research centers


Search results: Found 7

Listing 1 - 7 of 7
Sort by

Article
Simulation of Galvanic Corrosion for Aluminum, Copper, Iron and Zinc at different pH and temperatures

Author: Ekhlas A. Salman Al-zubidy
Journal: Al-Nahrain Journal of Science مجلة النهرين للعلوم ISSN: (print)26635453,(online)26635461 Year: 2013 Volume: 16 Issue: 3 Pages: 83-91
Publisher: Al-Nahrain University جامعة النهرين

Loading...
Loading...
Abstract

Simple model is proposed to describe galvanic corrosion process. Computer program COR was designed and written in visual basic language to simulate the galvanic corrosion reaction that proposed in the model. Input data metals parameters (aluminum, copper,iron, and zinc) and the environment parameters (pHand temperature) was used in the program designed COR and the results (The electrochemical parameters, corrosion rates, activation energies, and thermodynamic parameters)were calculated and discussed.Simulation computational results are compared with theoretical and experimental data, to ensure that the results of this model are corresponding to the results published in the literature. Both of which show the same characteristics of data distribution. The corrosion rates of iron were higher, followed by copper, zinc and finally aluminum.

حيث تم اقتراح نموذج بسيط لوصف عمليات التأكل الكلفاني وتم تصميم وكتابة برنامج حاسوبي بلغة الفيجول بيسك لمحاكاة تفاعلات التأكل الكلفاني المقترحة في الموديل. وقد تم ايضا إدخال نوعين من البيانات, بيانات عوامل المعادن (الألمنيوم, النحاس, الحديد, الزنك) وبيانات عوامل المحيط (الحرارة, الحامضية) في البرنامج المصمم. وتم الحصول على النتائج (العوامل الكهربائية, معدل التأكل, طاقات التنشيط, عوامل الثرموداينمك) ومناقشتها. نتائج المحاكاة تم مقارنتها مع نتائج نظرية وعملية للتأكد من نتائج الموديل بأنها متوافقة مع النتائج المنشورة. كلا النتائج اظهرت نفس الخصائص. ومن خلال النتائج تبين ان معدل تأكل الحديد عالي متبوعا بالنحاس ثم الزنك واخيرا الألمنيوم.


Article
Corrosion and Galvanic behavior of Copper, Carbon steeland Zinc Couples in (3.5 %wt) Nacl Solution
التأكل والتصرف الغلفاني لمزدوجات النحاس،الحديد والزنك في محلول كلوريدالصوديوم بتركيز(wt 3.5 %)

Authors: Qasim M. Abbas قاسم محمد عباس --- Jamal M. Ali جمال مانع علي
Journal: Al-Khwarizmi Engineering Journal مجلة الخوارزمي الهندسية ISSN: 18181171 23120789 Year: 2009 Volume: 5 Issue: 3 Pages: 60-71
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

The galvanic corrosion of the (Cu - Fe), (Cu - Zn) and (Fe - Zn) couples have been investigated in 3.5% NaCl solution, 40ºC, different velocities (Re = 5000, 10000 and 15000) and different area ratio’s of cathode to anode (AR= 0.5,1 and 2), by using commercial metal pipe (cylindrical tube).The Zero Resistance Ammeter has been used to measure the galvanic current (Ig) and galvanic potential (Eg) with time. The galvanic current density increases with increasing velocity (Re) and the area ratio (AR). The galvanic potential (Eg) is shifted to less negative with increasing velocity (Re) and the area ratio (AR). A statistical relations for the galvanic current density and galvanic potential as a function of (Re). and the area ratio had been created depending on Quasi-Newton method. There is good agreement between experimental and predicted results.

تم دراسة التأكل الكلفاني الناتج من أستخدام مزدوجات المعادن(Cu-Fe),(Cu-Zn),(Fe-Zn) ,في محلول كلوريد الصوديوم بنسبة 3.5 % عند درجة حرارة 40 مο, وبحالات جريان مختلفة (Re=5000,10000,15000) وبأختلاف نسبة مساحة الكاثودالى الانود (AR=0.5,1.0,2.0), وكانت النماذج المستخدمة على الشكل الاسطواني الانبوبي .وتم استخدام (zero resistance ammeter),لقياس التأكل الكلفاني الناتج من ربط معدنين على شكل مزدوج وكذلك قياس جهد التأكل الكلفاني مع الزمن.من خلال التجارب المجراة لوحظ ان التأكل الكلفاني يزداد بزيادة سرعة الجريان (Re.) ونسبة المساحة (AR),بينما جهد التأكل الكلفاني يذهب بألاتجاه الاقل سالبا بزيادة السرعة ونسبة المساحة.تم استنتاج علاقات رياضية تربط بين التأكل الكلفاني وبين الجهد الكلفاني مع السرعة متمثلة ب(Re.) ونسبة المساحة وبالاعتماد على الطرق العددية وبأستخدام البرنامج الاحصائي(Statistica),وكان هناك تطابق واضح بين النتائج العملية والنظرية المستنتجة.


