research centers


Search results: Found 9

Listing 1 - 9 of 9
Sort by

Article
Calculation the mass attenuation coefficient of beta-particles through Polyvinyl chloride
حساب معامل التوهين الكتلي لجسيمات بيتا خلال بولي كلوريد الفاينيل

Authors: Harith I. Jaafer حارث ابراهيم جعفر --- Ban M. Alshabander بان مازن مزاحم الشابندر
Journal: Iraqi Journal of Physics المجلة العراقية للفيزياء ISSN: 20704003 Year: 2010 Volume: 8 Issue: 12 Pages: 50-53
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

The mass attenuation coefficient for beta particles through pure Polyvinyl chloride (PVC) and flax fibers- reinforced PVC composite were investigated as a function of the absorber thickness and the absorber to source distance. The beta particles mass attenuation coefficients were obtained using a NaI(Tl) energy selective scintillation counter with 90Sr/ 90Y beta source having an energy range from (0.546-2.275) MeV. Pure PVC polymer samples were prepared by compacting the PVC powder in a mould at high pressure (10bar) and temperature about 140°C for 30 minutes. A hot press system was used for this process. The experimentally obtained values of mass attenuation coefficients for 90Sr and 90Y were found to be 7.72 cm2.g-1and 0.842 cm2.g-1 respectively, and the measured mass attenuation coefficients values decrease with increase of the absorber to source distance .

تمت دراسه معامل التوهين الكتلي لجسيمات بيتا خلال عينات من مادة بولي كلوريد الفاينيل (PVC) ومتراكب الياف الكتان المدعمة بــ (PVC) كدالة لسمك المادة الماصة وللمسافة بين المادة الماصة والمصدر المشع. تم قياس معامل التوهين الكتلي لجسيمات بيتا باستخدام منظومة الكاشف الوميضي NaI(Tl) مع مصدر أشعة بيتا 90Sr/90Y بمدى طاقة تتراوح بين (0.546-2.75) ميكا الكترون فولت. حضرت عينات (PVC) النقي عن طريق كبس مسحوق الـ (PVC) في قالب معدني تحت ضغط عالي مقداره 10 بار وبدرجة حرارة 140 درجة مئوية ولمدة 30 دقيقة ولقد استخدمت منظومه الكبس الحراري لهذا الغرض. وجد ان القيم العملية المستحصلة لمعامل التوهـين الكتلي لـ 90Sr و 90Y هي 7.72 cm-2.g-1 و 0.842 cm-2.g-1 على التوالي. وان قيم معاملات التوهين الكتلي تتناقص مع زيادة المسافة بين المادة الماصة والمصدر.


Article
Variation of gamma ray attenuation parameters for Poly vinyl alcohol reinforced by lead acetate
تغير معاملات توهين أشعة كاما لبولي فاينيل الكحول المدعم بخلات الرصاص

Author: Abbas J. Al-Saadi
Journal: journal of kerbala university مجلة جامعة كربلاء ISSN: 18130410 Year: 2014 Volume: 12 Issue: 3 Pages: 35-44
Publisher: Kerbala University جامعة كربلاء

Loading...
Loading...
Abstract

Design types of shielding polymers to protect patients and personnel from the effect of scattered radiation during radiotherapy. Some shielding factors were calculated such as mass attenuation coefficient (µm), half value layer (HVL), effected atomic number (Zeff ) and heaviness for polyvinyl alcohol (PVA) as matrix material mixed with various levels of lead acetate (10 - 50 wt. % ) as reinforced materials at photon interactions in the wide gamma ray energy range of 0.001-100 MeV using XCOM program and measured at 0.662 MeV by usage a 137Cs radioactive source. The experimentally obtained values were generally in good agreement with the theoretical ones. The results revealed that the shielding properties of poly vinyl alcohol increased with the addition of lead acetate. Gamma ray shielding properties of our polymer samples have been compared with standard ordinary concrete. It was found that 20wt.% of lead acetate (CH3COO)2Pb is the minimum percent mixed with PVA improves the gamma ray shielding properties best than standard ordinary concrete (NIST).

