research centers


Search results: Found 46

Listing 1 - 10 of 46 << page
of 5
>>
Sort by

Article
Estimation of Land Surface Temperature using MODIS Thermal Infrared and weather station Data in Iraq
تخمين درجة حرارة سطح الارض بأستخدام معطيات كل من القمر موديس ضمن المدى الحراري و المحطات الارضية لقياس المتغيرات المناخية في العراق

Authors: مالك رشيد عباس --- 1بهارين بن أحمد
Journal: journal of kerbala university مجلة جامعة كربلاء ISSN: 18130410 Year: 2014 Volume: 12 Issue: 3 Pages: 113-118
Publisher: Kerbala University جامعة كربلاء

Loading...
Loading...
Abstract

Recently Iraq experienced many environmental problems, caused by global climate changes. Therefore, it is important to monitor the real change in temperature. In order to achieve this goal, it requires a very large network of ground stations. MOD11A1 product is a tile of daily LST product (land surface temperature) at 1 km spatial resolution with a reasonable accuracy that needs to be improved. By a statistical model that relates ground truth temperature with result of LST from MODIS data it is possible to generate a correction algorithm. Lumping all daily average data of six Iraqi cities over three years a regression line that correlate، daily average truth ground temperature (TG) with daily average LST obtained from MODIS data. This correlation can be used to get a better estimation to the average daily truth temperature for any area within 1 km2 resolution in Iraq region for any given MODIS average daily LST of this area.

يعاني العراق وخصوصا في الفترة الأخيرة من مشاكل بيئية عدة، متأثرا بالتغيرات البيئية العالمية. لذلك توجد ضرورة لمراقبة التغيرات في درجة الحرارة. ولتحقيق هذا الهدف ينبغي توفر شبكة كبيرة من المحطات الأرضية لقياس الحرارة. يوفر منتج القمر الصناعي موديس (MOD11A1) معطيات على المستوى اليومي لدرجة حرارة سطح الأرض لأرض العراق وأن أصغر مساحة يتحسس درجة حرارتها القمر موديس هي 1كم. أن دقة هذه القراءات ليست عالية جدا وتحتاج إلى طريقة تحسن من دقتها. يمكن تحسين هذه القراءات من خلال اعتماد موديل إحصائي وبخط انحدار يربط العلاقة بين قراءات القمر موديس مع قراءات حقيقية لمحطات قياس أرضية. تم في هذا البحث أعتماد قراءات معدلات حرارة يومية لستة مدن عراقية وعلى مدى ثلاث سنوات وبربطها بالقراءات المناظرة لها من معطيات القمر موديس والحصول على علاقة يمكن استخدامها للحصول على تخمين أفضل لدرجة الحرارة الحقيقية لأي بقعة في العراق من معرفة المعدل اليومي لدرجة حرارة سطح الأرض والمعطاة بواسطة القمر موديس.

Keywords

LST --- MODIS --- Thermal infrared.


Article
STUDY OF OPTICAL GAIN IN AlGaAs QUANTUM DOT PHOTODETECTOR
دراسة الربح الضوئي في الكاشف الضوئي المكون من النقاط الكمية الالمنيوم / غاليوم/ زرنيخ

Author: Hayder T. Assafli حيدر توران مهدي
Journal: DIYALA JOURNAL OF ENGINEERING SCIENCES مجلة ديالى للعلوم الهندسية ISSN: 19998716/26166909 Year: 2017 Volume: 10 Issue: 3 Pages: 86-95
Publisher: Diyala University جامعة ديالى

Loading...
Loading...
Abstract

The Quantum Dot Infrared Photo Detectors (QDIPs) become the leading technology in semiconductor detectors. This attraction comes from the properties of these devices that overpowers over the currently available detectors like Quantum Well Infrared Photo Detectors (QWIPs). In this paper, different Z-length dimensions are used to investigate the behavior of energy levels inside the quantum dots. The Z-length is also applied to investigate the shift of the operating wavelength and adjust the quantum dot performance by multiband Schroedinger-Poisson simulation. The generated electrons in the detection process are one of the most important properties of these dots. A software program is used to simulate the wave function, energy state, and absorption for different Z-dimensions. Results showed that the bandgap decreases and the absorption response shifts with increasing Z-dimension.

