Prevention of Scale Formation in Heat Exchanger Pipesby Using Magnetic Field

Authors: Jassim M. Al-Kyayyat --- Abbas H. Sulaymon عباس حميد
Journal: Iraqi Journal of Chemical and Petroleum Engineering المجلة العراقية للهندسة الكيمياوية وهندسة النفط ISSN: 19974884/E26180707 Year: 2007 Volume: 8 Issue: 4 Pages: 39-44
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

The possibility of using the magnetic field technique in prevention of forming scales in heat exchangers pipes using hard water in heat transfer processes, also the studying the effective and controllable parameters on the mechanism of scale formation.The new designed heat exchanger experimental system was used after carrying out the basic process designs of the system. This system was used to study the effect of the temperature (40-90 °C) and water flow rate (0.6-1.2 L/min) on the total hardness with time as a function of precipitation of hardness salts from water and scale formation.Different magnetic field designs in the heat exchanger experimental system were used to study the effect of magnetic field design and strength (200-500 Gauss) on the total hardness with time as a function of precipitation of hardness saltsfrom water and scale formation.


Article
PRESSURE DROP CONSTRAINTS IN SLUDGE DOUBLE-PIPE HEAT EXCHANGER DESIGN
محددات فرق الضغط في تصميم مبادلات الحمأة الحرارية نوع الأنبوب المزدوج

Author: Dr. Amer D. Zmat د. عامر دحام زماط
Journal: Al-Qadisiyah Journal for Engineering Sciences مجلة القادسية للعلوم الهندسية ISSN: 19984456 Year: 2011 Volume: 4 Issue: 1 Pages: 472-482
Publisher: Al-Qadisiyah University جامعة القادسية

Loading...
Loading...
Abstract

Recent years have witnessed a rapid development in the understanding of heat exchangers design. Those developments have justified the use of a global minimum allowable temperature approach under which the heat transfer area of the heat exchanger is minimized. Values of the allowable pressure drops of streams of exchangers are specified to calculate film heat-transfer coefficients of streams and heat-transfer area. By coupling this with the understanding of what dictates the energy consumption, it is possible to determine the trade-off between the heat exchanger capital cost and energy cost prior to design work. Pressure drop is an important issue in the design of a heat exchanger. Pumps and (or) compressors must be installed to overcome pressure losses when streams flow through heat exchangers. The total cost for a system of pumps and compressors consists of the purchase cost of equipments and the electricity cost to run these equipments. This cost could occupy a significant part of the overall cost for a heat exchanger. Therefore, the pressure drop aspect should be considered together with the costs of heat exchanger area.This paper demonstrates how pressure drop is considered in the context of a sludge double-pipe heat exchanger design. A relationship between heat transfer coefficient and heat exchanger pressure drop was determined and its capital cost implications were assessed.

شهدت السنوات الأخيرة تطور سريع في تصاميم المبادلات الحرارية. تميزت معظمها باستخدامها مفهوم أدنى فرق في درجات الحرارة للحصول على اقل مساحة انتقال حراري. وطبقا لتلك الطريقة يتم تحديد قيم فرق الضغط المقبول لحساب معامل انتقال الحرارة ومساحة الانتقال الحراري من خلال ربط هذه الطريقة مع أسلوب حساب استهلاك الطاقة في المبادلات الحرارية ويمكن إجراء المفاضلة بين كلفة المبادل الحراري وكلفة الطاقة اللازمة لتشغيله قبل مرحلة التصاميم التفصيلية. وحيث أن فرق الضغط في المبادلات الحرارية ينعكس على كلف ملموسة في المبادلات الحرارية تتمثل بكلف المضخات والدافعات وكلف الطاقة اللازمة لتشغيل تلك المضخات والدافعات، فان دراسة تلك الكلف نسبة إلى كلفة المبادل الحراري تعتبر أمر ضروري ومهم.يستعرض هذا البحث كيفية تضمين فرق الضغط في مبادلات الأنبوب المزدوج المستخدم لتسخين الحمأة في أحواض الهضم ضمن مرحلة التصميم من خلال إيجاد علاقة بين معامل انتقال الحرارة وفرق الضغط وتقييم انعكاس ذلك على الكلفة المثالية للمبادل الحراري.


