Heat Rejection From Horizontal Tube Through Heat Valve
طرح الحرارة من أنبوب أفقي خلال صمام حراري

Author: Ali D.Salman
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2012 Volume: 30 Issue: 13 Pages: 2229-2251
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

This study presents experimental work to construct a non- conventionalthermosyphon where it is consists of three parts, which include the evaporator,adiabatic and condenser sections all of these parts are arranged radially in parallel toconstruct the heat valve (HV). Heat valve used to evacuate heat from horizontal copperelectrical heater tube by working fluid which is(distilled water, methanol, ethanol) withdifferent filling ratio 66.6% and 83.3%. Working fluid evacuate heat from copperevaporator towards condenser where a change in phase mechanism make insure toincrease the heat performance of HV. Thin stainless steel mesh grid coated evaporatorto translate heat to the working fluid at the case of high evaporation of working fluid,while a very thin of aluminum fins are fixed to the condenser surface to extended it andconstruct the finned heat valve(FHV) with a high level thermal performance whereheat reject in short time and make insure to condensate the working fluid’s vapor andthat lead to low level of temperature in evaporator. The results refer to the highthermal performance of FHV where a low temperature in evaporator with low heatstorage because the short distance between condenser and evaporator with a high ratiobetween area of them .Result refer to the effect of working fluid type with simpleeffect in filling ratio.

من خلال هذه الدراسة العملية تم بناء ثرموسايفون غير تقليدي حيث المناطق الثلاث الأساسية(مبخر، أديباتي،المكثف) مرتبه بشكل قطري على التوازي وليس على التوالي كما في الثيرموسايفونالتقليدي لتكوين الصمام الحراري. استخدم الصمام لإزالة الحرارة من مسخن كهربائي بهيئة أنبوبنحاسي أفقي وباستخدام كل من الايثانول، الميثانول والماء المقطر كمائع عامل وبنسب ملء مختلفة%83.3 )،حيث إن المائع العامل يعمل على نقل الحرارة من المبخر (الأنبوب النحاسي ) ،%66.6 عن طريق الحمل ثنائي الطور نتيجة التغيير ألطوري للمائع العامل والذي يضمن كفاءة حرارية عاليةللصمام الحراري . كما تم استخدام شبكه معدنية في غاية الدقة ومصنعه من الفولاذ تغطي المبخرلتوصيل الحرارة للمائع العامل في حال نسب التبخر العالي للمائع العامل، ولرفع الأداء الحراريللصمام الحراري تمت زعنفة المكثف بزعانف رقيقة السمك مصنعه من الألمنيوم لزيادة ألمساحهالسطحية للمكثف من جهة الهواء ومن ثم تأمين طرح الحرارة بشكل سريع وضمان تكثيف المائعالعامل لضمان تبريد أسرع للمبخر.أشارت النتائج إلى أن استخدام الصمام الحراري المزعنف والذي تكون فيه المسافة بين المبخروالمكثف قريبة جدا ومتقابلة إشعاعيا كما أن مساحة المكثف المزعنف اكبر بكثير من المبخر مماأدى إلى طرح الحرارة بشكل سريع (تقليل الحرارة ألمخزونه) والذي أدى بدوره إلى خفض في درجةحرارة المبخر أي أن أداءه الحراري عالي، كما أشارت الدراسة إلى تأثير ملحوظ في تغيير نوعالمائع العامل للصمام الحراري المزعنف مع تأثير بسيط لنسبة الملء.


Article
Experimental and Numerical Investigation to Evaluate the Performance of U-Longitudinal Finned Tube Heat Exchanger
تحقيق عملي ونظري لتقييم أداء مبادل حراري من نوع الأنبوب المزعنف بزعانف طولية على شكل حرف U

Loading...
Loading...
Abstract

Experimental and numerical investigation has been performed in this work to evaluate the performance for U-longitudinal finned tube heat exchanger. Four pairs of U-shaped longitudinal fins were selected and manufactured from copper material and welded on the straight copper tube. The inner tube is inserted inside insulated galvanized tube, sheet and roll insulation (arm flux) and glass wool have been utilized to cover inner and outer surface of galvanized tube for reducing heat losses. Air at various mass flow rates (0.03 to 0.07)kg/sec flows through annuli and de-ionized water at Reynold's numbers ranging from (270 to 1900) flows through the inner tube. Performance of (smooth and finned) tube heat exchanger was investigated experimentally. Experimental results showed (1.744 to 2.534) enhancement ratio when using U-longitudinal fins. Empirical correlations for air, water were represented by Nusselt's number. Numerical simulation has been carried out on present heat exchanger to analyze flow field and heat transfer using FLUENT package 14. The comparison between experimental work and numerical results showed good agreement.