الكواشف التحت الحمراء المكونة من النقاط الكمية اصبحت في مقدمة كواشف الاشباه الموصلات والسبب يعود الى خصائص هذا النوع من الكواشف التي تعطيها مميزات اكثر من قريناتها مثل الكواشف التحت الحمراء ذات البئر الكمي. في هذا البحث, تم دراسة تأثير تغيير البعد Z للنقاط الكمية على مستويات الطاقة والتي بدورها تأثر على الاستجابة الضوئية للكاشف. وتم دراسة تأثير تغيير البعد Z على تغير استجابة الكاشف للطول الموجي بطريقة المحاكاة باستخدام طريقة شرودنكر- بويسون. ألالكترونات الناتجة مهمة جدا لاعطاء خواص النقاط الكمية. تم استخدام برنامج المحاكاة لتوليد دالة الموجة, مستويات الطاقة, وخواص الامتصاص. واظهرت النتائج ان فجوة الطاقة تقل والامتصاصية تزداد مع زيادة البعد Z.


Article
Theoretical Study of Vibration Spectroscopy for Neutral and Charged Fluoranthene Molecule
دراسة نظرية للطيف الاهتزازي لجزيئة الفلورانثين وجذريها الايونيين الموجب والسالب

Author: Manal O. Hamzah منال عبيد حمزة
Journal: Baghdad Science Journal مجلة بغداد للعلوم ISSN: 20788665 24117986 Year: 2011 Volume: 8 Issue: 2 Pages: 366-374
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

The vibration frequencies and infrared absorption intensities for the fluoranthene molecule (C16H10) and their positive and negative radical ions have been calculated using ab initio method according to the density functional theory (DFT) at the B3LYP / 6-311G basis set, in addition to PM3 semi-empirical quantum chemical method. Although, the importance of this molecule due to their presence in interstellar space and their environmental contaminating properties, the literatures miss to a complete classification for (3N-6) vibration modes and the vibration frequencies and infrared absorption intensities calculations for the negative radical ion. For these reasons our calculation and classification considered to be assignment. All calculated vibration frequencies rearrangement as the Hertzberg convention, then classified symmetrically and assigned by valence for (3N-6) modes depending on graphical pictures obtained by using Hyperchem program. Generally, the calculated vibration frequencies values showed a good agreement and compatible with values measured experimentally and those calculated by other theoretical methods.

تم حساب ترددات الاهتزاز الاساسية وشدد امتصاص الاشعة تحت الحمراء لجزيئة الفلورانثين (C16H10) وجذريها الايونيين الموجب و السالب باستخدام طريقة الحساب التام وفقا لنظرية دوال الكثافة Density Functional Theory (DFT) عند عناصر القاعدة ((6-311G وبأسلوب (B3LYP), فضلا عن أحدى طرائق ميكانيك الكم التقريبيةSemi-empirical method (PM3). وعلى الرغم من أهمية هذه الجزيئة كونها احد مصادر الاشعة تحت الحمراء المنبعثة في الاوساط الفضائية فضلا عن كونها مدرجة ضمن احد المصادر البيئية الخطرة لتلوث البيئة, تفتقر الادبيات للتصنيف المتكامل وبعدد(3N-6) , كما لم يتوفر في الادبيات ما يشير الى حساب ترددات الاهتزاز وشدة امتصاص الاشعة تحت الحمراء للجذر الايوني السالب لهذه الجزيئة, لذا يعد حسابنا وتصنيفنا لها تنبؤيا. تم ترتيب جميع ترددات الاهتزاز المحسوبة بحسب تقليد هيرتزبرغ كما تم تصنيفها تماثليا وتشخيصها تكافؤيا وبعدد (3N-6) اعتمادا على الاشكال البيانية التي تم الحصول عليها باستخدام برنامج Hyperchem. عموما كانت القيم العددية لترددات الاهتزاز التي نتجت عن الحساب جيدة و متوافقة مع القيم المقاسة تجريبيا وتلك المحسوبة بطرائق نظرية اخرى.


