research centers


Search results: Found 18

Listing 1 - 10 of 18 << page
of 2
>>
Sort by

Article
Using heat pipes in greenhouse heating
استخدام أنابيب الحرارة في تدفئة البيت البلاستيكي

Author: Raqeeb Hummadi Rajab رقيب حمادي رجب
Journal: Journal Of Kirkuk University For Agricultural Sciences مجلة جامعة كركوك للعلوم الزراعية ISSN: 22210482 Year: 2012 Volume: 3 Issue: 2 Pages: 1-11
Publisher: Kirkuk University جامعة كركوك

Loading...
Loading...
Abstract

In the present work an instrumented heat pipe is designed, constructed and inserted inside a greenhouse to be used as a heating source during night or cloudy days in the cold months. Transferring geothermal heat from underground to the surrounding inside the greenhouse without consumption of conventional energy is one of the latest applications of the heat pipe device to transfer heat. The heat pipe is made of a sealed metal tube containing water as a working fluid. It is divided into three sections; the evaporator, adiabatic section and condenser. The buried part of the heat pipe is the evaporator section which transfers heat from the underground soil to the working fluid, which is in turn, transfers heat to the condenser where it is rejected to the surrounding inside the greenhouse. This study was conducted on a greenhouse with an area of (3.75)m2. Two heat pipes inserted at different depths inside the greenhouse soil were used to investigate the performance of this device. Results show an increase, with stability, of the environment temperature inside the greenhouse when the heat pipe is implemented in the cold and cloudy days of the cold winter months. The temperature inside the greenhouse reached (20)oC when the heat pipe inserted inside the soil to a level of(3.5)m with heat transfer rate of (126)W, while the outside temperature was about(14)oC.

في هذا البحث صمم وصنع أنبوب حراري لاستخدامه داخل البيوت البلاستيكية كمصدر للتدفئة ليلا والأيام الغائمة في الأشهر الباردة، بالاستفادة من الحرارة المخزونة في باطن الأرض بدون استهلاك للطاقة التقليدية، وذلك بتطبيق التقنية الحديثة في انتقال الحرارة بواسطة الأنبوب الحراري والذي هو عبارة عن أنبوب معدني مفرغ محكم يحتوي على الماء كمائع تشغيل. يتكون الأنبوب الحراري من ثلاثة اجزاء: المبخر، جزء ثابت الحرارة والمكثف. يدفن المبخر داخل التربة فتتنقل الحرارة من باطن الأرض إلى السائل الموجود في المبخر ثم تنقل إلى المكثف الذي بدوره يطرح الحرارة لمحيطه داخل البيت البلاستيكي. أجريت هذه الدراسة على بيت بلاستيكي بمساحة (3.75)م2 ,واستخدم اثنان من انابيب الحرارة ودفنا في التربة لمستويات عمق مختلفة تحت الأرض لمعرفة أداء الأنبوب الحراري. النتائج أظهرت زيادة واستقراراً في درجة الحرارة داخل البيت البلاستيكي في الأيام الباردة والغائمة من أشهر الشتاء الباردة وصلت إلى(20)oم، عند مستوى عمق (3.5) متر وبمعدل انتقال حرارة (126) واط بينما كانت درجة الحرارة خارج البيت البلاستيكي حوالي (14) oم

Keywords

heat pipe --- greenhouse --- heating


Article
EXPERIMENTAL STUDY OF WICK STRUCTURE MATERIAL AND SCREEN MESH ON HEAT PIPE PERFORMANCE
دراسة عملية لهيكل المواد النسيجية على اداء الانبوب الحراري

Loading...
Loading...
Abstract

An experimental study has been done on heat pipe 1000mm length and 25.4mm diameter. Evaporator section is formed by adopting a coil heater over 240mm from one side of heat pipe length. The condenser section is formed by adopting a water jacket over 300mm from the other end of heat pipe length. The working fluids used is R-134a. The used wick structure is of square meshes of (Bronze150*150, Bronze200*200 and Copper145*145). The wick structure is formed by turning the square mesh layer six times to form an internal circumference for heat pipe inner diameter. The supplied power over evaporator (20, 30, 40 and 60)W. Thermal conductivity of Copper is 401W/m.Co and Bronze is 51.2 W/m.oC . It is found that the thermal conductivity has no effect on the heat pipe performance. But mesh screen size affected the performance the heat pipe and increases the temperature along the heat pipe.

