research centers


Search results: Found 22

Listing 1 - 10 of 22 << page
of 3
>>
Sort by

Article
Experimental Study of the Influence of Baffles on Hydrodynamics of Gas- Solids Fluidized Bed System
دراسة عمليه لتأثير الحواجز على هيدرودايناميكية أعمدة التسييل غاز – صلب

Author: Jamal M. Ali
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2013 Volume: 31 Issue: 5 Part (A) Engineering Pages: 861-878
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

The objective of the present study was to determine the effects of the internals baffles on the gas-solids fluidized bed hydrodynamics, using a circular fluidized bed of Geldert group B sand particles. Bed expansion data were obtained for un baffled and two different types of baffled (rectangular and circular blades) gas-solids fluidized beds at varying operating conditions, namely air velocity ,particle size (755,424 , 205µm) and initial static bed heights.Experimental work was carried out in (0.1m) diameter and (1m) height circular fluidized bed column.The results of the study showed that the particle size affects the measured hydrodynamic behavior especially in the large particle size. The insertion of baffles into a fluidized bed system improves the contacting efficiency of gas and particle phases.The effect of rectangular baffles is more significant than the effect of circular baffles on the pressure drop in fluidizing bed.

ان الموضوع الرئيسئ لهذة الدراسة هو لايجاد تاثير الاجزاء الداخلية (الحواجز) المستخدمة في اعمدة التسييل غاز- صلب على الخواص الهيدروديناميكيه لهذه الاعمدة باستخدام عمود زجاجي .(B نوع Geldert دائري وحشوة من الرمل حسب( تصنيف تم الحصول على معلومات تمدد الحشوة في حالة عدم وجود الحواجز ووجود الحواجز حيث استخدم خلال هذه الدراسة نوعين من الحواجز (الشكل الرباعي , الشكل الدائري ) بالاعتماد على الظروف التشغيلية التالية :- سرعة الهواء ,حجم الدقائق ( 205 و424 و775) مايكروميتر, ارتفاع الحشوة (0,1) م وارتفاع العمود المستخدم كان بقطر (1)م. نتائج البحث بينت ان حجم الدقائق توثر على السلوك الهيدرودايناميكي للعملية وخصوصا في الدقائق ذات الحجم الاكبر .


Article
A Quantitative Analysis of the Mixing of Three Solids Different in Density by an Air Fluidized Bed

Loading...
Loading...
Abstract

Three cohesionless free flowing materials of different density were mixed in an air fluidized bed to study the mixing process by calculating performance of mixing index according to Rose equation (1959) and to study the effect of four variables (air velocity, mixing time, particle size of trace component and concentration of trace component) on the mixing index and as well as on mixing performance. It was found that mixing index increases with increasing the air velocity, mixing time and concentration of trace component until the optimum value. Mixing index depends on the magnitude of difference in particle size The first set of experiments (salt then sand then cast iron) give higher mixing index and better performance of mixing than the second set of experiments (sand then salt then cast iron). Box-Willson method was used to minimize number of experiments and to represent the relationship between the variables.


Article
Modelling Pressure Drop to Calculate Conversion of Silicon and Methyl Chloride in a Fluidized bed Reactor
النمذجة الریاضیة لتخلخل الظغط داخل مفاعل الطبقة المتمیعة لحساب نسبة التحول لكل من السلكون والمثیل كلوراید

Author: Ihsan B. Hamawand
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2007 Volume: 25 Issue: 4 Pages: 608-618
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

Three experiments were curried out at different reaction temperatures [ 250, 300,330 oC ], for the reaction of silicon with methyl chloride in a fluidized bed reactor, inorder to evaluate a new predicted model that calculate both conversions of reacted solid(silicon) and reacted gas (methyl chloride) as function of pressure drop along the bed.The reacted gas velocity was selected to be above the minimum fluidizationvelocity [velocity selected 2.6 cm/s, minimum fluidization velocity 1.8 cm/s] for the solidparticles (size used 130 μm). A digital pressure drop measuring device was used at threepoints of the reactor (before and after the distributor and finally 50 cm above thedistributor), to determine the pressure drop along the column, also an online GC wasconnected to the outlet reacted gas to analyze the product.A comparison between the conversions of methyl chloride and silicon calculatedfrom pressure drop data and that detected by the online GC, show a proper agreementwith less than 5 % absolute average error.Two equations [16, 18], derived analytically, were equation [8, 18] used tocalculate the conversion of silicon and methyl chloride as function of pressure drop,equation [16] used to calculate the conversion of silicon as function of conversion ofmethyl chloride.