Article
Design and Fabrication of Narrow Band Infrared Detector
تصميم وتنفيذ كاشف للاشعة تحت الحمراء ذو استجابة طيفية ضيقة الحزمة

Author: Dr. Khalid Khalil Mohammad د. خالد خليل محمد
Journal: AL Rafdain Engineering Journal مجلة هندسة الرافدين ISSN: 18130526 Year: 2012 Volume: 20 Issue: 3 Pages: 15-25
Publisher: Mosul University جامعة الموصل

Loading...
Loading...
Abstract

AbstractMost of infrared detectors used in various electrical equipments have wide spectral response and usually needs front filter to prevent visible light from passing to the detector. This research is intended to study and fabricate an indium doped silicon (n) (In-Si) structure to achieve a photo detector working as narrowband infrared detector. The SCAPS program was used as a simulation tool in order to achieve the optimum structure design. Then the (In-Si) infrared detector was fabricated using vacuum evaporation deposition technique. The fabricated photodiode shows a narrowband spectral response at 940 nm. The results of the simulated and practical samples are comparable which gives a simple and cheap method for obtaining narrowband infrared detector.Keywords: silicon, infrared, photo detector.

الخلاصةان معظم كواشف الاشعة تحت الحمراء والمستخدمة في المعدات والاجهزة الكهربائية تكون ذات استجابة طيفية واسعة الحزمة وتمتد غالبا لتشمل الاطوال المرئية ولذا يوضع امامها مرشح ليمنع مرور هذه الاطوال الى الكاشف. في هذا البحث تمت دراسة و تصنيع بنية ثنائي ضوئي مصنوع من مادة السيليكون (n) المطعم بالانديوم للحصول على كاشف اشعة تحت الحمراء ذو عرض حزمة طيفية ضيقة. كما تم استخدام برنامج المحاكاة SCAPS لغرض الحصول على التصميم الامثل للنبيطة. ثم باستخدام تقنية الترسيب بالتبخير الفراغي تم الحصول على كاشف اشعة تحت الحمراء عمليا. ولقد اظهرت قياسات الاستجابة الطيفية للكاشف المنفذ عمليا استجابة طيفية ذات عرض حزمة ضيقة عند طول موجي 940 nm. كما واظهرت نتائج القياسات العملية ونتائج عملية المحاكاة الحاسوبية نتائج متقاربة وتم الحصول من خلالها على كاشف اشعة تحت حمراء بسيط ورخيص وذو عرض حزمة طيفية ضيقة.


Article
Making Plasmonic Pixels

Author: Stewart Wills
Journal: Iraqi Journal of Applied Physics المجلة العراقية للفيزياء التطبيقية ISSN: 18132065 23091673 Year: 2016 Volume: 12 Issue: 1 Pages: 22-22
Publisher: iraqi society for alternative and renewable energy sources and techniques الجمعية العراقية لمصادر وتقنيات الطاقة البديلة والمستجدة

Loading...
Loading...
Abstract

A team of scientists in France has created a metasurface on which individual plasmonic nanoantennas act as infrared “pixels,” allowing the surface to encode infrared images of surprising detail. The fabrication technique can encode multiple images on a single metasurface that can be read out by using different settings of polarization and wavelength—a characteristic that the researchers believe could make the metasurfaces useful in applications such as anti-counterfeit devices.


