research centers


Search results: Found 14

Listing 1 - 10 of 14 << page
of 2
>>
Sort by

Article
Argon plasma needle source
مصدر توليد ابرة بلازما الاركون

Loading...
Loading...
Abstract

Non thermal argon plasma needle at atmospheric pressure was generated. The experimental set up is based on very simple and low cost electric components that generate electrical field sufficiently high at the electrodes to ionize various gases, which flow at atmospheric pressure. The high d.c power supply is 7.5kV peak to peak, the frequency of the electrical field is 28kHz, and the plasma power less than 15W. The plasma is generated using only one electrode. In the present work the voltage and current discharge waveform are measured. Also the temperature of the working Ar gas at different gas flow and distances from the plasma electrode tip was recorded.

تم توليد ابرة بلازما الاركون غير الحرارية وتحت الضغط الجوي. باستعمال مكونات الكترونية بسيطة وواطئة الكلفة. لها القدرة على توليد مجال كهربائي عالي عند الاقطاب يكفي لتأين الغازات المختلفة والمتدفقة عند الضغط الجوي. ولدت البلازما التي تم دراستها بفولتية متناوبة عند الاقطاب 7.5 كيلوفولت من القمة الى القمة وكانت قدرتها 15 واط وتردد المجال المسلط 28 كيلو هرتز. قدم هذا العمل معلومات عن قياس القولتية والتيار اللذان استعملا في توليد البلازما. كذلك تم قياس درجة حرارة الاركون المتدفق بمستويات تدفق مختلفة من نهاية القطب الكهربائي.


Article
Effect of Atmospheric Non-Thermal Plasma on Adhesion Process of Pseudomonas Spp Bacteria

Authors: Thamir H. Khalaf --- Mohammed Ubaid Hussein --- Abdul Rahman M. G. Al-Fahdawi
Journal: Al-Nahrain Journal of Science مجلة النهرين للعلوم ISSN: (print)26635453,(online)26635461 Year: 2015 Volume: 18 Issue: 3 Pages: 74-79
Publisher: Al-Nahrain University جامعة النهرين

Loading...
Loading...
Abstract

Non-thermal atmospheric pressure plasma has emerged as a new promising tool in medicine. The effectiveness of an Atmospheric Non Thermal Plasma (ANTP) for clinical and biological applications are studied. The effort achieved in this work includes a designing of plasma generating system and examine it on some medical and biological parameters. The dependencies of decreasing the adhesion of bacteria on the applied voltage and distance have been recorded. A series of experiments reveal that this effectiveness is due to the ability of direct discharge to bring charges to samples due to generation of so many mediators like reactive nitrogen species and free radicals. Increasing applied voltage and decreasing gap distance effect on decreasing Numbers of bacteria attached to epithelial cells to half.

تعد البلازما غير الحرارية العاملة بضغط جوي وسيلة ترويجية حديثة في الطب. تم الاعتماد على البلازما الباردة بضغط جوي للتطبيقات البايلوجية والسريرية. يتضمن هذا البحث تصميم لنظام توليد البلازما غير الحرارية في الضغط الجوي الاعتيادي واختباره على التطبيقات الطبية والبايلوجية. الاعتمادات لانخفاض الالتصاق البكتيري على الفولتية المطبقة، المسافة التي تكون مسجلة. وقد بينت سلسلة من الاختبارات بان هذه التأثيرات الناتجة من التفريغ المباشر لجلب الشحنات الى العينات الناتجة من توليد عدد من العوامل مثل أصناف النتروجين المتفاعلة والجذور الحرة. الزيادة بالفولطية المطبقة وتناقص مسافة الفجوة تاثير على انخفاض عدد البكتريا الملتصقة بالخلايا الطلائية الى النصف.


Article
The Study of Electrical Description for Non-Thermal Plasma Needle System
دراسة التوصيف الكهربائي لمنظومة ابرة البلازما غير الحرارية

Authors: Ibrahim Karim Abbas ابراهيم كريم عباس --- Mohammed Ubaid Hussein محمد عبيد حسين --- Hamid H. Murbat حامد حافظ مربط
Journal: Iraqi Journal of Science المجلة العراقية للعلوم ISSN: 00672904/23121637 Year: 2017 Volume: 58 Issue: 3B Pages: 1447-1453
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

In this research, a non-thermal plasma system was designed and a non-thermal plasma needle was manufactured for argon gas operating at normal atmospheric pressure. The electrical description of this system studied by using two different values of voltages (4.9,8) kV. Where the results showed the small amount of electrical current consumed by the system of plasma needle up to several microns of amps, and the value of the electrical current increase with the increasing gas flow, as well as the results, showed that happen a breakdown voltage at (8) kV when gas flow (4 l/min) causing a slight decrease in the electrical current value.

