Experimental Investigation of the Effect of Curvature Ratio on Heat Transfer in Double Pipe Helical Heat Exchanger
تحقيق عملي من تأثير نسبة الأنحناء على انتقال الحرارة في مبادل حراري حلزوني مزدوج الأنبوب

Author: Hisham Assi Hoshi هشام عاصي حوشي
Journal: Al-Khwarizmi Engineering Journal مجلة الخوارزمي الهندسية ISSN: 18181171 23120789 Year: 2018 Volume: 14 Issue: 1 Pages: 10-18
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

Different parameters of double pipe helical coil were investigation experimentally. Four coils were used; three with a curvature ratio (0.037, 0.031, and 0.028) and 11mm diameter of the inner tube while the fourth with 0.033 curvature ratio and 13 mm diameter of the inner tube. The hot water flow in the inner tube whereas the cold water flows in the annulus. The inlet temperatures of hot and cold water are 50 0C and 18 0C respectively. The inner mass flow rate ranges from 0.0167 to 0.0583 kg/s. The results show the Nusselt number increase with increase curvature ratio. The Nusselt number of the coil with 0.037 curvature ratio increases by approximately 12.3 % as compare with 0.028 curvature ratio. The results also reveal that the Nusselt number of the coil with curvature ratio 0.033 increases by approximately 11.6 % as compare with 0.028 curvature ratio for 400 mm coil diameter.

عدة عوامل متغيرة للفائف حلزونية مزدوجة الأنبوب وتم استخدام أربع لفائف. ثلاث مع نسبة انحناء (0.037, 0.031, 0.028) و 11 ملم قطر الأنبوب الداخلي في حين أن الرابع مع 0.033 نسبة انحناء و 13 ملم قطر الأنبوب الداخلي. يتدفق الماء الساخن في الأنبوب الداخلي في حين يتدفق الماء البارد في الحلقة. درجة حرارة مدخل الماء الساخن والماء البارد هي 50 0C 18 0C على التوالي. ويتراوح معدل التدفق الكتلي الداخلي من 0.0167 إلى 0.0583 كجم / ثانية . أظهرت النتائج زيادة عدد نسلت مع زيادة نسبة الانحناء. أن عدد نسلت من الملف نسبة انحناءه 0.037 يزيد بحوالي 12.3 % مقارنة مع الملف نسبة انحناءه 0.028 . كما كشفت النتائج أن عدد نسلت من الملف نسبة انحناءه 0.033 يزيد بحوالي 11.6 % مقارنة مع الملف نسبة انحنائه 0.028 لملف قطره 400 ملم.


Article
Field Study of Novel Storage Tank of Solar Water Heating System
دراسة ميدانية لخزان جديد مستخدم في منظومة شمسية لتسخين الماء

Authors: Karima Esmail. Amori كريمة أسماعيل عموري --- Jinan Shaker Sherza جنان شاكر شيرزة
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2013 Volume: 19 Issue: 5 Pages: 597-612
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

In this paper thermo-hydrodynamic characteristics were investigated experimentally for a new type shell-helical coiled tube heat exchanger used as a storage tank of closed loop solar water heater system. Triple concentric helical coils were made of copper tubes of (12.5mm OD and 10mm ID) with coils diameter of (207, 152.2, 97mm) for outer, middle and inner coils respectively. The experiments were carried out during a clear sky days of (March and April 2012). The parameters studied in this work are: history of average temperature of shell side of the storage tank, collector heat gain, heat rejected from coils to shell side of the storage tank, collector efficiency, thermal effectiveness of the heat exchanger )storage tank), and pressure drop. These parameters were studied at four different circulating mass flow rates of (1.8, 3, 6, 9 l/min) and for two consuming modes of supply water namely no withdrawal, and continuous withdrawal of (1 l/min). The results show that stratification temperature in the storage tank is increased for no withdrawal compared with water withdrawal, also the shell side average temperature increases with increased solar time. Collector efficiency is increased with increasing circulation flow rates, also increases with water withdrawn from storage tank. The pressure drop decreases with the increase of solar radiation .

في هذا البحث تم التحقق من المواصفات الحرارية والهيدروديناميكية عمليا لمبادل حراري جديد نوع قشرة-أنبوب ملتف حلزونيا مستخدم كخزان لمنظومة شمسية لتسخين الماء. صنعت ثلاثة ملفات حلزونية متمركزة من أنبوب نحاس ذو قطر خارجي =12.5 ملم وقطر داخلي=10ملم وبقطر ملف خارجي، وسطي، وداخلي (207، 152.2، و 97ملم) على التوالي. أجريت التجارب في أيام صحوة خلال شهري آذار ونيسان من سنة 2012. درست المتغيرات التالية: توزيع معدل درجة الحرارة في ماء قشرة الخزان، الكسب الحراري للمجمع الشمسي، الحرارة المنتقلة من ماء الملف الى ماء القشرة، كفاءة المجمع، الفعالية الحرارية للمبادل الحراري، وهبوط الضغط. تم دراسة هذه المتغيرات عند اربع قيم لمعدل جريان ماء التدوير (1.8، 3، 6، و 9 لتر/دقيقة) ولنموذجي صرف من ماء التجهيز للمستهلك وهما نموذج عدم سحب الماء، والآخر صرف الماء بمعدل 1لتر/دقيقة وبصورة مستمرة. بينت النتائج وجود تراصف حراري أقوى في الخزان في حالة عدم السحب مقارنة بحالة السحب، وان معدل درجة حرارة ماء الخزان تتزايد مع تقدم ساعات النهار. تتزايد كفاءة المجمع الشمسي مع زيادة معدل جريان ماء التدوير، وتزداد في حالة سحب الماء من الخزان عما هو عليه في حالة عدم السحب. يقل هبوط ضغط ماء التدوير مع زيادة قيمة الأشعاع الشمسي عمليا ونظريا".