Strength Prediction of Polypropylene Fiber Reinforced Concrete

Authors: Najaat H. Ne'ma --- Abdulnasser M. Abbas --- Rana A. Mtasher
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2011 Volume: 29 Issue: 2 Pages: 305-311
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

The main purpose of this investigation is to study the effects ofpolypropylene fiber on the compressive and flexural strength of normal weightconcrete. Four mixes used polypropylene fiber weight with 0.4, 0.8, 1.0 and 1.5%of cement content. To provide a basis for comparison, reference specimens werecast without polypropylene fiber. The test results showed that the increase ofmechanical properties (compressive and flexural strength) resulting from added ofpolypropylene fiber was relatively high. The increase was about 64 percent forcompressive strength, while, in flexural strength was about 55.5 percent.


Article
The Effect of Elevated Temperature of Compressive Strength of Steel Fiber Concrete

Author: Osama M. Ghazi
Journal: Journal of University of Babylon مجلة جامعة بابل ISSN: 19920652 23128135 Year: 2013 Volume: 21 Issue: 3 Pages: 1006-1012
Publisher: Babylon University جامعة بابل

Loading...
Loading...
Abstract

This study presents the benefit gained from using steel fiber reinforcement on concrete mixture. The effect of fire on compressive strength is investigated. Two different tests, one of them is the non destructive test which is the ultrasonic pulse velocity (UPV) test and the other is the destructive compression test, are carried out using (10cm) cubes. Forty-eight cubes (half of them are with steel fiber reinforcement of fiber/concrete ratio of (0.01) by volume and the remaining cubes are without fiber reinforcement) are heated to temperature levels of (100,200,300,400,500,600 and 700°C). Then after that specimens are air cooled and (UPV) test is done, the specimens are destructively tested. The results indicated that the addition of steel fiber increases the compressive strength at all tested heating levels with a maximum percentage increase of (56.9%) at a temperature level of (500°C), in spite of that they have the same behavior but the residual compressive strength decreases with the addition of steel fiber for the tested heating levels lower than (400°C) and increases for the heating levels above this degree

الدراسة الحالية تسلط الضوء على الفائدة الحاصلة من تسليح الألياف الفولاذية في تكنولوجيا الخرسانة حيث بحث تاثير الحرارة على مقاومة انضغاطها.اجري نوعان من الفحص احدهما لااتلافي وهو فحص سرعة الأمواج فوق الصوتية (UPV)والأخر إتلافي باستعمال نماذج مكعبة بطول ضلع(10سم).تم تسخين(48) نموذج (نصفها مقواة بألياف الفولاذ بنسبة حجمية للالياف الفولاذية إلى الخرسانة مقدارها(0.01)والنماذج الأخرى المتبقية غير مقواة) إلى مستويات من درجات الحرارة هي(100و200و300و400و500و600و700)درجة سيليزية.فحصت النماذج لا اتلافيا بعد تبريدها بتعريضها للهواء ثم فحصت اتلافيا.بينت النتائج ان إضافة الألياف الفولاذية يزيد من مقاومة الانضغاط في كل مستويات درجات الحرارة التي قيست فيها باعلى نسبة زيادة مقدارها (56.9%) من تلك غير المقواة عند درجة حرارة (500) درجة سيليزية بالرغم من ان لهما نفس السلوك ولكن نسبة ما تبقى من المقاومة بعد الحرق من المقاومة الاصلية يقل باضافة الالياف الفولاذية عند كل مستويات درجات الحرارة الأقل من (400)درجة سيليزية ولكنها تزداد بعد تلك الدرجة.


