research centers


Search results: Found 138

Listing 1 - 10 of 138 << page
of 14
>>
Sort by

Article
THE FLEXURAL PROPERTIES OF IRAQI-BAUXITE FILLED EPOXY COMPOSITES
خواص الحني لمادة مركبة اساسها راتنج الايبوكسي المدعم بحبيبات البوكسايت العراقي

Author: Thaer Abdalwahab Shihab ثائر عبد الوهاب شهاب حمد
Journal: AL-TAQANI مجلة التقني ISSN: 1818653X Year: 2014 Volume: 27 Issue: 4 Pages: E51-E61
Publisher: Foundation of technical education هيئة التعليم التقني

Loading...
Loading...
Abstract

This study is focus on the mechanical properties of Iraqi bauxite filled epoxy composites. In this study, bauxite content was varied systematically to evaluate their effect on the properties of the composites. The composites were prepared using gravity molding technique. From the flexural test results, it was observed that the flexural modulus increases with increasing bauxite content from 1.25 to 40 wt% with 40 wt% of bauxite content recorded the highest value of flexural modulus (4.93 GPa). In contrast, the flexural strength of the composites decreases with rising bauxite content till 20% and then increases with bauxite content increase from 20 to 40%. It has also been demonstrated that the pattern of flexural stress-strain curve is also affected with addition of bauxite particles. The flexural strain at break and the toughness decreases with bauxite content increase.These types of composite materials are suitable for use in braking systems with moderate loads, but vehicle manufacturers are tending to design increasing number of vehicles with more braking power, also used in textile for heavy duty stores.

تتمحور هذه الدراسة على الخواص الميكانيكية للمواد المركبة من الأيبوكسي المدعم بالبوكسايت العراقي. تتغير نسبة البوكسايت في هذه الدراسة بشكل منتظم لتقييم تأثيرها على خواص المواد المركبة. تم تحضير المواد المركبة باستخدام تقنية الصب. أظهرت نتائج اختبار الحني أن معامل المرونة تزداد بأزياد النسبة الوزنية للبوكسايت من 1.25% الى 40% حيث سجلت أعلى قيمة لها عند نسبة 40% بوكسايت بقيمة مقدارها 4.93 GPa. بينما تقل مقاومة الانحناء للمواد المركبة بازدياد النسبة الوزنية للبوكسايت لغاية 20% وبعد ذلك تزداد بازدياد نسبة البوكسايت بين 20% و 40%. كما ظهر جلياً تأثير اضافة حبيبات البوكسايت على منحنيات الاجهاد-الانفعال للحني. ان انفعال الحني عند الكسر والمتانة تنخفض بأزدياد محتوى البوكسايت في المادة المركبة. هذا النوع من المواد المركبة مناسب جداً في أنظمة التوقف للمركبات للأحمال المعدلة وكذلك تستخدم في أرضيات المخازن الثقيلة.


Article
Comparison study of some mechanical properties of micro and nano silica EP composites
دراسة مقارنة بين بعض الخصائص الميكانيكية للمتراكبات النانوية والمايكرو المكونة من الايبوكسي وحبيبات السيليكا

Authors: Ekram A. Al-Ajaj اكرام عطا العجاج --- Harith I. Jaffer حارث ابراهيم جعفر --- Muhannad M. Abd مهند مهدي عبد
Journal: Iraqi Journal of Physics المجلة العراقية للفيزياء ISSN: 20704003 Year: 2012 Volume: 10 Issue: 18 Pages: 62-68
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

The effect of micro-and nano silica particles (silica SiO2 (100 μm), Fused silica (12nm)) on some mechanical properties of epoxy resin was investigated (Young's modulus, Flexural strength). The micro-and nano composites were prepared by using three steps process with different volume fraction of micro-and nano particles (1, 2, 3, 4, 5, 7, 10, 15, and 20 vol. %). Flexural strength and Young's modulus of nano composites were increased at low volume fraction (max. enhancement at 4 vol.% ). However at higher volume fraction both Young's modulus and flexural strength decrease. Moreover, above, the mechanical properties are enhanced more than that of neat epoxy resin. The flexural strength decreases with increasing the volume fraction of micro silica especially at high volume fraction while Young's modulus increases with increasing the volume fraction. Gelling time of epoxy resin was highly affected by adding nano-particles and also using ultrasonic homogenizer. It was found that mode failures were depend on particles size and volume fraction.

