Article
A study of the Effect of Air Inlet and Exit on Indoor Air Movement
دراسة تأثير مدخل ومخرج الهواء على حركة الهواء داخل غرفه

Loading...
Loading...
Abstract

This work consists of a numerical simulation to predict the velocity and temperature distributions, and an experimental work to visualize the air flow in a room model. The numerical work is based on non-isothermal, incompressible, three dimensional, turbulence model, and solved using a computational fluid dynamic (CFD) approach, involving finite volume technique to solve continuity, momentum and energy equations, that governs the room’s turbulent flow domain. The experimental study was performed using (1/5) scaled room model of the actual dimensions of the room to simulate room air flow and visualize the flow pattern using smoke generated from burnt herbs and collected in a smoke generator to delivered through the prototype room. The numerical results were compared with those obtained from experiments, the correspondence between numerical and experimental was fairly good and also, a fair comparison was found with other workers in this field.

يهدف هذا البحث الى تحسين المعرفة ببعض الوسائل التي يمكن ان تستخدم في حساب توزيع السرع ودرجات الحرارة واظهار هيئه جريان الهواء خلال الفضاء المكيف للغرفه وهذه الخطوه لايمكن الاستغناء عنها عند تصميم انظمة تكييف بنوعيه جيدة. تضمنت الدراسه اجراء محاكاة عدديه لحساب توزيعات السرع ودرجات الحراره وعمل تجريبي لاظهار هيئه جريان الهواء في انموذج الغرفه. المحاكاة العدديه للجريان اعتمدت على انموذج الجريان ثلاثي الابعاد المضطرب غير المنضغط وبدرجات حراره مختلفه وباسلوب المعادلتين واستخدم في الحل احدى طرائق ديناميك الموائع الحسابي. اجريت الدراسه التجريبيه على انموذج مصغر لغرفه صمم ونفذ خلال هذه الدراسه وفق معامل قياس مناسب 15 لمحاكاة جريان الهواء للفضاء الحقيقي (الغرفه) لاظهار هيئه الجريان باستخدام دخان منتج من احتراق حبوب نباتيه يجمع في مولد دخان و يوجه الى انموذج الغرفه. مقارنة النتائج العدديه مع النتائج التجريبيه ومع نتائج باحثين اخرين اظهرت توافق مقبول.


Article
Indoor Air Concentrations of Heavy Metals in Two Shisha Smoke Cafés in Baghdad
تراكيز المعادن الثقيله للهواء الداخلي في مقهيين لتدخين الشيشه في بغداد

Loading...
Loading...
Abstract

Shisha smoke represents one of the causes of indoor air pollution. Heavy metals represent the main components in shisha smoke. In this research study, the indoor concentrations of heavy metals in shisha smoke café sites was investigated, samples were taken from two café sites (site1, site 2) which differ in their volume. Site1 volume was 77m3, while site 2 was 437.5m3. Sample were taken by using a low volume sampler (sniffer), and then examined by the Atomic Absorption Spectrometry (AAS). The results showed that indoor air shisha smoke samples for both experimental sites have shown a significant amount of heavy metals as compared with control sampling values. The mean concentration values of (Pb, Zn, Co, Ni, Cr) in site 1 were (11.004, 9.544, 24.088, 19.84, 24.98 µg/m3) respectively, while the mean concentration values of these heavy metal in site 2 were (5.574, 6.578, 16.684, 26.114, 9.636 µg/m3) respectively. Results and conclusions referred those indoor air concentrations during shisha smoking times were high and exceed the WHO standard limits.