Article
Corrosion Inhibition of Galvanic Couple Copper Alloy/Mild Steel in Cooling Water System

Loading...
Loading...
Abstract

The driving idea for the present work was to combine the effect of polyvinyl alcohol (PVA) as corrosion inhibitor with the distance between the anodic and cathodic elements of the galvanic cell, beside their area ratio, in scope of synergistic suppression of galvanic corrosion on Cu/Fe model couple, using weight loss method. The performance affecting galvanic corrosion process has been tested for three major factors affect the process:1.Four PVA inhibitor concentrations were selected to be (0, 1000, 4000 and 7000 ppm) in simulated cooling water.2.Two cathode: anode area ratios as 1:1 and 2.4:1.3.Two distances apart cathode – anode as 3 and 7 cm. Maximum corrosion inhibition achieved was 86% which indicates that increasing inhibitor concentration leads to decrease dissolution process followed hydrogen evaluation Cu electrode as cathode element in galvanic cell.


Article
Galvanic Corrosion of Dental Alloys and Amalgam in Artificial Saliva Containing Citric Acid
التأكل الكلفاني لسبائك طب الاسنان والحشوة الزئبقیة في اللعاب الصناعي الحاوي على حامضالستریك

Author: Rana A. Majed
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2013 Volume: 31 Issue: 12 Part (A) Engineering Pages: 2200-2310
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

In this work galvanic corrosion potentials and currents were measured usingpolarization curves of some dental alloys (amalgam, Co-Cr-Mo, Ni-Cr-Mo, SS 316L, Ti-6Al-4V alloys) in artificial saliva containing citric acid with three concentrations 3,6 and9 g/l at 37oC. All galvanic corrosion data were measured to coupling of amalgam andother alloys to investigate the galvanic corrosion between filling and other dental devicessuch as partial-denture framework, crowns, bridges, and endodontic instruments.The results of galvanic corrosion show that the coupling between amalgam and Ni-Cr-Mo alloy gives higher galvanic corrosion current than other metallic contact, and thenthe contact between amalgam and Co-Cr-Mo alloy was heavier compared with couplingof SS 316L and Ti-6Al-4V alloy with amalgam. The increasing of corrosion for alloyscontaining chromium due to rapidly converting of Cr6+ to Cr3+ and this phenomenondecreases the concentration of chromium ions at surface and then increases thedissolution of metal atoms, while decreasing of galvanic corrosion of Ti-alloy coupledwith amalgam due to the passive oxide surface layer (TiO2).


Article
Galvanic Corrosion of Carbon Steel –Copper in Aerated H2SO4 Under Agitation Conditions
التآكل الكلفاني للكاربون الفولاذي-نحاس في محلولالكبريتيك وفي ظروف الخلط بوجود الهواء

Authors: Muayad F. Hamad --- Huda D.Abdul Kader --- Basim O. Hasan
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2015 Volume: 33 Issue: 9 Part (A) Engineering Pages: 2107-2118
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

Galvanic and free corrosion experiments on carbon steel-copper couple in 3% H2SO4in the presence of NaCl salts were carried out under different operating conditions. The effect of temperature, agitation speed, and air bubbling (O2 concentration) on the free and galvanic corrosion was studied and discussed. The galvanic corrosion was investigated by both weight loss method and by determining the galvanic currents using zero resistance ammeter (ZRA). The results revealed that increasing temperature leads to increase the galvanic corrosion rate and also the free corrosion rate of each metal. Increasing agitation velocity enhanced the galvanic corrosion rate in a manner depending on temperature. The presence of air bubbling increased the corrosion rate and galvanic currents at low air pumping rate, while, at high pumping rate, air bubbling decreased the corrosion rate.