في هذه الدراسة, تم انجاز تحقيق عملي وعددي لمبادل حراري من نوع الانبوب المزعنف بزعانف طولية علئ شكل حرف (U) من اجل دراسة اداءه الحراري. اربعة ازواج من الزعانف الطولية ذات شكل (U) تم تصميمها وتصنيعها من مادة النحاس وثبتت علئ انبوب نحاس الذي اولج داخل انبوب مصنع من مادة الكلفنايز ومعزول بعوازل من الداخل والخارج لتقليل الحرارة المفقودة. هواء عند معدلات تدفق كتلية تتراوح بين (0.03 الئ0.07 ) كغم/ثانية يجري خلال الفراغ الحلقي وماء منزوع الايونات ذو ارقام رينولدز تتراوح بين (270 الئ 1900) يجري خلال الانبوب الداخلي. اداء المبادل الحراري بالحالتين ( الاملس والمزعنف ) تمت دراسته. النتائج العملية بينت ان نسبة التحسين كانت (1.744 الئ 2.534) في حال استخدام المبادل الحراري ذو الانبوب المزعنف. علاقات تجريبية لجانب الهواء والماء تم تقديمها بدلالة رقم نيسلت. محاكاة عددية تم انجازها للمبادل الحراري لتحليل جريان المائع وانتقال الحرارة باستخدام البرنامج المتخصص 14ANSYS FLUENT. بينت المقارنة بين النتائج العملية والعددية وجود تطابق مقبول.


Article
Modeling the Behavior of Frost Growth on Finned Tube Heat Exchanger
نمذجة تصرف نمو الصقیع على مبادل حراري ذو زعانف

Author: Zainab Hasoun H.Naji
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2014 Volume: 32 Issue: 1 Part (A) Engineering Pages: 215-229
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

A quasi-steady finite-volume model was developed for modeling a plain-finround-tube heat exchanger under frosted conditions. In this study, the heat and mass transfer characteristics of heat exchangers during frost formation process are analyzed numerically. Unsteady heat and mass transfer coefficients of the air side, heat transfer coefficient of the refrigerant side, frost layer thickness, the surface efficiency of theheat exchanger and the mass flow rate of the frost accumulated on the heat exchanger surface are calculated. The total conductivity (UA) and pressure drop of the heat exchanger are reported for different air inlet and refrigerant temperature. Results have shown that frost layer growth is faster with lower inlet air temperature. Using the developed mathematical model, the algorithm and the computer code, which havebeen experimentally validated, it is possible to predict a decrease of exchanged heat flux in the heat exchanger under frost growth conditions. The model could be further extended to simulate direct expansion evaporators with varying operating conditions and variable heat exchanger geometry.


Article
A Numerical Model For Thermal-Hydraulic Design of a Shell And Single Pass Low Finned Tube Bundle Heat Exchanger
نموذج عددي للتصميم الحراري- الهايدروليكي لمبادل من نوع القشرة وممر واحد لحزمة الأنابيب المزعنفة

Author: Ali Hussain Tarrad
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2007 Volume: 25 Issue: 4 Pages: 619-645
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

This investigation represents a computerized model for the thermal-hydraulicdesign of a single shell – single pass of enhance tube bundle heat exchanger usingthe step by step technique (SST). The design procedure suggested in this study isalso suitable for multi-tube passes using the most familiar methods of design ofshell and tube heat exchanger such as Kern and Bell-Delaware. The (SST) wasconsidered as a basic in order to incorporate the effect of the physical propertychange due to temperature variation along the heat exchanger. The model basicdesign depends on the selection of the low finned tube characteristics. The use ofsuch surface will have the advantage of avoiding the space restrictions of theequipment layout in the industrial applications and reduction in the cost ofmanufacture machining as well. The model was intended to be a choice for thelubricating oil cooling system of a gas turbine power station in Debis-Kirkukplant. The verification of the model showed that using such enhanced tubes in thecooling system will improve the operating conditions especially during summerseason in Iraq.

يقدم هذا البحث نموذج حاسوبي للتصميم الحراري – الهايدروليكي لمبادل من نوع القشرة وحزمة الأنابيبالتصميم المقترح لهذه .(SST) لممر واحد بأستخدام الأنابيب المطورة بإعتماد طريقة الخطوة -خطوةالدراسة يلائم المبادلات التي تحتوي على اكثر من ممر في جانب الأنابيب بأستخدام الطرق المعتمدة فيتم اعتماد طريقة الخطوة-خطوة كأساس للتصميم .(Bell-Delaware & Kern) تصميم هذه المبادلاتولضمان تأثير تغير المواصفات الفيزياوية للموائع نتيجة تغير درجة الحرارة على طول المبادل الحراري.يعتمد التصميم على اختيار المواصفات الفيزياوية (الأبعاد) لللأنابيب المزعنفة .أن استخدام مثل هذه الأنابيبله فائدة كبيرة بتجاوز المحددات الخاصة بالحيز والناتجة من توزيع المعدات في التطبيقات الصناعية وكذلكلخفض الكلفة التصنيعية لهذه المبادلات.النموذج المقترح قد تم انجازه ليشكل جزء رئيسي من منظومة تبريد زيت المحركات المستخدمة فيالوحدات التوربينية العاملة في محطة كهرباء (دبس-كركوك) لإنتاج الطاقة الكهربائية . وقد بينت نتائجالنموذج المقترح باستخدام الأنابيب الم زعنفة تحسن أداء هذه الوحدات وخصوصاً خلال فصل الصيف فيالعراق.


