research centers


Search results: Found 36

Listing 1 - 10 of 36 << page
of 4
>>
Sort by

Article
Effect of Axle and Dual Spacing on Horizontal Strain Distribution for Flexible Pavement
تاثير الاحمال والمسافات على توزيع الانفعال للتبليط المرن

Authors: Maha O. Al-Mumais مها اسامة --- Abdul Haq H. Abed Ali عبد الحق هادي
Journal: Journal of Engineering and Sustainable Development مجلة الهندسة والتنمية المستدامة ISSN: 25200917 Year: 2010 Volume: 14 Issue: 4 Pages: 153-166
Publisher: Al-Mustansyriah University الجامعة المستنصرية

Loading...
Loading...
Abstract

The flexible pavement layers attach each day by thousands of several types of vehicles according to axle spacing and distribution between each tires (dual spacing) at same axle. These different types of wheel and tires generate deformations or horizontal strain caused fatigue of pavement then reduced pavement life. In this work using three layers system with linear visco-elastic hot mixture layer. Visco-elastic properties obtained from creep test under static load. Kenlayer program used to determine horizontal strain under applied load. It’s concluded that when the axle spacing and dual spacing increase the horizontal strain over lapping reduced. The study obvious that when axle spacing increases from 273 cm (sonata car) till 1524 cm (truck 3-S2) the horizontal strain decreases about 30% .

تتعرض الخرسانة الاسفلتية كل يوم الى الالاف من الاحمال المرورية المختلفة من حيث المسافة بين المحاور و كذلك المسافة بين الاطارات لنفس المحور. هذه الانواع المختلفة من المحاور و الاطارات تولد تشوهات او هبوط في طبقات التبليط الاسفلتي و حدوث تداخل في هذه التشوهات مما سبب فشل التبليط و تقليل العمر الخدمي له. في هذا البحث و لغرض دراسة توزيع هذه التشوهات بالطبقات تم بناء نموذج يتكون من ثلاثة طبقات و على فرض بان طبقة التبليط الاسفلتي تتصرف كمادة لزجة-مرنة حيث تم استخدام النتائج التي تم الحصول عليها من فحص الزحف لنماذج الخرسانة الاسفلتية المصممة بطريقة مارشال.استخدم برنامجKenlayer لحساب قيمة الهبوط اسفل الحمل المسلط، حيث لوحظ من خلال البحث بانه كلما تزداد المسافة بين المحاور يقل تاثير منطقة تداخل المحاور المسببة للهبوط كما لوحظ نفس التاثير عند زيادة المسافة بين الاطارات. بينت الدراسة ان المنطقة المتاثرة بتداخل تاثير المحاور قد انخفضت بمقدار 30% بالنسبة لسيارة سوناتا (273 سم) مقارنة بسيارة الحمل 3-S2 (1524 سم).


Article
GEOMETRICALLY NONLINEAR ANALYSIS OF IMPERFECT LAMINATED COMPOSITE PLATES WITH A VARIABLE FIBER SPACING
تحليل اللآخطية الهندسية للصفائح المركبة المتطبقة والغير مضبطة مع تغير مسافات الألياف

Author: Ali I. Al-Mosawi علي إبراهيم الموسوي
Journal: Al-Qadisiyah Journal for Engineering Sciences مجلة القادسية للعلوم الهندسية ISSN: 19984456 Year: 2011 Volume: 4 Issue: 4 Pages: 439-455
Publisher: Al-Qadisiyah University جامعة القادسية

Loading...
Loading...
Abstract

The primary objective of research is to determine the improved structural efficiency of plates can be with variable fiber spacing. The Post-buckling of laminated composite plate with variable fiber spacing is obtained numerically, using eight node isoparametric quadrilateral elements (serendipity element) with five degree of freedom per node. The mathematical formulation is based on first-order shear deformation theory and von-Karman non-linearity. The effect of the initial geometric imperfection, fiber spacing, orientation fiber, and direction of in-plane loading were considered. Numerical results for boron/Epoxy fiber reinforced laminates are presented for the different effects of the composite plate under in-plane loading. This study showed that the post buckling behavior of composite plate very sensitive for type of distribution fiber and the seventh distribution equation gives maximum buckling load and smallest deformation.

