research centers


Search results: Found 53

Listing 1 - 10 of 53 << page
of 6
>>
Sort by

Article
ESTIMATION OF MASS TRANSFER COEFFICIENTS IN A PACKED DISTILLATION COLUMN USING BATCH MODE

Authors: Mohammed D. Selman --- Adil A. Al-Hemiri عادل احمد عوض
Journal: Iraqi Journal of Chemical and Petroleum Engineering المجلة العراقية للهندسة الكيمياوية وهندسة النفط ISSN: 19974884/E26180707 Year: 2011 Volume: 12 Issue: 1 Pages: 13-21
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

This research adopts the estimation of mass transfer coefficient in batch packed bed distillation column as function of physical properties, liquid to vapour molar rates ratio (L / V), relative volatility (α), ratio of vapour and liquid diffusivities (DV / DL), ratio of vapour and liquid densities (ρV / ρL), ratio of vapour and liquid viscosities (µV/ µL). The experiments are done using binary systems, (Ethanol Water), (Methanol Water), (Methanol Ethanol), (Benzene Hexane), (Benzene Toluene). Statistical program (multiple regression analysis) is used for estimating the overall mass transfer coefficient of vapour and liquid phases (KOV and KOL) in a correlation which represented the data fairly well.KOV = 3.3 * 10-10 α-0.7 (DV / DL) 0.65 (L / V) 3.5 (ρV / ρL) 1.25 (μV / μL) -5.0KOL = 2.8 * 10-6 α-0.95 (DV / DL) 0.03 (L / V) 1.15 (ρV / ρL )0.077 (μV / μL) -0.9 In this research a method where the resistances to mass transfer in both phases are accounted for separately through the use of HTU-NTU model for each phase Z=HTUOV.NTUOV and Z=HTUOL.NTUOL Results show that both overall vapour and liquid mass transfer coefficient are increased with liquid to vapour molar rates ratio, vapour to liquid diffusivities ratio and vapor to liquid densities ratio, but decreased with increasing the relative volatility and vapour to liquid viscosities ratio.


Article
The Influence of Reynolds Number and Temperature on the Mass Transfer Coefficient of the Corroding Pipe

Authors: Basim O. Hasan --- Q.J.M. Slaiman
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2005 Volume: 11 Issue: 4 Pages: 741-750
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

Corrosion of carbon steel pipe in aerated O.l N NaCl solution under isothermal turbulent flow conditions (Reynolds number= 15000-113000 and temperature of 30-60°C) is investigated by weight loss method. The effect of Reynolds number and temperature on corrosion rates is experimentally studied and discussed. Corrosion mechanism is analyzed as a mass transfer operation and the corrosion rate is expressed in terms of mass transfer dimensionless groups (Sh and St) and in terms of usual corrosion units. The results of corrosion rates are compared with many proposed models particularly those based on the concept of analogy among mass, heat, and momentum transport by determining experimental friction factor. The capability of these models to express corrosion rates over the investigated range of Re and temperature is examined and discussed. Many of these correlations are adopted to estimate corrosion rates for the considered system. It is found that Reynolds number increases the corrosion rate depending on temperature. Temperature increases the corrosion rate for high and moderate values of Reynolds number. At low Reynolds number the effect of temperature depends on oxygen solubility, oxygen molecular diffusivity, and Reynolds number (or eddy diffusion). Generally, Von Karman and Prandtl- Taylor analogies (based on the experimental friction factor) show good agreement with experimental mass transfer results while Chilton-Colburn analogy exhibits reasonable agreement at low Reynolds number and some overestimation at high Reynolds number.