Article
Evaluation of Some Properties of Prepared Indomethacin Mouth Wash and Its Effect on Gingival Index Score

Authors: Mustafa Kh. Al-Nori --- Ghada A. Taqa --- Ziad H. Delemi
Journal: Al-Rafidain Dental Journal مجلة الرافدين لطب الأسنان ISSN: 18121217 Year: 2014 Volume: 14 Issue: 29 Pages: 259-265
Publisher: Mosul University جامعة الموصل

Loading...
Loading...
Abstract

Aims: to prepare Indomethacin mouth wash and study some of its properties (IR, pH, Density, Viscosity, Surface tension). Also, the effect on gingival index score were evaluated. Indomethacin mouth wash was prepared in a concentration of (0.05%) distil water from pure Indomethacin powder. Methods: The study was carried out on 40 subjects aged (20-30) years old. They were divided into four groups ten for each, three groups complaining of gingivitis. The gingival index score for all were measured before and after treatment, treatment involved mechanical treatment by scaling and polishing at dental clinic and drug treatment in which the first group received Indomethacin mouth wash, second group received Chlorhexidine mouth wash and third group received distal water as a mouth wash three times daily for three days, while the fourth group consisted of 10 volunteer subjects without gingivitis. Data were analyzed using paired t-test, ANOVA test and Duncan's Multiple analysis range test. Results: The results showed that the gingival index score levels were decreased significantly in all treatment groups between pre and post treatment at the same group. Conclusions: Indomethacin mouth wash have anti inflammatory effect that can decrease gingival index level.


Article
Design and Fabrication of Thin Film a-Si/Al2O3 Infrared Filter
تصميم وتصنيع مرشح الأشعة تحت الحمراء نوع a-Si/Al2O3

Authors: Dr. Khalid Khaleel Mohammad د. خالد خليل محمد --- Mr. Saad Gazai سعد غزاي
Journal: AL Rafdain Engineering Journal مجلة هندسة الرافدين ISSN: 18130526 Year: 2012 Volume: 20 Issue: 4 Pages: 60-68
Publisher: Mosul University جامعة الموصل

Loading...
Loading...
Abstract

ABSTRACTLong-wavelength infrared filter operated at various temperature are critical for imaging applications. In this paper anew type of infrared filter is investigated, this infrared filter uses a crystalline silicon substrate coated with multi layers of aluminum oxide (AL2O3) and amorphous silicon (a-Si) to produce the multi layers thin film infrared filter a-Si/AL2O3 operating in the range (8-14)um. Amorphous silicon is used in this paper due to its high refractive index, while AL2O3 due to its low refractive index material. The a-Si/ AL2O3 thin film structure were designed using the Thin Film Design software (TF Calc 3.5.6 version). The simulated results obtained shows that the transmittance of the a-Si/ AL2O3 infrared filter with 19 layers is about 90% for (8-12.5) µm wavelength, while it is about 95% for 47 layers for (8.25-13.25) µm wavelength. The investigated filter was fabricated using vacuum evaporation process and the results obtained were comparable with the simulated one. The fabricated a-Si/ AL2O3 filter is compared with the Ge/ZnS infrared filter and it is found that the results is comparable but the cost of the fabricated filter is small compared to the Ge/ZnS filter.Keyword: Infrared Filter, Silicon, Aluminum Oxide.