Article
Experimental and Numerical Investigation to Evaluate the Performance of Helical Coiled Tube Heat Exchanger
تحقيق عملي وعددي لتقييم أداء مبادل حراري حلزوني الأنبوب

Authors: Qasim Saleh Mahdi قاسم صالح مهدي --- Sahar Abdul Fattah سحر عبد الفتاح عبود --- Firas juma Abd فراس جمعة
Journal: Journal of Engineering and Sustainable Development مجلة الهندسة والتنمية المستدامة ISSN: 25200917 Year: 2014 Volume: 18 Issue: 4 Pages: 89-110
Publisher: Al-Mustansyriah University الجامعة المستنصرية

Loading...
Loading...
Abstract

Experimental and Numerical investigation of heat transfer enhancement in shell and helical coil tube heat exchanger is carried out in the present work. Experimental work included design of helical coil heat exchanger with different curvature ratio and coil pitch. Three helical coil tube heat exchangers with different curvature ratio (D/d) 12/1, 15/1, 17/1, 20/1 and 24/1 are studied to choose the optimum one. Four helical coils with different coil pitch 1.8d, 2d, 3d, and 5d has been chosen to study the effect of coil pitch on heat transfer coefficient. From experimental results the curvature ratio 17/1 gives optimum helical coil. Experimental results show increases of coil pitch lead to increasing in heat transfer coefficient of the shell side and indicate that convective heat transfer is increased by Reynolds number as well as Dean Number.Numerical geometry has been built using ansys fluent package 14.1 commercial copy with solid work and gambit software program depends on the optimum design . Numerical results show that the temperature decreases along the coil and the temperature difference effect on heat flow along helical coiled. Also there is different in temperature between each turn. Empirical correlation has been developed to predict Nusselt number at helical coil. The comparison between numerical and experimental results show good agreement.

التحقيق التجريبي والعددي لتحسين انتقال الحرارة لمبادل حراري مكون من أسطوانة (القشرة) وأنبوب حلزوني نفذت في هذا العمل .تضمن العمل التجريبي تصميم مبادل حراري حلزوني مع أفضل نسبة تقوس ودرجة حلزنة. خمسه مبادلات حرارية حلزونية مع نسب تقوس مختلفة24/1, 20/1, 17/1, 15/1, 12/1 درست لاختيار أفضل مبادل حراري حلزوني. أربعة مبادلات حرارية مع درجات حلزنة مختلفة (1.8d, 2d, 3d, 5d) صممت لدراسة تأثير درجة الحلزنة على معامل انتقال الحرارة. الملف الحلزوني الذي له نسبة تقوس17/1 اختير كأفضل ملف حلزوني طبقا للنتائج العملية. زيادة درجة الحلزنة تؤدي إلى زيادة معامل انتقال الحرارة في (القشرة). النتائج العملية تشير إلى إن انتقال الحرارة يزداد بزيادة رقم رينولد بالإضافة إلى رقم ديان.أما الجانب العددي فقد تم استخدام برنامج ansys fluent في رسم الشكل باستخدام برنامج solid workو gambit في التحليل وبالاعتماد على أفضل تصميم. وأظهرت الدراسة العددية ان درجات الحرارة تقل على طول الملف وفرق درجات الحرارة له تأثير على انتقال الحرارة وهناك فرق في درجة الحرارة بين لفة واخرى .تم تطوير معادلة تجريبية لتوقع عدد ناسلت لأنبوب محلزن كما بينت المقارنة بين النتائج العملية والعددية بينت توافق جيد.