٣٣٠ ,٣٠٠ , تم اجراء ثلاثة تجارب في ظروف درجات حرارة تفاعل مختلفة تتراوح بين ( ٢٥٠درجة مئوية ) لتفاعل السلكون وغاز الم ثيل كلورايد في مفاعل الطبقة المتميعة وذلك لتقييم موديلرياضي جديد لحساب نسبة التحول لكل من المادة الصلبة المتف اعلة ( السلكون ) والغازالمتفاعل(المثيل كلورايد) وذلك كدالة لتخلخل الظغط في المفاعل.تم اختيار سرعة الغاز المتفاعل اعلى من القيمة الصغرى لسرعة التميع ( السرعة المختارة٢,٦ سم/ثا, القيمة الصغرى لسرعة التميع هي ١,٨ سم /ثا ) نسبة لحجم الدقائق المستعملة ١٣٠مايكرومتر, تم استخدام جهاز رقمي لقياس تخلخل الظغط داخل المفاعل وذلك في ثلاثة نقاط , قبلوبعد موزع الغاز وثالث على ارتفاع ٥٠ سم فوق موزع الغاز كذلك تم ربط جي سي بشكل مباشرمع نواتج التفاعل وذلك لحساب نسبة التحول.تم اجراء مقارنة بين نسبة تحول الغاز المتفاعل ( المثيل كلورايد ) و المادة الصلبة المتفاعلة(السلكون) المحسوبة كدالة لتخلخل الظغط والتي تم الحصول عليها من جهاز ال جي سي , وقداعطت نتائج جيدة مع نسبة ضئيلة للخطا . المعادلتان ( ١٦،١٨ ) هما معادلتان جديدتان تماستنتاجهما من خلال تحليل رياضي بحت , تم استخدام المعادلتان ( ٨،١٨ ) لحساب نسبة تحولالمثيل كلورايد والسلكون كدالة لتخلخل الضغط في المفاعل , والمعادلة ( ١٦ ) لحساب نسبة تحولالسلكون كدالة لنسبة تحول المثيل كلورايد .


Article
A Study of Chaotic Behavior of Heat Transfer In Gas-Solid Fluidized Bed
دراسة التصرف العشوائي لمعامل انتقال الحرارة في برج الطبقة المميعة غاز-صلب

Authors: Jamal Mane'e Al-Rubeai --- Nabeel Majid Aliwi
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2010 Volume: 28 Issue: 10 Pages: 2027-2042
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

Fluidized beds are characterized by high heat transfer rates between thebed and internal surfaces and have uniform temperature distribution that can beachieved in fluidized bed systems. In the same time there is a chaotic behavior ofhydrodynamic and heat transfer in gas-solid fluidized bed.Experimental work was carried out in gas-solid (air – sand) fluidized bed toinvestigate the steady state heat transfer coefficient. The bed column used was(172) mm in diameter and (1000) mm height, fitted with immersed cylindricalheating element of (25.4) mm in diameter. The fluidizing medium was air flowingat different velocities from fixed bed to fluidized bed of (0.006-0.078)m/s, andthree different sizes of fine sand particles were used (i.e. 63, 112, and 145 μm),these average particles diameters were estimated by two methods (Wide andNarrow Range Solids).A comparison have been done with values of the minimum fluidizing velocity thatcalculated analytically, empirical, and which got experimentally. The results showa chaotic behavior of hydrodynamic gas-solid fluidized bed.The heat transfer coefficient and the bed viodage increase with increasing gasfluidizing velocity and the heat transfer coefficient decreases with an increase inparticle diameter.Two empirical correlations are proposed which can calculate wide range solids andnarrow range solids based on experimental data. The Nusselt number presentedwith some dimensionless groups as follows:-For Wide Range Solids Nu = 0.81Re0.94 Pr0.35Where the correlation coefficient (R) was equal to (0.92) and the average absoluterelative error was (12.62 %).For Narrow Range Solids Nu = 0.45Re0.65 Pr0.33Where the correlation coefficient (R) was equal to (0.86) and the average absoluterelative error was (24.2 %).