تمت دراسة تاثير المضافات النانوية لجسيم السيليكا ( SiO2- 12 nm ) والمضافات المايكروية لجسيم السيليكا (SiO2-100 µm) على الخصائص الميكانيكية ( قوة الانحناء، معامل المرونة) لمادة الايبوكسي. حضرت المتراكبات النانوية والمتركبات المايكروية باستخدام طريقة من ثلاث مراحل (الخلط الميكانيكي والخلط بالامواج فوق الصوتية واستخدام تقنية التفريغ) ولعدة نسب حجمية (1, 2, 3, 4, 5, 7, 10, 15, 20%) حيث وجد ان قوة المتانة ومعامل المرونة يزداد بزيادة نسب الاضافات للمتراكبات النانوية وخصوصا في النسب ذات الاضافات القليلة حيث وصلت اعلى نسبة تحسن في الاضافة 4% وفي نسب الاضافات الاعلى ينخفض التحسن مع بقاء الخصائص الميكانيكية للمتراكبات اعلى من الخاصائص الميكانيكية لمادة الايبوكسي في حين ان اضافة الجسيمات المايكروية تؤدي الى انخفاض المواصفات الميكانيكية للمتراكبات مع ارتفاع معامل المرونة للمتراكبة المايكروية.كما قد لوحظ ان زمن التصلب يتأثر بأضافة المواد النانوية وبأستخدام طريقة خلاط الاهتزازات فوق الصوتية. ووجد ان نوع الفشل في العينة يتمدد على حجم وتركيز المضافات.


Article
Nonlinear Analyses of Partially Composite Steel Beams Encased in Concrete with Innovative Position of Stud Bolts

Author: Raad K. Shukur
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2009 Volume: 15 Issue: 1 Pages: 3368-3391
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

Static behavior of three partially encased composite steel beams with cambering under flexural condition is investigated in the context of studying some alternative positions for the headed studs. Shear resistance between the cambered I-shaped beam and the concrete was provided by headed studs in two positions: vertically welded on the bottom flange and horizontally welded on the faces of the web. In the present study, a nonlinear three-dimensional finite element analysis has been used to predict the load-deflection and moment-rotation behaviors of composite encased beams consisting of steel sections using the finite element computer program (ANSYS V. 10). Composite encased beams are analyzed and a comparison is made with available experimental load-deflection curves, good agreement with the experimental results is observed. Cambering of steel section is introduced on the steel section of the composite beams encased in concrete. It is found that using of steel section with cambering can increase the ultimate load capacity of the composite encased beam by relatively (15%) and also it is found that deflection are nearly (65% to 80%) the deflection of the same beam without cambering. Parametric studies have been carried out to study the increasing of the moment-carrying capacity due to the use of encased concrete; meanwhile the slip along the beams length is studied. The strain distributions along the steel section and encased concrete depth are also examined. The effects of concrete compressive strength on the stiffness of the composite encased beams are also investigated with the Poisson’s ratio of concrete and the effect of cambering of steel-section.