تم إجراء إختبارات التآكل على إنبوب من الفولاذ الكا ربوني في محلول كلوريد الصوديوم (0.1 عياري) الحاوي على أوكسجين الجو الذائب تحت ظروف الجريان المضطرب بسرع ودرجات حرارة مختلفة (عدد رينولد 15000 الى 113000 ودرجة حرارة من 30oC إلى 65oC) بإستخدام طريقة فقدان الوزن. تمت دراسة مختبرية ومناقشة تأثير عدد رينولد (أو السرعة) ودرجة الحرارة على معدل التآكل وتأثير. تم تحليل عملية التآكل كعملية إنتقال كتلة ووضعت علاقات تجريبية وضعية لحساب معدل التآكل تحت ظروف مختلفة. وقد تم مقارنة النتائج العمليه مع عدة علاقات موضوعة للتعبير عن انتقال الكتله بين الجدار والمائع وخاصة العلاقات المبنية عن التشابه في ميكانيكية الانتقال بين الكتلة والحرارة والزخم لمعرفة امكانية حساب معدل التآكل باستخدام هذه العلاقات. وقد تم اعتماد بعض هذه ألعلاقات للتعبير عن معدل التآكل للنظام المذكور. دلت النتائج على ان زيادة عدد رينولد تؤدي الى زيادة معدل التآكل لكل درجات الحرارة وكذلك تاثير عدد رينولد على معدل التأكل يتغير بتغير درجة الحرارة والزمن. زيادة درجة الحرارة تؤدي الى نى يادة معدل التأكك لقيم عدد رينولد المتوسطة والعالية أما عند قيم عدد رينولد الواطئة فان تاثير درجة الحرارة على معدل التآكل يعتمد على قيمة عدد رينولد. أبدت علاقات (Prandtl-Taylor) و (Von Karman) توافقاً جيدا مع النتائج العملية لكل قيم عدد رينولد. كذلك أبدت علاقة (Chilto1-Colburn) توافقا مع النتائج العملية عند قيم عدد رينولد المنخفضة وأعطت نتائج عالية نسبيا عند قيم عدد رينولد العالية.


Article
Determination of Volumetric Mass Transfer Coefficient in Fixed Bed Adsorption

Authors: Farah Y. Al-Kaisy --- Adi A. Al-Hemiri عادل احمد عوض
Journal: Iraqi Journal of Chemical and Petroleum Engineering المجلة العراقية للهندسة الكيمياوية وهندسة النفط ISSN: 19974884/E26180707 Year: 2007 Volume: 8 Issue: 2 Pages: 23-27
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

This work was conducted to determine the volumetric mass transfrr coefficient (Ky.a) injixed bed adsorption using hexane-benrene mixture by adsorption onto a fixed bed of white silica gel.Benzene concentration was measured by gas chromatography. The effect of fred flow rate and initial concentration of benzene in hexane-benzene mixture on the volumetric mass transfer coefficient and on the adsorption capacity of silica gel was investigated.In general, the volumetric mass transfrr coefficient increases with increasing hexane flow rate, and with increasing initial concentration of beniene in the mixture. The ultimate value of (Ky. a) was at 53 mI/ of hexane flow rate with benzene initial concentration of (653 wt. %,), and it was (99.4 kg/m3.s).The adsorptive capacity of silica gel increases with decreasing hexane flow rate, as with increasing initial concentration of benzene in the mixture. The best adsorptive capacity of the imported silica gel (100 g of imported silica gel yielded 120 ml of benzene-free effluent) was achieved with the grade (1.18-5 mm) in size at a hexane flow rate 15 m


Article
Mass-Transfer Characteristics of Air- Suction Type Fermentors
خواص انتقال المادة في المخمرات ذات الخلاطات الساحبة للهواء

Author: Alaa K. M. علاء كريم محمد
Journal: Al-Khwarizmi Engineering Journal مجلة الخوارزمي الهندسية ISSN: 18181171 23120789 Year: 2008 Volume: 4 Issue: 3 Pages: 66-73
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

Liquid-side mass-transfer coefficients (KLa) were measured in air-suction type fermentors using physical absorption of oxygen. A fermentor of 0. 5 m i.d. was used with a working capacity of 60 liters of liquid. Tap water was used as the liquid phase, and air was used as the gas phase. The bioreactor mixing system consists of shrouded-disk/curved-blade turbine with six evacuated bending blades. The effect of liquid submergence (S) was investigated. Further, the effects of the ratio of the impeller diameter (D) to the tank diameter (T), and the clearance of the impeller from the tank bottom(C) were also studied. The agitation speed (N) was varied in the range of 50-800 rpm. It was found that the value of KLa increased as the impeller diameter increased, while it was decreased continuously with increasing the clearance. The effect of impeller submergence on the value of mass transfer coefficient (KLa) is not much pronounced.Suitable correlation was developed for estimating mass transfer coefficient (KLa) in this type of bioreactors.