بامكانية الحصول على معدلات ,(gas-fluidized bed) تتميز الطبقات المميعة بالغازانتقال حرارة عالية بين الطبقة المميعة وسطوح انتقال الحرارة المغمورة داخليا. لذلك تتصفدرجة الحرارة في اعمدة الطبقات المميعة بالانتظام والتي يمكن الحصول عليها قي انظمةالاعمدة. في نفس الوقت خواص التصرف العشوائي الهيدروليكية وانتقال الحرارة في الاعمدة المتميعة غاز- صلب لتحقيق معامل انتقال الحرارة بالحالة المستقرة للطبقة المميعة. عمود التميعيكون بالابعاد ( 172 ملم) قطرا و( 1000 ملم) ارتفاعا ومجهز بمسخن انبوبي افقي مغمور داخل.( حشوة من الرمل وبقطر ( 25.4 ملم) وقد جهز بقدرة كهربائية ( 4446 واط م ٢في وسط التميع يكون جريان الهواء بسرع مختلفة تبداء من الطبقة الثابتة الى الطبقة المميعة,وقد استخدمت دقائق الرمل كحشوة وبثلاثة اقطار مختلفة ( 63,112,145 مايكرومتر), تم حساب.(Wide and Narrow Range Solids) اقطار الحبيبات بطريقتين همالوحظ التصرف العشوائي الهيدروليكي للطبقة المميعة غاز- صلب من خلال حساب اقل سرعةبمعادلات تحليلية وعملية, ومن خلال التجارب المختبرية. (Umf) التميعالنتائج المختبرية تبين ان معامل انتقال الحرارة تزداد مع زيادة سرعة الغازو يتناقص مع الزيادةتزداد بزيادة سرعة الغاز. (Viodage) في قطر الحبيبات. وان الفراغاتوضعتا بالاعتماد على النتائج (Wide and Narrow Range Solids) معادلتان عمليتان لمع بعض المجاميع (Nusselt Number) المختبرية المستحصلة وايضا هذه المعادلتان تربط الاللابعدية كما مبين في المعادلتان ادناه:-Nu = 0.81Re0.94 Pr0.35For Wide Range Solids.( هذه العلاقة التجربيية أعطت معامل ارتباط ( 0.92 ) وخطأ مطلق متوسط مقداره (% 12.62For Narrow Range Solids Nu = 0.45Re0.65 Pr0.33.( هذه العلاقة التجربيية أعطت معامل ارتباط ( 0.86 ) وخطأ مطلق متوسط مقداره (℅ 2


Article
Effect of Fluidized Bed Particle Size on Heat Transfer Coefficient at Different Operating Conditions
تأثير حجم جسيمات الطبقة المميعة على معامل انتقال الحرارة عند ظروف تشغيلية مختلفة

Authors: Ehsan Fadhil Abbas --- Sarah Burhan Izat
Journal: Tikrit Journal of Engineering Sciences مجلة تكريت للعلوم الهندسية ISSN: 1813162X 23127589 Year: 2018 Volume: 25 Issue: 4 Pages: 24-29
Publisher: Tikrit University جامعة تكريت