يعد دخان الشيشه احد مسببات تلوث الهواء الداخلي , وتمثل المعادن الثقيله احدى اهم مكونات دخان الشيشه . تم التحري في هذه الدراسه البحثيه عن تراكيز المعادن الثقيله للهواء الداخلي في مقهيين (موقع 1,موقع 2) واللذان يختلفان في حجم الصاله الداخليه ,كان الحجم الداخلي لصاله المقهى الاول 77م3 وكان الحجم الداخلي لصاله المقهى الثاني 437,5 م3. تم استخدام جهاز اخذ نماذج الهواء قليله الحجم (sniffer) ثم تم فحص النماذج باستخدام جهاز التحليل الطيفي للامتصاص الذري (AAS) . اشارت النتائج الى ان نماذج دخان الشيشه في كلا الموقعيين سجلت زياده معنويه في تراكيز المعادن الثقيله مقارنه بقيم نماذج السيطره , وكانت معدلات تراكيز العناصر(Pb, Zn, Co, Ni, Cr) للموقع الاول كانت (11.004, 9.544, 24.088, 19.84, 24.98 µg/m3)على التوالي , بينما كانت معدلات التراكيز لتلك العناصر في الموقع الثاني (5.574, 6.578, 16.684, 26.114, 9.636 µg/m3) على التوالي. ان هذه النتائج تشير بشكل واضح الى ان الهواء الداخلي لصالات المقاهي خلال اوقات اشغالها من قبل مدخني الشيشه يمتلك تراكيز عاليه للمعادن الثقيله , وان هذه التراكيز تفوق التراكيز القياسيه المحدده من قبل منظمه الصحه العالميه.


Article
Vehicle Indoor Air pollution with Fungi Generated by Air Conditioning Systems (AC) and Treatment by Using Aqueous Extracts Mushroom (Ganoderma lucidum)
تلوث الهواء الداخلي للسيارات بالفطريات المتولده في انظمه تكييف الهواء ومعالجته باستخدام المستخلص المائي للفطر Ganoderma lucidum

Authors: Nada Abdulrahman F. Al-Easawi ندى عبد الرحمن فليح العيساوي --- Rusol M. Al-Bahrani رسل محمد البحراني
Journal: Iraqi Journal of Science المجلة العراقية للعلوم ISSN: 00672904/23121637 Year: 2016 Volume: 57 Issue: 2B Pages: 1096-1102
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

Vehicle Air Conditioning (AC) systems are used in countries that suffer high temperature degrees during the summer season, one of these countries is Iraq. Most passengers suffer manifestations which may lead to Allergic or Respiratory diseases as they inhale polluted air produced by AC systems.In this study 10 vehicle were selected randomly on the basis of noxious odors emitted from AC systems. Indoor air samples were collected by using impaction method and using Sabouraud's dextrose agar to grow and isolate dominant fungi species accompanied with AC polluted air. Dust particle diameters aggregated in AC filters were measured because the particles work as transporters to carry fungi then get inhaled by the passengers. After isolating and identifying air fungi, frequency, occurrences percentage calculated. The Ganoderma lucidum extract was used as inhibitor agent and antifungal growth by using different concentrations: (10, 15, 20, 25) mg/ml. The results showed that the dominant species air fungi related to AC systems are: Aspergillus niger, Aspergillus flavus, Penicillium and Rhizopus . The highest occurrences percent 80%, and highest frequency percent 33.3% was recorded to Aspergillus niger ,while the lowest occurrences percent 30%, and lowest frequency percent 12.5% was records to Rhizopus . Microscopic examination for dust particles showed that the particles size ranged between (1 µm to 10 µm), and the highest distribution percentage was 43% for particles of less than 5µm in size which are respirable and can cause allergic and respiratory diseases .The Ganoderma lucidum in concentration of 25mg/ml have highly inhibition zone than other concentrations .

