research centers


Search results: Found 2

Listing 1 - 2 of 2
Sort by

Article
DESIGN THREE PHASE OVERCURRENT RELAYS

Author: Mohammed Y. Suliman, Amer M. Kado
Journal: Tikrit Journal of Engineering Sciences مجلة تكريت للعلوم الهندسية ISSN: 1813162X 23127589 Year: 2008 Volume: 15 Issue: 2 Pages: 78-89
Publisher: Tikrit University جامعة تكريت

Loading...
Loading...
Abstract

A new design of three phase overcurrent relay described in this paper. The performance of the new design shows the ability to obtain any shape of characteristic with high accuracy and distinguish between transient and steady state fault. This design used more precise and flexible model Sachdev linear model for get any characteristic, also fast measurement theory to measure load current for less than half cycle and good hardware system design controlled by Pentium version 4 processor.

مرحلة فرط التيار تستعمل للتمييز بين الزيادة المفرطة بالتيار و تيار الحمل فتقوم المرحلة بفصل الجزء العاطل مع إبقاء باقي أجزاء الشبكة تعمل بشكل طبيعي . تم في هذا البحث تصميم مرحلة فرط التيار ثلاثية الطور , تميز التصميم بالقابلية العالية على تحسس تيار العطل بالإضافة إلى إمكانية تمييزه عن تيار الحمل كما أن عن طريق تغيير البرنامج إمكانية تغيير نوع المرحلة (مرحلة فرط تيار أنية أو مرحلة فرط تيار بتأخير زمني) حيث استعملت تمثيل سكاديف لتمثيل منحنيات التيار-الزمن العكسي لما لهذا النوع من دقة عالية و مرونة في الحصول على إي نوع من المرحلة و ذلك بتغيير المعاملات فقط , بالإضافة إلى استعمال طريقة القياس أظهرت السرعة العالية حيث تم قياس التيار في اقل من نصف دورة أي بحدود 10 ملي ثانية . تم اختبار المرحلة و أظهرت النتائج الكفاءة العالية للتصميم الكمي على جلب البيانات بسرعة عالية و على تحسس تيار العطل و إعطاء إشارة الفصل لقاطع الدورة و تمييزه عن تيار الحمل .


Article
A New Technique Of Microcomputer Based Overcurrent Relay
تقنية جديدة لمرحلة فرط التيار باستخدام الحاسب الدقيق

Author: Mohammed Yahya Suliman محمد يحيى سليمان
Journal: AL Rafdain Engineering Journal مجلة هندسة الرافدين ISSN: 18130526 Year: 2008 Volume: 16 Issue: 5 Pages: 9-19
Publisher: Mosul University جامعة الموصل

Loading...
Loading...
Abstract

Abstract A new technique of three phase overcurrent relay is described in this paper. The performance of the new design shows the ability to obtain any shape of characteristic using exponential type model with high accuracy. Also the new design used more accuracy, fast measurement for peak detection with error less than 2%. The relay tested for normal and very inverse characteristics, also tested for line-to-line fault the results show the ability of discrimination the fault current and isolate the section of the system affected by a fault so that the remaining system can continue to operate normally.Key-words: overcurrent relay, Peak detector, time coordination margin (TC), time multiplier setting (TMS), Programmable Peripheral Interface 8255 (PPI).

الخلاصة تضمن البحث تقنية جديدة في ملرحلة فرط التيار ثلاثية الطور. ان اداء التصميم الجديد اضهر القابلية العالية على تمثيل اي شكل لمنحني التيار-الزمن العكسي بأستعمال المعادلة الأسية و بدقة عالية. كما يتميز التصميم الجديد بأستعمال دائرة تحسس القيمة العظمى التي تتميز بسرعة قياس عالية و دقة تصل نسبة الخطأ فيها أقل من ٢%. تم أختبار المرحلة لنوعين من منحنيات التيار-الزمن العكسي , كما تم أختبار المرحلة في حالة عطل (طور-طور) و أظهرت النتائج تمييز تيار العطل و عزل الجزء العاطل من الشبكة مع بقاء عمل باقي الشبكة بشكل طبيعي.

Listing 1 - 2 of 2
Sort by
Narrow your search

Resource type

article (2)


Language

English (2)


Year
From To Submit

2008 (2)