الهدف الرئيسي للبحث هو لتحديد إمكانية تحسين الكفاءة الإنشائية للصفائح من خلال تغير مسافات الألياف. تم حصول النتائج العددية للإنبعاج اللاحق للصفائح المركبة والمطبقة مع ألياف متغيرة المسافات باستخدام عناصر رباعية الشكل ذات ثمانية عقد مع خمسة درجات الحرية للعقدة الواحدة. الصيغة الرياضية موضوعة على نظرية التشوهات القصية الأولى ولاخطية (von-Karman).تم الأخذ بنظر الإعتبار تأثير التشوهات الهندسية الابتدائية؛ مسافات الألياف؛ زاوية تدوير الألياف؛ وإتجاه الأحمال المحورية. النتائج العددية الخاصة بالـطبقات المسلحة بـ(البورون/إيبوكسي) تم تقديمها لمجمل من المؤثرات للصفائح المركبة تحت أحمال محورية. أظهرت هذه الدراسة إن الإنبعاج اللاحق للصفائح جدا حساس لنمط توزيع الألياف وان معادلة التوزيع السابعة تعطي أكبر حمل إنبعاج وأقل تشوه.


Article
DURATION AND SOME DETERMINANTS OF INTERBIRTH INTERVALS IN A SAMPLE OF WOMEN FROM BAGHDAD/ IRAQ

Author: Atheer J Al-Saffar اثير جواد الصفار
Journal: IRAQI JOURNAL OF MEDICAL SCIENCES المجلة العراقية للعلوم الطبية ISSN: P16816579,E22244719 Year: 2012 Volume: 10 Issue: 1 Pages: 12-21
Publisher: Al-Nahrain University جامعة النهرين

Loading...
Loading...
Abstract

BackgroundUnderstanding the practice of birth spacing and factors which influence women’s interbirth interval (IBI) is critical for countries like Iraq with high fertility levels.ObjectivesThis study aimed at measuring the duration of the interval between births and determining some of the factors favored optimal spacing intervals of Iraqi women.MethodsA cross-sectional study was conducted among ever married and having at least 2 live births 472 women during March 2008 in Al-Kadhimyia Teaching hospital. Data were obtained by interview questionnaire, included birth intervals, demographics, and fertility variables. Actual birth interval was measured and data were analyzed using a logistic regression model.ResultsThe mean birth interval was 31.16 ± 21.56 ranged 9–228 months, and 65.6% of interbirth intervals were of less than 36 months. The multivariate regression revealed that older woman, a woman’s husband higher education and having male children were the significant predictors of longer interbirth interval.ConclusionsRelatively short interbirth interval found in the present study may help national health program conveying the message of optimum birth interval, with expanding education and employment opportunities for women can act as a motive for child spacing.Key wordsPregnancy spacing interval, contributing factors, Iraqi women.


Article
The effect of plant spacing spraying the solution nutritious on shoot and root growth and Yield of carrot plant, Local variety Daucus carota L.