Article
Numerical Study of Heat Transfer Enhancement in Heat Exchanger Using AL2O3 Nanofluids
دراسة عددية لتحسين انتقال الحرارة داخل مبادل حراري باستخدام نانو اوكسيد الالمنيوم-الماء

Author: Hussein Talal Dhaiban حسين طلال ذيبان
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2016 Volume: 22 Issue: 4 Pages: 98-115
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

In this study, the flow and heat transfer characteristics of Al2O3-water nanofluids for a range of the Reynolds number of 3000, 4500, 6000 and 7500 with a range of volume concentration of 1%, 2%, 3% and 4% are studied numerically. The test rig consists of cold liquid loop, hot liquid loop and the test section which is counter flow double pipe heat exchanger with 1m length. The inner tube is made of smooth copper with diameter of 15mm. The outer tube is made of smooth copper with diameter of 50mm. The hot liquid flows through the outer tube and the cold liquid (or nanofluid) flow through the inner tube. The boundary condition of this study is thermally insulated the outer wall with uniform velocity at (0.2, 0.3, 0.4 and 0.5 m/s) at the cold loop and constant velocity at (0.5 m/s) at the hot loop.The results show that the heat transfer coefficient and Nusselt number increased by increasing Reynolds number and particle concentration. Numerical results indicate that the maximum enhancement in Nusselt number and heat transfer coefficient were 9.5% and 13.5% respectively at Reynolds number of 7100 and particles volume fraction of 4%. Results of nanofluids also showed a good agreement with the available empirical correlation at particles volume fractions of 1%, 2% and 3%, but at volume fractions of 4% a slight deviation is obtained.

تمت عددياً دراسة خواص الجريان وانتقال الحرارة لمائع نانو اوكسيد الالمنيوم-الماء لمدى من عدد رينولدز 3000, 4500, 6000 و 7500 مع مدى من التركيز الحجمي لللدقائق من 1%, 2%, 3% و 4%. يتألف جهاز الاختبار من دورة باردة ودورة حارة مع جريان متعاكس للمائع داخل انبوب مزدوج متحد المركز بطول متر واحد. الانبوب الداخلي مصنوع من النحاس الاملس بقطر يعادل 15 مليمتر. والأنبوب الخارجي مصنوع من النحاس الاملس بقطر يعادل 50 مليمتر. جريان المائع الساخن خلال الانبوب الخارجي وجريان المائع البارد (او النانوي) خلال الانبوب الداخلي. الشروط الحدودية لهذه الدراسة هي السطح الخارجي معزول مع سرع متغيرة (0.2, 0.3 , 0.4 و 0.5)مثا للدورة الباردة وسرعة ثابتة (0.5 )مثا للدورة الساخنة. النتائج تبين ان معامل انتقال الحرارة وعدد نسيلت تزداد بزيادة عدد رينولد ومعامل التركيز الحجمي . والنتائج العددية تمثلت بأعلى نسبة تحسين لعدد نسلت ومعامل انتقال الحرارة ب 9.5% و 13.5% على التوالي عند عدد رينولد 7100 ومعامل التركيز الحجمي للجزيئات 4%.كذلك النتائج بينت توافق جيد مع معادلة عددية عند معامل التركيزالحجمي للجزيئات 1%, 2% و 3% ولكن بمعامل الكسر الحجمي 4% حدث اختلاف بسيط .


Article
Two-pass heat-exchanger performance By programmable method

Author: Saosun Abd AL-Shaheed
Journal: journal of kerbala university مجلة جامعة كربلاء ISSN: 18130410 Year: 2012 Volume: 10 Issue: 1 Pages: 31-40
Publisher: Kerbala University جامعة كربلاء

Loading...
Loading...
Abstract

The goal of heat exchanger design is to relate the inlet and outlet temperatures, the over all heat transfer coefficient, to the rate of heat transfer between the two fluids .The use of programming method can greatly aid in optimizing the design.In this study a programmable method [successive summation method] is developed, applied and presented here using Microsoft Visual Basic (version 6) to determine heat – transfer coefficients and the operating temperatures of a two pass heat exchanger [tube bundle permits a hot gas to pass in a-u- pattern through the exchanger with a shell side contains one – pass cooling water], has replaced the classical log-mean temperature difference , LMTD,method. As many plant heat exchanger operations are not accurately analyzed by this method, due to the correction factors associated with it, which must be obtained experimentally where complete sets of data are rare.

