research centers


Search results: Found 4

Listing 1 - 4 of 4
Sort by

Article
Pressure - Settlement Characteristics of Shallow Foundations using Finite Element Method

Authors: Hend Jamal Maulood --- Adnan Jayed Zedan
Journal: Tikrit Journal of Engineering Sciences مجلة تكريت للعلوم الهندسية ISSN: 1813162X 23127589 Year: 2017 Volume: 24 Issue: 1 Pages: 25-37
Publisher: Tikrit University جامعة تكريت

Loading...
Loading...
Abstract

The present study attempts to represent the behavior of shallow foundations under the effect of eccentric inclined loading in terms of the main criteria of design which are the ultimate bearing capacity, permissible settlement, horizontal displacement and tilt. Due to the square shape of the analysed foundations, three dimensional finite element analysis are used. Elastic-perfectly plastic behavior of soil and rigid of foundations was adopted using Mohr-Coulomb criterion, 15-Node wedge elements were used to model and represent the soil and 5-Node linear elements with three degree of freedom to model and represent the foundations in used program PLAXIS 3D TUNNEL version 1.2. The results of analysis were presented in the form of pressure-settlement, pressure-horizontal displacement and pressure-tilt characteristics. Then the ultimate bearing capacity of the foundations were gotten and compared with (Meyerhof, 1956) and (Saran & Agrawal, 1991), a good agreement was found between them. Using the data obtained from the analysis, non-dimensional correlations have been developed for predicting the values of settlement, horizontal displacement and tilt of eccentrically-obliquely loaded foundations. These relationships can be used by the engineers.


Article
Experimental Study of a Strip Footing under Inclined and Eccentric Load on Geogrid Reinforced Sandy soil

Authors: Mohammed A. Al-Zandi --- Jawdat K. Abbas
Journal: Tikrit Journal of Engineering Sciences مجلة تكريت للعلوم الهندسية ISSN: 1813162X 23127589 Year: 2017 Volume: 24 Issue: 1 Pages: 70-80
Publisher: Tikrit University جامعة تكريت

Loading...
Loading...
Abstract

This study investigates the "bearing capacity" of a strip footing subjected to inclined and "eccentric load" on geogrid reinforced sandy soil by using physical modeling. The effect of each of the "depth ratio" of the first sheet of reinforcement, the vertical space ratio between consecutive sheets, number of reinforcement sheets, and the effective "depth ratio" of reinforcement on the "bearing capacity" were investigated. Also, the combined effect of load inclination angle, eccentricity ratio of the load and the relative density on the ultimate "bearing capacity" were studied. The results illustrated that by increasing the number of reinforcement sheets, the "bearing capacity" increased, but there is an optimum value (4-5). The optimum "depth ratio" of the first sheet of reinforcement was 0.35B. The optimum vertical space ratio between consecutive sheets was 0.25B. Using a test results with helping a statically analysis software program, a new easy and reliable empirical equation for computing the ultimate "bearing capacity" of the strip footing subject to inclined and eccentric load supported on geogrid reinforced sandy soil was developed.


Article
Behavior of Square Footing Subjected to Gypseous Soil under
تصرف الأساس المربع المستند على تربة جبسية تحت الأحمال المائلة اللامركزية

Journal: Tikrit Journal of Engineering Sciences مجلة تكريت للعلوم الهندسية ISSN: 1813162X 23127589 Year: 2013 Volume: 20 Issue: 3 Pages: 1-15
Publisher: Tikrit University جامعة تكريت

Loading...
Loading...
Abstract

n this study the behavior of square footing on gypsum soil is studied under inclined and eccentric loads via fabrication of a simulator of square footing (100 mm * 100 mm), fabrication of load tester and putting the soil in a box having a dimensions of (900 mm * 900 mm * 600 mm). A sample of soil is taken from Tikrit University in Salah Al Din province under 3 m depth which has a gypsum content of (50.48 %). The load test is performed on square footing at eccentricity of (e/B= 0, 0.1, 0.2 and 0.3) and an angle of inclination of the impacted load with the column ( i= 0°, 5°, 10°, 15°and 20°). The local specifications of the soil are measured (density, moisture, maximum density and ideal moisture), it is found that that the vertical falling, horizontal displacement, and base inclination increases with the increasing of eccentricity and inclination of impacted load, the soil resistance is less than the theoretical results for previous researchers in vertical load whereas it is approaching the theoretical results in inclined load. It is also observed that soil resistance decreases with the increasing of eccentricity of impacted load at local density and humidity, whereas it approaches the theoretical results at maximum density, ideal moisture and vertical load conditions and gives results higher than that of theoretical analysis in inclined load where it decreases with increasing the eccentricity of impacted load.It is found that a high settlement occur in footing when a water (unsaturated with gypsum salts) diffuses through the soil, then gypsum become soluble thereby the soil resistance decreases because of rupturing of chemical bond between gypsum and soil.

