Article
Assessment of ISNAG fluorimeter (Total fluorescence measurements at+ 90° & - 90° using four solar cell on each side for 100mm distance at 2mm path length) with well-known fluorescent molecules via CFIA
تقييم مقياس الفلورة ISNAG (القياس للفلورة الكليةعلى +90° و -90°بإستخدام اربعة خلايا شمسية على كل جانب لمسافة100mm وبمسار تشعيع 2mm) مع جزيئات الفلورة المعروفة عن طريق تقنية الحقن الجرياني المستمر

Authors: Nagam S. Turkie نغم شاكر تركي --- Hayder Q. Munshid حيدر قيس منشد
Journal: Iraqi Journal of Science المجلة العراقية للعلوم ISSN: 00672904/23121637 Year: 2018 Volume: 58 Issue: 1B Pages: 240-250
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

Two well-known fluorescent molecules: fluorescein sodium salt (FSS) and 2,7-dichloro fluorescein (DCF) were tried to prove the efficiency, trustability and repeatability of ISNAG fluorimeter by using discrete and continuous flow injection analysis modes.A linear range of 0.002-1 mmol/L for FSS and 0.003-0.7 mmol/L was for DCF, with LOD 0.0018 mmol/L and 0.002 mmol/L for FSS and DCF respectively, were obtained for discrete mode of analysis. While the continuous mode gave a linear range of 0.002-0.7 mmol/L and 0.003-0.5 mmol/L for FSS and DCF respectively, the LOD were 0.0016mmol/L and 0.0018 mmol/L for FSS and DCF respectively. The results were compared with classical method at variable λex for both fluorescent molecules at 95% confidence level. The comparison data shows that ISNAG fluorimeter is the choice with excellent extended detection and a wider applicability.

تم استخدام جزيئتين متفلورة معروفة: ملح فلوريسين الصوديوم(FSS) و 7,2-ثنائي كلوريد الفلورسين(DCF) لإثبات كفاءة وموثوقية وتكرار مقياس الفلورة ISNAG باستخدام تقنية تحليل الحقن الجرياني المنفصلة والمستمرة؛ وتم الحصول على مدى منحني المعايرة 0.002-1 ملي مول/لتر لملح فلورسين الصوديوم و 0.003-0.7 ملي مول/لتر لجزيئة 7,2-ثنائي كلوريد الفلورسين، مع حد الكشف0.0018 ملي مول/لتر و 0.002 ملي مول/لتر لملح فلورسين الصوديوم و جزيئة 7,2-ثنائي كلوريد الفلورسين على التوالي، لطريقة التحليل المنفصل. في حين أعطت الطريقة المستمرة مدى خطي من 0.002-0.7 مليمول/لتر و 0.003-0.5 ملي مول/لتر لملح فلورسين الصوديوم و جزيئة 7,2-ثنائي كلوريد الفلورسين على التوالي، وكان حد الكشف0.0016ملي مول/لتر و 0.0018 ملي مول/لتر لملح فلورسين الصوديوم و جزيئة 7,2-ثنائي كلوريد الفلورسين على التوالي. تم مقارنة النتائج مع الطريقة التقليدية باستخدام λex مختلفة لكلا الجزيئتين المتفلورتين وبحدود ثقة 95%. تظهر نتائج المقارنة ان مقياس الفلورة ISNAG هو الاختيار الامثل ولمدى كشف ممتاز وتطبيق اوسع.


Article
New Approach for Determination of Ciprofloxacin by Quenched Fluorescence of Analytically Interested Species Using Continuous Flow Injection Laser Diode Fluorimeter Analyser
طريقة جديدة لتقدير السايبروفلوكساسين بوساطة تثبيط الفلورة لفصائل تحليلية مهمة وباستخدام محلل الحقن ألجرياني المستمر للفلورة بثنائيات وصلات ليزرية

Authors: Issam M. A. Shakir عصام محمد علي شاكر --- Raed F. Hassan رائد فالح حسن
Journal: Iraqi Journal of Science المجلة العراقية للعلوم ISSN: 00672904/23121637 Year: 2016 Volume: 57 Issue: 1C Pages: 522-533
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

The objective of this study was to establish an accurate, precise, sensitive, simple, fast and reliable method for the determination of ciprofloxacin hydrochloride in pure or in pharmaceutical dosage forms using Homemade instrument fluorimeter continuous flow injection analyser with solid state laser (405 nm) as a source. The method is based upon the fluorescence fluorescein sodium salt and its quenching by ciprofloxacin hydrochloride in aqueous medium. The solutions of standard and the sample were prepared in distilled water. The calibration graph was linear in the concentration range of using (10 - 100) mMol.L-1 ciprofloxacin hydrochloride (r= 0.9891) with relative standard deviation (RSD%) for 3 mMol.L-1 ciprofloxacin HCl solution is lower than 2%(n=6). A comparison was made between the newly developed method of analysis with the quoted value using the standard addition method and no significant difference between the new developed method and the quoted value by the manufacturers companies. This indicates clearly that the new method can be successfully used for the assay of the cited day.

تم استحداث طريقة دقيقة ، بسيطة ، سريعة و حساسة لتقدير السايبروفلوكساسين بشكله النقي وفي مستحضراته الصيدلانية باستخدام جهاز فلوروميتر مصنع محليا بالاقتران مع تقنية الحقن ألجرياني المستمرذو مصدر ليزري بطول موجي (405 nm) تستند الطريقة على تثبيط الفلورة لمادة الفلورسين باستخدام السايبروفلوكساسين كمادة مثبطة للفلورة في الوسط المائي . تم الحصول على خطية تتراوح بين (10 - 100) مللي مول. لتر-1 مع معامل الارتباط r=0.9891 والانحراف القياسي المئوي اقل من 2% لتركيز 3 مللي مول. لتر-1 سايبروفلوكساسين ل(n=6). تم تطبيق الطريقة لثلاثة عقاقير دوائية لتقدير السايبروفلوكساسين. كما قدمت مقارنة بين الطريقة المستحدثة والقيمة الفعالة باستخدام اختبار t- المزدوج لوحظ ان القيمة المحسوبة اقل من القيمة الجدولية ، وعلى هذا الأساس بالإمكان استخدام الطريقة المقترحة للتحليل بالحقن ألجرياني كطريقة بديلة لتقدير السايبروفلوكساسين .