research centers


Search results: Found 21

Listing 1 - 10 of 21 << page
of 3
>>
Sort by

Article
Effect of Harmonics on a Solid-Rotor Induction Motor

Authors: Ahmed Th. Radhi --- Ali M. Saleh
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2006 Volume: 12 Issue: 1 Pages: 199-217
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

The paper records a study of an investigating the performance of a solid-rotor induction motor with a rectilinear inverter excitation to identify the effects of the associated time harmonics. The performance is determined experimentally by using a stator of a three-phase laboratory induction motor that is fitted with a solid-steel rotor and compared with the theoretical model developed which uses the Fourier components of the supply voltage waveform. Final conclusions are drawn from comparing motor performances with sinusoidal and inverter excitations. An equivalent circuit model is developed to determine the harmonic currents. The development of the theoretical model make use of the results of existing field analyses. Harmonic currents and other performance details including the possible interactions between the co-existing harmonics are determined and discussed. The measured values of torque, input current and power over full speed range with the two types of excitation are presented, and compared with the theoretical values. The waveforms of current, phase and line voltages are analyzed experimentally and compared with simulation results. The theoretical results correlate well with measured results and the significant harmonic effects are identified.

تسجل هذه الأطروحة دراسة لبحث أداء المحرك الحثي من النوع ذو الدوار الصلب (Solid-Rotor) بتغذيته من خلال فولتية العاكس للتعرف على التأثير المرافق للتوافقيات الموجودة ضمن فولتية العاكس. لقد تم استنتاج الأداء عمليا باستخدام محرك حثي الجزء الثابت له يعمل مع دوار من نوع الصلب وقورن مع النموذج النظري الذي تم باستخدام مركبات فورير (Fourier Components) لموجة فولتية العاكس. الاستنتاجات النهائية قد تمت بمقارنة أداء المحرك باستخدام فولتية جيبيه وفولتية العاكس. لقد تم تطوير نموذج للدائرة المكافئة لإيجاد تيارات التوافقيات. أن تطوير هذا النموذج النظري تم باستخدام نتائج تحليل المجالات في الدوار الصلب. تيارات التوافقيات وتفاصيل أداء المحرك بما يشمل التداخلات المحتملة بين التوافقيات المتولدة سوية تم استنتاجها ومناقشتها. القراءات المقاسة لكل من التيار والعزم والقدرة على كل مدى السرعة ولكلا النوعين من التغذية، قد تم عرضها وقورنت مع النتائج والقيم النظرية. موجة التيار وموجة فولتية الطور والخط تم تحليلها مختبريا وقورنت مع النتائج النظرية. النتائج النظرية اتفقت بشكل جيد مع القيم العملية وتم تحديد التأثيرات الأكثر أهمية لهذه التوافقيات.

Keywords

Harmonics --- induction motor


Article
Harmonics Study of 3-Phase Space Vector PWM Inverter

Authors: Ahamed Assad Hadi --- Majid K. Al-Khatat
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2011 Volume: 29 Issue: 12 Pages: 2439-2455
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

This paper proposes the modeling ,implementation and simulation of three phase induction motor driver, using voltage- fed space vector pulse width modulation technique (SVPWM).The sources of total harmonics (i.e. total effective harmonics,inter-harmonics,and sub-harmonics) and how it affects on drive system and their affects on the supply power network are studied. A developed formula of total harmonics distortion factor (THD) including ,inter -harmonic, and sub- harmonic has been introduced while in the previous studies are neglected. The effect of inter-harmonics and sub-harmonics on the performance parameter of total harmonics distortion factor , switching losses factor (SLF) and quality factor (QF) has been deduced. Modeling , and simulation of the system using PSIM software are also presented. All results are obtained by studying the waveforms of voltage and current at the source and load sides with different speeds of motor drive. The simulation and experimental result are consistent with theoretical studies and excellent , they indicate that the model is accurate and practicable.


Article
Performance Analysis of Inverter-Fed Single-Phase Induction Motor

Authors: Amer O. Kareem --- Ali M. Saleh
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2009 Volume: 15 Issue: 1 Pages: 3506-3520
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

This study investigates the effects of the presences of harmonics in the exciting voltage when using a dc/ac inverter on the performance of a single-phase induction motor, the investigation includes theoretical and experimental parts and together with performance comparison of the motor with the nominal sinusoidal input voltage. The computed performance of the motor depend on the theoretical equivalent circuits which are modified to take into account the existence of harmonics in the inverter output to compute the performance at each harmonic order. It conclude from the analysis that the pulsating torque is inherent in single-phase induction motor even when supplied from a sinusoidal voltage source. Particular attention has been devoted to the pulsating torque when the motor is supplied from an inverter and the most important pulsations have been identified. The comparisons of simulation and measured results show good correlation between them in addition that it highlight and identify the cumulative effects of harmonics on the motor performance.