تم حساب معامل انتقال المادة (KLa) لذوبان الاوكسجين في وسط سائل في نوع من المخمرات ذات الريش الساحبة للهواء (Suction -Air impeller). استخدم في هذا البحث مخمر اسطواني ذات قطر (0.5 م) وارتفاع (0.7 م) وسعة حجمية (60 لتر) سائل. استخدم ماء الحنفية كطور سائل، والهواء كطور غاز. الخـلاط المستـخدم من نـوع الريــش المنحـنية المجـوفة الساحبة للهواء(Shrouded- disk/curved-blade turbine with six evacuated bending blades) استخدمت في هذه الدراسة المتغيرات الاتية: سرعة دوران الخلاط(N) ، قطر الخلاط المستخدم(D)، عمق الخلاط عن مستوى السطح العلوي لوسط السائل (S)، وارتفاع الخلاط عن قعر المخمر(C). وجد ان قيمة ( KLa) تزداد بازدياد قطر الخلاط، بينما تقل قيمته باستمرار زيادة ارتفاع الخلاط عن قعر المخمر(C).كذلك وجد عدم تاثير عمق الخلاط عن مستوى السطح العلوي لوسط السائل (S) على قيمة (KLa). تم ربط هذه المتغيرات مع معامل انتقال المادة (KLa) وفق معادلة تجريبية ذات مجاميع عديمة الوحدات (Dimensionless Groups):


Article
Experimental and Numeriacal Study of Moisture Moviment Inside an Air Conditioned Space
دراسةعملية ونظرية عن حركة بخار الماء داخل حيز مكيف

Authors: Wahid S. Mohammad --- Omar M. Mohamme
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2012 Volume: 30 Issue: 3 Pages: 398-415
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

This research is concerned with a computational study to simulate a turbulent three–dimensional buoyancy recirculation flow in an air-conditioned space. The studyincludes the simulation of heat and moisture generated from an internal source inside thespace. An experimental facility to study temperature and moisture distribution in an airconditionedspace has also been designed, constructed and tested in a laboratory scale. Anumerical procedure was carried out to solve the elliptic partial differential equations thatgovern the flow, heat and mass transfer in a finite –volume form. The finite -volumeapproach was applied to solve these equations using the upwind –differencing scheme.The SIMPLE iterative procedure [1] for solving the algebraic equations is employed inthe present study. The proposed method is the line by line technique uses the Tri-Diagonal Matrix Algorithm (TDMA) as its basic unit. A modified version of a threedimensionalelliptic computer code was used to simulate heat and moisture transfergenerated from the internal source inside the space. A study of the flow, heat and masstransfer in air-conditioned space are used as test cases to justify the performance of thecomputational procedure. The temperature and moisture distribution were compared withpredictions of previous researchers. The data from the experimental model was also usedto verify the computational procedure predictions.

یھتم ھذا البحث بالدراسة الحاسوبیة لمحاكاة الجریانات الدورانیة المضطربة والطفوی ة الثلاثی ة الابع ادفي حیز مكیف. تتضمن الدراسة محاكاة الحرارة والرطوبة المتول دة م ن مص در داخل ي داخ ل الحی ز . لق د ت مدراسة توزیع الحرارة والرطوبة في حیز مكیف بش كل تجریب ي م ن خ لال تص میم وانش اء واختب ار لنم وذجداخ ل مختب ر . لق د ابت دأ العم ل الع ددي بح ل المع ادلات التفاض لیة الجزئی ة الاھلیلیجی ة المتمثل ة بحف ظ الكتل ة،ت م .(Finite –volume) ال زخم، الطاق ة، الطاق ة المض طربة ومع دل ض یاعھا باس تخام الحج وم المح ددةلقد تم .(Upwind differencing scheme) تطبی ق الحج وم المح ددة لح ل ھ ذه المع ادلات باس تخدامThree –dimensional elliptic ) استخدام نسخة مطورة من برنامج حاسوبي اهليلجي ثلاثي الابعادلحساب الحرارة والرطوبة المنتقلة المتولدة من مصدر داخلي داخل حيز .لقد تم (computer codeدراسة الجريان وانتقال الحرارة والرطوبة في حيز مكيف كحالات اختبارية لتقييم اداء البرنامجالحاسوبي الحالي. ان توزيع الحرارة والرطوبة قد قورنت مع النتائج النظرية لباحثين سابقين . لقداستخدمت النتائج المستحصلة من العمل التجريبي لغرض تقييم اداء البرنامج.