تم تصميم مواد بوليمرية لحماية المرضى والعاملين في مجال الأشعاع المنتشر اثناء التعرض. حسبت بعض عوامل التوهين مثل معامل التوهين الكتلي, سمك النصف, العدد الذري المؤثر لبولي فاينيل الكحول (كمادة اساس ) مدعمة بتراكيز مختلفة من خلات الرصاص بنسب وزنية (10 - 50 wt. %) عند مدى واسع من طاقة أشعة كاما0.001 -100 MeV باستخدام البرنامج العالمي XCOM . كذلك تم حساب معاملات التوهين عمليا لفوتونات ذات الطاقة 0.662MeV باستخدام المصدر المشع 137Cs . أظهرت النتائج ان توهين الفوتونات يزداد بزيادة تركيز خلات الرصاص في النموذج. القيم العملية لمعاملات التوهين كانت عموما موافقة للقيم النظرية. كذلك قورنت معاملات التوهين للنماذج مع نموذج قياسي للكونكريت العادي. وجد ان خلط 20wt.% من خلات الرصاص مع بولي فاينيل الكحول تمثل الحد الادنى لتحسين معاملات التوهين ليكون افضل من الكونكريت العادي (القياسي).


Article
Determination the density of cometary nucleus material using gamma ray attenuation
تحديد كثافة مواد نواة المذنب بأستخدام توهين أشعة كاما

Authors: Aseel A. Temur اسيل عبد تمر --- Alaa B. Kadhim علاء باقر كاظم
Journal: Iraqi Journal of Science المجلة العراقية للعلوم ISSN: 00672904/23121637 Year: 2016 Volume: 57 Issue: 2C Pages: 1572-1583
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

In this work, the technique of attenuation of gamma ray to calculate the density of comet nucleus materials (C/2009 P1 (GARRADD) at different range of energy (0.2- 0.9 MeV). also, the single scattering model for gamma rays has been assumed that photons reaching the detector with scattered only once in the material. The program has been designed and written in FORTRAN language (77 – 90) to calculate the density for molecules using Monte Carlo method was used to simulate the scattering and absorption of photons in semi- infinite material. Gamma ray interacts with the matter by three mainly interactions: Photoelectric effect, Compton scattering and Pair production (electron and positron). On the 137Cs source energy (662 keV), Compton scattering is the dominant interaction. at energies below about 150 keV the Photoelectric effect is significant , While Pair production occurs at energies above twice the electron rest mass energy (1.022 MeV). Both these processes have mass attenuation coefficients that are heavily dependent on elemental composition, which is why only those source energies within the "Compton window" are useful for densitometry. The calculation of our results of the density were compared with the real density and the comparison is very good.

في هذا البحث تم استخدام تقنية جديدة باستخدام توهين اشعة كاما في حساب الكثافة لمواد المذنب عند مختلف الطاقات (0.2 - 0.9 MeV). ايضآ، استخدم نموذج الاستطارة المنفردة لأشعة كاما المنعكسة التي تفترض بأن الفوتونات التي تصل للكاشف تستطار مرة واحدة في المادة. استخدمت طريقة مونتي كارلو لمحاكاة استطارة وامتصاص الفوتونات في المواد الشبه لا نهائية حيث تم كتابة برنامج بلغة الفورتران ((77-90 لحساب كثافة الجزيئات . أشعة كاما تتفاعل مع المادة بواسطة ثلاث تفاعلات رئيسية: ظاهرة التأثير الكهروضوئي , استطارة كومبتن و انتاج الزوج (الالكترون والبوزترون). مصدر السيزيوم عند طاقة 662 keV)) , تحدث استطارة كومبتن , عند طاقة اقل من 150 keVتحدث ظاهرة التأثير الكهروضوئي , بينما انتاج الزوج تحدث عند طاقة تفوق الكتلة السكونية مرتان ((1.022 MeV كلا الظاهرتين معامل التوهين الكتلي يعتمد على تركيب العناصر, لذلك فأن ظاهرة كومبتن مفيدة للقياس. نتائج الكثافة المحسوبة نظريآ مقارنة بالكثافة الحقيقية جيدة جدا.


