EFFECTS OF PERCENTAGE OF SERIES COMPENSATION ON SUBSYNCHRONOUS RESONANCE MODES OF POWER SYSTEM
تأثير النسبة المئوية للتعويض نوع التوالي على الترددات الرنينية تحت التزامنية لمنظومة القدرة

Author: Adel Ridha Othman عادل رضا عثمان
Journal: AL-TAQANI مجلة التقني ISSN: 1818653X Year: 2014 Volume: 27 Issue: 1 Pages: E79-E89
Publisher: Foundation of technical education هيئة التعليم التقني

Loading...
Loading...
Abstract

Series compensated power system may lead to a very unusual problem known as SubSynchronous Resonance (SSR) which adversely affects the system stability and under certain operating conditions may result in fatigue breakdown of the turbine – generator shafts. This paper investigates the effects of variation of percentage of series compensation of the transmission line reactance on the excited subsynchronous resonance modes in power transmission system, and these excited modes are calculated for different values of compensation after a three- cycle, three- phase to ground fault incidence at bus bar (B2) of the power system which has been modeled and simulated in Mat-lab/Simulink software.

منظومة القدره التى تم تعويضها بمتسعه على التوالى يمكن ان تؤدى الى حدوث مشاكل غير مؤلوفه تعرف بالرنين التحت التزامنى والذى يؤثر على استقرارية المنظومه و فى حالات تشغيليه محدده يمكن ان تؤدى الى كسر الجزء الرابط بين المولد و التورباين. فى هذا البحث تم دراسة تغيير النسبه المؤيه للتعويض على قيم الترددات الرنينيه المثاره وحساب قيم هذه الترددات لقيم مختلفه من التعويض فى حالة منظومة قدره تتعرض الى عطل ثلاثى الطور الى الارضى و لمدة ثلاث دورات من التردد التزامنى لمنظومة القدره والذى تم محاكاته باستعمال برنامج الماتلاب.


Article
Voltage Stability Enhancement And Loss Reduction Via Optimum Location Of A Series Capacitor
تحسين استقرارية الفولتية وتقليل الخسائر عبر تحديد مكان امثل لوضع متسعة على التوالي

Author: Firas Mohammed Tuaimah
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2010 Volume: 16 Issue: 3 Pages: 5736-5752
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

Series compensation is frequently found on long transmission lines used to improve voltage stability. Due to the long transmission lines, voltage begins to decay as the line moves further from the source. Series compensation devices placed strategically on the line to increase the voltage profile of the line to levels near 1.0 p.u.. This paper presents a novel optimum location and optimum percentage compensation value of a series capacitor as a compensation method to enhance the voltage stability and loss reduction. The proposed method is applied to a 11-bus power system.The load flow analysis using Newton-Raphson approach for the 11-bus test system was designed and tested using MATLAB 7 programming language.

غالبا ما يتم استخدام التعزيز المربوط على التوالي عبر استخدام المتسعة في خطوط النقل وذلك لتحسين الفولتية. بسب المسافات الطويلة لخطوط النقل, فأن الفولتية تبدأ بالأنخفاض كلما ابتعدنا عن المصدر. ولأجل هذا يتم استخدام متسعات موزعة وفق حسابات لتحافض على الفولتية بمستوى 1 للوحدة الثابتة (p.u.). تم في هذا البحث استخدام الية مثلى لوضع او استخدام المتسعة لتحسين الفولتية ولتقليل الخسائر. حيث تم تطبيق الطريقة على منظومة أفتراضية عالمية ذات 11 عقدة (IEEE-11BUS).تم استخدام طريقة الجريان نيوتن- رافسون على هذه المنظومة وأستخدمت اللغة البرمجية .MATLAB 7