في البحث الحالي, تم التحري حول سلوك ثلاث نماذج من العتبات المركبة المثنية و المغلفة جزئياُ بالخرسانة تحث تأثير الاحمال الساكنة ضمن نهج عام يتمحور حول دراسة الموقع الافضل لوضع روابط القص ((Shear Studs. تم توليد مقاومة القص بين الكونكريت و المقطع الفولاذي المثني و من خلال روابط القص عن طريق موضعين رئيسين: الروابط الملحومه طولباُ و الروابط الملحومه أفقياُ. أستخدم في الدراسة الحالية, طريقة العناصر المحددة للتحليل اللاخطي ثلاثي الابعاد و ذلك لغرض تحري علاقة كل من الحمل بالهطول و كذلك العزم بالدوران للعتبات المركبة و التي تحتوي على عنصر فولاذي مثني مغلف بالخرسانة وباستخدام برنامج العناصر المحددة للتحليل الانشائي الـ(ANSYS). تم تحليل العتبات المركبة ذوات المقاطع المغلفة و تمت مقارنة نتائج منحنيات القوة و الهطول مع النتائج العملية المتوفرة, تم ملاحظة توافق جيد بين النتائج المستحصلة من البرنامج و النتائج العملية. تم توليد تحديب (أنثناء) في المقطع الفولاذي للعتبات المركبة المغلفة بالخرسانة. لقد لوحظ بأن استخدام المقاطع المثنية في العتبات المركبة و المغلفة بالخرسانة يؤدي الى زيادة قابلية تحمل تلك العتبات بمقدار (١٥٪), و كذلك لوحظ بأن الهطول الدوران يتراوح مابين (٦٥٪ الى ٨۰٪) من هطول الدوران للعتبات التي تحتوي على مقاطع مثنية. تم دراسة تأثير وجود الخرسانة المغلفة على زيادة قابلية تحمل العزوم للعتبات القشرية المركبة و المغلفة جزئياً بالخرسانة, في تلك الاثناء تم دراسة التزحلق الذي يحدث في سطح الاتصال و على طول العتب للعتبات المركبة أيضاً. بالاظافة الى ذلك تم دراسة نمطية توزيع الانفعالات على العمق الكامل للمقاطع الفولاذية و كذلك الخرسانة المغلفة. تم التحري عن مدى تاثير مقاومة أنضغاط الخرسانة على جسائة العتيات المركبة و المغلفة بالخرسانة.. و اخيراً, تم التحقق من تاثير كل من (Poisson’s ratio), مقدار تحدب (ثني) المقطع الفولاذي و مقدار نعومة (دقة) النموذج المعمول بالـ(ANSYS) على قابليات تحمل العتبات المركبة.


Article
EXPERMENTAL STUDY OF PUNCHING SHEAR FOR REINFORCED CONCRETE FLAT PLATE SLABS WITH COUPLED COLUMNS
دراسة عملية للقص الثاقب للبلاطات الخرسانية المسلحة ذات اعمدة مزدوجة

Loading...
Loading...
Abstract

This study is conducted to investigate the punching shear of reinforced concrete flat plate slabs supported by coupled columns; sixteen specimens with average cube compressive strength (fcu) of (28 MPa) were tested.The slab specimens were made with (850x470x50mm) dimensions and concrete cover of (15 mm). The specimens were tested over a simply supported span (800 x 420mm) at four sides. The variables investigated in this study are the shape of column and the clear distance between columns of the slab specimen. The specimens are divided according to column shape into two groups, each group includes eight specimens.The first group (group A) has two square columns with cross sectional dimensions of (75x75mm) and height of (75mm) and column cross-sectional area equals to (5626mm). The clear distance between columns were varied from (2 mm) to (325 mm) (equals to 0.05d to 9.3d). While, the second group (group B) has two circular columns with (85mm) diameter and (75mm) height and column cross-sectional area equals to (5671)mm with variable clear distance between them from (2 mm) to (315 mm) (equals to 0.05d to 9d ).The test results showed that, the ultimate load reaches the maximum value when the distance between columns equal to (9.3d and 9d) for group (A) and (B) respectively; and decreases by (6.5 to 33.9%) and by (16.4 to 35.9%) of the maximum ultimate load when the clear distance between columns decreases by (7d to 0.05d) for group (A) and (B) respectively.The test results show that when the clear distance between columns is in the range of (0.05d to 7d) ,the failure zone is separated as one zone ;while when the clear distance between columns is equal to (9.3d and 9d ), the failure zone separates into two zones