تستخدم انظمه تكييف هواء السيارات بنسبه عاليه في البلدان التي تعاني من ارتفاع درجات الحراره صيفا ومنها العراق.ويعاني العديد من ركاب السيارات اعراض قد تقود الى امراض تحسسيه او تنفسيه بسبب استنشاقها للهواء الملوث المنبعث من تلك المكيفات. في هذه الدراسه البحثيه تم اختيار 10 سيارات بصوره عشوائيه بالاعتماد على ماتطلقه من رائحه هواء غير مرغوبة بعد تشغيل مكيف الهواء , تمت نمذجة الهواء الداخلي للسياره باستخدام وسط ال Sabouraud's dextrose agar باستخدام طريقه الطمر لاقتناص وتنميه وعزل انواع الفطريات السائده في هواء التبريد. تم قياس اقطار دقائق الغبار المتجمع في مرشح المكيف على اعتبار ان هذه الدقائق تعمل كنواقل للفطريات والتي تستنشق من قبل الركاب. بعد عزل وتشخيص الانواع السائده وحساب نسبه الظهور والتردد لكل نوع استخدم مستخلص فطر ال Ganoderma lucidum و الذي يمتلك فاعلية معروفه ضد الامراض المختلفه كماده مثبطه لنمو الانواع السائده من الفطريات المعزوله باستخدام تراكيز مختلفه من ذلك المستخلص وهي: (10,15,20,25).ملغم/مل. اظهرت النتائج سياده Aspergillus niger, Aspergillus flavus, Penicillium , Rhizopusوباعلى نسبه ظهور 80% واعلى نسبه تردد 33.3% للنوع Aspergillus nigerوكانت اقل نسبه ظهور 30% واقل نسبه تردد 12.5% هي للنوع Rhizopus وقد وجد من خلال الفحص المجهري بأن احجام دقائق الغبار المفحوصه تتراوح بين (1 µm -10 µm ) , كما كان اعلى توزيع نسبي هو 43% لاقطار الدقائق الاقل من µm5 وهي دقائق قابله لللاستنشاق لتحدث امراضاً تنفسية وتحسسية. وقد بينت النتائج بان مستخلص الفطر Ganoderma lucidumعندما يكون تركيزه25ملغم/مل يكون ذو فاعلية تثبيطيه عاليه مقارنه بالتراكيز الاخرى .


Article
The Relation Between Fungi Isolated from Higher Respiratory Tract of Allergic and Asthmatic Patients, and Air Fungi in their Residence
العلاقة بين الفطريات المعزولة من القناة التنفسية العليا لمرضى الحساسية والربو والفطريات في مناطق سكناهم

Loading...
Loading...
Abstract

Twenty five sputum and throat swabs were collected from 25 asthma and bronchial allergic patients from Allergy and asthma Centre Governorate of Basra/Iraq beside 25 indoor air samples from their houses. Another 25 samples were collected from normal individual and from their indoor air.These Samples were cultured on Sabouraud dextrose agar at 25 and 37Co,seventeen genera were identified in patient samples and (23) genera in their indoor air samples while 4and5 species were identified from normal individual and from their indoor air samples respectively beside yeast colonies and sterile mycelium were recorded in all samples.Hyphomycetes are the dominant group in all tested samples, it was 67.5% in patient samples, and %75.38 in their indoor air samples beside 66.66% and 81.25% in normal individual and in their indoor air samples respectively. The prominence value of yeasts was 735.66 in patient samples and 69.86 in their indoor air samples while it was 546.62 and 405.69 in the normal individuals and in their indoor air samples respectively. According to the filamentous isolates, the genera Aspergillus, Penicillium, Alternaria, Ulocladium, Paecilomyces, and Cladosporium have the highest prominence value in the patients samples and in their indoor air samples. In normal individuals, Aspergillus and sterile mycelium showed the highest prominence value and Penicillium, Aspergillus, Cladosporium and Ulocladium in their indoor air samples.

جمعت 25 عينة قشع ومسحة حنجرة من خمسة وعشرين فردا يعانون من أعراض الربو والحساسية ويراجعون مركز الحساسية والربو في محافظة البصرة/ العراق وكذلك جمعت 25 عينة هواء من داخل بيوت الأشخاص أنفسهم. بالإضافة إلى عدد مماثل من العينات من أفراد طبيعيين لا يشكون من أعراض الربو والحساسية ومن هواء داخل بيوتهم. زُرعت العينات على وسط Sabauroud dextrose agar وبمكررين لكل عينة، تم التحضن على 25 و37 درجة مئوية وتم تشخيص (17) جنسا فطريا خيطيا من عينات المرضى و(23) جنسا من هواء بيوتهم، أما الأفراد الطبيعيون فقد عزل من عيناتهم (4) أجناس ومن هواء داخل بيوتهم (8) اجناس فضلا عن الخمائر والخيوط الفطرية العقيمة Sterile mycelium التي ظهرت في جميع العينات.كانت قيمة prominence value للخمائر 735,66 في عينات المرضى و69,86 في الهواء داخل بيوتهم في حين كان 546,6 و405,69 في الأفراد الطبيعيين وهواء داخل بيوتهم. أما العزلات الفطرية الخيطية فقد كان للـ Aspergillus وPenicillium وAlternaria و Ulocladium و Paecilomyces وCladosporium أعلى قيمة تفوق في عينات المرضى وهواء داخل بيوتهم. وكان Aspergillus والخيوط الفطرية العقيمة المستوى الأعلى في عينات الأفراد الطبيعيين والأجناس Penicillium و Aspergillus وCladosporium وUlocladium المستوى الأعلى في هواء داخل بيوتهم. كانت الفطريات السائدة Hyphomycetes في جميع العينات وكانت نسبتها 67% في عينات المرضى و75% في عينات هواء بيوتهم، وكانت 67% في عينات الأفراد الطبيعيين و81 % في عينات هواء بيوتهم.