Loading...
Loading...
Abstract

The aim of this study is to investigate the effect of gas flow velocity, size of sand particles, and the distance between tubes immersed in a fluidized bed on heat transfer coefficient. Experimental tests were conducted on a bundle of copper tubes of (12.5 mm) diameter and (320 mm) length arranged in a matrix (17×9) and immersed in a fluidized bed inside a plastic container. One of the tubes was used as a hot tube with a capacity of (122 W). (25 kg) of sand with three different diameters of sand particles (0.15, 0.3 and 0.6 mm) was used in these tests at ten speeds for gas flow (from 0.16 m/s to 0.516 m/s). The results showed a significant inverse effect of fluidized bed particles diameter on the heat transfer coefficient. Accordingly, the heat transfer coefficient for (0.15mm) diameter sand was found to be higher than that of (0.3 mm) and (0.6 mm) sand by about (3.124) and (6.868) times respectively, in all tests. The results showed good agreement with results from other studies conducted under the same conditions but with different sandparticle size.

تهدف هذه الدراسة الى التحقق من تأثير كل من سرعة الغاز، حجم جسيمات الرمل والمسافة بين االعمدة المغمورة في الطبقة المميعة على معامل انتقال الحرارة. حيث اجريت اختبارات تجريبية على حزمة من االنابيب نحاسية بقطر )5.12 )ملم وطول )320 )ملم ورتبت على شكل مصفوفة )17×9 )مغمورة في الطبقة المميعة داخل حاوية بالستيكية. استخدمت احدى االنابيب كمصدر للحرارة بسعة )122 )واط. استخدمت ثالثة قياسات لجسيمات الرمل )15.0 ،3.0 و6.0 )ملم وبعشر سرع تراوحت مــــن )16.0 الى 516.0 )م/ ثا. اظهرت النتائج بأن تأثير عكسي كبير لقطر جسيمات الرمل في الطبقة المميعة على معامل انتقال الحرارة. وفقا" لذلك، فان معامل انتقال الحرارة عند الرمل بقطر )15.0 )ملم الذي حصل عليه كانت اعلى عما حصل عليه عند )3.0 )ملم و )6.0 )ملم بحوالي )124.3 )و )868.6) مرة على التوالي في جميع االختبارات. تظهر النتائج بانها توافق بشكل جيد مع نتائج لدراسات اخري اجريت تحت نفس الظروف ولكن مع قياسات الرمل مختلفة.


Article
Prediction of Equilibrium Mixing Index and Optimum Mixing Time for Three solid materials in Fluidized Column
التنبؤ بمعامل الخلط عند التوازن وزمن الخلط الامثل لثلاثة مواد صلبة في عمود التميع

Authors: Rasha H. Salman رشا حبيب سلمان --- Ammar S. Abbas عمار صالح عباس --- Abbas H. Sulaymon عباس حميد سليمون
Journal: Al-Khwarizmi Engineering Journal مجلة الخوارزمي الهندسية ISSN: 18181171 23120789 Year: 2010 Volume: 6 Issue: 4 Pages: 21-30
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

Equilibrium and rate of mixing of free flowing solid materials are found using gas fluidized bed. The solid materials were sand (size 0.7 mm), sugar (size0.7 mm) and 15% cast iron used as a tracer. The fluidizing gas was air with velocity ranged from 0.45-0.65 m/s while the mixing time was up to 10 minutes. The mixing index for each experiment was calculated by averaging the results of 10 samples taken from different radial and axial positions in fluidized QVF column 150 mm ID and 900 mm height.
The experimental results were used in solving a mathematical model of mixing rate and mixing index at an equilibrium proposed by Rose. The results show that mixing index increases with increasing air velocity and mixing time until it reaches an optimum value then decrease to an equilibrium value. The results also show the dependency of the mixing index on the particle size of the tracer component.
The statistical analysis of the obtained theoretical mixing index versus the experimental mixing index shows that the standard error is 0.92 % (about 1 %) with the correlation coefficient of 0.9857 and the total residual of 0.002 for the ninth observation of the mixing index (theoretical versus experimental) over 95% confidence level.