اعدهذا البحث لدراسة القص الثاقب للبلاطات الخرسانية المسلحة ذات أعمدة مزدوجة ، تتضمن الدراسة صب ستة عشر نموذج من البلاطات (الصفائح) الخرسانية المسلحة باستخدام خلطة خرسانية واحدة بمعدل مقاومة انضغاط(fcu) مساوية إلى (28MPa) .ابعاد البلاطات متماثلة (الطول , العرض والسمك) والمساوية إلى (470,850 و 50ملم ) وبنفس الغطاء الخرساني والمساوي إلى (15ملم). تم فحص النماذج على فضاء بسيط الإسناد من جميع إضلاعه الأربعة وبإبعاد (420x800 ملم)، المتغيرات التي تم دراستها في هذا البحث هي شكل العمود والمسافة الصافية ما بين الأعمدة. تم تقسيم النماذج إلى مجموعتين (A) و (B) حسب شكل العمود وبواقع ثمان نماذج لكل مجموعة.أعمدة ألمجموعه ( A) لها مقطع عرضي مربع الشكل طول ضلعه (75 ملم ) ومساحة مقطعه تساوي(5625ملم2) وارتفاع العمود يساوي (75ملم ) والمسافة الصافية بين الأعمدة متغيرة من (2ملم ) إلى (325 ملم) أي ((0.05dإلى (9.3d), بينما أعمدة المجموعة (B) لها شكل دائري بقطر (85ملم(ومساحة مقطعه (5675ملم2) وارتفاع العمود يساوي (75ملم ) والمسافة الصافية بين الأعمدة متغيرة من (2ملم ) إلى (315 ملم) أي ((0.05dإلى (9d) .بينت نتائج الفحوصات أن حمل الفشل وصل إلى أعلى قيمة عندما أصبحت المسافة بين الأعمدة مساوية إلى ( 9.3dو 9d) للمجموعتين(AوB) على التوالي ، وتتناقص هذه القيمة بنسبة تتراوح بين (6.5-33%) و(16.4-35.9%) من أقصى حمل للفشل عندما تناقصت المسافة بين الأعمدة من (7d) إلى (0.05d).عندما تكون المسافة الصافية بين الاعمدة بحدود (0.05dالى 7d) بينت نتائج الفحوصات أن منطقة الفشل تنفصل عن البلاطة كجزء واحد، لكن عندما تكون المسافة الصافية ما بين الاعمدة بحدود ( 9.3dو 9d) للمجموعتين (A) و (B) على التوالي فأن منطقة الفشل تنفصل عن البلاطة كجزئين منفصلين

Keywords

Punching --- Shear --- Flexural --- flat plate --- coupled --- columns


Article
Flexural Behavior Of R/C Beams With Externally Bonded Gfrp Sheets
مقاومة الأنثناء للعتبات الخرسانية المسلحة والمغلفة خارجياً باستخدام صفائح الألياف الزجاجية

Loading...
Loading...
Abstract

AbstractDuring the latest decades there has been a significant increase in using FRP (Fiber Reinforced Polymers) as a main material for external reinforcement in the construction industry.Externally bonded FRP sheets have been used to increase moment capacity of flexural members and to improve confinement in compression members. This paper summarizes the result of experimental and analytical studies on the flexural strengthening of reinforced concrete beams by external bonding of glass fiber reinforced polymer sheets to the tension face of the beam. Four beams, three with different thickness of GFRP sheets and one without GFRP sheets were tested using third-point loading over a span of 900mm.The tests were carried out under load control. The results indicate that the flexural strength of the beams increased significantly as the thickness of the sheet increased. Analytical study using a computer program based on strain compatibility is presented to predict the ultimate strength and load-deflection behavior of the beams. When the experimental results were compared with theoretical ones, good acceptable agreement was obtained which make it possible to consider and recommended this model in the design. Keyword: Analytical Study, Flexural Behavior, GFRPSheets, Strengthening.