هدف تصميم المبادل الحراري هو إيجاد العلاقة بين درجات حرارة دخول وخروج المائع الساخن والبارد , والمعامل الإجمالي لانتقال الحرارة للمبادل مع معدل انتقال الحرارة بينهما , استخدام البرامج الحاسوبية له فائدة كبيرة في الحصول على التصميم الأمثل. تمت في هذه الدراسة إعداد واستخدام طريقة برمجية للجمع التعاقبي باستعمال برنامج مايكروسوفت البيسك المرئي (الإصدار 6) , لحساب المعامل الإجمالي لانتقال الحرارة ودرجات حرارة دخول وخروج الموائع لمبادل حراري (متقابل الانسياب) يحوي حزمة من الأنابيب ذو مسار على شكل حرف u يحوي الغاز الحار ومسار واحد للاسطوانة تحوي الماء البارد) , بدلاً من (استخدام طريقة المتوسط اللوغارتمي لفرق درجات الحرارة)حيث تعتمد الأخيرة على (معامل التصحيح) الذي يتم تعينيه تجريبياً , والتي تنقصها الدقة لاعتمادها على النتائج العملية .


Article
Natural Convection from Single Finned Tube Immerrsed in a Tilted Enclosure

Authors: Hadi R. Roomi --- Ikhlase M. Fayed
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2007 Volume: 13 Issue: 3 Pages: 1585-1600
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

Heat transfer rates of a single horizontal finned tube immersed in water –filled enclosure tilted at 30 degrees are measured .The results serve as a baseline case for a solar water heating system with a heat exchanger immersed in integral collector storage. Tests were made with both adiabatic and uniform heat flux boundary conditions. Natural convection flow in enclosure is interpreted from measured water temperature distributions. Formation of an appropriate temperature difference that drives natural convection is determined .Correlations for the overall heat transfer coefficient in terms of the Nusselt and Rayleigh numbers are reduced to the form Nu = 0.716 Ra^0.247for 2*10^5 <= Ra <= 2*10^7 Based on the diameter of the immersed tube .Comparison the present work results with others gave a good agreement.

قيس معدل انتقال الحرارة من أنبوب منفرد مغمور في ماء داخل مغلف . المغلف مائل عن الأفق بزاوية º 30 . ممكن تمثيل النتائج لمنظومة تسخين بالطاقة الشمسية لمبادل حراري مغمور في مجمع الطاقة الشمسية أجريت الاختبارات لحالة العزل الحراري من جميع الجهات بوجود شروط حدية بثبوت درجة حرارة المائع مرة والحالة الثانية العزل الحراري من جميع الجهات ما عدا السطح العلوي إذ يتعرض لثبوت الفيض الحراري ممكن تمثيل جريان انتقال الحرارة بالحمل الحر داخل المغلف من خلال قياس درجات الحرارة داخله . العلاقة التجريبية لانتقال الحرارة بالحمل الحر ممكن تمثيلها بدلالة عدد نسلت ورقم رايلي من خلال العلاقة التجريبية التالية:Nu=0.716Ra^0.247 for 2×10^5<=Ra<=2×10^7قيست العلاقة على أساس قطر الأنبوب المغمور. قورنت نتائج البحث الحالي مع بحوث سابقة وحصل على توافق جيد.


Article
Experimental and Theoretical Investigation of Micro Pin Fins Heat Exchanger Used in Convective Cooling Application
دراسة عملية ونظرية لمبادل حراري صغير ذو زعانف أبرية يستخدم في تطبيقات التبريد بالحمل

Authors: Auday.A.Abbo --- Mohammed I. Abu-Tabikh --- Kutaeba J. AL-Khishali
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2010 Volume: 28 Issue: 17 Pages: 5581-5602
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

Experimental and theoretical investigations of flow and thermal performance of an annular pin fin heat exchangers exposed to constant heat flux have been preformed. A special test rig was designed and built for this purpose. The main test section is an annulus of radius ratio (0.85) containing 10 rows of 1mm diameter pins with 5 pins ineach row. The range of cooling air Reynolds number based on the hydraulic diameter of the channel, is (6774 to 11120). In the Theoretical part the well known Fluent (6.3)package was used for solving the governing equations for flow and Energy equation for heat transfer with RNG k-ε turbulence model. Results showed that the pin fins enhanced the heat transfer by a factor of (1.31 to 1.42) and increased the friction factor by (3 to 4) times compared to the one obtained for smooth annular channel without pins. A Nusselt-Reynolds correlation was obtained from the experimental datavalid in the Reynolds number range studied. Reasonable agreement between the experimental and theoretical results was obtained with average difference (5%) over the Reynolds number range. The overall thermal performance obtained was larger than (1).