Article
HYDRODYNAMICS OF A CONCENTRIC TUBES AIRLIFT REACTOR
هيدروديناميكية المفاعل الأنابيب المتمحور ة من نوع Airlift

Author: Aseel Abd Aljabbar أسيل عبد الجبار
Journal: DIYALA JOURNAL OF ENGINEERING SCIENCES مجلة ديالى للعلوم الهندسية ISSN: 19998716/26166909 Year: 2010 Volume: Engineering Sc. Conference Issue: First Pages: 427-444
Publisher: Diyala University جامعة ديالى

Loading...
Loading...
Abstract

ABSTRACT:- In airlift reactors transport phenomena are achieved by pneumatic agitation and circulation occurs in a defined cyclic pattern through a loop. In the present work, the effect of geometrical relations on gas holdup and liquid velocity, and consequently on the gas-liquid mass transfer coefficient, was studied in a 15-liter airlift bioreactor with Ad/Ar = 0.224, Ad : downcomer cross-sectional area, and Ar : riser cross-sectional area. Measurements of the volumetric oxygen transfer coefficient (KLa) were taken in a raw water-air system using a sulfite oxidation method for depleting the oxygen to zero. The unsteady state concentration of oxygen is then measured using DO probe. Different conditions were examined by varying parameters such as superficial air velocity in the riser (Usg), using two types of air sparger which have a remarkable effect on KLa values. The effect is due to their influence on gas holdup and liquid velocity, consequently affecting KLa. Superficial air velocity in the riser (Usg) ranged from 0.03 to 0.06 m.s-1 and KLa varied between 0.01 to 0.07 s-1. Empirical equations were obtained between KLa and Usg as: KLa = 0.28 Usg 0.53 for cross sparger KLa = 0.58 Usg 0.86 for o-ring spargerKeywords:- Airlift, Bioreactor, hydrodynamics, oxygen mass transfer rate.

الخلاصة تتحقق ظاهرة الانتقال في المفاعلات الحيوية من نوع (airlift)بواسطة الخلط الهوائي والتدوير الذي يحدث في دوائر محددة خلال حلقة معينة. تمت دراسة الخصائص الهندسية وتأثيراتها على الغاز المعلق وسرعة السائل وبالتالي على معامل انتقال الكتلة بين السائل والغاز في مفاعل حيوي من نوع airlift) ) ذو حجم (15 ليتر) و Ad/Ar=0.224) ) حيث ان Ad : مساحة المقطع للسائل النازل و Ar : مساحة المقطع للغاز المتصاعد . أخذت قياسات المعامل الحجمي لانتقال الأوكسجين في نظام ماء-هواء باستعمال طريقة أكسدة الكبريتيد لخفض الأوكسجين المذاب إلى الحدود الدنيا ( الصفرية). تم اخذ قياسات الأوكسجين المذاب للحالة الغير المستقرة باستعمال متحسس الأوكسجين المذاب. أجريت التجارب بظروف مختلفة من خلال تغيير عدة عوامل مثل سرعة الغاز الظاهرية في ممر الغاز المتصاعد باستعمال نوعين من موزعات الغاز والتي كان لها تأثير واضح على المعامل الحجمي لانتقال الأوكسجين المذاب. إن التغيير في نوع الموزع آثر على حجم الغاز المعلق وسرعة السائل وبالتالي على مقدار المعامل ألحجمي لانتقال الأوكسجين المذاب. تراوحت قيم السرعة الظاهرية للغاز في ممر الغاز المتصاعد بين (0.03-0.06 ) م/ثا وتراوحت قيم المعامل الحجمي لانتقال الأوكسجين المذاب بين (0.01-0.07) 1/ثا . تم التوصل إلى المعادلة التطبيقية التالية بين KLa وUsg :KLa = 0.28 Usg0.53 for cross spargerKLa= 0.58 Usg0.6 for o-ring sparger