Article
Experimental investigation of the effect of hot finnedtube position on the heat transfer coefficient

Authors: Musa M. Wais --- Murad S. Sedeeq --- Ehsan F. Abbas
Journal: Journal of University of Babylon مجلة جامعة بابل ISSN: 19920652 23128135 Year: 2017 Volume: 25 Issue: 2 Pages: 685-692
Publisher: Babylon University جامعة بابل

Loading...
Loading...
Abstract

In the present study, an experimental investigation is carried out to calculate heat transfer coefficient from the change in position of a finned tube in the cross-flow heat exchanger in two different conditions, which are a constant temperature at 90oC and constant heat flux at 45W/m2. A standard laboratory device (crossflow heat exchanger) was used in experiment process, that which manufactured by EDIBON company. The air flow over finned tubes inside heat exchanger was studied at Reynolds number ranging from 3600 to 11600. The comparative of experiments results between two cases shows that the Nu number in four positions at the constant temperature condition are higher than symmetrical positions in constant heat flux. The results indicated that the position3 gives higher values of Nu number in both cases

تشمل الدراسة الحالية تحليل نتائج اختبارات التي اجريت لحساب قيمة معامل انتقال الحرارة و ثاثيرها بتغير موقع انبوب مزعنف في مبادل حراري متعامد وفي حالتين من التسخين ( ثبوت درجة حرارة 90 مئوية و فيض حراري ثابت 45 واط/م2). حيث اجريت الدراسة في مدى لجريان الهواء تتراوح من 3600 الى 11600 رقم رينولد وذلك من خلال استخدام مبادل حراري مختبري نوع متعامد مجهز من قبل شركة EDIBON المتخصصة في صناعة الاجهزة المختبرية. من خلال مقارنة نتائج للحالتين، تبين بان رقم نسلت عند المواضع الاربعة في حالة ثبوت درجات الحرارة اعلى من مواضع مماثلة عندحالة ثبوت الفيض الحراري ومن مجمل النتائج الاختبارات تبين بان الموضع رقم 3 تعطي اعلى قيم لرقم نسلت للحالتين.


Article
Experimental Investigation of Heat Transfer Enhancement by Using Different Number of Fins in Circular Tube
مبحث تجريبي لتحسين نقل الحرارة باستخدام عدد مختلف من الزعانف القرصية في أنبوب دائري

Author: Kamil Abdul Hussien كامل عبد الحسين
Journal: Wasit Journal of Engineering Sciences مجلة واسط للعلوم الهندسية ISSN: 23056932 Year: 2018 Volume: 6 Issue: 3 Pages: 1-12
Publisher: Wassit University جامعة واسط

Loading...
Loading...
Abstract

The present work investigates the enhancement of heat transfer by using different number of circular fins (8, 10, 12, 16, and 20) in double tube counter flow heat exchanger experimentally. The fins are made of copper with dimensions 66 mm OD, 22 mm ID and 1 mm thickness. Each fin has three of 14 mm diameter perforations located at 120o from each to another. The fins are fixed on a straight smooth copper tube of 1 m length, 19.9 mm ID and 22.2 mm OD. The tube is inserted inside the insulated PVC tube of 100 mm ID. The cold water is pumped around the finned copper tube, inside the PVC, at mass flow rates range (0.01019 - 0.0219) kg/s. The Reynold's number of hot water ranges (640 - 1921). The experiment results are obtained using six double tube heat exchanger (1 smooth tube and the other 5 are finned one). The results, illustrated that the heat transfer coefficient proportionally with the number of fin. The results also showed that the enhancement ratio of heat transfer for finned tube is higher than for smooth tube with (9.2, 10.2, 11.1, 12.1 13.1) times for number of fins (8, 10, 12, 16 and 20) respectively

الدراسة الحالية لتحسين انتقال الحرارة باستخدام عدد مختلف من الزعانف الدائرية (8،10،12،16،20.) زعنفة لمبادل حراري ثنائي الانابيب متعاكس الجريان تجريبيا. الزعانف مصنعة من النحاس بأبعاد (66)مليمتر قطر خارجي, (22) مليمتر قطر داخلي و (1) مليمتر سمك ومثقبة بثلاث ثقوب دائرية بزاوية (120˚) وبقطر (14)مليمتر. الزعانف مثبة على انبوب نحاس املس طوله 1م و 19.9ملم قطر داخلي و22.2ملم قطر خارجي.يثبت الانبوب داخل انبوب معزول من مادة PVC قطره الداخلي 100 ملم.الماء البارد يجهز بمعدل تدفق متغير0.01019 -0.0219 كغم/ثا والماء الساخن ذو ارقام رينولدز تتراوح بين640 الى 1921. بينت النتائج ان نسبة تحسن انتقال الحراره تتناسب مع عدد الزعانف ،حيث ان زيادة نسبة تحسن انتقال الحرارة بين انبوب املس واخر مزعنف بلغت (9.2, 10.2, 11.1, 12.1 13.1)مرة لعدد الزعانف(8،10،12،16،20.) بالتوالي.