Article
AIR TEMPERATURE DISTRBUSION AND CONTAMMINATE CONCENTRATION IN LABORATORY UNDER IRAQI CLIMATE
تأثير مواقع السحب على توزيع درجات الحرارة وتركيز الملوثات داخل حيز مختبر عند ظروف المناخ العراقية

Loading...
Loading...
Abstract

Ventilation is the main performance requirement in laboratory design as it has to guarantee a safe and comfortable indoor environment. standards and guidelines on laboratory ventilation often impose high ventilation rates, increasing the energy need for ventilation. This research focuses on the steady-state distribution of temperature and contaminate concentrations in a real environment which was a function of several factors such as the position of air exhausts. Here several different exhaust locations were investigated to determine the optimum exhaust positions. In this study, CO2 is used as an indicator of the concentration of pollutants inside tested room.Room concentration patterns for a laboratory were simulated with computational fluid dynamics (CFD) simulations by using (FLUINT6.3.26) and (GAMBIT V.2.4.6) computer programs for various exhaust locations. The computational results were validated with design data due to Iraqi cooling code (setup temperature and temperature difference from head to foot level). The numerical results showed that the exhaust grills located near the ceiling resulted in lower pollutant concentrations than the corresponding exhausts near the floor.

تعتبر التهوية احد المتطلبات الرئيسية عند تكييف الهواء في تصميم المختبرات لضمان بيئة داخلية أمنة ومريحة. غالبا ما تفترض المعايير والتوجيهات الحالية وجوب تجهيز معدلات تهوية عالية في المختبر مما يؤدي الى زيادة الطاقة المستخدمة للتهوية. في هذا البحث تم التركيز على توزيع درجات الحرارة والملوثات في الحالة المستقرة داخل بيئة حقيقية معتمدة على عدة عوامل ومنها موقع منافذ سحب الهواء. تم دراسة مواقع مختلفة لمنافذ سحب الهواء لتحديد موقع السحب المثالي . كذلك استخدم غاز ثاني اوكسيد الكربون كمؤشر لتركيز الملوثات داخل حيز الاختبار . استخدم برامج الحاسوب (FLUINT6.3.26) و (GAMBIT2.4.6) لمحاكاة وتحليل انماط توزيع الملوث لمختلف مواقع السحب .تم التحقق من صحة النتائج من خلال مقارنتها مع القيم التصميمية الموجودة في المدونة العراقية للتبريد (الحرارة التصميمية, فرق درجات الحرارة بين مستوى الراس والقدم).اظهرت النتائج العددية ان مواقع السحب بالقرب من السقف تعطي توزيع ملوثات اقل تركيزا مما لو كانت بالقرب من مستوى أرضية الحيز.


Article
A COMPUTATIONAL AND EXPERIMENTAL INVESTIGATION OF AIR FLOW AND CONTAMINANTS CONCENTRATION IN A LABORATORY WITH MIXING VENTILATION SYSTEM

Authors: Ala'a A. Mahdi --- Mohammed W. Khadim --- Ammar A. Mohammed Hassn
Journal: KUFA JOURNAL OF ENGINEERING مجلة الكوفة الهندسية ISSN: 25230018 Year: 2018 Volume: 9 Issue: 3 Pages: 201-222
Publisher: University of Kufa جامعة الكوفة