في هذا البحث، تم تصميم وتصنيع منظومة بلازما غير الحرارية لغاز الأرجون والتي تعمل عند الضغط الجوي الاعتيادي. حيث تم دراسة الوصف الكهربائي لهذه المنظومة المصنعة وذلك من خلال استخدام قيمتين مختلفتين من الفولتية (4.9,8) كيلو فولت. حيث اظهرت النتائج التي تم الحصول عليها صغر قيمة التيار الكهربائي المستهلك من قبل منظومة أبرة البلازما غير الحرارية حيث كان بحدود عدة مايكرونات من الامبير ، وكانت قيمة التيار الكهربائي تزداد زيادة طردية مع زيادة تدفق الغاز ، وكذلك اظهرت النتائج حدوث انهيار في الفولتية عندما تكون الفولتية المستخدمة (8) كيلو فولت والتي سببت انخفاض قليل في قيمة التيار الكهربائي عندما يكون تدفق الغاز (4 لتر/دقيقة).


Article
The study of thermal description for non-thermal plasma needle system
دراسة الوصف الحراري لمنظومة إبرة البلازما غير الحرارية

Loading...
Loading...
Abstract

Cold plasma is a relatively low temperature gas, so this feature enables us to use cold plasma to treat thermally sensitive materials including polymers and biologic tissues. In this research, the non-thermal plasma system is designed with diameter (3 mm, 10 mm) Argon at atmospheric pressure as well as to be suitable for use in medical and biotechnological applications.The thermal description of this system was studied and we observed the effect of the diameter of the plasma needle on the plasma, when the plasma needle slot is increased the plasma temperature decrease, as well as the effect of the voltages applied to the temperature of the plasma, where the temperature increasing with increasing the applied voltage . Results showed that the plasma temperature would be low, which enables the use of this system in many medical aspects.

البلازما الباردة هي غاز درجة حرارته منخفضة نسبيا، لذلك هذه الميزة تمكننا من استخدام البلازما الباردة لعلاج المواد الحساسة حراريا بما في ذلك البوليمرات والأنسجة البيولوجية. في هذا البحث تم تصميم منظومة بلازما الأرجون غير الحراري بقطر (3 و 10) مم عند الضغط الجوي، وكذلك لتكون مناسبة للاستخدام في التطبيقات الطبية والبيوتكنولوجية. تم دراسة الوصف الحراري لهذه المنظومة ولاحظنا تأثير قطر ابرة البلازما على درجة حرارة البلازما فانه كلما زاد نصف قطر الابرة فان درجة حرارة البلازما تقل, وكذلك تأثير الفولتية المطبقة على درجة حرارة البلازما حيث تزداد كلما زادت مقدار الفولتية, وأظهرت النتائج أن درجة حرارة البلازما ستكون منخفضة، والتي تمكن من استخدام هذا النظام في العديد من الجوانب الطبية.


Article
Strain specificity in antimicrobial activity of non-thermal plasma
الفعالية الضد ميكروبيه للبلازما الغير حرارية على نوعية السلالات

Authors: Hammad R. Humud حمد رحيم حمود --- Maha Adel Mahmood مها عادل محمود --- Wafaa Abd Al-Razaq وفاء عبد الرزاق
Journal: Iraqi Journal of Physics المجلة العراقية للفيزياء ISSN: 20704003 Year: 2013 Volume: 11 Issue: 20 Pages: 110-115
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

Non-thermal (low-temperature) plasma may act as an alternative approach to control superficial wound and skin infections when the effectiveness of chemical agents is weak due to natural pathogen or biofilm resistance. In this paper an atmospheric pressure plasma needle jet device which generates a cold plasma jet is used to measure the effectiveness of plasma treatment against different pathogenic bacteria and to test the individual susceptibility of pathogenic bacteria to non-thermal argon plasma. It is found that, Gram-negative bacteria were more susceptible to plasma treatment than Gram-positive bacteria. For the Gram-negative bacteria Pseudomonas aeruginosa, there were no survivors among the initial 1x108C.F.U (Colony Forming Unit) after a 40 seconds plasma treatment. The susceptibility of Gram-positive bacteria and the Gram-negative bacteria were species and strain specific. Staphylococcus aureus was the most resistant with 4.5 % survival of the initial 2x106C.F.U. after a 40 seconds plasma treatment. According to species, Staphylococcus aureus had a strain-dependent resistance with 39% and 99% reduction from 2x106C.F.U.of the five studied isolates, respectively, whereas, Escherichia coli had a lower resistance with 76% and 99% reduction after 40 seconds.