اجريت دراسة عملية لأنبوب حرارة بطول (1000mm) وقطر(25.4mm) . يتكون المبخر من خلال وضع مسخن حراري على طول (240mm) من الطول الكلي لأنبوب الحراري من أحد طرفيه بينما يكون المكثف من خلال وضع جيب مائي على طول (300mm) من طول الأنبوب . كان مائع التشغيل المستخدم (R134a). بينما كانت المواد النسيجية المستخدمة هي (برونز 150x150 ,برونز200x200 و نحاس 145x145) تم تشكيل المواد النسيجية عن طريق لفها ستة لفات لتكون القطر الداخلي لانبوب الحرارة. القدرة المجهزة للمبخر(20, 30, 40, and 60W) مع كل نوع من المواد النسيجية. الموصلية الحرارية للنحاس (401W/m.oC) وللبرونز(51.2W/m.oC). لقد وجد بأن الموصلية الحرارية لا تؤثر على أداء الأنبوب الحراري. لكن التشبيك النسيجي له تأثير واضح فكلما زاد التشبيك النسيجي انخفض أداء الأنبوب وارتفعت درجة الحرارة على طول الأنبوب .


Article
A Heat Pipe Performance With Heptane as aWorking Fluid
دراسة عملية لأداء أنبوب حراري باستخدام الهيبتان كمائع تشغيلي

Authors: Hussain H.Ahmad --- Raqeeb H. Rajab
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2013 Volume: 31 Issue: 4 Part (A) Engineering Pages: 646-660
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

The heat pipe is a device that efficiently transfers heat from one end to another. It has been widely applied in electronic system cooling and heat spreading applications due to its superior heat conductivity. Many parameters affect the performance of the heat pipe which are worthwise to be investigated. For this reason an experimental rig was designed and constructed to study the important parameters such as the heat load, the working fluid charge and the angle of inclination. Calibrated thermocouples were inserted into the heat pipe outside surface, along and around it, to measure and to show the temperature distribution profile. Heptane was used as a working fluid. Results show that the maximum conductivity obtained was more than one thousand times that of stainless steel solid bar which is the material of the heat pipe container. Also, results of the experimental work show a good agreement with that obtained from theoretical and empirical correlations derived by other researchers especially when the power input is lower than (1000)W where after a dry out condition can be clearly seen.

أنبوب الحرارة جهاز كفوء وفعال جداً لنقل الحرارة من طرف إلى أخر، يستخدم في الوقت الحاضر بصورة واسعة في تبريد المنظومات الإلكترونية وانتشرت تطبيقاته الحرارية بسبب موصليته الفائقة. العديد من العوامل تؤثر على أداء أنبوب الحرارة التي تستحق ذلك الجهد في البحث والتحقق فيها. لهذا السبب تم تصميم الجهاز المختبري وتصنيعه لدراسة تأثير العوامل الحاكمة المختلفة, كالطاقة المجهزة لمبخر الأنبوب الحراري,كمية شحن السائل التشغيلي وزوايا الميل المختلفة. ثبتت متحسسات حرارية معيّرة على طول وحول سطح أنبوب الحرارة لقياس وبيان توزيع درجات الحرارة. أستخدم الهيبتان في هذا البحث كسائل تشغيلي .أظهرت النتائج التجريبية أن الموصلية الحرارية عالية وهي بحدود أكثر من ألف مره بقدر توصيلية قطعه صلدة من الفولاذ التي صنع منها الأنبوب الحراري. كانت النَتائج التجريبية للعمل الحالي متفقة بصوره جيدة مع نتائج معادلات عملية ونظرية لباحثين آخرين، خاصة عند الطاقة المجهزة الاقل من (1000W) بعدها يمكن ملاحظة ظاهرة الجفاف بوضوح .