تم دراسة معامل الخلط عند الاتزان ومعدل الخلط لمواد حرة الجريان بأستخدام عمود هواء متميع. المواد التي تم خلطها هي الرمل ( قطر الجسيمات 0.7 ملم) والسكر (قطر الجسيمات0.7 ملم) وبرادة الحديد وهي تمثل المادة الكاشفة بتركيز 15% وزنا. معدل سرعة الهواء كان بين 0.45 و 0.65 م/ثا بينما زمن الخلط كان لحد 10 دقائق. معامل الخلط لكل تجربة كان يحسب بأخذ عشرة نماذج ذات مواقع مختلفة قطريا وخطيا من عمود التميع ذو القطر الداخلي 150 ملم وأرتفاعه 900 ملم.تم أستخدام النتائج العملية في حل موديل رياضي لمعدل الخلط ومعامل الخلط عند الأتزان مقترح من قبل Rose. النتائج التجريبية أستعملت لحل موديل رياضي لمعدل الجريان و معامل الخلط عند الاتزان أقترح من قبل .Rose النتائج بينت ان معامل الخلط يزداد بزيادة سرعة الهواء وزمن الخلط حتى يصل للقيمة المثلى ثم ينخفض الى أن يصل للاتزان. نتائج معدل الخلط بينت أعتمادها على مقدار الفرق بين حجم جسيمات المادة الكاشفة. أشار التحليل الإحصائي لكل من معامل الخلط النظري و العملي إلى أن الخطأ المعياري كان 0.92 % (حوالي 1 %) و معامل ارتباط 0.9857 ومجموع المتبقيات لتسع مشاهدات كان 0.002 لمستوى ثقة 95%.


Article
HYDRODESULFURIZATION OF THIOPHENE OVER CO-MO/AL2O3 CATALYST USING FIXED- AND FLUIDIZED-BED REACTORS

Authors: Saad Hanash Ammar --- Abdul Halim A-K Mohammed
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2011 Volume: 17 Issue: 1 Pages: 92-102
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

The present work reports a direct experimental comparison of the catalytic hydrodesulfurization of thiophene over Co-Mo/Al2O3 in fixed- and fluidized-bed reactors under the same conditions. An experimental pilot plant scale was constructed in the laboratories of chemical engineering department, Baghdad University; fixed-bed unit (2.54 cm diameter, and 60cm length) and fluidized-bed unit (diameter of 2.54 cm and 40 cm long with a separation zone of 30 cm long and 12.7 cm diameter). The affecting variables studied in the two systems were reaction temperature of (308 – 460) oC, Liquid hourly space velocity of (2 – 5) hr-1, and catalyst particle size of (0.075-0.5) mm. It was found in both operations that the conversion increases with increasing of reaction temperature, slightly decreases with increasing of liquid hourly space velocity and not affected by particle size. Also a kinetic analysis was performed for thiophene hydrodesulfurization reaction in fixed bed reactor and the results indicate that the reaction kinetics are not affected by pore and film diffusion limitations. The results of the comparison between the two reactors indicate that a low conversion was obtained in a fluidized bed than in fixed bed over the range of conditions studied. The lower conversion can be attributed to the gas that bypasses the bed in the form of bubbles or channels.