تمت دراسة الجريان وانتقال الحرارة عمليا و نظريا في مبادل حراري حلقي ذو زعانف أبرية معرض إلى فيض حراري ثابت. تم تصميم وتنفيذ جهاز مختبري متكامل لهذا الغرض يتضمن مقطع اختبار على شكل قناة حلقية ذات نسبة أنصاف أقطار ( 0.85 ) تحتوي على 10 صفوف من 1 مرتبة بواقع 5 زعانف في كل صف. عدد رينولدز لهواء التبريد تراوح mm زعانف أبرية بقطر لحل المعادلات FLUENT( ضمن المدى ( 6700 إلى 11120 ). تم استخدام تقنية برمجيات ( 6.3 أظهرت النتائج أن .(RNG k-ε) الحاكمة للجريان وانتقال الحرارة مع استخدام نموذج الاضطراب الزعانف الابرية تحسن من انتقال الحرارة بواقع ( 1.31 إلى 1.42 ) وتزيد من معامل الاحتكاك ( 3 إلى 4) مرات بالمقارنة مع قناة حلقية ملساء بدون زعانف. تم الوصول إلى معادلة تجريبية تربط عدد ناسلت مع عدد رينولدز نافذة المفعول ضمن مدى عدد رينولدز المحدد في التجارب. وتم الوصول إلى توافق معقول بين النتائج النظرية والعملية بمعدل فارق بين الاثنين بنسبة (% 5). معامل .( الأداء الحراري الكلي للمبادل كان اكبر من (


Article
Performance Characteristics of Parallel Slip Flow Microchannel Heat Exchanger

Authors: Hazim Abdulrazzaq Hanoon --- Ahmed K. M. Alshara
Journal: Basrah Journal for Engineering Science مجلة البصرة للعلوم الهندسية ISSN: Print: 18146120; Online: 23118385 Year: 2011 Volume: 11 Issue: 1 Pages: 16-30
Publisher: Basrah University جامعة البصرة

Loading...
Loading...
Abstract

Parallel flow microchannel heat exchanger performance was numerically investigated, for laminar, 3-D, incompressible and steady state flow with slip flow and temperature jump conditions. The continuity, Navier-Stokes equations and the energy equations for the hot and cold fluids were solved by using finite volumes method and SIMPLE algorithm method with FORTRAN code to obtain the velocity and temperature distributions for the two fluids and the separated wall between them. The main investigation parameter that affected on the performance and effectiveness of heat exchanger are: Reynolds number Re, thermal conductivity ratio Kr, Knudsen number Kn, thickness of separating wall, heat capacity ratio Cr and aspect ratio α. Increasing of Reynolds number, Knudsen number, thickness of separating wall, heat capacity ratio and aspect ratio each separately leads to decrease the effectiveness while increasing of thermal conductivity ratio up to 10 leads to increase the effectiveness. Also, it is found that friction number and Nusselt number both decreases with increasing Knudsen number