Keywords

heat pipe --- wick --- filling ratio


Article
Experimental Investigation of Individual Evacuated Tube Heat Pipe Solar Water Heating Systems

Authors: Hassan N. S. Al-Joboory --- Khalid A. Joudi
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2012 Volume: 18 Issue: 2 Pages: 203-222
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

The work involves outdoor experimental testing of ten individual evacuated tube heat pipe solar water heating systems with heat pipes of three diameter groups of 16, 22 and 28.5 mm. The first and third groups had evaporator lengths of 1150, 1300 and 1550 mm. The second group had an additional length of 1800 mm. all heat pipes were of fixed condenser length of 200 mm. Ethanol at 50% fill charge ratio of the evaporator volume was used as the heat pipes working fluid. Each heat pipe condenser section was inserted in a storage tank and the evaporator section inserted into an evacuated glass tube of the Owens- Illinois type. The combined heat pipe and evacuated glass tube form an active solar collector of a unique design. The resulting ten solar water heating systems were tested outdoors under the meteorological conditions of Baghdad, Iraq. Experiments were carried out with no load, intermittent and continuous load conditions. Some tests, at no load, were carried out with and without reflectors. The overall system efficiency was found to improve with load conditions by a maximum of 55%. The system employing an 1800 mm evaporator length and 22 mm heat pipe (HP7) showed the best performance by higher water temperatures, overall useful energy gain and efficiency at various load conditions. System performance was predicted theoretically using electrical analogy derived from an energy balance. An agreement of within 14% was obtained between theoretical and experimental values.

يتضمن البحث فحصا تجريبيا بالخارج لعشر منظومات تسخين مياه بالطاقة الشمسيه ذات الأنبوب الحراري في الأنبوب المفرغ تستخدم أنابيب حرارية بثلاث أقطار هي 16 و22 و28.5 ملم. تكونت مجموعتي الأنابيب ذات القطرين الأول والثالث من أنابيب بأطوال مبخر 1150 و1300 و 1550 ملم بينما شملت المجموعة الثانية طولا اضافيا هو 1800 ملم. كانت جميع الأنابيب بطول مكثف ثابت يبلغ 200 ملم. شحنت جميع الأنابيب الحراريه بالايثانول كمائع شغل بنسبة شحن بلغت 50% من حجم المبخر. تم إدخال المكثف لكل أنبوب حراري في خزان ماء وادخل المبخر في أنبوب زجاجي مفرغ من نوع أوينز- ألينويز وأصبحت الوظيفة المركبة الناتجة من ذلك تكون لاقط شمسي فعال ذو تصميم فريد. كانت المنظومات الناتجة عشرة منظومات فردية ذات أنبوب حراري في الأنبوب المفرغ لتسخين الماء بالطاقة الشمسية والتي تم فحصها تجريبيا في الظروف الجوية لمدينة بغداد. أجريت التجارب على هذه المنظومات بدون حمل وبحمل متقطع وحمل مستمر. كما أجريت بعض التجارب بدون حمل مع سطح عاكس وبدونه. وقد تحصل أفضل أداء من المنظومة ذات الأنبوب الحراري HP7 بطول مبخر 1800 ملم وقطر 22 ملم من بين المنظومات العشر والذي تمثل بدرجات حرارة ماء ساخن أعلى وتخزين طاقة حرارية كلية وكفاءة أعلى مع جميع أشكال التحميل. تبين من خلال البحث أن الكفاءة الكلية للمنظومات الشمسية تحسنت مع التحميل بمقدار أقصاه 55%. تم القيام بتحليل نظري للمنظومات الشمسية باستخدام منظومة مقاومات كهربائية مناظرة متأتية من الاتزان الحراري للمنظومة الشمسية وعند مقارنة الأداء العملي مع هذه الاستنتاجات النظرية حصل توافق جيد بحدود 14% بين القيم النظرية والقيم العملية.


Article
Parametric Simulation on Enhancement of the Regenerative Gas Turbine Performance by Effect of Inlet Air Cooling System and Steam Injection

Author: Aadel Abdulrazzaq Alkumait
Journal: Tikrit Journal of Engineering Sciences مجلة تكريت للعلوم الهندسية ISSN: 1813162X 23127589 Year: 2015 Volume: 22 Issue: 1 Pages: 38-44
Publisher: Tikrit University جامعة تكريت

Loading...
Loading...
Abstract

Iraq being one of the developing countries of the world considers energy efficiency and the impact of its generation on the environment an imperative process in improvement of its power generation policies. Iraq bearing high temperatures all year long results in reduction of air density, therefore, Inlet air Cooling and Steam Injection Gas Turbines are a striking addition to the regenerative gas turbines. Regenerating Gas turbines tend to have a high back work ratio and a high exhaust temperature, thus, it leads to a low efficiency in power generation in hotter climate. Moreover, STIG and IAC through fog cooling have known to be the best retrofitting methods available in the industry which improve the efficiency of generation from 30.5 to 43% and increase the power output from 22MW to 33.5MW as the outcomes of computer simulations reveal. Additionally, this happens without bringing about much extensive change to original features of the power generation cycle. Furthermore, STIG and spray coolers have also resulted in power boosting and exceeding generation efficiency of gas turbine power plant.