Article
USE OF GAMMA–GAMMA COINCIDENCE TECHNIQUE IN INVESTIGATING GAMMA – RAYS ATTENUATION AT DIFFERENT ENERGIES
استخدام تقنية تطابق كاما – كاما لدراسة توهين اشعة كاما بطاقات مختلفة

Loading...
Loading...
Abstract

A gamma–gamma fast –slow coincidence spectrometer composed of two 3"×3"NaI(Tl) detectors and peripheral electronics is used in investigating some effects on the photo peak after the penetration of gamma –rays from lead. Coincidence measurements are carried out using Na-22 source with selecting the 511 keV gate. Linear and mass attenuation (in cm²/g) coefficients measurements are made using lead sheets with dimensions 10×10 cm. Mass attenuation coefficient was measured for coincidence spectrum at 511 keV and found to be 0.114 and 0.140 for direct spectrum. Also coincidence and direct spectra measurements were carried out using Co-60 source with 1332 and 1173 keV gates. Mass attenuation coefficient at 1173 keV was 0.0460 for coincidence spectrum and 0.0522 for direct spectrum. At 1332 keV the same coefficient was0.0432 for coincidence spectrum and 0.0452 for direct spectrum. Mass attenuation coefficients values from coincidence measurement are lower than those in direct measurement at same energies.

استخدام مطياف كاما – كاما التطابقي السريع – البطئ المكون من كاشفين وميضيينNaI(Tl) كل بحجم3"×3" والوحدات الالكترونية الملحقة لدراسة بعض التأثرات التي تحدث للقمة الضوئية بعد نفوذ اشعة كاما من مادة الرصاص. أجريت القياسات التطابقية باستخدام مصدر Na -22 وباختيار البوابة 511 keV. أجريت قياسات معامل التوهين الخطي والكتلي (بوحدةcm2/g) باستخدام الواح رصاص وبأبعاد10×10 cm. قيس معامل التوهين الكتلي بالطيف التطابقي عند الطاقة511 keVفوجد انه يساوي 0.114 وبالطيف المباشر 0.140. أجريت القياسات التطابقية والمباشرة أيضا باستخدام مصدرCo-60 وللبوابتين(1173, 1332) keV فكان معامل التوهين الكتلي عند الطاقة1173 keV مساويا لـ0.0460 للقياس التطابقي و 0.0522 للقياس المباشر. اما عند الطاقة 1332 keV فكان 0.0432 للقياس التطابقي و 0.0452 للقياس المباشر. ان قيم معاملات التوهين بالقياس التطابقي هي اقل من تلك المسجلة بالقياس المباشر للطاقة نفسها


Article
Study the effect of thickness on attenuations coefficient of polystyrene -bentonite Composite
دراسة أثر السمك على معاملات التوهين لمتراكب بولي ستايرين - بنتونايت

Author: Wasan K. Hasan وسن كامل حسن
Journal: Journal of Kufa - physics مجلة الكوفة للفيزياء ISSN: 20775830 Year: 2015 Volume: 7 Issue: 1 Arabic Pages: 8-17
Publisher: University of Kufa جامعة الكوفة

Loading...
Loading...
Abstract

Achievement of studying effect the addition ratio of powder from clays Iraqi bentonite (D<75um) treated with temperature (100 ºC) and treated with PVA as filler on polystyrene to dissolved in toluene with the state ratios and temperature degrees (70-80 ºC).The attenuation measurements of X-Ray for the voltage range (20,25,30)KV for the composite polystyrene-bentonite were done by using X-Ray unit with two X-Ray tubes (Cu tube , Eu tube) and G-M counter.The linear attenuation coefficient (µL) were concluded for the voltage range mentioned above through the linear equations of the yield of graphic representation operation between the logarithmic absorption and the sample thickness X(cm) , the mass attenuation coefficient( µm) were also concluded through the graphic relation between the logarithmic absorption and the equivalence thickness of the samples Xm (gm/cm2) such that the slope of the graphic relation represents the attenuation coefficient either linear or mass.The linear relation between the logarithmic absorption of X-Ray with the thickness and equivalent thickness sample were concluded .Inverse relation between the linear and mass attenuation coefficient with X-Ray voltage were also concluded of composite