حۥقق عدديا أدائيت مبادل حراري مايكروي متىازي الجريان لجريان طباقي ثلاثي الأبعاد وفي حالت الاستقرار ولاانضغاطي بشروط الجريان الأنسلاقي ودرجت الحرارة القافسة. حو عٍادىت الاسخ زَاريت و عٍادلاث اىشخ و عٍادلاث اىطاقتباسخخذا طزيقت اىحجى اى حَذدة و طزيقت ) (SIMPLE algorithm وباسخخذا ىغت فىرحزا ) FORTRAN ,)ىيحصىه عيى حىسيع اىسزعت و درجت اىحزارة وىنلا اى اَئعي واىجذار اىفاصو بي هْ .ٌ عىا وٍ اىبحث اىزئيسيت اىخي حؤثزعيى فعاىيت و ادائيت اى بَاده هي: عذد ري ىْىذس) Re ( و سّبت اى ىَصييت اىحزاريت ) Kr ( و عذد اّدسي ) Kn ( وس لَ اىجذاراىفاصو و سّبت اىسعت اىحزاريت ) Cr ( و سّبت اىىاجهه ) α (. ع ذْ سيادة عذد ري ىْىذس و عذد اّدسي و سّبت اىسعتاىحزاريت وس لَ اىجذار اىفاصو مو عيى حذة حقو اىفعاىيت, وع ذْ سيادة سّبت اى ىَصييت اىحزاريت حشداد اىفعاىيت اىى 10 Kr ,. مذىل اى خْائج حبي بأ عذد الأحخناك و عذد سّيج ملاه اَ يقو ع ذْ اٍ يشداد عذد اّدسي .ِ


Article
Thermo-Hydraulic Performance of Horizontal Circumferentially Ribbed Double Pipe Heat Exchanger
الأداء الحراري-الهيدروليكي لمبادل حراري أفقي مزدوج الأنبوب مضلع بشكل محيطي

Author: . Nawras Shareef Sabeeh . نورس شريف صبيح
Journal: Journal of Engineering and Sustainable Development مجلة الهندسة والتنمية المستدامة ISSN: 25200917 Year: 2014 Volume: 18 Issue: 3 Pages: 183-196
Publisher: Al-Mustansyriah University الجامعة المستنصرية

Loading...
Loading...
Abstract

Heat transfer coefficient and pressure drop for water flow inside circumferential ribbed tubes with different rib dimensions have been determined experimentally. The data of ribbed tubes were compared with that of a plain tube. The experimental test section is a horizontal counter flow concentric tube heat exchanger with circumferentially ribbed inner tube. The ribbed tubes tested in this investigation have the ranges: circumferential depth from 0.5 to 1.5 mm and axial pitch distance from 5 to 15 mm. Water was used as the working fluid, where hot water flows in the inner tube and cold water flows in the annulus. The test runs are done at water flow rates ranging between 0.1 and 1.0 m3/h. The inlet cold and hot water temperatures are between 20 and 30 °C and between 40 and 60 °C, respectively. Comparison of experimental data of circumferentially ribbed tubes with smooth tube have shown that the heat transfer coefficient and pressure drop, quantified by means of Nusselt number and friction factor, are around 1.92 to 5.61 and 1.25 to 3.41 times higher than smooth tube depending on the circumferential geometric parameters and mass velocity of the working fluid. New correlations based on the data gathered during this work for predicting Nusselt number and friction factor for the circumferential ribbed tube heat exchanger have been proposed. The proposed correlations can predict the experimental data with average relative error of ± 6% for Nusselt number and ± 5% for friction factor..

تم حساب معامل انتقال الحرارة و هبوط الضغط لتدفق الماء داخل الانابيب المضلعة بشكل محيطي وبأبعاد تضليع مختلفة تجريبيا. بيانات الانابيب المضلعة تم مقارنتها مع تلك الخاصة بالأنبوب الناعم. ان مقطع الاختبار التجريبي هو عبارة عن مبادل حراري افقي متمركز الانبوب ومتعاكس الجريان مع انبوب داخلي مضلع بشكل محيطي. الانابيب المضلعة التي تم اختبارها في هذا البحث لها المديات الآتية: عمق ضلع محيطي من 0,5 الى 1,5 ملم وبعد محوري من 5 الى 15 ملم. استعمل الماء كمائع تشغيل، حيث يتدفق الماء الحار في الانبوب الداخلي و يتدفق الماء البارد في الانبوب الحلقي. ان التجارب المختبرية تم اجراءها بنسب تدفق ماء تتراوح بين 0,1 و 1,0 م3/ساعة. درجة حرارة الماء البارد والساخن تتراوح بين 20 الى 30 و40 الى 60 °م، على التوالي. مقارنة البيانات التجريبية للأنابيب المضلعة بشكل محيطي مع الانبوب الناعم توضح بان معامل انتقال الحرارة وهبوط الضغط، حددت كميا بواسطة رقم نسلت ومعامل الاحتكاك، حوالي 1,92 الى 5,61 و 1,25 الى 3,41 مرة اعلى من الانبوب الناعم معتمدة على شكل التضليع المحيطي والسرعة الكتلوية لمائع التشغيل. تم اقتراح معادلة ارتباط جديدة مستندة على البيانات التي تم جمعها في هذا العمل لحساب رقم نسلت ومعامل الاحتكاك لمبادل حراري ذو انبوب مضلع بشكل محيطي. ان معادلة الارتباط المقترحة من الممكن ان تحسب البيانات التجريبية بمعدل خطأ نسبي ±6% بالنسبة لرقم نسلت و±5% بالنسبة لمعامل الاحتكاك.-