يتناول البحث دراسة تأثيرات المحتوى التوافقي للفولتية المحتثة من عاكسة (dc/ac Inverter) على أداء محرك حثي أحادي الطور، يتألف البحث من أجزاء نظرية و عملية تقارن أداء المحرك باستخدام فولتية جيبية و فولتية العاكس. تم استخدام مبدأالدوائر المكافئة في عملية حساب الأداء النظري للمحرك، حيث تمت عملية تعديل على هذه الدوائر لكي تتناسب مع حساب الأداء لكل مركبات التوافقيات(Harmonic Order).إن الاستنتاج التحليلي أكد تأصل وجود العزم النبضي في المحرك الحثي أحادي الطور حتى عند تغذية المحرك بمصدر جيبي الفولتية. تم تكريس الاهتمام بالعزم النبضي للمحرك المجهز من العاكسة مع دراسة و تعريف (Pulsation) الأهم في هذه الحالة. إن مقارنة النتائج النظرية و القيم العملية بينت اتفاق جيد بالإضافة الى تركيز الاهتمام و تحديد تأثيرات تراكم التوافقيات الأكثر أهمية على أداء المحرك.


Article
Harmonics Distribution in Electrical Power System Containing Static Var Compensator
توزیع التوافقیات في منظومات القدرة الكھربائیة التي تحتوي على معوضات أستاتكیكیة للقدرة غیر الفعالة

Author: Mohammed K. Edan
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2009 Volume: 27 Issue: 3 Pages: 559-572
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

This research presents a harmonic analysis of the power system with static VARcompensator. The model is formed by parallel combination of Thyristor ControlReactor (TCR) with a bank of capacitor .This model based on use of harmonicswitching functions and this harmonic model is completely general and can beinterpreted as a harmonic admittance equivalent. It is suitable for directincorporation into the harmonic domain frame of reference where it combineseasily with frequency dependent admittances of the transmission network, andwith other linearised component. This approach leads to efficient iterative solutionof power networks containing TCR. The general operating condition correspondsto a case, when the switching instant of thyristor valve are function of networknodal voltage conditions, this applies to both thyristor turn-on and turn-offinstants. In such situation the voltage zero crossing points calculated with goodaccuracy at each iterative step, are used to update the TCR switching function.Newton-Raphson technique is used to determine the zero-crossing points.

يقدم هذا البحث تحليل للتوافقيات في منظومة القدرة المزودة بمعوض استاتيكي ل لقدرة.الانموذج مكون من مسيطر الثايرستور على المفاعلة مربوط على التوازي مع متسعة .هذاالانموذج يعتمد على استخدام دالة الفتح والغلق للتوافقيات . الانموذج عام يمكن تحويله الىمسايرة مكافئة للتوافقيات وبالامكان دمجهامباشرة في حيز التوافقيات مع السايرة المعتمدة علىالتردد لشبكات النقل والاجزاء الاخرى .هذا التركيب يقود الى حل تكراري فعال للشبكات التيتحتوي على مسيطر الثايرستور على المفاعلة .شروط العمل العامة تعتمدعلى الحالة، لحضاتالغلق و الفتح للثايروسترتعتمد على شروط فولتية العقدة للشبكة .في هذه الحالة نقاط تق اطعالفولتية مع الصفر تحسب بدقة عند كل تكرار وهذه القيمة تستخدم لتحديث دالة الغلق والفتحالى مسيطر الثايرستور على المفاعلة .استخدمت تقنية نيوتن رافسن لحساب نقاط تقاطعالفولتية مع الصفر.