تمت دراسة اثر اضافة مسحوق من اطيان البنتونايت العراقي (D<75µm) المحمص بدرجة (100 ºC) والمعالج بمادة PVA كمادة مالئة للبولي ستايرين المذاب بالتولوين بنسب معينة وبدرجة حرارة (70-80 ºC) ثم اجريت قياسات التوهين للاشعة السينية لمديات الفولتية (20,25,30)KV لمتراكب البولي ستايرين- بنتونايت وباستخدام وحدة الاشعة السينية مع انبوبتي توليد الاشعة السينية (النحاس واليوربيوم ) ومنظومة كاشف كايكر مولر .تم الحصول على معامل التوهين الخطي (µL)لمديات الفولتية المذكورة انفا من خلال المعادلات الخطية لناتج عملية التمثيل البياني بين لوغاريتم الامتصاصية وسمك النموذج X(cm) وايضا الحصول على معاملات التوهين الكتلي(µm) لنفس مديات الفولتية من خلال العلاقة البيانية بين لوغاريتم الامتصاصية والسمك المكافيء للنماذج Xm(gm/cm2) حيث ان ميل العلاقة البيانية يمثل معامل التوهين سواء كان خطيا ام كتليا .تم تحقيق العلاقة الطردية بين لوغاريتم الامتصاصية للاشعة السينية مع السمك والسمك المكافيء والعلاقة العكسية بين معاملات التوهين الخطية والكتلية للمتراكب مع فولتية توليد الاشعة السينية .


Article
Calculation of Atomic Cross section &Electron Density for (Tissue and Bone ) using Monte Carlo program
حساب مساحة المقطع العرضي الذري والكثافة الكترونية لـــ (الانسجة والعظام) باستخدام برنامج مونت كارلو

Author: Abdulhadi.M.Ghelab
Journal: journal of kerbala university مجلة جامعة كربلاء ISSN: 18130410 Year: 2016 Volume: 14 Issue: 1 Pages: 38-44
Publisher: Kerbala University جامعة كربلاء

Loading...
Loading...
Abstract

In the present work , calculated mass attenuation coefficients ,atomic cross section and electron density for these tissue and bone were theoretically calculated using monte carlo program within a range of energies of x-rays (16.5-17.5-21.5-24.5)keV .The attenuation coefficient of substances ,at any energy of x-ray photon ,is known to depends on the electron density and effective atomic number of the material .which makes it very sensitive to the index "x" .Several different values laying between) 0.5 - 2.5( step 0.5 have been suggested for the exponent "x".The results were compared with XCOM program .These theoretical values are found to be in agreement with the calculated from XCOM value .

في هذا البحث,حسبت معاملات التوهين الكتلية ـ المساحة المقطع العضي الذري وكذلك الكثافة الالكترونية للانسجة والعظام باستخدام برنـامج مونت كارلو ولمدى الطاقــــــات الاشعة السينية (16.5-17.5-21.5-24.5)keV.وتم فرض الاسماك المختلفة لمواد المذكوره اعلاه ,اظهرت النتائج ان المعامل التوهين يقل بزيادة الطاقة الاشعة السينية .وقورنت البيانات البحث الحالي مع برنامج (XCOM) (Version 3.1) وكانت هناك توافق جيد في الحسابات


Article
COMPARISON OF GAMMA–RAYS ATTENUATION MEASURED BY DIRECT AND COINCIDENCE SPECTRA
مقارنة توهين اشعة كاما المقاسة بالطيف المباشر والطيف التطابقي