Author: Evan Aad Abed Jabir
Journal: Kufa Journal for Agricultural Sciences مجلة الكوفة للعلوم الزراعية ISSN: 20727798 23128186 Year: 2014 Volume: 6 Issue: 3 Pages: 30-42
Publisher: University of Kufa جامعة الكوفة

Loading...
Loading...
Abstract

An experiment was conducted in the Collage of Agriculture Karbala University in AL- Husaina region during the growing season of 2011- 2012 to study the effect of the cultivated distances (5, 10) cm between line and the other and the plant and the other which cultivate in (8 plots) and spraying the nutrient solution SFTB 10 using four concentration (0, 1, 2, 3)gr. L-1 on the vegetative and crop growth attributes for carrot plant .The experiment design used in this study was Randomized Complete Block Design (R.C.B.D) with three replicates, means of treatments was compared using L.S.D at probability level of (0.05), The results showed :- 1-The cultivated distances has a significant effect on improvement the vegetative attributes and thus in the crop attributes. 2-The nutrient solution SFTB 10 has a clear significant effect on the vegetative growth attributes thus the crop attributes for carrot plant. 3-The interaction between the cultivate distances and the nutrient solution SFTB10 had a significant effect on all studied characters of growth and may to give a most accounts in comparison with control treatment which bent to give the little accounts except of the number of total leaves (leaf plant), the phloem thickness, the sap volume and the beta carotene.


Article
Effect of Plant Spacing on Quality Traits of Seeds Three Varieties of Sunflower Crop (Helianthus annuus L.)
تأثير مسافات الزراعة على الصفات النوعية لحبوب ثلاثة أصناف من محصول زهرة الشمس (Helianthus annuus L.)

Authors: Muhsin Ali Ahmed AL-Janabi محسن علي احمد الجنابي --- Saad Edan Abaullah AL-Jebouri سعد عيدان عبدالله الجبوري
Journal: Tikrit Journal for Agricultural Sciences مجلة تكريت للعلوم الزراعية ISSN: 18131646 Year: 2017 Volume: 17 Issue: وقائع المؤتمر العلمي السادس للعلوم الزراعية Pages: 645-656
Publisher: Tikrit University جامعة تكريت

Loading...
Loading...
Abstract

The field experiment was carried out during spring season 2016 at in two locations (Al-Khaziaiefi and Al-Hawi) Al-Alam region-east-north of Tikrit city Center of salhaldeen governorate , The experiment covered included the study of three varieties of sunflower crop , Panam (French variety Lillo , French variety Panam and Iraqi variety Aishaqi 1) with four planting spaces (15 , 20 , 25 and 30 cm) so the experimet contain (12) combination treatments , used R.C.B.D design with three replicates . The results of this study are summarized as follw:- The varieties were significantly influnced in most studied traits , the variety Aishaqi 1 was surpassed in traits : weight of the hay , empty seed ratio , pith to hay ratio also it was oil ratio which were 29.970 , 30.856 , and 30.308 % in the two location Al-khazaiefi and Al-Hawi it's two median respectirely . The space 30 cm was surpassed in traits : weight of the hay , empty seed ratio , pith to hay ratio also it was oil and carbohydrate ratios were surpassed (30.323 , 31.394 and 30.858 % and 6.253 , 7.332 and 6.792 %) in the two locations and it's median respectirely . The interaction between planting spaces and the varieties was significant influnced in most studied trits , the variety Aishaqi 1 at 30 cm space was surpassed with higher level from weight of the hay 243.23 gm in Al-khazaiefi location also it was pith to hay ratio in the two location and it's median in ash and soluble carbohydrate ratio 4.546 and 8.353 % in Al-Hawi location.