تم في هذا البحث دراسة تفاعل هدرجة الثيوفين لازالة الكبريت بوجود عامل مساعد صلب وهو الكوبولت – مولبيديوم المحمل على الالومينا.وذلك في نوعين من المفاعلات وهما المفاعل ذو الطبقة الثابتة والمفاعل ذو الطبقة المميعة. تم بناء منظومتين ريادية مكونة من مفاعل الطبقة الثابتة (ذو قطر 2,54 سم وطول 60 سم) ومفاعل الطبقة المميعة (ذو قطر 2,54 سم مطول 40 سم) الهدف من هذا الدراسة هو مقارنة اداء كل من هذين المفاعلين تحت نفس الضروف من درجة حرارة (308 -460) مه وسرعة حجمية (2-5) سا-1، وحجم جسيمة العامل المساعد (استخدمت ثلاث مديات لحجم جسيمة العامل المساعد:(0,075 – 0,15) ملم, (0,15 – 0,3) ملم, (0,3 – 0,5) ملم, بالاضافة للحجم الاصلي (1 (2 – 5) ملم).اظهرت النتائج في تجارب المفاعل ذو الطبقة الثابتة تأثر التحول كثيرا بتغيير درجة حرارة التفاعل حيث يزداد التحول بزيادة درجة الحرارة ويتأثر قليلا بتغيير السرعة الحجمية ولا يتأثر بتغيير حجم جسيمة العامل الساعد. كذلك ضهرت نتائج مشابهة في تجارب المفاعل ذو الطبقة المميعة. استنتج من هذه النتائج ان حركية تفاعل هدرجة الثيوفين بوجود العامل المساعد الكوبلت - موليبيديوم المحمل على الالومينا لا تتأثر بمقاومة الانتشار الداخلي لجسيمة العامل المساعد (داخل المسامات) وكذلك لا تتأثر بمقاومة الانتشار الخارجي للجسيمة (الانتشار الغشائي).بصورة عامة وبمقارنة الاداء بين المفاعلين, اظهرت النتائج حصول تحول اقل في المفاعل ذو الطبقة المميعة عنه في المفاعل ذو الطبقة الثابتة وذلك بسبب مرور قسم من الغاز المتفاعل الداخل خلال فقاعات او قنوات في طور الفقاعات ولا يمر على العامل المساعد في الطور المستحلب في المفاعل ذو الطبقة المميعة.


Article
Hydrodynamic Studies of Bed Expansion in Liquid Solid Fluidized Bed
دراسة هيدروديناميكية لتمدد الاعمدة المسالة المتكونة من الصلب والسائل

Author: Sawsan A. M. Mohammed
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2010 Volume: 16 Issue: 3 Pages: 5398-5410
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

Expanded bed behavior was modeled by using the Richardson-Zaki correlation between the superficial velocity of the feed stream and the void fraction of the bed at moderate Reynolds number. The terminal velocity expression was developed by introducing two empirical parameters, the effective diameter of the particles and an exponent for the term. The Richardson-Zaki exponent constant (n) was found to vary with the density ratio and diameter ratio . It was noted that when the density ratio is less than one, there is no dense phase at the bottom of the test section. However, for density ratio greater than unity, there exists accelerating or dense regime at the bottom of the test section.

تم في هذا البحث تمثيل تصرف الاعمدة المتمددة باستخدام علاقة ريتشاردسن- زاكي بين السرعة الظاهرية للمجرى الداخل ونسبة الفراغ للعمود في حدود معتدلة من رقم رينولدز. تم استحداث علاقة جديدة للسرعة . النهائية وذلك بادخال مقدارين تجريبيين وهما القطر المؤثر لحبيبات الحشوة ومقداراسي للحدوالنسبة بين قطر الحبيبة لعلاقة ريتشاردسن – زاكي يتغير مع الحد (n)لقد وجد ان المقدار الاسياقل من واحد لم يظهر طور . كذلك تم ملاحظة انه عندما تكون نسبة الكثافة وقطر العمودكثيف في اسفل العمود بينما في حالة كون نسبة الكثافة اكبر من واحد ظهرطور كثيف متسارع في اسفل العمود.


Article
Heat Transfer from an Immersed Heater in Liquid – Liquid – Solid Fluidized Beds
إنتقال الحرارة في أبراج التمييع (سائل- سائل- صلب) لسطح تسخين مغمور

Authors: Asrar A. Al-Obaidy --- Majid I. Abdul-Wahab --- Balasim A. Abid
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2009 Volume: 27 Issue: 10 Pages: 1901-1914
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

Heat transfer from an immersed heating surface to a liquid-solid and liquid-liquidsolid fluidized beds have been studied. The experiments were carried out in a (0.22) m column diameter fitted with an axially mounted cylindrical heater heated electrically. The fluidizing medium was water as the continuous phase and kerosene as the dispersed phase. Low density (Ploymethyl-methacrylate) particles were used. Previouspublished heat transfer correlations, obtained for fluidized beds containing highdensity particles, gave significant deviations compared with the present data. New correlations were developed to predict the heat transfer coefficients in liquid-solid and liquid-liquid-solid fluidized beds. The new correlation is, The heat transfer coefficients obtained from the present work were compared with those estimated from other correlations reported in the literature. The comparison shows a good agreement with the data obtained for the gas-liquid-solid fluidized beds using low-density particles.