Article
Effect of Steel Fiber and Silica Fume on Hardened Concrete Compressive and Flexural strength
تأثير ألياف وغبار السليكا على مقاومه الانضغاط والانحناء للخرسانة المتصلبة

Author: Lina Abudel Salam لينا عبد السلام
Journal: Journal of Engineering and Sustainable Development مجلة الهندسة والتنمية المستدامة ISSN: 25200917 Year: 2015 Volume: 19 Issue: 1 Pages: 68-86
Publisher: Al-Mustansyriah University الجامعة المستنصرية

Loading...
Loading...
Abstract

Fiber reinforced concrete (FRC) may be defined as a composite materials made with Portland cement, aggregate, and incorporating discrete discontinuous fibers and silica fume. In this paper an attempt is made at 300°C to present the results of an experimental investigation carried out on (FRC). While Fiber content was used as (0%, 0.5% and1%) by weight of mix and silica fume was used as (0%, 5% and 10%) by weight of cement. Effect of the addition of silica fume and steel fiber on the various strengths of concrete was studied. The strengths considered for investigation are compressive strength and flexural strength. Cubes of size (150) mm for compressive strength; beams of size (100 mm x 100 mm x 500 mm) for flexural strength, were used as specimens. All the specimens were water cured for 28 days and tested subsequently. The compressive strength decreases by about (18%, 18.1% , 20% ) for (0% steel fiber) at 300°C with no silica fume, 5% and 10% silica fume respectively and the compressive strength decreases by about (16%, 20 % , 24% ) for (0.5% steel fiber) at 300°C with no silica fume, 5% and 10% silica fume respectively while the compressive strength decreases by about (15%, 15.5%, 16% ) for (1% steel fiber) at 300°C with no silica fume, 5% and 10% silica fume respectively. The flexure strength decreases by about (40.3%, 39.9% , 41% ) for (0% steel fiber) at 300°C with no silica fume, 5% and 10% silica fume respectively and the flexure strength decreases by about (38.5%, 38.0% , 38.1%) for (0.5% steel fiber) at 300°C with no silica fume, 5% and 10% silica fume respectively, while flexure strength decreases by about (35.8%, 36%, 37.07% ) for (1% steel fiber) at 300°C at 300°C with no silica fume, 5% and 10% silica fume respectively. All the above results are compared with cubes and prisms tested at room temperature (25 °C).

تعرف الخرسانة المقواة بالياف الفايبر على انها خرسانة مركبة مكونة من مزيج من السمنت, الحصى, الرمل, الياف الفايبر وغبار السيليكا . يهدف هذا البحث الى تقييم اداء الخرسانة المقواة بالياف الفايبر وغبار السيليكا من حيث مقاومة الانضغاط والانثناء للخرسانة في درجة حرارة 300°م .لاجراء هذه التجربة استخدم مكعب ذو ابعاد ( 150×150) ملم وموشور ذو ابعاد (100×100×500) ملم. وجدت النتائج ان مقاومة الانضغاط للخرسانة قلت بحدود (18٪,18,1٪,20٪) في حالة(0٪ الياف الفايبر) في درجة حرارة 300°م وغبار السيليكا( 0٪, 5٪, 10٪) على التوالي , قلت مقاومة الانضغاط بحدود (16٪, 20٪, 24٪) في حالة (0,5٪ الياف الفايبر) في درجة حرارة 300°م وغبار السيليكا ( 0٪, 5٪, 10٪) و قلت مقاومة الانضغاط بحدود ( 15٪, 15,5٪,16٪) في حالة (1٪ الياف الفايبر) في درجة حرارة 300°م وغبار السيليكا ( 0٪, 5٪, 10٪). كما وجد ان مقاومة الانثناء للخرسانة قلت بحدود (40,3٪,39,9٪,41٪) في حالة (0٪ الياف الفايبر) في درجة حرارة 300°م وغبار السيليكا( 0٪, 5٪, 10٪) على التوالي , قلت مقاومة الانثناء بحدود (38,5٪, 38٪, 38,1٪) في حالة (0,5٪ الياف الفايبر) في درجة حرارة 300°م وغبار السيليكا ( 0٪, 5٪, 10٪) و قلت مقاومة الانثناء بحدود ( 35,8٪, 36٪,37,07٪) في حالة (1٪ الياف الفايبر) في درجة حرارة 300°م وغبار السيليكا ( 0٪, 5٪, 10٪). علما ان جميع النتائج قد تم مقارنتها مع مكعبات ومواشير بدرجة حرارة (25°).