الخلاصةيعتبر مرشح الموجة تحت الحمراء والذي يعمل بدرجات حرارة مختلفة من العناصر المهمة في التطبيقات الصورية. تم في هذا البحث اقتراح نوع جديد من مرشح الموجة تحت الحمراء مكون من طبقة أساسية من مادة السيلكون المتبلور ومرسب عليها طبقات عديدة من مادة أوكسيد الألمنيوم ومادة السيلكون العشوائي التركيب (a-Si) وذلك لتكوين مرشح الموجة تحت الحمراء ضمن الحزمة (8-14) m. تم استخدام مادة السيلكون العشوائي في البحث بسبب معامل انكساره العالي بينما تمتاز مادة أوكسيد الألمنيوم بمعامل انكسار واطئ ، وتمت عملية التصميم باستخدام البرنامج (TF calc 3.5.6 version) حيث تم الحصول على مرشح مكون من 19 طبقة وذات نفاذية مقدارها 82% للطول الموجي (8-12.5) m ، بينما كانت النفاذية بحدود 90% باستخدام 47 طبقة للطول الموجي (8-13.75) m. تم تصنيع المرشح المقترح باستخدام جهاز التبخير الفراغي وكانت النتائج قريبة جداً من نماذج التمثيل بالحاسوب. كذلك تمت مقارنة النتائج مع المرشح المكون من مادة الجرمانيوم ومادة كبريتيد الخارصين وكانت النتائج متقاربة ولكن مع كلفة قليلة للمرشح المقترح مقارنة مع المرشح المصنع من مادة الجرمانيوم ومادة كبريتيد الخارصين (Ga/ZnS).


Article
Use of Infrared Light to Improve Breast Sonographic images
استعمال الأشعة تحت الحمراء لتحسين صورة السونار في فحص الثدي

Authors: Salma A. Redha سلمى علي رضا --- Issa M. Kadhim عيسى محمد كاظم
Journal: Baghdad Science Journal مجلة بغداد للعلوم ISSN: 20788665 24117986 Year: 2014 Volume: 11 Issue: 2 عدد خاص بالمؤتمر النسوي الثاني Pages: 625-634
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

It is well known that sonography is not the first choice in detecting early breast tumors. Improving the resolution of breast sonographic image is the goal of many workers to make sonography a first choice examination as it is safe and easy procedure as well as cost effective. In this study, infrared light exposure of breast prior to ultrasound examination was implemented to see its effect on resolution of sonographic image. Results showed that significant improvement was obtained in 60% of cases.

من المعروف ان استعمال السونار هو ليس الأختيار الاول في فحص الثدي للكشف المبكر عن اورام الثدي. وان تحسين درجة الوضوح في صورة الثدي بالامواج فوق الصوتية هو هدف كثير من الباحثين جعله الخيار الاول كونه فحصا امينا خاليا من التأثيرات الجانبية وطريقة سهلة بالاضافة الى انها قليلة التكاليف مقارنة بطرق التصوير الاخرى كالماموكراف والرنين المغناطيسي.في هذه الدراسة استعملت الاشعة تحت الحمراء كمصدر حراري لتعريض منطقة الثدي قبل الفحص وذلك لكي تتحسن درجة الوضوح. أظهرت النتائج حصول تحسن مهم في درجة وضوح صورة الامواج فوق الصوتية بعد التعرض للاشعة تحت الحمراء بنسبة 60% من الحالات عما قبل التعرض.


Article
Thermal Field Analysis of Oblique Machining Process with Infrared Image for AA6063-T6
تحليل المجال الحراري لعمليه التشغيل المائله

Authors: Osamah F. Abdulateef أسامه فاضل عبد اللطيف --- Lara A.Salman لاره عبد الكريم سلمان
Journal: Al-Khwarizmi Engineering Journal مجلة الخوارزمي الهندسية ISSN: 18181171 23120789 Year: 2015 Volume: 11 Issue: 1 Pages: 1-10
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

Metal cutting processes still represent the largest class of manufacturing operations. Turning is the most commonly employed material removal process. This research focuses on analysis of the thermal field of the oblique machining process. Finite element method (FEM) software DEFORM 3D V10.2 was used together with experimental work carried out using infrared image equipment, which include both hardware and software simulations. The thermal experiments are conducted with AA6063-T6, using different tool obliquity, cutting speeds and feed rates. The results show that the temperature relatively decreased when tool obliquity increases at different cutting speeds and feed rates, also it is found that the mean tool rake face temperature distribution decreases with increase of tool obliquity. The result also show that the maximum error between the predicted and measured temperatures by IR camera was between 6-27 °C.