الخلاصة زاد أستخدام ألياف البوليمر كمادة رئيسة في التسليح الخارجي للمنشآت الصناعية بشكل ملحوظ خلال العقود الاخيرة.أُستخدمت هذه المواد في زيادة مقاومة الأنثناء وزيادة مقاومة التحمل للأعضاء الخرسانية. يلخص هذا البحث نتائج عملية ونظرية لدراسة أُجريت حول تأثير التسليح الخارجي بصفائح الألياف الزجاجية على مقاومة الأنثناء للعتبات الخرسانية وذلك عن طريق تقويتها في منطقة الشد. لأجراء هذه الدراسة تم صب أربعة عتبات خرسانية، ثلاث عتبات تم تسليحها خارجياً بصفائح ألياف البوليمر، المتغير الوحيد في هذه العتبات هو درجة التقوية (سمك التغليف)،أما العتبة الرابعة فلم تغلف على أعتبار أنها نموذج سيطرة، تم تحميل هذه النماذج في نقاط الثلث ولفضاء يساوي (900mm)، أظهرت نتائج الفحص زيادة واضحة في مقاومة الانثناء للعتبات الخرسانية وان قيمة هذه الزيادة تعتمد بالدرجة الأولى على سمك ألياف البوليمر(التسليح الخارجي)، بزيادة السمك ازدادت قيمة مقاومة الانثناء للعتبات. تم إجراء دراسة نظرية يمكن من خلالها التنبؤ بسلوكية العتبات الخرسانية المغلفة خارجياً بصفائح ألياف البوليمر من خلال توازن القوى داخل المقطع بأفتراض حالةتوافق الانفعالات فيه، وبمقارنة النتائج العملية بالنتائج التي تم الحصول عليها من الدراسة النظرية يمكن القول بأن هناك توافق جيد ومقبول والذي على أساسه يمكن أعتماد هذا النموذج في التصميم.


Article
Optimum Position of Shear Reinforcement of High-Strength Reinforced Concrete Beams
الموقع الامثل لحديد تسليح القص لعتبات خرسانية ذات المقاومة العالية

Authors: Omar Qarani Aziz --- Sinan Abdulkhaleq Yaseen
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2013 Volume: 31 Issue: 1 Part (A) Engineering Pages: 42-52
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

This paper reports experimental data on the behavior and strength of high-strength concrete slender beams reinforced with vertical shear reinforcement. Tests were conducted on ten reinforced concrete beams with stirrups in different positions using high-strength concrete (compressive strength about 85.0 MPa). The beams measured 2000 mm long, 100 mm wide and 200 mm deep, and were tested under two point loads. The test variables were position and amount of web reinforcement; conventional steel bars were used as longitudinal reinforcement in this investigation. The test results indicated that beams with shear reinforcement (vfy = 1.65 to 4.24MPa) within the shear span (G1) and along the beam length (G2), were failed in flexure, while beams with shear reinforcement (vfy = 1.65 to 4.24MPa) between two point loads (G3) and the beam without shear reinforcement (G4) were failed in shear. The optimum position of stirrups is the shear span for high strength concrete beams and for different amounts

في هذا البحث تم دراسة سلوك ومقاومة عتبات خرسانية ذات المقاومة العالية مع حديد تسليح قص عمودي. تم صب وفحص عشرة نماذج من الخرسانة المسلحة لمواقع مختلفة لحديد القص ومقاومة الانظغاط بحدود 85 ميكاباسكال. ابعاد النماذج كانت 150 ملم (عرض) و 200ملم (عمق) و 2000ملم (طول), تم فحص النماذج تحت تأثير نقطتين حميل,(Two-Point Loads), اهم المتغيرات الرئيسية في هذا البحث هي كمية و موقع حديد التسليح القص, واستخدام تسليح اعتيادي للانحناء ولجميع النماذج. اظهرت النتائج بأن نماذج مجموعة (G2,G1) ذات حديد تسبيح قص في منطقة فضاء القص و على طول النموذج فشلت في الانحناء ( مقاومة القص كانت عالية), بينما نماذج مجموعة (G4,G3) فشلت في القص. امثل وافضل موقع لحديد التسليح للعتبات ذات مقاومة خرسانية عالية هي فضاء القص.