Article
Design and Implementing A Heat Pipe Expperimantal System For Residential Heating

Authors: Zeina A. Al-Saadi --- Mikdam M. saleh
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2007 Volume: 13 Issue: 4 Pages: 2031-2052
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

The design and construction of an instrumented heat pipe H.P for domestic heating that uses water as a working fluid was undertaken to investigate experimentally the performance of the H.P under various operating conditions of: Power levels, water inventories and angle of inclinations. A theoretical model to predict the temperature of the condenser surface (the temperature at which heat is rejected) and system pressure at steady state conditions was developed and used to compare these parameters with the experimental findings. The model utilizes the total heat supplied to the evaporator to predict system pressure and condenser temperature. The theoretical model is suitable for vertical H.P (i.e. θ =0º) and its predictions of condenser surface temperature is within ±16% and of system pressure is within ±21%. An acceptable H.P design may have a condenser heat flux of 1.16 k W/m2 with a corresponding system pressure of 1500 kPa.

تم تصميم و بناء منظومة أنبوب حراري للتدفئة المنزلية التي يستخدم الماء كمائع تشغيلي. أخذنا بنظر الاعتبار عند البحث التجريبي لأداء الأنبوب الحراري التغيرات في العوامل التشغيلية التالية:مختلف مستويات القدرة الداخلة إلى المسخن ومستويات مختلفة للمائع داخل المنظومة(Inventory) إضافة إلى زوايا ميل مختلفة (Inclination Angle ). النموذج النظري الذي تم تطويره يتمكن من حساب المعدل لدرجة الحرارة السطحية للمكثف tc) و ضغط المنظومة(P )في حالة الاستقرار.وتمت مقارنة النتائج العملية مع الحسابات النظرية ووجد أن النموذج النظري يستخدم الحرارة الكلية المسلطة على المسخن لتوقع ضغط المنظومة ودرجة حرارة المكثف ويعتبر هذا النموذج مناسب للأنبوب الحراري الوضع العمودي (0º =θ ) والنموذج الرياضي يعطي قيم بحدود (±15%) لدرجة الحرارة السطحية للمكثف و(±21%) لضغط المنظومة. نستنتج أن التصميم العملي المقبول لمنظومة التدفئة المنزلية يجب أن يكون ضمن حدود كثافة فيض حراري( 1.16kw/m2) خلال ضغط منظومة (1500 kpa) وزاوية ميل تتراوح بين(0-30º ).


Article
An Experimental Study of Parameters Affecting a Heat Pipe Performance
دراسة عملية للعوامل المؤثرة على أداء أنبوب حراري

Authors: Dr. Hussain H.Ahmad د.حسين حامد احمد --- Raqeeb H. Rajab رقيب حمادي رجب
Journal: AL Rafdain Engineering Journal مجلة هندسة الرافدين ISSN: 18130526 Year: 2010 Volume: 18 Issue: 3 Pages: 97-117
Publisher: Mosul University جامعة الموصل

Loading...
Loading...
Abstract

AbstractAn experimental test rig was designed and manufactured to investigate the performance of a heat pipe(HP). The heat pipe consists of a stainless steel pipe lined with a three-layer stainless steel mesh wick. The evaporator section of the heat pipe was surrounded by three heaters representing the heat source. The condenser was jacketed with galvanized cylinder to accommodate the cooling water flow. The entire HP was insulated. Different affecting parameters were investigated experimentally in this study including the power input the filling charge of the working fluid(water) represented by a volumetric ratio with respect to evaporator volume and the inclination angle with a horizontal line. All tests were carried out at a pressure around the atmospheric pressure during steady state conditions. The experimental results showed that the conductivity was about (2060) times that of the solid piece of the stainless steel (the material of the HP).A comparison between the present work results with empirical and theoretical correlations of other researchers showed a good agreement. Key words: heat pipe , wick , filling ratio