Article
An Experimental Study on the Shear Strength of High-performance Reinforced Concrete Deep Beams without Stirrups

Author: Sinan Abdulhkaleq Yaseen
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2016 Volume: 34 Issue: 11 Part (A) Engineering Pages: 2123-2139
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

High-performance fiber-reinforced concrete is a new class of concrete that has been developed in recent decades. It exhibits enhanced properties such as high compressive strength and improved tensile strength. Three types of concrete with different compressive strengths, namely, normal-strength concrete, high-strength concrete, and high-performance concrete, were used in this study. The experimental program included casting and testing sixteen reinforced concrete deep beams without stirrups to study the shear strength and behavior of these beams under two-point loading. The variables considered were the compressive strength of concrete (f′c ) (40–120 MPa), shear span-to-depth ratio (1, 1.5, 2, 2.5, and 3), and the ratio of the amount of flexural steel bar ratio (1.35%, 2.40%, 3.76%, and 6.108%). Experimental results showed that increasing concrete compressive strength and flexural steel bar ratio increased ultimate shear capacity. By contrast, increasing shear span-to-depth ratio and span-to-depth ratio reduced ultimate shear capacity. Based on the test results of this investigation (16 beams) and those of available literature (233 deep beams), an equation that considered the parameters affecting shear stress (f′c, l/d, a/d, andw) was proposed using SPSS software. The proposed equation was compared with predictions made by the American Concrete Institute (ACI) and the works of other researchers, including that of Zsutty and Aziz. The ACI predictions were conservative and the proposed equation had a lower coefficient of variation.


Article
The Effects of Adding Waste Plastic Fibers (WPFs) on Some Properties of Self Compacting Concrete using Iraqi local Materials
تأثير اضافة الياف الفضلات البلاستيكية على خواص الخرسانة ذاتية الرص المصنعة من مواد محلية الصنع

Loading...
Loading...
Abstract

This study presents an experimental research of Self-Compacting Concrete (SCC) properties containing waste plastic fibers (WPF). Adding waste plastics which resulting from cutting PET bottles as fibers to SCC with aspect ratio (l/d) equal to (28). To illustrate the effects of WPFs on the SCC, the current study was divided into two parts, the first part shows the effect of adding plastic fibers on the properties of fresh SCC, which include the ability flow, spread, passing and resistance to segregation, and the second part to evaluate the properties of hardened (mechanical) destructive and non-destructive, which include compression strength, flexural strength and ultrasonic pulse velocity test. One reference concrete mix was conducted and eight mixes contain WPF has been producing self-compacting concrete mixers containing a different volumetric ratio of plastic fibers (Vf) % percentages (0.25, 0.5, 0.75, 1, 1.25, 1.5, 1.75, 2) %. Three cubes samples were prepared for testing the compressive strength, three prisms were prepared for the test modules of rupture, one cylinder were prepared testing the modulus of elasticity.The experiments show that adding plastic fibers to SCC leads to an increase in the compression strength and modulus of rupture at 28-day as follows (42.30)% and (73.12)% respectively for mix ratio (1.5)% in comparison with the reference mix, which represent the best ratio of fibers, as such the results of testing the fresh concrete containing waste fibers showed that adding these fibers led a reduction in workability for SCC.