يتضمن البحث دراسة عملية إنتقال الحرارة في أبراج التمييع ثلاثية الطور (سائل - سائل - صلب) باستخدام جسيمات صلبة واطئة الكثافة وسطح تسخين مغمور في داخل الطبقة المحيطة، وقد أجريت التجارب في عمود زجاجي ذو قطر داخلي مقداره ( 0.22 ) متر وباستخدام مسخن اسطواني مسخن كهربائياً ومثبت في وسط البرج. تمت دراسة تأثير معدل جريان كل من السائل الأول (الطور المستمر) والسائل الثاني (الطور المنتشر) على معاملات انتقال الحرارة في الأبراج المميعة. كذلك تم حل المعادلات التفاضلية التي تحكم عملية إنتقال الحرارة في الطبقة المميعة باستخدام طريقة الفروق حيث تم إيجاد التوزيع القطري و المحوري لدرجات الحرارة داخل (Finite Difference) المحددةالطبق المميعة وكذلك إيجاد قيم معامل التوصيل الحراري القطري المؤثر.(Thermal Resistances Model) تم تحليل النتائج المستخلصة وفق نموذج المقاومات الحرارية وقد وجد إن المقاومة الداخلية للطبقة المميعة ذات قيمة كبيرة نسبياً في الطبقة الثنائية الطور (سائل- صلب) لكنها تقل عند إدخال الطور الثالث.تم تحليل النتائج إحصائيا لايجاد معاملات انتقال الحرارة Pr Number) ورقم براندتل (Re Number) ورقم رينولدز (Nu Number) بدلالة رقم نسلتللطبقه ثلاثية الطور سائل – سائل – صلب (Solid Holdup) والمحتوى الحجمي للجسيمات الصلبة


Article
EFFECT OF PARTICLE SIZE,FLOW VELOCITY AND

Author: Dr. Tahseen Al-Hattb
Journal: Iraqi journal of mechanical and material engineering المجلة العراقية للهندسة الميكانيكية وهندسة المواد ISSN: 20761819 Year: 2009 Volume: B Issue: first conf./ eng. coll. Pages: 258-268
Publisher: Babylon University جامعة بابل

Loading...
Loading...
Abstract

An experimental study to investigate the effect of the particle size (d) andReynolds number (Re) for different values of heat flux on the heat transfer coefficient(h) in gas-solid fluidized bed was done. In this work three different sizes of sand particles were employed (525,725 and 925mµ ). The fluidizing medium was air at different velocities in the range of (1.9-2.9 m/s). The rig provided with a horizontal heating tube with outer diameter of (3.175cm) was heated eclectically with different power supplies (69,90,120 and 150 W) . The fluidized bed temperature profiles were evaluated axially in the fluidized bedfor different positions. The recording and the monitoring of these measurements weredone by an interface system connected with PC computer. The results show that the temperature distribution decreases with increase particlesize and the heat flux represents as the temperature increases as the air velocitiesincrease . A new empirical correlation was suggested in this study .The correlation predicts the value of (Nup) as a function of both (Rep) and (Fr). All the dimensionlessgroups are determined based on particle diameter . 48.057.0Re0042.023.5Re0738.0ppp+=pp<<<<1675406168Re61FrFrNu ppp

Listing 1 - 10 of 22 << page
of 3
>>
Sort by
Narrow your search

Resource type

article (22)


Language

English (19)

Arabic and English (2)

Arabic (1)


Year
From To Submit

2018 (2)

2017 (1)

2016 (3)

2015 (1)

2014 (1)