Article
Numerical Study Of Heat Transfer In Cooling Passages Of Turbine Blade

Authors: Ahmed F. Khudheyer --- Hussein T. Dhaiban
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2013 Volume: 19 Issue: 3 Pages: 342-356
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

As the temperature of combustion gases is higher than the melting temperature of the turbine materials, cooling of turbine parts in a gas turbine engine is necessary for safe operation. Cooling methods investigated in this computational study included cooling flow losses. Film-cooling is one typically used cooling method whereby coolant is supplied through holes passage, in present study the holes placed along the camber line of the blade.The subject of this paper is to evaluate the heat transfer that occur on the holes of blade through different blowing coolant rates. The cases of this study were performed in a low speed wind tunnel with two tip gap at small and large (0.03 and 0.09cm) and multiple coolant flow rates through the film-cooling holes. The blowing ratios was studied whereby coolant was injected from holes placed along the tip of a large scale blade model with Reynolds number (2.1 x 105) of the engine was matched. Results showed that baseline Nusselt numbers on the holes were reduced along the holes passage, and heat transfer coefficient is high values at iterance region. Overall, the cooling by holes appears to be a feasible method for prolonging blade life.

درجة حرارة غازاتِ الاحتراق تكون عالية بالمقارنة مع درجةِ حرارة ذَوَبان معادن التوربين, تَبريد أجزاءِ التوربين في محرّك التوربين الغازي ضروريُة لعمله في ظروف أمنة. نظريات التبريد تحققت في الدراسة النظرية بحيث تضمنت خسائر جريان التبريد. التبريد الغشائي (film-cooling) هو احد طرق التبريد النموذجية حيث أن مائع التبريد يجهز من خلال الثقوب, في الدراسة الحالية تقع الثقوب على طول خط المنتصف (camber) لريشة التوربين.هدف هذا البحث هو حساب انتقال الحرارة الذي يحدث داخل ثقوب الريشة من خلال نسب تبريد متغيرة. حالات الدراسة أنجزت على جريان بطيء في النفق الهوائي مع فجوتان للقمة صغيرة وكبيرة (0.03 و 0.09 سم) مع اختلاف نسب مائع التبريد من خلال ثقوب التبريد الغشائي (cooling-film). تم دارسة Blowing Ratios من خلال جريان مائع التبريد الذي يحقن من الثقوب التي تقع على طول القمة مع مقياس كبير لنموذج الريشة مع رقم رينولد ((2.1* 105 للمحرك الذي يكون محسوب. النتائج توضح أرقام نسلت في الثقوب تقل على طول الثقوب, ومعامل انتقال الحرارة يكون ذو قيمة عالية عند منطقة الدخول. عموماً، التبريد بواسطة الفتحات تَبْدو طريقة ملائمة لإطالة عمر الريشة.


Article
The distance variation due to mass transfer and mass loss in (13.6+8) M and (13+10) M binary star systems
تغير البعد نتيجة انتقال وفقدان الكتلة في النظامين النجميين الثنائيين (13.6+8)M و (13+10)M

Author: Mohammed R. Abdulameer محمد رضا عبد الامير
Journal: Iraqi Journal of Physics المجلة العراقية للفيزياء ISSN: 20704003 Year: 2013 Volume: 11 Issue: 20 Pages: 9-16
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

In this research the change in the distance of the two stars in two binary star systems (13.6+8)M and (13+10)M was studied, through the calculations the value (rate of mass transfer) of the two phases of dynamical stages of mass which are mass loss and mass transfer has been extracted in its own way ,by extracting the value of the value of (the distance variation between the two stars) has been found only in the mass transfer stage by using mathematical model ,in mass loss stage and were calculated from the change and the difference between the values of each at different times of binary star system evolution ,it was found that the maximum values of and are in mass transfer state in binary star system , in other words the maximum values of depend on the mass transfer between the two component stars of the binary star system.