تقدم هذة الدراسة بحثاً عملياً لخواص الخرسانة ذاتية الرص المسلحة والمحتوية على ألياف الفضلات البلاستيكية. تم أضافة نواتج التقطيع اليدوي للقناني البلاستيكية (المستخدمة في حفظ المشروبات الغازية) حيث تم تقطيعها بنسبة باعية (الطول/العرض) (28). لتوضيح تأثير الألياف البلاستيكية على سلوك الخرسانة الذاتية الرص, تم تقسيم الدراسة الحالية إلى جزئين, الجزء الأول يوضح تاثير الألياف البلاستيكية على الخواص الطرية للخرسانة ذاتية الرص والتي تشمل قابلية الأنسياب, الأنتشار, المرور ومقاومة الانعزال, في حين كان الجزء الثاني يشمل تقييم الخواص المتصلبة (الميكانيكية) الأتلافية وغير الأتلافية والتي تشمل مقاومة الأنضغاط, الأنثناء (معامل الكسر) والموجات فوق الصوتية.تم تصميم خلطة مرجعية واحدة في هذا البحث والتي تم أعتمادها كأساس لتطوير الخلطات الأخرى، في حين تم صب (8) خلطات خرسانية ذاتية الرص محتوية على نسب حجمية مختلفة من الألياف البلاستيكية % (fV) ، حيث كانت تلك النسب (0.25, 0.5, 0.75, 1.0, 1.25, 1.5, 1.75 و 2)% لغرض المقارنة مع الخلطة المرجعية. تم صب ثلاث (3) مكعبات لفحص مقاومة الأنضغاط وثلاث (3) مواشير لفحص معاير الكسر و (1) أسطوانة لفحص معامل المرونة.أوضحت نتائج الفحوصات العملية للدراسة الحالية أن إضافة الألياف البلاستيكية إلى الخرسانة ذاتية الرص كان لها تأثير إيجابي في زيادة مقاومة الأنضغاط ومقاومة الأنثناء، حيث كان مقدار الزيادة بعمر (28) يوم يساوي (42.30%) و(73.12%) على التوالي عند نسبة المزج (1.5 %) بالمقارنة مع الخلطة المرجعية والتي تمثل أفضل نسبة حجمية للألياف, كما بينت نتائج الفحوصات الطرية للخلطات الخرسانية الحاوية على الألياف البلاستيكية بأن أضافة الألياف يؤدي إلى أنخفاض في قابلية التشغيل للخرسانة الذاتية الرص.


Article
T-Beam Behavior In Flexure With Different Layers Of Concrete In Web And Flange

Author: Dhia B. Ghailan
Journal: KUFA JOURNAL OF ENGINEERING مجلة الكوفة الهندسية ISSN: 25230018 Year: 2010 Volume: 2 Issue: 1 Pages: 53-61
Publisher: University of Kufa جامعة الكوفة

Loading...
Loading...
Abstract

This study presents an experimental investigation performed to investigate the behavior of reinforced concrete T-beams with different types of concrete in web and/or flange.More rational way has been used by strengthening the web and the flange by steel fiber reinforced concrete (SFRC) and strengthening the flange by high strength concrete (HSC). Tests were carried out on six beams, simply supported under a single point loading at mid-span. Two of which were made fully with normal strength concrete (NSC) as reference beams, and the others were made fully or partially with (SFRC) and (HSC) in web and/or flange.Experimental results show that all specimens behaved linearly up to a loading of (40-48 kN) depending on types of concrete used. The maximum deflection increased by (153%) for a beam with SFRC in both web and flange and by (60.8%) for a beam with SFRC in web and normal concrete in flange while it decreased by (50.22%) for a beam with normal concrete in web and high strength concrete in flange in comparison with the reference beams. No interest change in maximum deflection occurred for a beam with SFRC in web and high strength concrete in flange. . The first cracking load increased by (161%) for a beam with SFRC in web and high strength concrete in flange and no interest changes occurred for the other beams. This pattern of combination of concrete types may be useful in T-beams used in bridges or wide spans structures and to reduce the cracking of concrete up to failure.