Keywords

beams --- Concrete --- Flexural --- High strength --- Position --- stirrups


Article
Effect of Fiber Volume on The Flexural Strenght of Steel Fiber Reinfored Polyester Resin Composite
تأثير الكسر الحجمي في متانة الالتواء لمتراكبات البولي استير المدعم بالياف الحديد

Authors: Harith I.Jaffer حارث ابراهيم جعفر --- Awattif A Mohammed عواطف عذاب محمد --- Ban M.Al-Shabander بان مازن الشابندر
Journal: Iraqi Journal of Science المجلة العراقية للعلوم ISSN: 00672904/23121637 Year: 2013 Volume: 54 Issue: 1 Pages: 105-109
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

The aim of this study is to determine the flexural properties of steel fiber as a metal fiber and polyester resin as a matrix. The steel fibers were added to polyester resin at the various fiber volume fractions of 5, 10, and 15% steel fiber, and with different fiber orientations such as woven steel fiber type (0-45) ° and woven steel fiber type (0-90) ° indicate. Hand layup processes in these experiments were used to produce specimens test with the curing time of 24 hr. for the composite at room temperature. The results show that the flexural strength and flexural modulus values for 15 % vol.of woven steel fiber composite type (0-90) ° are (210MPa) and (2.29GPa( respectively. The results above indicate that the woven steel fiber (0-90) ° has a better bonding between its fiber and matrix compare to woven steel fiber type (0-45) °.

الهدف من هذه الدراسة هو تحديد خواص الالتواء لالياف الحديد كالياف معدنية وراتنج البولي استير كمادة اساس . الياف الحديد اضيفت الى راتنج البولي استير بكسور حجمية مختلفة هي 10,5و15% , مع اختلاف في اتجاه الالياف مثل حصيرة الالياف نوع (0-45) ° وحصيرة الالياف نوع (0-90) ° .تم تصنيع الواح من المتراكبات بطريقه التصنيع اليدوي مع زمن تصلب مقداره 24 ساعه بدرجه حرارة الغرفة.اظهرت النتائج قيم متانه الالتواء ومعامل الالتواء للكسر الحجمي 15% لمتراكبات حصيرة الياف الحديد نوع (0-90) °هي (210MPa)و((2.29GPa على التوالي.وبينت النتائج اعلاه ان حصيرة الالياف من نوع (0-90) ° تمتلك اليافها ترابط افضل مع المادة الاساس مقارنه لحصيرة الالياف نوع ° (0-45) .


Article
Effect of Addition of ZrO2 on Biaxial Flexural Strength of Calcium Phosphate Ceramics

Authors: R.Van Noort --- Maher K. Ali --- Mohammed Y.Shareef --- Mohammed K. Hilal
Journal: Tikrit Journal for Dental Sciences مجلة تكريت لعلوم طب الاسنان ISSN: 20731213 Year: 2014 Volume: 3 Issue: 1 Pages: 38-46
Publisher: Tikrit University جامعة تكريت

Loading...
Loading...
Abstract

AbstractThe aim of this study is to investigate the effect of addition of ZrO2 on the biaxial flexural strength (BFS) of ceramics fabricated using a conventional powder technology. Various compositions of hydroxyapatite (HAp) Ca10(PO4)6(OH)2 and zirconia powder ZrO2, ranging from 10 to 90 wt% ZrO2, were prepared using a wet mixing process. Ten compacts (13.5mm3mm) were made for each group, pressed and sintered in air at sintering temperatures from 1100 to 1450oC for up to 12 hours. The bulk density, porosity, linear shrinkage and BFS. The porosity reduced and linear shrinkage increased with increasing sintering temperature and amounts of zirconia, whereas the sintering time had little effect. The highest mean value achieved for the BFS was 26920 MPa for a composition of 70% ZrO2 and 30% HAp fired at 1450oC for 6 hours. From the experimental results can be conclude that sintering temperature and composition affect densification behaviour of calcium phosphate/ ZrO2 composites. The BFS increases with a reduction of porosity and increases with both sintering temperature and additions of ZrO2. It was noted that there is considerable scope for improvement in the BFS values by reducing the porosity of these composites.


