research centers


Search results: Found 2

Listing 1 - 2 of 2
Sort by

Article
Separation of oil from O/W emulsion by electroflotation technique

Authors: Ali Jassim Mohammed Al-Gurany --- Ahmed A. Mohammed
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2010 Volume: 16 Issue: 3 Pages: 5503 -5515
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

Dilute emulsified oil in water (50-500 ppm) was removed by electrocoagulatin and electroflotation process. Effects of various parameters such as current density, initial pH, sodium chloride concentration, different electrodes material, gap, temperature, electrodes surface area, and treatment time on the removal efficiency were studied in batch and continuous mode.It was found that the higher removal efficiency (99%) achieved at pH of 7.5 for Al/Al electrodes while for iron electrodes at pH 8 in the batch mode. The removal efficiency increased and the treatment time decreased with increasing the current density and decreasing the gap distance between electrodes. The removal efficiency was (99%) at 10 min for Al/Al electrodes, (98.6%) at 12 min for Al/St.St. electrodes, and (97.4%) at 12 min for Fe/St.St. electrodes. The present results showed that the best temperature was 60ºC .The best concentration of sodium chloride was found to be (400 ppm) when the oil concentration was (500 ppm). Also it was found that a vertical Al/Al electrode was the best type with an electrical energy consuming (3.36 kWh/m3). In the continuous experiments, the removal efficiency enhanced with increasing flow rate. A multiple linear regression model was used in order to relate experimental data to a statistical model with a correlation coefficient of (0.909) and variance (0.827).

الزيت المستحلب في الماء (50-500 ppm) فصل بطريقة التطويف الكهربائي . تم دراسة تأثير عدة متغيرات مثل كثافة التيار,الدالة الحامضية ,تركيز كلوريد الصوديوم,نوعية الاقطاب ,درجة الحرارة,المساحة السطحية ,المسافة بين الاقطاب ,وزمن المعالجة على كفاءة ازلة الزيت وبأسلوب الوجبة. ومن التجارب وجد ان اعلى كفاءة (99%) وبدالة حامضية (pH=7.5) لاقطاب Al/Al اما بالنسبة لاقطاب Fe/St.St عندما تكون الدالة الحامضية هي (pH=8). وقد تبين ان كفاءة الازالة تزداد وزمن المعاجة يقل بزيادة كثافة التيار الكهربائي في حين عند زيادة المسافة بين الاقطاب يؤدي الى نقصان كفاءة الازلة مع زيادة زمن المعالجة. ومن خلال النتائج المختبرية الكفاءة المستحصلة (99%) بزمن (10 min) لاقطاب Al/Al وكفاءة (98.6%) وزمن (12 min) بالنسبة لاقطاب Al/St.St.واما اقطاب Fe/St.St.تكون الكفاءة (97.4%) وزمن (12 min).أفضل درجة حرارة هي (60 ºC) وأفضل تركيز لملح كلوريد الصوديوم هو(400 ppm) .ونستنتج من التجارب المختبرية ان اقطاب Al/Al العمودية هي الافضل باسنهلاك للطاقة الكهربائية بمقدار (3.36 kWh/m3).وجد ان كفاءة الازالة تتحسن مع زيادة الجريان.من خلال احتساب الانحدار اللاخطي المتعدد للنتائج المختبرية تم ايجاد معادلة تربط كافة المتغيرات المدروسة وبمعامل تصحيح (90.9%) وتباين (82.7%).


Article
Removal of Manganese Ions (Mn2+) from a Simulated Wastewater by Electrocoagulation/ Electroflotation Technologies with Stainless Steel Mesh Electrodes: Process Optimization Based on Taguchi Approach
إزالة أيونات المنغنيز (Mn2+) من مياه الصرف المصنعة بواسطة تقنيات التخثر/ التعويم الكهربائية باستخدام أقطاب الفولاذ المشبكية: أيجاد الظروف المثلى بواسطة طريقة تاكوشي

Author: Rasha H. Salman
Journal: Iraqi Journal of Chemical and Petroleum Engineering المجلة العراقية للهندسة الكيمياوية وهندسة النفط ISSN: 19974884/E26180707 Year: 2019 Volume: 20 Issue: 1 Pages: 39-48
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

This study depicts the removal of Manganese ions (Mn2+) from simulated wastewater by combined electrocoagulation/ electroflotation technologies. The effects of initial Mn concentration, current density (C.D.), electrolysis time, and different mesh numbers of stainless steel screen electrodes were investigated in a batch cell by adopting Taguchi experimental design to explore the optimum conditions for maximum removal efficiency of Mn. The results of multiple regression and signal to noise ratio (S/N) showed that the optimum conditions were Mn initial concentration of 100 ppm, C.D. of 4 mA/cm2, time of 120 min, and mesh no. of 30 (wire/inch). Also, the relative significance of each factor was attained by the analysis of variance (ANOVA) which indicates that the percentage of contribution followed the order: time (47.42%), C.D. (37.13%), Mesh number (5.73%), and Mn initial Conc. (0.05%). The electrolysis time and C.D. were the most effective operating parameters and mesh no. had a fair influence on Mn removal efficiency, while the initial conc. of Mn. had no significant effect in the studied ranges of control factors. Regression analysis (R2= 90.16%) showed an acceptable agreement between the experimental and the predicted values, and confirmation test results revealed that the removal efficiency of Mn at optimum conditions was higher than 99%.

في هذه الدراسة ، تم التحقق في كفاءة إزالة أيونات المنغنيز من مياه الصرف الصحي بواسطة تقنيات التخثر/ التعويم الكهربائية. تمت دراسة تأثير تركيز المنغنيز الأبتدائي ، كثافة التيار (C.D.) ، زمن التحليل الكهربائي ، وحجم المشبك لأقطاب الفولاذ المشبكية في خلية دفعية من خلال تطبيق تصميم تاكوشي لايجاد الظروف المثلى لأقصى كفاءة إزالة للمنغنيز. أظهرت نتائج (S/N) أن الظروف المثلى كانت, التركيزالأبتدائي للمنغنيز هو 100جزء في المليون ، C.D.هو 4 مللي أمبير / سم 2 ، ووقت 120 دقيقة ، وشبكة ذات حجم 30 واير/أنج. أيضا ، تم بحث الأهمية النسبية لكل عامل عن طريق تحليل التباين (ANOVA) الذي يشير إلى أن النسبة المئوية للمساهمة تتبع الترتيب: الوقت (%47.42) ، C.D. (% 37.13) ، حجم المشبك (%5.73) ، و التركيزالأبتدائي للمنغنيز هو (%0.05). وقت التحليل الكهربائي و C.D. كانت هي العوامل الأكثر تأثيراً وحجم الشبكة له تأثير مقبول على كفاءة إزالة أيونات المنغنيز ، في حين أن التركيزالأبتدائي للمنغنيز لم يكن له تأثير مذكور في المدى المدروس. أظهر تحليل الانحدار (R2% = 90.16) اتفاقا جيدا بين القيم التجريبية والقيم المتوقعة ، وأظهرت النتائج تأكيد أن كفاءة إزالة المنغنيز في الظروف المثلى كانت أعلى من %99.

Listing 1 - 2 of 2
Sort by
Narrow your search

Resource type

article (2)


Language

English (2)


Year
From To Submit

2019 (1)

2010 (1)