تضمن هذا البحث دراسة تصرف الأساس المربع المستند على تربة جبسيه والمعرض لأحمال مائلة ولامركزية من خلال تصنيع نموذج للأساس المربع بأبعاد (100mm x 100mm) وتصنيع جهاز فحص التحميل و وضع التربة في صندوق بأبعاد (900mm x 900mm x 600mm).أخذت التربة من موقع جامعة تكريت في محافظة صلاح الدين وعلى عمق 3 أمتار من مستوى سطح الأرض وكانت ذات محتوى جبسي عالي (50.48%). اجري فحص التحميل على الأساس عند لامركزية (e/B=0.0, 0.1, 0.2 and 0.3) وزاوية ميل للحمل المسلط مع العمود (i= 00, 50, 100, 150 and 200). أخذت كثافة التربة الحقلية والرطوبة الحقلية وكذلك الكثافة العظمى والرطوبة المثلى والكثافة العظمى والرطوبة الحقلية إذ وجد أن الهبوط العمودي والإزاحة الأفقية وميلان الأساس تزداد مع زيادة لامركزية وميلان الحمل المسلط وان قابلية تحمل التربة كانت اقل من النتائج النظرية لباحثين سابقين عندما كان الحمل عموديا ونتائج مقاربة من النتائج النظرية عندما كان الحمل مائلا في حالة الكثافة الحقلية والرطوبة الحقلية وتقل قيمة قابلية تحمل التربة مع زيادة لامركزية الحمل المسلط بسبب صغر المساحة الفعالة للأساس. أما في حالة الكثافة العظمى والرطوبة المثلى فوجد أن قابلية تحمل التربة كانت مقاربة للنتائج النظرية عندما كان الحمل عموديا ونتائج أعلى من النتائج النظرية عندما كان الحمل مائلاً ثم تقل هذه النتائج مع زيادة اللامركزية للحمل المسلط. وعند استخدام الكثافة العظمى والرطوبة الحقلية كان تأثير اللامركزية وميلان الحمل قليلا و قابلية تحمل التربة كانت عالية جدا وأعلى من النتائج النظرية. وعند غمر التربة الجبسيه بالماء يؤدي إلى حصول هبوط عالٍ في الأساس بسبب تحلل الجبس وتقليل قابلية تحمل التربة كثيرا بسبب تحطم الآصرة الكيميائية بين الجبس والتربة.


Article
Experimental Study of Rectangular Footing under Inclined and Eccentric load on Geogried Reinforced Sand
دراسة تجريبية لأساس مستطيل تحت حمل مائل ولا مركزي على رمل مسلح بالمشبكات الأرضية

Authors: Nasr A. Hasan --- Jawdat K. Abbas
Journal: Muthanna Journal of Engineering and Technology(MJET) مجلة المثنى للهندسة والتكنولوجيا ISSN: 25720317 25720325 Year: 2017 Volume: 5 Issue: 3 Pages: 87-94
Publisher: Al-Muthanna University جامعة المثنى

Loading...
Loading...
Abstract

This study investigates the behavior of a rectangular footing subjected to inclined and eccentric load on geo-grid reinforced sand by using laboratory modeling. Small model was used to simulate the behavior of rectangular surface footings (length to width ratios of the footings were equal to 1, 1.25, and 1.5). The effect of the eccentricity and inclination of applied load on the bearing capacity, settlement, horizontal displacement and tilt were investigated. The load eccentricity varies from (0, 0.05B, 0.1B to 0.15B) and the load inclination varies from (00, 50, 100, 150) . The dry sand is reinforced by multiple layers (1, 2, 3, 4 and 5) of Geo-grid. The results illustrated that by increasing the number of reinforcement layers, the bearing capacity increased, but there is an optimum value (5). In general, for central, inclination and eccentricity loading the results indicated that by increasing the number of reinforcement layers (N) the bearing capacity increased while settlement, horizontal displacement and tilt decreased.

تستكشف هذه الدراسة قابلية التحمل لأساس مستطيل خاضعة لحمل مائل ولا مركزي على رمال مسلح بمشبكات أرضية باستخدام نموذج مختبري. تم استخدام نموذج صغير لمحاكاة سلوك الأسس السطحية المستطيلة (كانت نسب الطول إلى العرض لأسس تساوي 1، 1.25، 1.5). تأثير ألامركزية وميلان الحمل المسلط على قابلية التحمل والهبوط و الإزاحة الأفقية وميلان الأساس تم استكشافها. تم تسليح الرمل بعدة طبقات من المشبكات الأرضية (1،2،3،4،5). اللامركزية في الحمل المسلط تتغير من (0.01B ، 0.1B الى 0.15B) وان ميلان الحمل المسلط يتغير من ( 00، 50، 100 الى 150). أظهرت النتائج بزيادة عدد طبقات التسليح تزداد قابلية التحمل ولكن هنالك قيمة مثلى لعدد طبقات التسليح وهي (5). بصوره عامة ولحمل مركزي أو لا مركزي أو مائل فان زيادة عدد طبقات التسليح يزيد من قابلية التحمل ويقلل من الهبوط و الإزاحة الأفقية وميلان الأساس .

Listing 1 - 4 of 4
Sort by
Narrow your search

Resource type

article (4)


Language

English (4)


Year
From To Submit

2017 (3)

2013 (1)