Authors: Mahmoud A. Elawi محمود احمد عليوي --- KhalafI. Khalil خلف ابراهيم خليل --- , Du´aa K. Hamad دعاء خلف حمد
Journal: Tikrit Journal of Pure Science مجلة تكريت للعلوم الصرفة ISSN: 18131662 Year: 2017 Volume: 22 Issue: 12 Pages: 98-108
Publisher: Tikrit University جامعة تكريت

Loading...
Loading...
Abstract

Measurements of gamma –rays attenuation in lead and iron sheets were carried out using direct spectrum and gamma- gamma fast slow coincidence spectrometer composed of two 3"×3"NaI(Tl) detectors and Na-22 source. Measurements of mass attenuation coefficient at 511keV were carried out and its values (in cm²/g units) for lead from direct spectrum for the cases of without and with using a collimator (1cm diameter and 5 cm length) were 0.12029 and 0.13591and from coincidence spectrum were 0.10721 and 0.10602 respectively. For iron sheets the mass attenuation coefficient values from direct spectrum for the cases of without and with using a collimator were 0.0780 and 0.0766 andfrom coincidence spectrum were 0.0593 and 0.0616 respectively. The present results registered by direct measurement are little lower than the standard values due to making only photoelectric absorption needed for comparison with coincidence results where the latter showed lower values. The build-up factor were also measured as function of thickness using lead and iron sheets and found fluctuating around unity for lead and iron coincidence spectra and iron direct spectrum, whereas its increases gradually for lead direct spectrum for the measured thickness range. The coincidence spectrometer greatly reduces scatteringevents in the measured material, and thus its results somewhat resemble that of direct measurements with using the collimator.

اجريت قياسات توهين اشعة كاما في الواح من الرصاص والحديد بالقياس المباشر وباستخدام مطياف كاما - كاما التطابقي السريع – البطيء المكون من كاشفي 3"×3"NaI(Tl) ومصدر Na-22. اجريت قياسات معامل التوهين الكتلي عند الطاقة 511 keVووجد ان قيمه (بوحدة cm²/g) للرصاص ومن الطيف المباشر ولحالتي بدون مسدد وباستخدام مسدد (قطره 1cm وطوله 5cm) هي 0.12029 و0.13591 ومن الطيف التطابقي هي 0.10721 و 0.10602 على التوالي. ولألواح الحديد كان معامل التوهين الكتلي من الطيف المباشر ولحالتي بدون مسدد وباستخدام مسدد هو 0.0780 و 0.0766 ومن الطيف التطابقي هو 0.0593و0.0616 على التوالي. ىان النتائج المسجلة بالقياس المباشر للدراسة الحالية هي اقل قليلاً من القيم القياسية المعروفة عالمياً لاعتماد قياسنا الامتصاص الكهروضوئي فقط وذلك للمقارنة مع النتائج التطابقية التي أظهرت قيماً أقل. وقيس عامل التراكم دالة للسمك باستخدام الواح الرصاص والحديد ووجد انه يتأرجح تقريباً حول قيمة الواحد لكل من الطيف التطابقي للرصاص والحديد والطيف المباشر للحديد، في حين تزداد قيمته تدريجياً للطيف المباشر للرصاص وذلك لمدى السمك المقاس. ان المطياف التطابقي يختزل كثيراً حوادث الأستطارة بالمادة المقاسة لذلك فنتائج قياسه تشابه نوعا ما القياس المباشر باستخدام المسدد


Article
Gamma Ray Attenuation Coefficients for Lead Oxide and Iron Oxide Reinforced In Silicate Glasses as Radiation Shielding Windows
معاملات توهين اشعة كاما في الزجاج المدعم بأوكسيد الرصاص و أوكسيد الحديد كنوافذ للتدريع الأشعاعي