البلازما غير الحرارية (منخفضة درجة الحرارة) تعد نهجاَ بديلاَ للسيطرة على الجروح السطحية والالتهابات الجلدية عندما يكون تاثيرالعوامل الكيميائية ضعيفا وذلك يعود لطبيعة المسبب المرضي اوبسبب مقاومة الغشاء الحيوي. لقد استخدم هذا البحث جهاز نفث ابرة البلازما الذي يعمل بالضغط الجوي والذي يولد بلازما نفث باردة لقياس فعالية المعاملة بالبلازما ضد الممرضات البكتيريه المختلفه, ولاختبار الحساسية الفردية للممرضات البكتيرية لبلازما الاركون البارد. وقد وجد ان البكتريا السالبة لصبغة غرام اكثر حساسية عند معاملتها بالبلازما من البكتريا الموجبة لصبغة غرام. بالنسبة للبكتريا Pesudomonas aeraginosa السالبة لصبغة غرام لم تبقى بكتريا حيه من اصل نسبة اللقاح البالغ تركيزها 1× 106مستعمره بكتيرية/ مللتر بعد 40 ثانية من المعاملة بالبلازما. أن حساسية البكتريا السالبة والموجبة لصبغة غرام تعتمد على نوع البكتريا ونوع السلالات ضمن نفس النوع من البكتريا، حيث كانت البكتيريا Staphylococcus aureus أكثر مقاومة من بقية الانواع المدروسة حيث كانت نسبة البقاء 4% من أصل 2×106 مستعمرة بكتيرية/ مللتر بعد معاملتها بالبلازما لمدة 40 ثانية. واظهرت السلالات الخمسة لهذه البكتيريا اختلافا في نسبة مقاومتها حيث وصلت نسبة الاختزال لاحدها الى 39% من اصل 2×106 مستعمره بكتيرية/ مللتر بينما اظهرت بكتيريا Escherichia coli مقاومة اقل وصلت الى 76% لاحد السلالات المدروسة.


Article
Design an Ozone Generator by Using Dielectric Barrier Discharge

Authors: Hamid H. Al-Jobouri --- Hadeel O. Ismaeel
Journal: Al-Nahrain Journal of Science مجلة النهرين للعلوم ISSN: (print)26635453,(online)26635461 Year: 2014 Volume: 17 Issue: 1 Pages: 89-94
Publisher: Al-Nahrain University جامعة النهرين

Loading...
Loading...
Abstract

An Ozone generator was designed according to dielectric barrier discharge (DBD) technique with Oxygen as a feed gas for Ozone generating. The effect of the flow rate on the concentration of the Ozone was studied, the flow rate was varied from 0.6 to 5lit/ min for two values of the gap space between electrodes d= 2 and 4 mm, and two values of the electrode area A= 20 and 36 cm2. Also, the effect of the applied voltage on the concentration of the Ozone was studied, the applied voltage was varied from (1- 9 kV) for the same gap space and electrode area values. It is found that the concentration of Ozone produced increases with increasing voltage, and decreases with increasing flow rate.

تم تصميم وتشغيل منظومه لانتاج الاوزون طبقاً لتقنية تفريغ حاجز العزل الكهربائي بأستخدام الاوكسجين كغاز ادخال لتوليد الاوزون، درس تأثير معدل الجريان على تركيز الاوزون المنتج في المنظومه بأخذ قيم مختلفة لمعدل الجريان ما بين (L/min 5- 0.6) لقيمتين مختلفتين للمسافة بين الاقطاب (d=2,4 mm)، وكذلك لقطبين مختلفين في المساحة ((Ae= 20,36 cm2، ايضاُ تم دراسة تأثير الفولتية المسلطة على تركيز الاوزون وذلك بأخذ فولتيات مختلفة بين1-9 kV) ) لنفس المسافة بين الاقطاب ومساحة القطب ولوحظ ان تركيز الاوزون المنتج يزداد بزيادة الفولتية المسلطة ويقل بزيادة معدل الجريان.