Article
A NEW DESIGN METHOD OF OUTPUT FILTER FOR SPACE VECTOR PWM FED INDUCTION MOTOR
طريقة تصميم جديده لمرشح خارجي لعاكس مضمن عرض النبضة للمتجه الفضائي يغذي محرك حثي ثلاثي الطور

Authors: Fadhil A. Hassan --- Ola Hussian --- Dr. Majid K. Al-Khatat
Journal: Al-Qadisiyah Journal for Engineering Sciences مجلة القادسية للعلوم الهندسية ISSN: 19984456 Year: 2011 Volume: 4 Issue: 2 Pages: 122-133
Publisher: Al-Qadisiyah University جامعة القادسية

Loading...
Loading...
Abstract

This paper proposes a new simplified method for design, simulation, implementation, and obtaining optimum value of ac output filter to the SVPWM inverter fed induction motor using the benefit of PSIM program is developed. Also a complex mathematical equations and transfer functions are not desirable. The L-C filter cancels all harmonics and a real pure sinusoidal output voltage and current is obtained. Due to the flexibility of PSIM software, the values of L-C combination are obtained by trial and error method. The advantage of this method, it can vary the values of inductor and capacitor until the value of desired outcome is obtained. Experimental and simulation results have verified the superior performance and the effectiveness in reduction the harmonics of the proposed filter.

يقدم هذا البحث طريقة جديدة ومبسطة قد طورت التصميم و التمثيل و التطبيق وللحصول على افضل وامثل قيمة للمرشح الخارجي (output filter ) لعاكس مضمن عرض النبضة للمتجه الفضائي يغذي محرك حثي ثلاثي الطور باستخدام فائدة البرنامج (PSIM).كذلك هذه الطريقه لا تحتاج الى معادلات رياضيه ودوال انتقاليه معقده.مرشح الترددات (L-C Filter) يقضي على كل التوافقيات ويحصل على موجة جيبية نقية وحقيقية للفولتية الخارجية والتيار. من خلال مرونة البرنامج PSIM , القيمة لمركبة LC ممكن الحصول عليها بواسطة طريقة التجربة والخطا (Trial and Error) من فوائد هذة الطريقة اذ يمكن تغير القيم لكل من الملف و المتسعة حتى تحصل على النتيجة المرغوب فيها. أن نتائج الأختبار العملي والتمثيل الرياضي أثبتت وبشكل واضح الأداء الفائق والفاعلية الكبيرة في تخفيض التوافقيات للمرشح المقدم.


Article
Implementation OfThe SPWM Technique For Harmonic Elimination Using Microcontroller
تنفيذ تقنيةSPWM لحذف التوافقيات باستخدام المسيطر المصغّر

Author: Kamil G. Salih/ كامل غاوي صالح
Journal: AL Rafdain Engineering Journal مجلة هندسة الرافدين ISSN: 18130526 Year: 2013 Volume: 21 Issue: 6 Pages: 31-45
Publisher: Mosul University جامعة الموصل

Loading...
Loading...
Abstract

Abstract Elimination of load harmonics can be achieved by either filtration of selected harmonics or the use of pulse-width modulation PWM technique. Many PWM techniques are developed, but the most commonly used in industrial applications is the SPWM technique where the distortion factor DF (one of the most important performance parameters of the quality and efficiency of a lot of the electronic devices) is significantly reduced. In this paper,the SPWM technique for harmonic elimination (HE)is implemented using 8051 microcontroller and the well known MATLAB software. The result is tested on a prototype inverter which was designed since 1998. This method is based on the analysis of Fourier series and Fourier coefficients of the required SPWM output voltage waveform. In this paper, the odd function technique with three and five pulses per half cycle to generate the required SPWM control signals is achieved. The basic flow chart of the control program, samples of the experimental results as well as an appendix illustrating the complete source code programs (INV1) and (INV2) in an assembly language of 8051 microcontroller are given. Key words :Harmonics elimination, PWM,Microcontroller, Inverter .

الخلاصةيتحقق حذف التوافقيات للحمل الكهربائي إما بواسطة المرشحات الالكترونية أو باستخدام تقنية تضمين عرض الموجة PWM .هنالك عدة تقنيات لتضمين عرض الموجة بيد أن الأكثر شيوعا" واستخداما" في التطبيقات الصناعية هي تقنية SPWMحيث يقل عامل الضوضاء (DF) (الذي يعتبر من أهم العوامل التي تحدد كفاءة وجودة كثير من الأجهزة الالكترونية) فيها بشكل كبير . تم في هذا البحث تنفيذ الطريقة الأكثر شيوعا" لحذف التوافقيات باستخدام المسيطر المصغّر (8051) ونظام الرياضيات المعروف (MATLAB) وفحص أداء هذه الطريقة على أنموذج للعاكسة الالكترونية التي تم تصنيعها منذ عام 1998 .تعتمد هذه الطريقة على التحليل الرياضي وذلك بإيجاد متوالية Fourier وحساب المعاملات الخاصة بها لموجة فولتية الإخراج المطلوبة. تم في هذا ألبحث تحقيق تقنية (Odd function) لثلاث وخمس نبضات في نصف دورة لتوليد إشارات التضمين والتحكم اللازمة (SPWM) .وأخيرا جرى عرض المخطط الانسيابي الأساسي لبرنامج التحكمونماذج من النتائج المختبرية إضافة إلى ملحق يوضّح تفصيلياً برنامجي الأساس ( INV1&INV2) بلغة التجميع للمسيطر المصغّر .8051