أجريت تجربة خلال الموسم الربيعي لعام 2016 م في موقعي الخزيفي والحاوي في ناحية العلم شمال شرق مدينة تكريت مركز محافظة صلاح الدين وتضمنت التجربة دراسة ثلاثة أصناف لمحصول زهرة الشمس هي الصنف الفرنسي ليلو Lillo و الصنف الفرنسي بانام panam و الصنف العراقي اسحاقي١ Aishaqi 1 وأربعة مسافات زراعة هي 15 و 20 و 25 و 30 سم وبهذا تكونت التجربة من (12) معاملة توافقية , طبقت التجربة باستخدام تصميم القطاعات العشوائية الكاملة R.C.B.D وبثلاثة مكررات. وتتلخص اهم نتائج هذه الدراسة في الأتي: تأثرت الأصناف معنويآ في اغلب الصفات المدروسة وتفوق الصنف اسحاقي١ في صفات وزن القش ونسبة البذور الفارغة ونسبة اللب الى القشور وكذلك في نسبة الزيت التي بلغت 29.970 و 30.856 و 30.308% في موقعي الخزيفي والحاوي ومتوسط الموقعين على التوالي . وتفوقت المسافة 30 سم بين النباتات في صفات وزن القش ونسبة البذور الفارغة ونسبة اللب الى القشور وكذلك في نسبتي الزيت والكربوهيدرات والتي بلغت % 30.858 , 31.394 , 30.323 و % 6.792 , 7.332 , 6.253 في كلا الموقعين ومتوسطهما على التوالي . وكان للتداخل بين مسافات الزراعة والأصناف تأثير معنوي في اغلب الصفات المدروسة ، حيث تفوق الصنف اسحاقي١ عند المسافة 30 سم باعلى مستوى من وزن القش 243.23 غم في موقع الخزيفي وكذلك في نسبة اللب الى القشور في كلا الموقعين ومتوسطهما وفي نسبتي الرماد والكربوهيدرات 4.546 و% 8.353 في موقع الحاوي .


Article
Maternal Factors that Determining Birth Spacing Interval among a Sample of the Women at Child Bearing Age

Author: Aqeel Abbas Noaman
Journal: Diyala Journal of Medicine مجلة ديالى الطبية ISSN: 97642219 Year: 2015 Volume: 8 Issue: 1 Pages: 60-65
Publisher: Diyala University جامعة ديالى

Loading...
Loading...
Abstract

Background: Birth interval is the length of time between two successive live births. It might be affected with socio-economic factors related to mother as age, education and parity.Objectives: To determine the rate of birth spacing interval for a sample of women at the child bearing age and to find out any association between maternal factors and birth spacing interval.Subjects and methods: A cross-sectional study was conducted in Al- Takia PHC center by using special questionnaire from 15th September 2012 to 15th September 2013. Sample size was 184 women at child bearing age. Results: Out of 184 women at the child bearing age (60.33%) had birth interval less than two years, (68.5%) below 25 years had birth interval shorter than two years, (60%) and (32.9%) of women with birth spacing interval < 2 years and ≥ 2 years respectively were primary school graduates, (83.8%) and (74%) of the studied women with birth spacing interval < 2 years and ≥ 2 years respectively were housewives, (45.9%) of women with birth interval < 2 years had high parity ( ≥ 5 live births). Conclusions: All studied maternal factors were significantly associated with length of birth interval except mother's work status.


Article
BEARING CAPACITY OF SOFT CLAY IMPROVED BY HEATING THROUGH DIFFERENT SPACING CASED BOREHOLES

Authors: Falah H. Rahil --- Husam H. Baqir --- Hussain N. Alkabee3
Journal: KUFA JOURNAL OF ENGINEERING مجلة الكوفة الهندسية ISSN: 25230018 Year: 2019 Volume: 10 Issue: 1 Pages: 68-77
Publisher: University of Kufa جامعة الكوفة

Loading...
Loading...
Abstract

This paper presents the effect of heat treatment on ultimate bearing capacity and total settlement of soft clay. The soft clay that was used in this study was prepared by mixing Baghdad’s clay with sufficient water content which gives a shear strength of 7 kPa.Seven model tests were carried out on soft clay inside a cubic steel box of 750 mm side length after heat treatment, two of which were used as a reference without treatment for comparison. A special heating system was designed and manufactured for this purpose by using the gas as a source of heating through boreholes. Four square patterns casing boreholes having 3.5 cm in diameter and 30cm in length with spacing 3d, 4d, 5d, 6d and 7d (were d is the diameter of the borehole) and the time of heating was six hours for each model. A monotonic load was applied on an aluminum square model footing of 150 mm length and 20 mm thick placed on the center of surface area of the soft clay until the settlement exceeds 10% of the width footing. The results showed that the bearing capacity increases and the settlement decreases with spacing increasing until some limiting value (5d) then the bearing capacity decreases and the settlement increases. The 5d spacing is the best one where the bearing capacity increases nine times and the settlement decreases to one tenth compared with that without heating.