تقدم هذه الدراسة بحثا تجريبيا لدراسة سلوك الأعتاب الخرسانية نوع( تي) باستخدام أنواع مختلفة من الخرسانة في الشفة العليا و/او النصل. لقد تمت تقوية الخرسانة في النصل باضافة الياف الحديد وتقوية الشفة العليا باستخدام الخرسانة عالية المقاومة وتم اجراء الاختبار على ستة نماذج لاعتاب بسيطة الاسناد سلط عليها حمل مفرد في الوسط.اثنان من هذه النماذج صنعت باكملها من الخرسانة الاعتيادية(بدون اضافات)كنماذج مرجعية بينما تم تصنيع النماذج الاخرى بصورة جزئية او كاملة من الخرسانة المسلحة بالياف الحديد او الخرسانة عالية المقاومة في النصل و/او الشفة . لقد اظهرت النتائج العملية للاختباران جميع النماذج سلكت سلوكا مرنا الى حد الحمل من 40 كيلونيوتن الى48 كيلونيوتن اعتمادا على نوع الخرسانة المستخدمة.لقد ازداد مقدار الانحراف الأقصى بنسبة (153 %) للنموذج المصنع كليا من الخرسانة المسلحة بالياف الحديد وبنسبة (60.8 %) للنموذج الذي يحتوي على الياف الحديد في النصل وخرسانة اعتيادية في الشفة العليا بينما انخفض الحيد الاقصى بنسبة (50.22 %) في النموذج المصنع من خرسانة اعتيادية في النصل وخرسانة عالية المقاومة في الشفة العليا بالمقارنة مع النماذج المرجعية. لم يحصل تغير ملحوظ في قيمة الانحراف الأقصى بالنسبة للنموذج المصنع من الخرسانة المسلحة بألياف الحديد في النصل والخرسانة عالية المقاومة في الشفة العليا. لقد ازدادت قيمة الحمل المقابل لاول تشقق في الخرسانة في النموذج المصنع من الخرسانة المسلحة بألياف الحديد في النصل والخرسانة عالية المقاومة في الشفة العليا بينما لم تحصل تغييرات مهمة في النماذج الأخرى. ان هذا النوع من التعشيق بين الأنواع المختلفة من الخرسانة يمكن الاستفادة منه في المقاطع المستخدمة في الجسور او تلك المستخدمة في تسقيف الفضاءات الواسعة كما انه قد يكون مفيدا في التقليل من التشققات التي تظهر في هذه الجسور.


Article
Experimental Study for Punching Shear Behavior in RC Flat Plate with Hybrid High Strength Concrete
دراسة عملية لمقاومة القص الثاقب للسقوف الخرسانية المستوية المصنوعة من الخرسانة الهجينية عالية الانضغاط

Authors: Ban Sahib A. بان صاحب --- Shatha S. Kareem شذى صاحب كريم --- Ali H. Aziz علي حميد عزيز
Journal: Journal of Engineering and Sustainable Development مجلة الهندسة والتنمية المستدامة ISSN: 25200917 Year: 2013 Volume: 17 Issue: 3 Pages: 105-119
Publisher: Al-Mustansyriah University الجامعة المستنصرية

Loading...
Loading...
Abstract

This Paper is conducted to investigate experimentally the punching shear behavior of hybrid flat plate. Five slab specimens with (1000x1000x70) mm dimensions have been tested, two of which have been made fully with High Strength Concrete and Steel Fiber Reinforced Concreter , while, the others have been made by mixing two types of concrete (Steel Fiber Reinforced Concreter in the critical zone and High Strength Concrete in the other part of slab specimen). The slab dimensions, main reinforcement have been kept constant in all slab specimens. The variables are concrete type and dimensions of critical area. Experimental results show that the use of SFRC improves the punching shear resistance and allows higher forces to be transferred through the slab-column connection. For slab specimen which made fully with SFRC, the ultimate shear capacity increased by (25%) in comparison with the normal slab. While, for slab specimens which made with hybrid concrete the ultimate shear capacity increased by (5%-13%) in comparison with the normal slab.