في هذا البحث تم دراسة التغير في البعد لنجمين في نظامين ثنائيين وهما (13.6+8)M و(13+10)M ومن خلال الحسابات تم استخراج قيمة (معدل انتقال الكتلة) لمرحلتين من المراحل الديناميكية لحالة الكتلة وهما مرحلة فقدان الكتلة ومرحلة انتقال الكتلة كل حسب طريقته ومن خلال استخراج قيمة تم استخراج قيمة (التغير في البعد بين النجمين) فقط في مرحلة انتقال الكتلة باستخدام نموذج رياضي اما في مرحلة فقدان الكتلة فقد تم حساب و من خلال التغير والفرق بين قيم كل منهما في اوقات مختلفة من اوقات تطور النظام النجمي الثنائي وقد وجد ان قيم و العظمى تكون في حالة مرحلة انتقال الكتلة في النظام النجمي الثنائي اي ان قيم العظمى يعتمد على انتقال الكتلة بين النجمين المكونين لنظام النجوم الثنائية.


Article
Estimation of Extract Yield and Mass Transfer Coefficient in Solvent Extraction of Lubricating Oil
تخمين ناتج الاستخلاص و معامل انتقال المادة في عملية الاستخلاصبالمذيب لزيت التزييت

Author: Hussain K. Hussain حسين قاسم حسين
Journal: Al-Khwarizmi Engineering Journal مجلة الخوارزمي الهندسية ISSN: 18181171 23120789 Year: 2010 Volume: 6 Issue: 1 Pages: 1-13
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

An investigation was conducted to suggest relations for estimating yield and properties of the improved light lubricating oil fraction produced from furfural extraction process by using specified regression.
Mass transfer in mixer-settler has been studied. Mass transfer coefficient of continuous phase, mass transfer coefficient of dispersed phase and the overall mass transfer coefficient extraction of light lubes oil distillate fraction by furfural are calculated in addition to all physical properties of individual components and the extraction mixtures.
The effect of extraction variables were studied such as extraction temperature which ranges from 70 to 110°C and solvent to oil ratio which ranges from 1:1 to 4:1 (wt/wt) were studied.
The results of this investigation show that the extract yield E decreased with decreasing solvent to oil ratio in extract layer and increased with increasing temperature. The fraction of total solvent in the raffinate phase decreased with increasing oil to solvent ratio in raffinate layer and increased with increasing temperature. Solvent to oil ratio in extract layer decreased with increasing temperature and increased with increasing solvent to charge oil ratio at constant temperature. Oil to solvent ratio in raffinate decreased with increasing temperature and increased with increasing solvent to charge oil ratio at constant temperature.
Estimated functions are the best modeling function for prediction extraction data at various operating conditions.
Mass transfer coefficient of continuous phase kc and mass transfer coefficient of dispersed phase kd are increased with increasing temperature and solvent charge to oil ratio at constant temperature. The over all mass transfer coefficient Kod is increased with increasing temperature and solvent to charge oil ratio; while Kod a is increased with temperature and decreased with solvent to charge oil ratio.