Article
Study the Effect of Serial Inductance on Reducing the Current Harmonic Distortion of Three-Phase Bridge Rectifier

Authors: Ghanim Thiab Hasan --- Muhamad Omar Salih --- Ali Hlal Mutlaq
Journal: Tikrit Journal of Engineering Sciences مجلة تكريت للعلوم الهندسية ISSN: 1813162X 23127589 Year: 2018 Volume: 25 Issue: 3 Pages: 1-4
Publisher: Tikrit University جامعة تكريت

Loading...
Loading...
Abstract

The aim of this paper is to analyze the influence of adding serial inductance in AC side of the ‎‎3ph -6 pulse bridge rectifier on the reduction of harmonic distortion rate. A simulated model ‎with serial inductance was analyzed. The 3-phase 6-pulse diode bridge rectifier was chosen ‎because it corresponds to the operation of the 6-pulse thyristor bridge rectifier at maximum ‎load (while keeping the angle α = 0). Both the total harmonic distortion (THDi) and the ‎power factor (PF) for the circuit have been measured. The results obtained of the THDi has ‎been recorded for four values of serial inductance and results was compared with the (IEEE 519-1992) standard. Comparison results indicates ‎that for values of inductive reactance (Xi) up to 67% cause a reduction of THDi which is above the standard values, while for (Xi) more than 67% cause a reduction in THDi within the acceptable standard level. Analyzing of results prove that the adding of serial inductance at the AC ‎side leads to good reduction in harmonic distortion rate, but with some reduction in power ‎factor value, which results in some energy losses.


Article
POWER FACTOR IMPROVMENT FOR CEMENT FACTORY
تعديل معامل القدرة في مصنع اسمنت

Author: Tawfeeq Enad Abdulabbas
Journal: Journal of Engineering and Sustainable Development مجلة الهندسة والتنمية المستدامة ISSN: 25200917 Year: 2018 Volume: 22 Issue: 5 Pages: 83-100
Publisher: Al-Mustansyriah University الجامعة المستنصرية

Loading...
Loading...
Abstract

The cement plant contains nonlinear loads and significant harmonic sources (kiln rectifiers drives) that can flow through the plant, therefore it is necessary to treat both of the harmonics and the power factor reduction problems to improve the system efficiency, power system quality and decrease losses. This work examines the technical feasibility of designing a capacitor filter bank according the level of harmonics in the network, and also achieving improvement for the power factor (Static Compensators).The methodology used for this work is based on the practical measurements of real time operation of the electrical parameters of cement industrial facility, and then the whole system has been modelled (using MATLAB/SIMULINK). A MATLAB code is used to calculate the harmonic filter components required to design the capacitor filter to be then inserted in the simulated model in order to cross check the load operation after insertion filter component via enabling different mode of operations. Also system performance calculations are made after including the harmonic filters is to ensure the operations safety.


Article
Analysis and Design of Passive Filters to Reduce Line Current Harmonics for Controlled Rectifiers
تحليل وتصميم المرشحات غير الفعالة لتقليل توافقيات تيار الخط في المقومات المحكومة

Authors: Hussein I.Zynal أ.م.د حسين ابزار زينل --- Bashar A.Fadeel بشار عباس فضيل
Journal: AL Rafdain Engineering Journal مجلة هندسة الرافدين ISSN: 18130526 Year: 2014 Volume: 22 Issue: 1 Pages: 80-96
Publisher: Mosul University جامعة الموصل

Loading...
Loading...
Abstract

Many researchers have sought to use different methods to reduce harmonicsin the input current wave of the rectifier, In this study the method of passive filterconnections are used, which is the most commonly used method. The filters that havebeen used in this study are connected in parallel (shunt) with the rectifier. Where theidea of these filters to provide a path with a very low impedance to the harmonics of thecurrent. These filters must be capable of withstanding rated voltage of the system. Inthis study two types of passive filters are explained and used (Single tuned filter andSecond order high-pass filters). Also mathematical analysis of these types of filters andwaves are given. Filters were designed at several values of the firing angles of therectifier.