تأثير استخدام أنواع مختلفة من الخرسانة (الخرسانة الهجينية) في المنطقة الحرجة لالتقاء العمود مع البلاطة على مقاومة القص الثاقب في البلاطات الخرسانة الصفائحية تمت دراستها في هذا البحث. تم فحص خمسة بلاطات مربعة الشكل بأبعاد (1000*1000*70) ملم بالإضافة الى سلسلة من الفحوصات التي تم أجراءها على نماذج السيطرة لدراسة الخواص الميكانيكية لأنواع الخرسانة المستخدمة. المتغيرات في هذه الدراسة هي نوع الخرسانة في المنطقة الحرجة وأبعاد هذه المنطقة مع الإبقاء على أبعاد البلاطات و حديد التسليح دون تغيير .تعرضت كلا من النماذج المرجعية و بلاطات الفحص الى نفس الظروف المختبرية. أظهرت النتائج المختبرية أن الزيادة في مقاومة انضغاط الخرسانة حسن مقاومة القص الثاقب وهذا يسمح بانتقال قوة اكبر من خلال المفصل الرابط بين العمود والبلاطة. كذلك، بينت النتائج أن مقاومة القص الثاقب قد ازدادت بمقدار (25%) بالنسبة للبلاطات المسلحة بالكامل بألياف الحديد عند مقارنتها مع البلاطة العادية. أظهرت النتائج، كذلك، حصول زيادة في المقاومة القصوى للقص الثاقب بمقدار (5%-13%) بالنسبة للبلاطات المسلحة جزئيا بألياف الحديد عند مقارنتها مع البلاطة العادية.


Article
REPAIRED REINFORCED CONCRETE BEAMS WITH NORMAL AND HIGH STRENGTH CONCRETE
تصليح الأعتاب الخرسانية المسلحة لخرسانة ذات مقاومة اعتيادية وخرسانة ذات مقاومة عالية

Author: Emad Yassin Khudhair عماد ياسين خضير
Journal: DIYALA JOURNAL OF ENGINEERING SCIENCES مجلة ديالى للعلوم الهندسية ISSN: 19998716/26166909 Year: 2013 Volume: 6 Issue: 2 Pages: 21-37
Publisher: Diyala University جامعة ديالى

Loading...
Loading...
Abstract

In recent years several attempts were undertaken to repair damaged reinforced concrete structures. Studies on the effectiveness of repaired and strengthened reinforced concrete elements which fail primarily due to formation of major flexural cracks are same what limited for normal strength concrete (NSC) and very limited for high strength concrete (HSC). The overall objective of the present work is to investigate the strength and deformation characteristics in flexure of reinforced HSC and NSC beams repaired with either with concrete alone or with fiber reinforced concrete or with Welded Wire Mesh (W.W.M). From the results obtained, it was found that the beams were adequately repaired and the general mode of failure was flexural. The repaired beams had higher strength than the original beams. All repaired beams exhibited significant decrease in deflection than the original beams.

حديثاً هناك عدة محاولات أُجريت على تصليح المنشآت الخرسانية المسلحة. هذه الدراسات تركزت على فعالية التصليح والتقوية للعناصر الخرسانية المسلحة التي كان الفشل بسبب الشقوق الإنشائية الرئيسية وهذه الدراسات قليلة بالنسبة للخرسانة ذات المقاومة الاعتيادية وأكثر قلة بالنسبة للخرسانة ذات المقاومة العالية. الهدف من البحث لدراسة السلوك والتشوهات في العتبات الخرسانية ذات خرسانة اعتيادية وخرسانة ذات مقاومة عالية والتي تم تصليحها بالطريقة الاعتيادية أو بإضافة ألياف الحديد أو باستخدام المشبكات الحديدية. من نتائج الدراسة، وجد بان الأعتاب الخرسانية تم تصليحها بشكل جيد وكان نمط الفشل عن طريق الانثناء. الأعتاب المصلحة كانت ذات مقاومة أعلى من الأعتاب الأصلية وكل الأعتاب المصلحة أبدت نقصان واضح في الأود بالمقارنة مع الأعتاب الأصلية.