تناول هذا البحث ايجاد علاقات لحساب الناتج والخواص لمقطع زيت التزييت الخفيف المحسن من عملية الاستخلاص بالفرفورال باستخدام موديلات رياضية.تم دراسة انتقال المادة في نظام الخلط والفصل تم حساب معامل انتقال المادة في الطور المستمر ومعامل انتقال المادة في الطور المشتت ومعامل انتقال المادة الكلي لعملية الاستخلاص لمقطع زيت التزيت الخفيف بواسطة الفرفورال بالاضافة الى كل الخواص الفيزياوية للمركبات كل على حده وخلائط نظام الاستخلاص . تم دراسة المتغيرات المؤثرة على عملية الاستخلاص والتي هي درجة حرارة الاستخلاص وتتراوح من 70 الى 110°م، والمتغير الأخر هو نسبة المذيب الى الزيت وتتراوح من 1:1 الى 1:4 .اظهرت نتائج هذا البحث بان ناتج الاستخلاص يقل بنقصان نسبة المذيب الى زيت التزييت في طبقة المستخلص ويزداد بزيادة درجة الحرارة . إن نسبة المذيب الكلي في طور الرافيينت يقل بزيادة نسبة زيت التزييت الى المذيب في طبقة الرافيينت ويزداد بزيادة درحة الحرارة .إن نسبة المذيب إلى الزيت في طور الاستخلاص يقل بزيادة درجة الحرارة ويزداد بزيادة نسبة المذيب الى زيت التزييت اللقيم بثبوت درجة الحرارة. إن نسبة زيت التزييت الى المذيب في الرافينيت يقل بزيادة درجة الحرارة ويزداد بزيادة نسبة المذيب الى زيت التزييت اللقيم بثبوت درجة الحرارة .ان الدوال الرياضية التي تم اقتراحها هي تعتبر من افضل الموديلات الرياضية لتمثيل نظام الاستخلاص هذا بمختلف الظروف التشغيلية.يزداد معامل انتقال المادة في الطور المستمر ومعامل انتقال المادة في الطور المشتت بزيادة درجة الحرارة ونسبة المذيب الى زيت التزييت اللقيم بثبوت درجة الحرارة. يزداد معامل انتقال المادة الكلي بزيادة درجة الحرارة ونسبة المذيب الى زيت التزييت اللقيم بينما يزدادa Kod بزيادة درجة الحرارة ويقل بزيادة نسبة المذيب الى زيت التزييت اللقيم.


Article
Influence of Draft Tube Diameter on Operation Behaviorof Air Lift Loop Reactors
تأثير قطر الأنبوب الداخلي على سلوك تشغيل مفاعلات تدوير الهواء

Authors: Laith S. S. Al-Kuffe ليث سالم صبري الكوفي --- Ali Abdul-Rahman Al-Azzi علي عبد الرحمن نصيف
Journal: Al-Khwarizmi Engineering Journal مجلة الخوارزمي الهندسية ISSN: 18181171 23120789 Year: 2010 Volume: 6 Issue: 2 Pages: 21-32
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

The ratio of draft tube to reactor diameters is of decisive importance for the operation behavior of air lift loop reactors. The influence of draft tube geometry was investigated with respect to oxygen mass transfer and mixing time. The diameter ratio was varied between 0.33 and 0.80. The measurements were performed in two loop reactors with liquid capacities of 11.775 and 26.49 liters using aqueous with solutions of different coalescence behavior. The results show that there is no single diameter ratio which would produce most favorable conditions for the two process parameters. With respect to the more important requirements of aerobic cultures, i.e high oxygen mass transfer and efficient mixing, a diameter ratio between 0.5 and 0.6 is recommended. If high liquid velocities in the draft tube are required a ratio of 0.6 should be used.

ان النسبة بين القطر الداخلي الى القطر الخارجي ﺬو اهمية كبيرة جدا في السلوك التشغيلي الديناميكي لمفاعل التدوير الهوائي. ان تاثير الابعاد الهندسية للعمود الداخلي (draft) قد تم دراسته نسبة الى العوامل التشغيلية والتصميمية التالية: انتقال الكتلة للاوكسجين, زمن الخلط وبنسبة قطرية (DD/D) تتراوح بين 0.45 الى 0.59 حجم السائل المستخدم فى المفاعلين هو 11.775 الى 26.49 لترتم استخدام محاليل ذات قابلية مختلفة لتجميع الفقاعات. اظهرت النتائج انه لاتوجد نسبة قطرية محدودة ثابتة هي المفضلة. لجميع العوامل التصميمية بقدر ماتوجد نسبة معينة هي المفضلة لعامل واحد او عاملين دون العوامل الاخرى فمثلا اظهرت النتائج ان النسبة القطرية بين 0.5 الى 0.6 هي الاكثر ملائمة لعاملي انتقال الكتلة وزمن الخلط اما فى حالة الحصول على سرعة عالية للسائل في الانبوب الداخلي (draft) فكانت النسبة القطرية (0.6) هي الامثل.

Listing 1 - 10 of 53 << page
of 6
>>
Sort by
Narrow your search

Resource type

article (53)


Language

English (40)

Arabic and English (11)

Arabic (2)


Year
From To Submit

2019 (1)

2018 (1)

2017 (1)

2016 (4)

2015 (3)

More...