Loading...
Loading...
Abstract

In this research an experimental and computational analysis under Iraqi climate of temperature distribution, velocity and contaminants concentration in the air-conditioned laboratory have been studied for two case studies. Case-I chosen internal combustion engine laboratory of dimensions (10.3 x 8.7 x 3.75) m with a different number of engines used in the experiments and Case-II chosen laboratory of chemical and petroleum products dimensions (3.7x3.6x3.3)m with different locations of the supply air terminal diffuser compared to the existing design situation. ANSYS FLUENT 14 used to simulate the model's laboratories for compared between the present practical work and numerical work results which are acquired by using RNG K-ε and SST k-ω models and found that the SST k-ω model more accurate. The SST (k-w) turbulence model were employed to solve the governing equations numerically with Reynold number 28,933 and validated by comparing the numerical results with experimental data, and this comparison gives a good agreement. The numerical results for case-I compared with experimental data, while for case-II, the numerical results compared with the standard value due to Iraqi cooling code and ASHRAE standards. The results showed that the mixing ventilation system is able to remove various types of pollutants effectively up to 90% in addition to providing human thermal comfort conditions with the effectively of heat removal up to 85% for the state of the internal combustion laboratory. The second case at laboratory of chemical and petroleum products when the supply air terminal diffuser in the same side, the results showed an increase in comfort conditions by up to 40%.Lastly, from the research, it was found that the pollutant transportation and distribution depend in general upon several factors such as type and location of contaminant source, building geometry, the arrangement of air terminal diffuser opening, and thermal/fluid boundary conditions for example flow rate. Numerical simulation of the velocity and diffusion fields in a conventional flow in laboratories is very useful in comprehending flow and diffusion patterns within different changes of the flow conditions.


Article
Determination of Radon Concentration and the Annual Effective Dose in Karbala University Campus, Karbala, Iraq

Author: Abbas J. Al-saadi
Journal: Karbala Journal of Medicine مجلة كربلاء الطبية ISSN: 19905483 Year: 2013 Volume: 6 Issue: 1 Pages: 1591-1599
Publisher: Kerbala University جامعة كربلاء

Loading...
Loading...
Abstract

determination of radon gas concentrations in multistory buildings and outdoor in the Karbala University campus (Karbala-Iraq) were carried out by using Solid-state nuclear track detector (CR-39).The detectors were distributed over 20places(14 indoor and others outdoor). The area of the study includes College of Medicine, College of Dentistry, College of Pharmacy, College of Sciences, student's residence and the Central Library. The dosimetric measurements were made over a period of 3 months.(from 15 September to 14 December 2012). After exposure, the detectors were etched in a (NaOH) solution of normality (6.25 N) at temperature of 70 oC for 3 hours. The tracks were counted by the microscope track-counting system. The indoor radon gas concentrations were found to vary from 41.881 ± 2.463Bq/m3 to 95.642 ± 5.730 Bq/m3 with an average value and standard deviation of 70.358 Bq/m3and14.367Bq/m3 respectively. The outdoor air radon concentrations are ranged from 25.134 ± 1.783Bq/m3 to 28.594 ± 2.854Bq/m3 with an average value of 26.974 Bq/m3and standard deviation 1.155 Bq/m3. In the survey of radon concentration in multistory buildings was observed that the upper floor have lower radon concentration than the ground floor. It has found that, in general, the radon level in lower floors is higher than that in upper ones in all buildings. The annual effective dose to the population from the inhalation of radon was also estimated and this varied from 1.056 ± 0.062mSv/ y to 2.412 ± 0.144mSv/ y, with an average of1.774 mSv/y and standard deviation is 0.362mSv/ y. The ratio between indoor and outdoor radon concentration (mean value) in this study was about 3.The radon concentrations were found to be lower than the higher level recommended by ICRP ( 200 Bq/m3) and thus are within safe limits.


Article
INVESTIGATING INDOOR AIR QUALITY AND THERMAL COMFORT USING DIFFERENT VENTILATION SYSTEMS UNDER IRAQI CLIMATE
استقصاء نوعية هواء الغرفة والراحة الحرارية للشاغلين باستخدام منظومات تهوية مختلفة عند ظروف الاجواء العراقية