Article
Stress-Strain Relationship for Steel-Fiber Reinforced Polymer Modified Concrete under Compression
علاقة الاجهاد-الانفعال للخرسانة المسلحة بالالياف الحديدية والمحورة بالبوليمر تحت الانضغاط

Loading...
Loading...
Abstract

The present study, concern about an experimental work to study the stress-strain relationship of steel-fiber reinforced polymer modified concrete under compression.Four different mixes with weight proportions of (1:2:4) were used as; normal weight concrete (NC), polymer modified concrete (PMC) with (10%) of cement weight and two mixes of steel-fiber polymer modified concrete with (1%) and (2%) volume fraction of steel fiber, (SMPC).The influences of polymer and fiber addition on peak stress, strain at peak stress and the stress-strain curve were investigated for concrete mixes used. For all selected mixes, cubes (150×150×150mm) were made for compressive strength test at (28) days while stress-strain test was caried out on cylinders (150 mm  300 mm) at the same age.Results showed an improvement in compressive strength of polymer modified concrete (PMC) over reference mix, the maximum increase of it was (13.2 %) at age of (28) days. There is also an increase in compressive strength with increasing of steel fibers content with comparison to normal concrete, the maximum increases of it were (19.6% and 25.2%) of mixes with 1% and 2% fiber content by volume respectively. In terms of modulus of elasticity, the addition of polymer and the presence of fibers cause a significant increase in it.The peak of stress- strain curve for normal strength concrete (Mix No.1) was linear whereas it was more sharp for the other mixes. The behaviour of normal strength concrete (Mix No.1) was linear up to 20 % of ultimate strength, while for the mixes with the higher strength i.e. polymer modified concrete and fibers reinforced concrete (Mixes No.2, 3 and 4) the linear portion increases up to about 50 % of ultimate strength

تتمحور هذه الدراسة حول الفحصوصات المختبرية لدراسة علاقة الاجهاد-الانفعال تحت حمل الضغط للخرسانة المسلحة بالالياف الحديدية والمطورة بالبوليمير. كما وتم استخدام اربع خلطات بنسب خلط (4:2:1) وكانت عبارة عن خرسانة اعتيادية وخرسانة مطورة بالبوليمر بنسبة وزنية قدرها (10%) وخلطتين لخرسانة مطورة بالبوليمر ومسلحة بالالياف الحديدية بنسب حجمية (1%) و (2%).تم في هذه البحث دراسة تاثير اضافة البوليمر ((SBR والالياف الحديدية على الاجهاد الاقصى, الانفعال عند الاجهاد الاقصى و طبيعة الاجهاد-الانفعال للخرسانة المستخدمة. تم فحص مقاومة الانضغاط بعمر (28) يوم باستخدام مكعبات بابعاد (150×150×150) ملم بينما تم دراسة منحني الاجهاد-الانفعال باستخدام اسطوانات بابعاد (150×300) ملم.اوضحت النتائج المختبرية بان هناك تحسن في مقاومة الانضغاط بعمر (28) يوم عنها للخلطة المرجعية (خلطة رقم 1) بمقدار (13.2%) للخلطة الحاوية على البوليمر (خلطة رقم 2) وكانت هذه الزيادة بمقدار (19.6%) و (25.2%) للخلطتين الحاويتين على البوليمر والالياف الحديدية بنسب حجمية (1%) و (2%) على التوالي. كما اظهرت النتائج بان اضافة البوليمر او/ و الالياف الحديدية أدى الى زيادة ملحوظة في معامل مرونة الخرسانة المنتجة.اثبتت النتائج بأن تصرف منحني الاجهاد-الانفعال للخلطة المرجعية (خلطة رقم 1) كان خطياً الى (20%) من الاجهاد الاقصى بينما ازداد التصرف الخطي للخلطات الاعلى مقاومة (الخرسانة المحورة بالبوليمر والمسلحة بالألياف) ليصل بحدود (50%) من الاجهاد الاقصى.