الخلاصةتم تصميم الجهاز المختبري وتصنيعه للتحري تجريبيا ً في أداء الأنبوب الحراريِ. يتكون الأنبوب الحراري من أنبوب فولاذ مقاوم للصدأ مبطن بفتيلة ذات ثلاث طبقات من (شبكة سلكية من الفولاذ المقاوم للصدأ). مقطع المبخر محاط بثلاثة مسخنات تمثل المصدر الحراري, أما المكثف فتحيطه صفيحة اسطوانية مغلونة يجري خلالها ماء التبريد. تم عزل الأنبوب الحراري كاملاً . في هذه البحث تم التحقق تجريبياً من تأثير عوامل مختلفة تتضمن الطاقة المجهزة للمبخر, كمية شحن السائل التشغيلي(الماء) متمثلة بنسبة حجميه من حجم المبخر وبزوايا ميل متغيره مع المستوى الأفقي تحت ضغط مقارب للضغط الجوي عند حالة الاستقرار. أظهرت النتائج التجريبية أن الموصلية الحرارية هي بحدود (2060) مره بقدر موصلية قطعه صلدة من الفولاذ التي صنع منها الأنبوب الحراري. المقارنة بين نتائج العمل الحالي مع نتائج معادلات عملية ونظرية لباحثين آخرين أظهرت توافقا ً جيدا ً.


Article
NUMERICAL ANALYSIS OF VAPOR FLOW IN A HORIZONTAL CYLINDERICAL HEAT PIPE
التحليل العددي لجريان البخار في أنبوب حراري أفقي أسطواني

Loading...
Loading...
Abstract

The steady two-dimensional flow of a horizontal heat pipe in vapor region is investigated numerically. For study of heat transfer and fluid flow behaviors of the heat pipe, the governing equations in vapor region have been solved using a finite difference method. The numerical results of heat transfer and fluid flow are presented for Reynolds numbers ranging of (Re =4, 10), the Prandtl number taken is (Pr=0.00368), and the pipe dimension is taken to be (L/R =5). The results show that the stream function at the wall increases linearly in the evaporator, decreases linearly in the condenser and is steady in the adiabatic region because of uniform inflow and outflow boundary conditions. Also, it can be seen that as the Reynolds number increases, the pressure distributions shift up without considerable change in their shapes. The numerical analysis have shown that for the low and moderate Reynolds number, the shear stress becomes zero at a point very close to the end of the condenser. For verification of current model, the results of stream function for a heat pipe have been compared with the previous study at the same boundary conditions and a good agreement has been noticed.

تم إجراء دراسة عددية لجريان مائع مستقر ثنائي البعد في أنبوب حراري أفقي لمنطقة البخار. من أجل دراسة سلوك انتقال الحرارة وجريان المائع في ألأنبوب الحراري. استخدمت طريقة الفروق المحددة لحل المعادلات الحاكمة لمنطقة البخار. تم تمثيل النتائج العددية لمعادلات انتقال الحرارة لعدد رينولدز في المدى (Re =4, 10), إخذ عدد برانتل (Pr=0.00368), وأبعاد الأنبوب إخذت بنسبة ( L/R =5) . النتائج بينت ان قيم دالة الجريان عند الجدار تزداد للمبخر وتنقص للمكثف بشكل خطي ومستقرة للمنطقة المعزولة حراريا" بسبب الظروف الحدية المتجانسة لمنطقة الدخول والخروج. كذلك لوحظ عند زيادة عدد رينولدز, أن توزيع الضغط يرتفع بدون حدوث تغيير كبير بإشكاله. النتائج العددية بينت لعدد رينولدز الواطيء والمعتدل , أن أجهاد القص اصبح صفرا" عند نقطة قريبة جدا" لنهاية المكثف. وللتحقق من النموذج الحالي, تم مقارنة النتائج العددية لدالة الجريان مع دراسة سابقة عند نفس الظروف الحدية وكانت مقبولة.


