك عندما يكون R134a مستخدما كمائع تثليج بشحنة 120غم.


Article
Numerical and experimental investigation on the performance of the capillary tube using R-134a and R-600a
التحليل العملي والعددي على الجريان الاديباتي لموائع التثليج البديلة في الانبوب الشعري

Authors: Qasim Saleh Mehdi قاسم صالح مهدي --- Baydaa Jaber Nabhan بيداء جابر نبهان
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2012 Volume: 18 Issue: 12 Pages: 1403-1420
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

In this paper, isobutane (R-600a) is used as a suitable substitute for (R-134a) when changing the length of capillary tube. And the experimental data on capillary tube are obtained under different conditions such as (subcooling and ambient temperatures) on domestic refrigerator (9ft3 size), this data shows that (R-600a) a suitable substitute for (R134a) .The test presented a model for a steady state, two-phase flow in capillary tube for vapour compression system .The numerical model depends on conservation equations (mass, energy and momentum) as wall as the equation of state for refrigerant. The solution methodology was implemented by using finite difference techniques. The system results indicate that it is possible to change the refrigeration system using (R-134a) by shorter capillary tube length about (28.6%) when using (R-600a) .The theoretical results for different variables such as(subcooling and ambient temperatures) showed a good agreement with the "ASHRAE" tables and experimental results.

تم في هذا البحث استخدام مائع التثليج R-600a كبديل لمائع التثليج R-134aمن خلال تغير طول الأنبوب الشعري ,حيث تم الحصول على بيانات عملية لأنبوب شعري تحت مختلف الظروف مثل (درجة التبريد الإضافي ودرجة حرارة المحيط ) لثلاجة منزلية سعة (9 قدم3) والتي أوضحت بان R-600a هو مائع التثليج المناسب ل (R-134a). قدم هذا الاختبار الحالة المستقرة للجريان الثنائي للمائع داخل الأنبوب الشعري في منظومة التثليج الانضغاطية . اعتمدت النمذجة العددية على معادلات حفظ (الكتلة , الطاقة , الزخم ) بالإضافة إلى معادلة الحالة للمائع . منهجية الحل نفذت باستخدام تقنية الفروق المحددة في حل المعادلات . ونتائج المنظومة تشير إلى إمكانية تغير منظومة التثليج المستخدمة R-134a بواسطة تقصير طول الأنبوب الشعري بحوالي (28.6%) عندما نستخدم R-600a.النتائج النظرية لمتغيرات مختلفة مثل (درجة التبريد الإضافي ودرجة حرارة المحيط ) تشير إلى تطابق جيد مع جداول ASHRAE"" وكذلك مع النتائج العملية لهذا البحث.