Loading...
Loading...
Abstract

In this work, the mass attenuation coefficient, effective atomic number and half value layer parameters were calculated for silicate (SiO2) mixed with various levels of lead oxide and iron oxide as reinforced materials. SiO2 was used with different concentrations of PbO and Fe2O3 (25, 50 and 75 weight %). The glass system was prepared by the melt-quenching method. The attenuation parameters were calculated at photon energies varying from 1keV to 100MeV using the XCOM program (version 3.1). In addition, the mass attenuation coefficient and half value layer parameters for selected glass samples were experimentally determined at photon energies 0.662 and 1.28 MeV emitted from radioactive sources 137Cs and 22Na respectively in a collimated narrow beam geometry set-up using 2"x2" NaI (Tl)scintillation detector. These values are found to be in agreement with the values computed theoretically. Moreover, these results were also compared with those for the commercial window glass. The effective atomic number ( Zeff ) and half value layer (HVL) results indicate that pbO+SiO2 was better gamma ray attenuation than Fe2O3+SiO2 and commercial window glass. This indicates that PbO+SiO2 glasses can be used as gamma ray shielding in replace of both of them in this energy range.

تم في هذا البحث حساب معامل التوهين الكتلي والعدد الذري المؤثر و سمك النصف لنماذج زجاجية مكونة من اوكسيد السليكون مادة اساس مدعمة باوكسيد الحديد الثلاثي, واوكسيد الرصاص بتراكيز وزنية مختلفة % wt.(25, 50, 75 ) عند مدى واسع من طاقة الفوتون تراوحت من 1keVالى100MeV باستخدام البرنامج العالمي (XCOM) . كذلك حسب معامل التوهين الكتلي وسمك النصف للنماذج عمليا باستخدام حزمة ضيقة من اشعة كاما عند الطاقات0.662 MeV و 1.28MeVالمنبعثة من النظائر المشعة 137Cs و 22Naعلى التوالي. استعمللهذا الغرض الكاشف الوميضي 2"x2" NaI(Tl) فكانت هذه القيم موافقة للقيم النظرية. فضلا عن ذلك قورنت النتائج أيضا مع زجاج النوافذ التجاري. تشير نتائج العدد الذري المؤثر وسمك النصف أن زجاج PbO +SiO2 أفضل توهينا لأشعة كاما من الزجاج Fe2O3+SiO2 , وزجاج النوافذ التجاري وهذا يبين استعمال الزجاج PbO +SiO2 للحماية من أشعة كاما بدل الزجاج Fe2O3+SiO2 وزجاج النوافذ التجاري في هذا المدى من الطاقة.


Article
Calculation the Effective atomic number , electron density, Half value layer and mean free path of Iron, Copper and Silver
حساب العدد الذري الموثر والكثافة الالكترونیة وسمك النصف ومعدل المسار الحر للنحاس و الحدید والفضة

Loading...
Loading...
Abstract

Effective atomic number (Zeff) ,electron densities (Nel) , half value layer(HVL) and mean free path (mfp) has been determined with the help of semi-empirical relations for Iron, Copper and Silver at energy range 0.36 to 1.33MeV .The study proved the coincidence of the experimental and theoretical values of effective atomic number while the electron densities and mean free path are found nearly remain constant as a function of energy.

في هذا البحث تم حساب العدد الذري الموثر(Zeff) ,الكثافة الالكترونية (Nel), ,سمك النصفHVL , ومعدل المسار الحر(mfp) للنحاس و الحديد والفضة باستخدام عدد من المعادلات شبه التجريبية ولمدى الطاقات 0.36MeV-1.33 MeV –لقد بينت الدراسة تطابق القيم العملية والنظرية للعدد الذري الموثر وان الكثافة الالكترونية وسمك النصف ومعدل المسار الحر تقريبيا تبقى ثابتة كدالة لطاقة الساقطة .

Listing 1 - 9 of 9
Sort by
Narrow your search

Resource type

article (9)


Language

English (5)

Arabic (3)

Arabic and English (1)


Year
From To Submit

2017 (2)

2016 (2)

2015 (1)

2014 (3)

2010 (1)