Article
Flexural Behavior Of Reactive Powder Concrete Tee Beams
سلوك الانثناء لعتبات خرسانة المساحيق الفعالة بمقطع (T)

Loading...
Loading...
Abstract

Reactive powder concrete (RPC) is one of the latest and most important developments in concrete technology. This research presents experimental study to investigate the influence of three ratios of steel fibers (0, 1 and 2%) and three ratios of silica fume (15, 20 and 25%) on flexural behavior of RPC tee beams. The experimental results showed that steel fibers volumetric ratio is an important parameter in enhancing flexural behavior of tee beams, however as steel fibers volumetric ratio increase from 0 to 2% the first crack load, the ultimate flexural load and the ultimate deflection increased with percentages 55.56%, 57.32%, and 57.88% respectively as compared with nonfiberous RPC T-beams. The tests results also showed that the influence of silica fume ratio in the range of 15 to 25% is less significant.

تعتبر خرسانة المساحيق الفعالة واحدة من أحدث وأهم التطورات في تكنولوجيا الخرسانة. يقدم هذا البحث دراسة تجريبية تتحرى تأثير ثلاث نسب من ألياف الحديد (١٬٠ و٢٪) وثلاث نسب من بخار السليكا (٢٠٬١٥و٢٥٪) على سلوك الانثناء لعتبات خرسانة المساحيق الفعالة ذات المقطع (T). بينت نتائج الفحوص التجريبية أن النسبة الحجمية لألياف الحديد هي عامل مهم في تحسين سلوك الانثناء للعتبات ذات المقطع (T) حيث أنه عند زيادة النسبة الحجمية لألياف الحديد من ٠الى ٢٪ فأن حمل التشقق الأولي ٬ حمل الانثناء الأقصى والهطول الأقصى ازداد بالنسب ٥٥٫٥٦٪٬ ٥٧٫٣٢٪ و ٥٧٫٨٨٪ على التوالي بالمقارنة مع العتبة غير المحتوية على الألياف. كذلك بينت نتائج الفحوصات أن تـأثير نسبة بخار السليكا تكون أقل أهمية ضمن الحدود من١٥ إلى ٢٥٪.


Article
An Evaluation of Mechanical Properties of Different Types of Composite Resins (An in Vitro Study)

Author: Shaymaa SH. Hassan
Journal: Al-Rafidain Dental Journal مجلة الرافدين لطب الأسنان ISSN: 18121217 Year: 2014 Volume: 14 Issue: 1 Pages: 123-131
Publisher: Mosul University جامعة الموصل

Loading...
Loading...
Abstract

The aim of this study was to evaluate the mechanical properties (compressive strength (CS), diametral tensile strength (DTS), flexural strength (FS) and modulus of elasticity (ME)) of different types of composite resins. Materials and Methods: Two flowable composites (tgflow, Tetric N-Flow) and two conventional composites (tgmicrohybrid, Tetric N-Ceram), were used in this study. For CS measurement, eight specimens of each material (3mm diameter x 6mm height) were prepared. For DTS measurement, eight specimens of each material (6mm diamerter x 3mm height) were prepared. For FS measurement, of each material eight bar shaped (2mm x 2mm x 25mm) specimens were prepared. The FS and ME were determined by three point bending method. The specimens were stored in distilled water at 37˚C for 7 days, then tested on a universal testing machine at a crosshead speed of 1mm/mint. Independent sample t-test and Duncan test were used for statistical analysis. Results: The CS, DTS and ME of flowable composites were significantly lower than that of the conventional composites, the FS of flowable (Tetric N-Flow) composite was significantly lower than that of the conventional (Tetric N-Ceram) composites but there was no significant difference between tgmicrohybrid composite and tgflow composite in FS. Conclusions: It can be concluded that the mechanical properties of two flowa-ble types composites were inferior than that of the two conventional types composites

Listing 1 - 10 of 138 << page
of 14
>>
Sort by
Narrow your search

Resource type

article (138)


Language

English (114)

Arabic and English (16)

Arabic (4)


Year
From To Submit

2019 (8)

2018 (18)

2017 (19)

2016 (15)

2015 (14)

More...