أﻥ ﺍﻏﻠﺏ ﺍﻟﻌﻤﻠﻴﺎﺕ ﺍﻟﺘﺼﻨﻴﻌﻴﺔ ﻭﺍﻟﺘﺸﻐﻴﻠﻴﺔ ﺘﻨﺠﺯ ﺒﺎﺴﺘﺨﺩﺍﻡ ﻤﻜﺎﺌﻥ ﺍﻟﺘﺸﻐﻴل ﺍﻟﻤﺨﺘﻠﻔﺔ,ﺤﻴﺙ ﺘﻤﺭﺍﻟﻤﺸﻐﻭﻻﺕ ﺒﺴﻠﺴﻠﺔ ﻤﻥ ﺍﻟﻌﻤﻠﻴﺎﺕ ﺍﻟﺘﺸﻐﻴﻠﻴﻪ ﺍﻟﻤﺨﺘﻠﻔﺔ ﺍﺒﺘﺩﺃ ﻤﻥ ﺍﻟﻤﺎﺩﺓ ﺍﻻﻭﻟﻴﻪ ﻭﺼﻭﻻ ﺍﻟﻰ ﺍﻟﻤﻨﺘﺞ ﺍﻟﻨﻬﺎﺌﻲ، ﻭﺘﻌﺘﺒﺭ الخراطه الاكثر استخداما في عمليات قطع المعادن, هذا البحث يركز على تحليل التوزيع الحراري خلال عمليات القطع المائل بأستخدام طريقه العناصر المحدده (FEM) وتطبيقها في برنامج DEFORM 3D V10.2 . تم استخدام ماده الالمنيوم AA6063-T6 بظروف تشغيل متعدده (سرع قطع, تغذيه, ميلان الاداه) .اظهرت نتائج القياسات الحراريه بالاشعه تحت الحمراء ذات الدقه العاليه بعد مقارنتها مع نتائج طريقه العناصر المحدده(FEM) انخفاض متوسط درجات الحراره عند وجه جرف الاداه عند زياده ميل الاداه عند سرعه قطع وتغذيه مختلفه,وكذلك اظهرت النتائج اعلى نسبه خطاء بين درجه الحراره المتوقعه والمقاسه بالكاميرا الحراريه يتراوح بين6-27 °C .

Keywords

Infrared --- Deform-3D --- tool obliquity --- turning.


Article
Numerical Analysis of the Effect of Scanning Speed on the Temperature Field Distribution for Laser Heat Treatment Applications

Author: Furat I. Hussein Al-Najjar
Journal: AL-NAHRAIN JOURNAL FOR ENGINEERING SCIENCES مجلة النهرين للعلوم الهندسية ISSN: 25219154 / eISSN 25219162 Year: 2018 Volume: 21 Issue: 2 Pages: 213-222
Publisher: Al-Nahrain University جامعة النهرين

Loading...
Loading...
Abstract

One of the unique properties of laser heating applications is its powerful ability for precise pouring of energy on the needed regions in heat treatment applications. The rapid rise in temperature at the irradiated region produces a high temperature gradient, which contributes in phase metallurgical changes, inside the volume of the irradiated material. This article presents a comprehensive numerical work for a model based on experimentally laser heated AISI 1110 steel samples. The numerical investigation is based on the finite element method (FEM) taking in consideration the temperature dependent material properties to predict the temperature distribution within the irradiated material volume. The finite element analysis (FEA) was carried out using the APDL scripting language (ANSYS Parametric Design Language) that is provided by the commercial code ANSYS. Infrared (IR) thermography technique was used to explore the workpiece surface and to validate the obtained results. The work takes into account the effect of different speeds of the laser beam and pulses overlap on the temperature pattern of the material surface and depth.

Listing 1 - 10 of 46 << page
of 5
>>
Sort by
Narrow your search

Resource type

article (46)


Language

English (33)

Arabic (7)

Arabic and English (4)


Year
From To Submit

2019 (1)

2018 (13)

2017 (7)

2016 (2)

2015 (6)

More...