Article
Experimental and Numerical Investigation to Evaluate the Performance of U-Longitudinal Finned Tube Heat Exchanger
تحقيق عملي ونظري لتقييم أداء مبادل حراري من نوع الأنبوب المزعنف بزعانف طولية على شكل حرف U

Loading...
Loading...
Abstract

Experimental and numerical investigation has been performed in this work to evaluate the performance for U-longitudinal finned tube heat exchanger. Four pairs of U-shaped longitudinal fins were selected and manufactured from copper material and welded on the straight copper tube. The inner tube is inserted inside insulated galvanized tube, sheet and roll insulation (arm flux) and glass wool have been utilized to cover inner and outer surface of galvanized tube for reducing heat losses. Air at various mass flow rates (0.03 to 0.07)kg/sec flows through annuli and de-ionized water at Reynold's numbers ranging from (270 to 1900) flows through the inner tube. Performance of (smooth and finned) tube heat exchanger was investigated experimentally. Experimental results showed (1.744 to 2.534) enhancement ratio when using U-longitudinal fins. Empirical correlations for air, water were represented by Nusselt's number. Numerical simulation has been carried out on present heat exchanger to analyze flow field and heat transfer using FLUENT package 14. The comparison between experimental work and numerical results showed good agreement.

في هذه الدراسة, تم انجاز تحقيق عملي وعددي لمبادل حراري من نوع الانبوب المزعنف بزعانف طولية علئ شكل حرف (U) من اجل دراسة اداءه الحراري. اربعة ازواج من الزعانف الطولية ذات شكل (U) تم تصميمها وتصنيعها من مادة النحاس وثبتت علئ انبوب نحاس الذي اولج داخل انبوب مصنع من مادة الكلفنايز ومعزول بعوازل من الداخل والخارج لتقليل الحرارة المفقودة. هواء عند معدلات تدفق كتلية تتراوح بين (0.03 الئ0.07 ) كغم/ثانية يجري خلال الفراغ الحلقي وماء منزوع الايونات ذو ارقام رينولدز تتراوح بين (270 الئ 1900) يجري خلال الانبوب الداخلي. اداء المبادل الحراري بالحالتين ( الاملس والمزعنف ) تمت دراسته. النتائج العملية بينت ان نسبة التحسين كانت (1.744 الئ 2.534) في حال استخدام المبادل الحراري ذو الانبوب المزعنف. علاقات تجريبية لجانب الهواء والماء تم تقديمها بدلالة رقم نيسلت. محاكاة عددية تم انجازها للمبادل الحراري لتحليل جريان المائع وانتقال الحرارة باستخدام البرنامج المتخصص 14ANSYS FLUENT. بينت المقارنة بين النتائج العملية والعددية وجود تطابق مقبول.

Listing 1 - 10 of 79 << page
of 8
>>
Sort by
Narrow your search

Resource type

article (79)


Language

English (65)

Arabic and English (10)

Arabic (4)


Year
From To Submit

2019 (5)

2018 (11)

2017 (8)

2016 (9)

2015 (8)

More...