Article
Detection of Subsurface Cavities by Using Pole- Dipole Array (Bristow's Method)/Hit Area-Western Iraq
تحديد الكهوف تحت-السطحية باستخدام ترتيب قطب- قطبين( طريقة برستو) في منطقة هيت غرب العراق

Authors: Jassim Muhammad Thabit جاسم محمد ثابت --- Ali Mishaal Abed علي مشعل عبد
Journal: Iraqi Journal of Science المجلة العراقية للعلوم ISSN: 00672904/23121637 Year: 2014 Volume: 55 Issue: 2 Pages: 444-453
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

The study area is located within the Hit area, western Iraq. The measurements of Graphical Bristow’s method were carried out by using Pole-dipole array, to delineate the anomaly of apparent resistivity caused by a known cavity target. The survey was applied along two traverses: traverse in W-E direction and traverse in S-N direction above Um El-Githoaa cavity. Data interpretation of the traverse trending W-E, with a-spacing equal to(2m)identified the anomaly of the cavity at a depth of (2.6m), (1.6m) height, and( 9.5m) width, while the actual dimensions of depth, height, and width were (3.80m),( 2.2m), and (12.30m) respectively, with variations of depth equal to (1.2m), high (0.8m), and width( 2.8m). The data interpretation with a-spacing of (3m) over the same travers W-E identified small differences from actual dimensions of the cavity, which are approximately equal to (0.4m), (0.6m), and (1m) for depth, height, and width respectively. This means that the survey by using (a=3m) identified a very accurate detection and location of this cave; more than the survey of (a=2m).Therefore, the survey along the traverse S-N is also performed with (a=3m). The data interpretation indicated that the cavity of depth, height, and width are (3.3m),( 2.20m), and(18.6m) respectively, which are approximately the same as the actual dimensions of the cavity with small variations of about (0.5m) depth, (0.4m) high, and (1m) width. It is concluded that the a-spacing is a very important factor, because of its effect on the accurate determinations of subsurface cavity. So, it must be taken into consideration in choosing a-spacing in the filed before taking the measurements by using Bristow's method.

تقع منطقة الدراسة في محافظة الآنبار(منطقة هيت) غرب العراق. آخذت القياسات بطريقة برستو بالاعتماد على ترتيب قطب –قطبين ،وذلك لتحديد الشذوذ الناتج عن تأثير أحد الكهوف .توزعت القياسات على امتداد مسارين متعامدين فوق كهف أم جذوع،اذ كان أحداهما باتجاه غرب–شرق والأخر بأتجاة جنوب- شمال .تفسير البيانات المأخوذة بأمتداد المسار المتجه غرب– شرق وبفاصلة قطبية a تساوي)2 مترا)،أستطاع من تمييز شذوذ الفجوة على عمق (2.6 متر)،ارتفاع (1.6مترا)،وعرضها( 9.5 مترا). بينما الأبعاد الحقيقية الى الفجوة أسفل مسار المسح من القياسات الحقلية للعمق ،الارتفاع ،والعرض كانت (3.8 مترا)، (2.2مترا)،و(12.3مترا) على التوالي. مع وجود فرق بحدود ) 1.2مترا) الى العمق, الارتفاع( 0.8 مترا)،والعرض (2.8مترا).أما تفسير المعطيات الى الفاصلة القطبية a=3 مترا لنفس المسار فقد أظهرت اختلاف قليل عن الأبعاد الحقيقية للكهف وتساوي تقريبا الى (0.4مترا)،) 0.6مترا)، و(1.0مترا) الى العمق، ألأرتفاع،والعرض على التوالي. يتبين مما تقدم أن المسح باستعمال الفاصلة القطبية =a)3) مترا أستطاع أن يحدد الموقع والأبعاد الهندسية لكهف أم جذوع بدقة أكبر من المسح بفاصلة قطبية تساوي =a)2) مترا. لذلك تم أنجاز المسح بأمتداد المسار المتجه جنوب-شمال بفاصلة قطبية =a)3) مترا. أشارت تفسيرات المعطيات الحقلية بأمتداد هذا المسار الى وجود كهف أم جذوع على عمق،أرتفاع،وعرض يساوي الى( 3.3 مترا)،(2.2مترا)، و)18.6مترا) على التوالي. وهذه النتائج تساوي تقريبا الأبعاد الحقيقية مع وجود فارق قليل في العمق يساوي (0.5مترا) ،الارتفاع (0.4مترا) ،والعرض( 1.0 مترا). ومن الواضح أن أختيارالفاصلة القطبية (a ) المناسبة عامل مهم جدا في تحديد التكهف تحت السطحي ، لذلك يجب ان نأخذ بنظر الاعتبار تحديد هذا العامل قبل أجراء المسح بطريقة برستو.