Article
Heat Transfer Characteristics in a Heat Pipe Using Water-Hydrocarbon Mixture as a Working Fluid. (An Experimental Study
خصائص انتقال الحرارة في أنبوب حراري باستخدام خليط ماء- هايدروكاربون كمائع تشغيل (دراسة عملية)

Author: Dr. Hussain H. Ahmad د. حسين حامد احمد
Journal: AL Rafdain Engineering Journal مجلة هندسة الرافدين ISSN: 18130526 Year: 2012 Volume: 20 Issue: 3 Pages: 128-137
Publisher: Mosul University جامعة الموصل

Loading...
Loading...
Abstract

Abstract The heat pipe is a very effective device in heat transport, therefore it is used in many industrial applications especially in cooling systems. In the present experimental work, wickless heat pipe(thermosyphon)is designed and constructed from a copper tube of inside and outside diameters (13.5) and (15.5)mm respectively with total length of (600)mm divided into three sections evaporator; adiabatic section and a finned air cooled condenser simulating the actual applications in practice of this device. Pure water, pure hydrocarbon fluid (acetone) and mixtures of the two fluids at different ratios by weight were used as working fluid to investigate the effect of a working fluid type and mixture ratio on the performance of the device. Results show that using pure fluid is more effective than using mixture. Comparison between results of the present work and a theoretical correlation shows a good agreement especially when using pure fluid.Keywords: Thermo syphon; Heat pipe; Mixture.

الخلاصةالأنبوب الحراري جهاز ذو فعالية عالية في نقل الحرارة. لذا يستخدم في كثير من التطبيقات الصناعية وخاصة في منظومات التبريد. تم في البحث الحالي تصميم وتصنيع أنبوب حراري (بدون فتيلة) من أنبوب نحاسي ذي أقطار داخلية وخارجية (13.5),(15.5) ملم على التوالي وبطول كلي (600) ملم مقسم إلى ثلاثة أجزاء: المبخر, الواصل المعزول والمكثف ذي الزعانف والمبرد بالهواء كمحاكاة لتطبيقات عملية. استخدم الماء النقي والهايدروكاربون النقي (أسيتون) وخليط من هذين المائعين بنسب مختلفة كمائع تشغيل وذلك لاستقصاء تأثير نوع المائع ونسب الخليط على أداء الجهاز . أظهرت النتائج أن استخدام مائع نقي بدل الخليط يكون أكثر كفاءة من استخدام خليط من مائعين. أظهرت المقارنة بين نتائج البحث الحالي مع علاقات نظرية توافقا جيدا خاصة عند استخدام مائع نقي.


Article
Optimum design of a heat pipe
التصميم الأمثل لأنبوب حراري

Author: Mohammad S.Q. Aldabbagh محمد سالم قاسم الدباغ
Journal: AL Rafdain Engineering Journal مجلة هندسة الرافدين ISSN: 18130526 Year: 2015 Volume: 23 Issue: 2 Pages: 133-146
Publisher: Mosul University جامعة الموصل

Loading...
Loading...
Abstract

This research deals with the optimum design of the heat pipe components using Matlab program, version 7, at the determined operating conditions. The heat pipe is used to transfer maximum available thermal energy to heat the feed water entering steam boiler .The affecting parameters on heat pipe performance were detailed as well as the transport limitations and the thermal resistances of the heat pipe parts. Satisfactory results were obtained for the heat pipe dimensions, components and design influentials. Also, the parameters affecting the heat transfer rate and the working fluid mass-flow rate were discussed. From the important results, the heat pipe heat transfer capability is directly proportional with each of the heat pipe bore, the wick c/s area and the heat pipe effective length, and inversely with each of the capillary radius and the working fluid viscosity.

يتناول هذا البحث التصميم الامثل لاجزاء ومكونات انبوب حراري باستخدام برنامج Matlab الاصدار 7، عند ظروف التشغيل المحددة. يستخدم الانبوب الحراري لنقل اكبر طاقة حرارية ممكنة لتسخين الماء المغذي الداخل الى مرجل بخاري .وقد تم تفصيل العوامل المؤثرة على اداء الانبوب الحراري ومحددات انتقال الحرارة والمقاومة الحرارية لاجزاء الانبوب الحراري، والحصول على نتائج مرضية لابعاد ومكونات الانبوب الحراري ومؤثرات التصميم، وكذلك مناقشة العوامل المؤثرة على كل من معدل إنتقال الحرارة ومعدل جريان كتلة مائع التشغيل.من النتائج المهمة هي ان مقدرة الانبوب الحراري على نقل الحرارة تتناسب طرديا وكل من قطر الانبوب ومساحة مقطع الفتيلة والطول المؤثر للانبوب، وعكسيا مع كل من نصف القطر الشعري ولزوجة مائع التشغيل.

Listing 1 - 10 of 18 << page