Loading...
Loading...
Abstract

Computational Fluid Dynamics (CFD) of indoor environment as well as quality considerations are important element in the study of energy consumption, thermal comfort and indoor air quality in buildings. This paper investigate a comparison work between impinging jet, displacement, and mixing ventilation systems for an isothermal and non-isothermal ventilated room for Indoor Air Quality (IAQ) and thermal human comfort under Iraqi climate. For IJV system, draught discomfort is the issue of most concern since it supplies cooled air directly to the occupied zone. This study investigated a number of factors influencing draught discomfort and temperature stratification in an office environment. The considered factors, supply airflow rate and supply air temperature. RNG K-Ɛ turbulence model was used with the turbulent flow. The second aspect included numerical analyses by adopting ANSYS FLUENT15 code to generate simulation models. A square shaped air supply device was used with [0.1 times room height (h)] outlet terminal height from the foot level end. The IJV system proved more efficient than displacement and mixing ventilation systems. The Air Distribution Performance Index (ADPI) obtained for an isothermal and non-isothermal ventilated room adopting IJV system gave best values (0.80, 0.83) respectively compared with the other two ventilation systems.

يعتبر استخدام محاكاة ديناميك الموائع لاستقصاء البيئة الداخلية ونوعية هواء الحيز المشغول من المواضيع المهمة المطبقة حديثا في دراسات استهلاك الطاقة والراحة الحرارية للشاغلين ونوعية هواء الغرفة. تقدم الدراسة الحالية أسلوب مقارنه بين ثلاثة أنواع من منظومات التهوية الشائعة الاستخدام (نظام تهوية البثق المؤثر , نظام التهوية الازاحيه , ونظام التهوية المختلط) لنوعين من الغرف المكتبية , الأولى غرفه معزولة حراريا والثانية غرفه غير معزله حراريا لتحديد ايهم افضل عند حساب نوعية هواء الغرفة منظومة التهوية بأسلوب البثق المؤثر استخدمت مجرى تجهيز هواء ذو مقطع عرضي مربع الشكل وكان بعد فتحة تجهيز الهواء للغرفة عن أرضية الغرفة يساوي (0.1h) . أظهرت النتائج ان أسلوب التهوية باستخدام نظام البثق المؤثر أفضل من المنظومات الأخرى من خلال حساب كفاءة التهوية وحساب مؤشر أداء توزيع الهواء .


Article
Estimation Of Radon-222 Concentrations In A Residential Area In Baghdad City

Authors: Ahmed H.Ali --- Baha` ElDin Ma`ro --- Salam J. AlMaliky
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2010 Volume: 16 Issue: 4 Pages: 6064 -6070
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

Airborne radioactive particulates (for both indoor and outdoor air), in Al-Jaderiya region (Baghdad), have been collected to measure the concentration of Radon-222 daughter products of gamma ray emission (214Pb, 214Bi and 218Po) and hence calculate the concentration of Radon-222. 24 samples were analyzed (12 indoor and others outdoor), using gamma ray spectrometric system based on a High purity Germanium detector (HpGe) of (40%) efficiency. The average concentrations of Radon-222, were found to be (93.7 Bq/m3) and (18.9 Bq/m3), in indoor and outdoor air respectively. The comparison of these concentrations with some internationally typical values has showed that the concentrations of Radon-222 are higher in outdoor air of the area of study compared with many regions in USA and other countries. On the contrary, the concentrations of Radon-222 in indoor air of the area of study are less than those in many European countries.

تم جمع نماذج الهواء للدقائق المشعة العالقة في ألجو (الداخلي و الخارجي) في منطقة الجادرية (بغداد) لغرض قياس تراكيز نواتج انحلال الرادون-222 الباعثة لأشعة جاما ( ألرصاص-214، ألبزموث- 214 و البولونيوم- 218) و من ثم حساب تركيز الرادون-222. تم تحليل (24) نموذجا، (12 منها للهواء الداخلي و البقية للهواء الخارجي)، باستخدام منظومة تحليل أطياف جاما عالية النقاوة مستندة على عداد جرمانيوم نقي ذي كفاءة(40%). اظهرت النتائج ان معدل تراكيز الرادون-222 في الهواء الداخلي و الخارجي هي ) 93.7 بكريل/م3) و ) 18.9 بكريل/م3) على التوالي. ان مقارنة تلك النتائج مع مثيلاتها على المستوى العالمي تظهر ان تراكيز الرادون-222 في الهواء الخارجي لمنطقة الدراسة اعلى من قيمها في عدد من مناطق الولايات المتحدة الامريكية و دول اخرى. على العكس من ذلك، فقد كانت تراكيز الرادون-222 في الهواء الداخلي اقل من قيمها في العديد من الدول الاوربية .