Article
BEHAVIOUR OF WIDE REINFORCED CONCRETE BEAMS WITH DIFFERENT SHEAR STEEL PLATES SPACING
تصرف العتبات الخرسانية المسلحة العريضة بأختلاف المسافات بين صفائح حديد القص

Authors: Amer M. Ibrahim --- Mohammed J. Hamood --- Ahmed Abdullah Mansor
Journal: Journal of Engineering and Sustainable Development مجلة الهندسة والتنمية المستدامة ISSN: 25200917 Year: 2016 Volume: 20 Issue: 5 Pages: 120-135
Publisher: Al-Mustansyriah University الجامعة المستنصرية

Loading...
Loading...
Abstract

This paper presents an experimental investigation on the behavior of wide reinforced concrete beams with different shear steel plate spacing. Four reinforced concrete wide beams with the dimensions of 215x560x1800mm are investigated. The variables studied in this work is using the 10mm stirrups with 125mm spacing and 3mm thickness steel plate with spacing 125, 166 and 250mm instead of reinforcing stirrups. Shear steel plates is a good alternative for stirrups and gives identical results in yield and ultimate loads and increase the ductility by 55% and reduced the strain in exterior and interior legs by 17% and 46% respectively compared with stirrups also reduced the total weight of wide beams by 2.7%. By increasing the spacing of shear steel plate by 33% and 100%, the results showed that the yield load reduced to 5% and 12% respectively, but the deflection was increased with 2% and 16% respectively(at yield). The strain in interior legs is more than the strain in exterior leg (having spacing 125, 166 and 250mm) by 31%, 70% and 1% respectively. ACI 318-14(1) and EC 2(2) codes are given a predicted deflection less than the experimental deflection by 19% and 21% on average respectively.

يتضمن هذا البحث دراسة عملية لتصرف العتبات الخرسانية العريضة بأختلاف المسافات بين صفائح حديد القص. اشتملت الدراسة على صب اربع عتبات خرسانية مسلحة عريضة بابعاد (560x215x1800)ملم. لقد تم دراسة متغيرات عديدة، منها استخدام اطواق بقطر 10ملم بمسافات 125ملم واستخدام صفائح من الحديد بسمك 3ملم وبمسافات 125، 166 و 250ملم بدلا من حديد القص. ان استخدام الصفائح كبديل عن الاطواق اعطى تطابق في نتائج حمل الخضوع والفشل وزاد من المطيلية بنسبة 55% وقلّت فيه الانفعالات في الساق الخارجية والداخلية بنسبة 17% و46% على التوالي مقارنة مع الاطواق اضافة الى تقليله الوزن الكلي للعتبات العريضة بنسبة 2.7%. ان زيادة المسافات بين صفائح حديد القص بنسبة 33% و 100%، قلل من حمل الخضوع بنسبة 5% و12% على التوالي، ولكن زاد من الهطول بنسبة 2% و16% على التوالي (في مرحلة الخضوع). ان الانفعال في الساق الداخلية اكبر من الانفعال في الساق الخارجية (للمسافات 125 ، 166 و250ملم) بنسبة 31%، 70% و 1% على التوالي. الكود الامريكي ACI 318-14(1) والاوربي EC 2(2) اعطى نتائج للهطول اقل من النتائج العملية بنسبة 19% و 21% على التوالي.