سعى العديد من الباحثين إلى استخدام طرائق مختلفة لتقليل التوافقيات الظاهرة في موجة تيار الإدخالل لم ق و م ا لق ن ط ر ي , و ف ي ه ذ ه ا لد ر اس ة ت م اس ت خ د ام ط ر ي ق ة ر ب ط ا لم ر ش ح ات غ ي ر ا لف ع ا لة و ا لت ي ت ع د م ن أك ث ر ا لط ر ائ ق ش ي و ع اواستخداما. المرشحات غير الفعالة التي تم استخدامها في هذه الدراسة هي التي تربط على التوازي مع المقوم القنطري,إذ إن فكرة عمل هذه المرشحات هي توفير مسار ذي ممانعة واطئة جدا لتوافقيات التيار ويجب أن يكون هذا النوع منالمرشحات قادرآ على تحمل الفولتية المقننة للنظام. في هذه الدراسة سيتم عرض نوعين من المرشحات غير الفعالةالمستخدمة )مرشح أحادي التنغيم, مرشح ثنائي المرتبة ذو إمرار عال( , إذ سيتم شرح مبدأ عمل هذه المرشحات معالتحليل الرياضي لهذه المرشحات والتحليل الرياضي للموجات غير الجيبية. وسيتم تصميم المرشحات عند زوايا قدحمختلفة. ودراسة الإجهاد المسلط على عناصر المرشح وعلى المرشح بالكامل عند كل حالات التصميم


Article
Analysis and Simulation of Shunt Active Power Filter For Harmonic Cancellation of Non Linear Loads
تحليل ومحاكاة المرشحات الفعالة المربوطة على التوازي لالغاء التوافقيات المتولدة من الاحمال الغير خطية

Author: Ahmed M. Mohammed
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2010 Volume: 28 Issue: 16 Pages: 5188-5199
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

Use of nonlinear loads, such as power converters, power sources,uninterruptible power supply (UPS) units, and arc devices like electric furnaces and fluorescent lamps and large adjustable speed motor drives, is expected to grow rapidly. All of these loads inject harmonic currents and reactive power into the power system. This paper presents a study and simulation of a three phase active power filter. A multilevel PWM inverter is used with current control technique. The proposed control system is very simple and therefore practicalimplementation of active power filters is available. The presented system is able to compensating current harmonics, reactive power and unbalance current of non linear loads. The total harmonic distortion is calculated for deferent load before and after filtering with deferent type of filter. A comparison is made between passive filter and active.The results have been obtained using software called PSIM, which hasdemonstrated its reliability for almost 10 years of simulations, which have been approved with real experimental results.

ان كثرة استخدام الاحمال الغير خطية في حياتنا العامة مثل دوائر توحيد الموجة , مصادر الطاقة الاحتياطية ودوائر السيطرة على سرعة المحركات الكهربائية... الخ, قد ادى الى كثرة التوافقيات في التيارالمسحوب من منظومة الشبكة الكهربائية الوطنية . وعلى هذا الاساس اصبح من الضروري استخدام مرشحات نشيطة بدلا من المرشحات التقليدية التي كانت تستخدم سابقا للتخلص من هذه التوافقيات. في هذا البحث تم تحليل ومحاكاة مرشح فعال باستخدام تقنية مولد موجات توافقية تساوي الموجات التوافقية المتولدة من الاحمال الغير خطية بالمقدار وتعاكسها بالاتجاه (اي فرق طور = 180درجة) وضخ هذه التوفقيات داخل منظومة الطاقة الوطنية لكي نتخلص من هذهالتوافقيات وايضا تحسين عامل القدرة. في هذا البحث تم حساب التشويه الكلي للموجة لمجموعة من الاحمال الغير خطية قبل وبعد استخدام المرشح (THD) بسبب التوافقيات الفعال واجراء مقارنة بين عمل انواع المرشحات الفعالة والغير فعالة. في تحليل ومحاكات المرشح الفعال (PSIM) في هذا البحث تم استخدام برنامج والحصول على النتائج المطلوبة حيث ان هذا البرنامج يعتبر من البرامج الموثوقة والمعتمدة على مدى 10 سنوات من المقارنات بين النتائج المستحصلة من البرنامج والنتائج العملية.

Listing 1 - 10 of 21 << page
of 3
>>
Sort by
Narrow your search

Resource type

article (21)


Language

English (17)

Arabic (2)

Arabic and English (2)


Year
From To Submit

2018 (3)

2017 (2)

2016 (1)

2015 (3)

2014 (1)

More...