Article
The role of atmospheric non-thermal plasma in the bacteria inactivation
دور البــلازمــا غـير الحـراريـة فـي تعـطــيل البـكـتــيريـا

Loading...
Loading...
Abstract

Non-thermal atmospheric pressure plasma has emerged as a new promising tool in medicine and biology. In this work, A DBD system was built as a source of atmospheric pressure non-thermal Plasma suitable for clinical and biological applications. E. coli and staphylococcus spp bacteria were exposed to the DBD plasma for a period of time as inactivation (sterilization) process. A series of experiments were achieved under different operating conditions. The results showed that the inactivation, of the two kinds of bacteria, was affected (increasing or decreasing) according to operation conditions because they affects, as expected, the produced plasma properties according to those conditions.

تعد البلازما غير الحرارية من الأدوات الحديثة في الطب والبايولوجي. تم في هذا البحث بناء منظومة تفريغ كهربائي خلال حاجز عازل كمصدر للبلازما اللاحرارية في الضغط الجوي الاعتيادي وهي مناسبة للتطبيقات الطبية والاحيائية. وقد تم تعريض نوعين من البكتيريا لبلازما تفريغ الحاجز العازل كعملية تعطيل (تطهير) للبكتيريا. هذا وقد انجزت سلسلة من التجارب تحت ظروف تشغيلية مختلفة وبينت النتائج ان عملية التطهير, لكلا نوعي البكتيريا, تتأثر ( زيادة او نقصان) تبعا للظروف التشغيلية لانها تؤثر, كما هو متوقع, في خصائص البلازما المنتجة تبعا لتلك الظروف.


Article
Effect of the Dielectric Barrier Discharge Plasma on the Optical Properties of SnO2 Thin Film

Authors: Hamid H. Murbat --- Ramiz Ahmad Al-Ansari --- Alaa Khamees Brrd
Journal: Al-Nahrain Journal of Science مجلة النهرين للعلوم ISSN: (print)26635453,(online)26635461 Year: 2016 Volume: 19 Issue: 2 Pages: 80-86
Publisher: Al-Nahrain University جامعة النهرين

Loading...
Loading...
Abstract

In this paper, a dielectric barrier discharge DBD plasma system was used to study effects of the nonthermal plasma on the optical properties of the tin oxide (SnO2) thin films. tin oxide (SnO2) thin were deposed on cleaned glass substrates at 450˚C using spray pyrolysis deposition technique prepared from SnCl4:5H2O solution with concentration (0.1M).The prepared films were exposure to different time intervals (0,2,4,6,8 and 10)min.UV-VIS spectra of the films were studies using optical absorbance measurements which were taken in the spectral region from 190nm to 1100nm. The transmittance and reflectance spectra of the films in the UV-VIS region were also studied.The transmittance T, the Reflectance R, absorption coefficient α, energy gap Eg, extinction coefficient K, refractive index n, dielectric constant ϵ and optical conductivity were studied. It is found that the Reflectance, absorption coefficient, extinction coefficient and optical conductivity were increased with exposure time and the transmittance, energy gap, refractive index, dielectric constant were decreased with exposure time of DBD plasma.

تم في هذا البحث استخدام منظومة الحاجز العازل للتأثير على اغشية (SnO2) الرقيقة, تعمل هذه المنظومة على إنتاج البلازما غير الحرارية عند الضغط الجوي الاعتيادي, وتعمل هذه المنظومة عادة عند الترددات 0.05 و 500kHz وعند فولتية تصل الى 1500 kVolt-100. تحضير أغشية اوكسيد القصدير (SnO2) الرقيقة بطريقة الرش الكيميائي الحراري من رش محمول مكون من كلوريدات القصدير المائية (SnCl4: 5H2O) المذابة في الماء المقطر بتركيز (0.1M) وعلى شرائح زجاجية مسخنة الى درجة حرارة 450˚C.درست اطياف الاشعة المرئية – فوق البنفسجية للاغشية باستخدام حسابات الامتصاص البصري والتي اخذت في المنطقة الطيفية (190-1100) نانومتر. كما درست ايضا النفاذية والانعكاسية للاغشية في المنطقة المرئية – فوق البنفسجية UV-VIS.درس تاثير التعرض للبلازما لكل من النفاذية T, الانعكاسية, الامتصاصية R, معامل الخمود K, معامل الانكسار n و ثابت العزل ϵ. بينت النتائج ان كل من معامل الخمود والجزء الخيالي من ثابت العزل تزداد مع زيادة زمن التعريض للبلازما, بينما يقل كل من النفاذية والانعكاسية والجزء الحقيقي من ثابت العزل ومعامل الانكسار مع زيادة زمن التعريض للبلازما.