Article
The Optimal Spacing between Elliptic Tubes Cooled by Free Convection Using Constructal Theory

Authors: Ahmed Waheed Mustafa --- Jaafar Ahmed Zahi
Journal: AL-NAHRAIN JOURNAL FOR ENGINEERING SCIENCES مجلة النهرين للعلوم الهندسية ISSN: 25219154 / eISSN 25219162 Year: 2017 Volume: 20 Issue: 3 Pages: 762-769
Publisher: Al-Nahrain University جامعة النهرين

Loading...
Loading...
Abstract

The optimal spacing between elliptic tubes cooled by free convection is studied numerically. A row of isothermal elliptic tubes are installed in a fixed volume and the spacing between them is selected according to the constructal theory (Bejan's theory). In this theory the spacing between the tubes is chosen such that the heat transfer density is maximized. A finite volume method is employed to solve the governing equations; SIMPLE algorithm with collocated grid is utilized for coupling between velocity and pressure. The range of Rayleigh number is (103 ≤ Ra ≤ 105), the range of the axis ratio of the tubes is (0 ≤  ≤ 0.5), and the working fluid is air (Pr =0.71). The results show that the optimal spacing decreases as Rayleigh number increases for all axis ratios, and the maximum density of heat transfer increases as the Raleigh number increases for all axis ratios and the highest value occurs at axis ratio ( =0) (flat plate) while the lowest value occurs at ( =0.5) (circular tube). The results also show that the optimal spacing is unchanged with the axis ratio at constant Rayleigh number.

البعد الامثل بين انابيب بيضوية مبردة بالحمل الطبيعي درس عدديا. صف من الانابيب البيضوية ثابتة درجة الحرارة نصبت في حجم محدد والبعد بينهم اختير بموجب نظرية التشييد (نظرية بيجان). في هذة النظرية البعد اختير بيحث تكون كثافة انتقال الحرارة اقصى ما يمكن. طريقة الحجم المحدد استخدمت لحل المعادلات الحاكمة, خوارزمية SIMPLE مع شبكة متحدة الموقع استخدمت للربط بين السرعة والضغط. مدى رقم رايلي (103 ≤ Ra ≤ 105) ومدى نسبة الاحداثي للانابيب (0 ≤  ≤ 0.5) ومائع التشغيل هو الهواء (Pr=0.7). بينت النتائج ان البعد الامثل يقل مع زيادة رقم رايلي لكل نسب الاحداثيات وكثافة انتقال الحرارة العظمى تزداد مع زيادة رقم رايلي لكل نسب الاحداثي وقيمتها العليا تحدث عند نسبة احداثي , =0),صفيحة مستوية) وقيمتها السفلى تحدث عند نسبة احداثي , =0.5) انبوب دائري).بينت النتائج ايضا ان البعد الامثل لا يتغير مع نسبة الاحداثي عند رقم رايلي ثابت.

Listing 1 - 10 of 36 << page
of 4
>>
Sort by
Narrow your search

Resource type

article (36)


Language

English (18)

Arabic and English (11)

Arabic (7)


Year
From To Submit

2019 (2)

2018 (1)

2017 (6)

2016 (5)

2015 (5)

More...