تم اجراء تجارب على عملية التآكل لكل من الحديد والنحاس بصورة منفردة وعند ربطهما معا في محلول ملحي من حامض الكبريتيك 3% وفي ظروف تشغيلية مختلفة وتم دراسة ومناقشة تأثير درجة الحرارة، سرعة الخلط، تركيز الاوكسجين المذاب على معدل التآكل الكلفاني.تم قياس معدل التآكل الكلفاني بطريقتين فقدان الوزن وقياس تيارات التآكل باستخدام الاميتر الصفري. اثبتت النتائج ان زيادة درجة الحرارة يؤدي الى زيادة معدل التآكل الكلفاني وايضا معدل التآكل لكل معدن على حدى. وكذلك فان زيادة سرعة الخلط يسبب زيادة في معدل التآكل الكلفاني اعتمادا على درجة الحرارة.ان زيادة نسبة الاوكسجين المذاب يسبب زيادة في معدل التآكل وكذلك تيارات التآكل الكلفاني عند معدل ضخ الهواء الواطىء بينما زيادة معدل ضخ الهواء اكثر يسبب تقليل في معدل التآكل عند سرع الخلط العالية.


Article
The Influence of Area Ratio, Temperature and Rotational Speed on Galvanic corrosion between Law Alloy Steel–Copper couple in 4%NaCl Solution

Author: S.A. Jafar
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2017 Volume: 35 Issue: 6 Part (A) Engineering Pages: 617-623
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

Galvanic corrosion between law alloy steel and copper couple in 4 % NaCl solution was studied and the effect of some variable were investigated. The effect of area ratio, temperature and rotational speed through the electrolyte have been investigated. An increase in galvanic current was observed when we increased the area ratio of law alloy steel to copper and the galvanic potential moved to extra negative direction. When the temperature of solution increase led to increase the galvanic current and shifting the galvanic potential to extra negative direction. The galvanic current rises clearly with increasing of rotational velocity of agitator with shifting the galvanic potential to extra positive due to mass transfer control the process. In addition, increase the diffusion of oxygen from bulk of electrolyte to the metals surface.


Article
Analysis of Galvanic Corrosion under Mass Transfer Controlled Conditions

Authors: Basim O. Hasan --- Qasim. J.M Slaiman
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2007 Volume: 13 Issue: 3 Pages: 1623-1636
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

Because of practical importance of protecting industrial equipments from galvanic corrosion, the need arises to analyze the effects of variables, such as temperature, velocity, and area fraction of metals on galvanic corrosion in systems under mass transfer control as in seawater (pH=7). For these reasons the galvanic corrosion of Fe-Zn is analyzed to study the influence of Reynolds number, temperature, and area fraction on the galvanic corrosion rates and galvanic corrosion potential under mass transfer control.It is found that galvanic corrosion rate of more active metal (Zn) is increased with Reynolds number while the corrosion rate of more noble metal (Fe) is slightly increased with Re depending on the galvanic potential that depends on the area fraction. Increasing Reynolds number shifts the galvanic potential to more positive values. Also increasing temperature leads to shift the corrosion potential to more negative values and to change the corrosion rate of more active metal (Zn) depending on two parameters oxygen solubility and oxygen diffusivity. As area fraction of more active metal (Zn) increased the galvanic potential is shifted to the negative anodic direction while the corrosion rate for more noble metal is decreased.

بسبب الاهمية التطبيقية لحماية المعدات الصناعية من التاكل الغلفاني ظهرت الحاجة لدراسة وتحليل تأثير بعض العوامل مثل درجة الحرارة وسرعة السائل ومساحة الكاثود والانود على التاكل الغلفاني في الانظمة التي تكون تحت سيطرة انتقال الكتلة(pH=7) كما في ماء البحر.تمت دراسة التاكل الغلفاني لمعدني الحديد والخارصين لمعرفة تاثير عدد رينولد (او السرعة) ودرجة الحرارة ونسبة المساحة في ظروف سيطرة انتقال الكتلة. أظهرت النتائج ان زيادة عدد رينولد يؤدي الى زيادة تأكل المعدن الفعال الانود (Zn ) بصورة رئيسية ويؤثر قليلا على المعدن الاقل فعالية (الكاثودFe) وحسب جهد التاكل الذي يعتمد على نسبة المساحة بين المعدنين. زيادة عدد رينولد يؤدي الى زيادة جهد التاكل الغلفاني بالاتجاه الموجب و زيادة درجة الحرارة تؤدي الى تقليل معدل التاكل الغلفاني وتقليل جهد التاكل الغلفاني(ازاحته بالاتجاه السالب) وازاحته بالاتجاه السالب اما زيادة مساحة المعدن الفعال (Zn) تؤدي الى تقليل الجهد الغلفاني وتقليل تاكل المعدن الاقل فعالية (Fe).

Listing 1 - 7 of 7
Sort by
Narrow your search

Resource type

article (7)


Language

English (6)

Arabic and English (1)


Year
From To Submit

2017 (1)

2015 (1)

2013 (3)

2009 (1)

2007 (1)