Article
The Effect of the Non-Thermal Plasma Needle on Pseudomonas Aeruginosa Bacteria
تأثير البلازما غير الحرارية على بكتيريا سيدوموناس ايروجينوسا

Loading...
Loading...
Abstract

The development in the field of medical physics has led to the use of devices that are manufactured under normal conditions to make tremendous progress in the world of development in medical treatment by using these devices with modern techniques by reducing the use of antibiotics and relying on these tools and devices that link between physics and modern therapeutic medicine. In this research, a non-thermal plasma system for argon gas operated at normal atmospheric pressure was designed, this system was applied on Pseudomonas Aeruginosa bacteria isolated from burn patients from Yarmouk Teaching Hospital. These bacteria were exposed to this system, the results showed that these bacteria were killed at time (5 min) and (8kV) where the argon gas flow rate was (5l/min).

أدى التطور في مجال الفيزياء الطبية الى استخدام الاجهزة التي يتم تصنيعها وتعمل تحت ظروف طبيعية الى احداث طفرة في العلاج الطبي وذلك بتقليل استخدام المضادات الحيوية والاعتماد على هذه الادوات والاجهزة التي تربط ما بين الفيزياء والطب العلاجي الحديث ، في هذه البحث تم تصميم منظومة بلازما غير حرارية لغاز الارجون تعمل عند الضغط الجوي الاعتيادي ، حيث تم تطبيق هذه المنظومة على بكتيريا Pseudomonas Aeruginosa) ) التي عزلت من المرضى المصابين بالحروق من مستشفى اليرموك التعليمي حيث تم تعريض هذه البكتريا لهذه المنظومة حيث تم الحصول على نسبة القتل التام لهذه البكتريا عند الزمن (5دقيقة) وعند فولتية (8 كيلو فولت) وتدفق غاز (5 لتر/دقيقة).


Article
Assessment the effect of non-thermal plasma on Escherichia coli and Staphylococcus aureus biofilm formtion in vitro
تقييم تأثير البلازما غير الحرارية على تكوين الغشاء الحيوي لبكتريا Escherichia coli وStaphylococcus aureus في الزجاج

Author: Jenan Atiyah Ghafil جنان عطية غافل
Journal: Iraqi Journal of Science المجلة العراقية للعلوم ISSN: 00672904/23121637 Year: 2018 Volume: 59 Issue: 1A Pages: 25-29
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

Biofilm formation represents one of the biggest problems facing scientists because of this phenomenon linkage with virulence of bacteria and other clinical environmental problems. In the present study, two clinical isolates, Escherichia coli, and Staphylococcus aureus were exposed to the non thermal plasma for different intervals of time (1, 2, 4, 8, and 16 min). The biofilm was measured post exposing. It was found that 2 min. exposing to non-thermal plasma reduced the biofilm formation by both clinical isolates significantly. It can be concluded that the ability of S. aureus to form biofilm higher than E. coli and exposing for 2 min to non-thermal plasma sufficient to reduce the biofilm formation by both isolates significantly.

يعد تكوين الغشاء الحياتي واحد من اكبر المشاكل التي تواجه العلماء وذلك لان هذه الظاهرة ترتبط مع فوعة البكتريا وكذلك ترتبط بعدد من المشاكل السريرية والبيئية. في هذه الدراسة, عزلتين سريرية وهي الاشرشية القولونية والمكورات العنقودية عرضت الى البلازما غير الحرارية ولأوقات مختلفة (1, 2, 4, 8 و 16 دقيقة). وتم قياس تكون الغشاء الحياتي بعد التعرض. وقد وجد ان تعريض العزلتين للبلازما غير الحرارية ولمدة دقيقتين كافي لاختزال قابلية نوعي البكتريا على تكوين الغشاء الحياتي وبشكل معنوي. ويمكن الاستنتاج ان قابلية المكورات العنقودية اكبر من قابلية الأشرشيا القولونية على تكوين الغشاء الحياتي وان دقيقتين من التعرض للبلازما غير الحرارية كان كافي لأختزال قابليتهما على تكوين الغشاء الحياتي.

Listing 1 - 10 of 14 << page
of 2
>>
Sort by
Narrow your search

Resource type

article (14)


Language

English (13)


Year
From To Submit

2019 (1)

2018 (4)

2017 (2)

2016 (1)

2015 (3)

More...