Article
EXPERIMENTAL AND NUMERICAL ANALYSIS OF STEEL FIBER REINFORCED CONCRETE PAVEMENT
فحص ونمذجة التبليط الجاسىء المسلح بألياف الحديد

Authors: Rusul Raed Abdull-Hussain --- Ahmed Saheb Daib --- Zainab A. AL-Kaissi
Journal: Journal of Engineering and Sustainable Development مجلة الهندسة والتنمية المستدامة ISSN: 25200917 Year: 2016 Volume: 20 Issue: 6 Pages: 135-155
Publisher: Al-Mustansyriah University الجامعة المستنصرية

Loading...
Loading...
Abstract

The objective of this work is to compare the results obtained by modelling flexural strength test (Three Point Bending Test) of steel fiber reinforced concrete (SFRC) beam specimens using a numerical 3D modelling introduced by the computer code "ABAQUS" after conducting the (SFRC) beam specimens of (0.0, 0.4 and 0.8) % volume fraction of steel fiber (vf) to three point bending test using a hydraulically increasing universal testing machine under monotonic loads up to ultimate load with two different rates of loading (0.5 and 1) kN/sec. Deflection, stress and strain were obtained and the test is simulated using the computer code "ABAQUS" . Test results show that deflection, stress and strain magnitudes are directly proportion to the increment of steel fiber and a good agreement can be seen between the experimental results and the analytical approaches, finally comparison using "ABAQUS" is carried out between horizontal tensile stress and strain at bottom of concrete pavement for (0.0, 0.4, and 0.8) % (vf) of steel fiber and results analysis show that the ability of concrete pavement to withstand higher magnitudes of tensile stress and strain without deterioration increase as steel fiber content increase due to high tensile strength of steel fiber.

الهدف من هذا البحث هو لمقارنة النتائج التي تم الحصول عليها عن طريق نمذجة اختبار قوة الأنحناء (اختبار الانحناء الثلاثي الساكن) للخرسانة المسلحة بأستخدام ألياف الحديد (SFRC) لنماذج العتبات باستخدام النمذجة العددية (3D ( بواسطة شفرة الكمبيوتر "ABAQUS" بعد إجراء فحص الانحناء الثلاثي الساكن لنماذج العتبات (SFRC ) المحتوية على (0.0، 0.4 و 0.8)٪ نسب حجمية (vf) من الياف الحديد باستخدام الآلة العالمية لزيادة الحمل هيدروليكيا (نظام MFL) بصورة ثابتة حتى التحميل النهائي مع معدلين مختلفين للتحميل (0.5 و 1) كيلو نيوتن / ثانية. تم الحصول على قيم كل من الهطول، الإجهاد والانفعال وتمت محاكاة الفحص باستخدام شفرة الكمبيوتر "ABAQUS". تظهر نتائج الاختبار أن قيم كلا من الهطول ,الإجهاد والانفعال تتناسب طرديا مع زيادة الياف االحديد وهناك تطابق جيد يمكن أن ينظر إليه بين النتائج العملية والمناهج التحليلية، واخيرا تمت مقارنة قيم اجهاد وانفعال الشد الافقي باستخدام "ABAQUS" في الجزء السفلي من الرصف الخرساني للنسب الحجمية (0.0، 0.4، و 0.8)٪ ((vf من الياف الحديد والتي تبين من تحليل النتائج أن قدرة الرصف الخرساني على تحمل درجات أعلى من إجهاد الشد والانفعال دون حصول تدهور; تزداد مع زيادة محتوى ألياف الحديد بسبب قوة الشد العالية لألياف الحديد