research centers


Search results: Found 2

Listing 1 - 2 of 2
Sort by

Article
Numerical Study of Fluid Flow and Heat Transfer over a Bank of Oval-Tubes Heat Exchanger with Vortex Generators
دراسة عددية للجريان وانتقال الحرارة في مبادل حراري من صف من الأنابيب البيضوية بوجود مولدات الدوامة

Author: Abdulmajeed A. Ramadhan عبد المجيد عبد الحميد رمضان
Journal: Anbar Journal of Engineering Sciences مجلة الأنبار للعلوم الهندسية ISSN: 19979428 Year: 2012 Volume: 5 Issue: 1 Pages: 88-108
Publisher: University of Anbar جامعة الانبار

Loading...
Loading...
Abstract

The present work represents a two-dimensional numerical investigation of forced laminar flow heat transfer over a 3-rows oval-tube bank in staggered arrangement with rectangular longitudinal vortex generators (LVGs) placed behind each tube. The effects of Reynolds number (from 250 to 1500), the positions (3 in x-axis and 2 in y-axis) and angles of attack (30o and 45o) of rectangular VGs are examined. The study focuses on the Influence of the different parameters of VGs on heat transfer and fluid flow characteristics of three rows oval-tube banks. The characteristics of average Nu number and skin friction coefficient are studied numerically by the aid of the computational fluid dynamics (CFD) commercial code of FLUENT 6.3. The results showed increasing in the heat transfer and skin friction coefficient with the increasing of Re number and decreasing the relative distance of positions of LVGs. It has been observed that the overall Nuav number of three oval-tubes increases by 10–20.4% and by 10.4–27.7% with angles of 30o and 45o respectively, with increasing in the overall average of skin friction coefficient of three oval-tubes reached to 53% and 72% with two angles used respectively, in comparison with the case without VGs.

يتناول البحث المقدم دراسة عددية ثنائية البعد لجريان طباقي لفحص خواص الجريان وانتقال الحرارة لثلاثة صفوف من أنابيب بيضوية الشكل (عند ثبوت درجة حرارة السطح) مرتبة بشكل متخالف بوجود زوج من مولدات الدوامة مستطيلة المقطع إلى الخلف من كل أنبوب. ركزت الدراسة التي أجريت ضمن مدى عدد رينولدز (1500-250) على تأثير مواقع وزوايا الهجوم لمولدات الدوامة على تحسين انتقال الحرارة وتأثيرها في معامل الاحتكاك السطحي للأنابيب. تم اختيار ستة مواقع (ثلاثة باتجاه الجريان واثنان باتجاه متقاطع معه) تمثلت في ست مسافات نسبة إلى نصفي قطري الشكل البيضوي، إضافة إلى اختيار زاويتي هجوم (30o) و (45o). تم حل المعادلات الحاكمة باستخدام البرنامج العددي المسمى (FLUENT 6.3) مع اعتبار الجريان انسيابي والحالة مستقرة. أظهرت الدراسة تحسناً في انتقال الحرارة ممثلاً بمعدل عدد نسلت للأنابيب بسبب وجود مولدات الدوامة مقارنة مع الحالة في عدم وجودها، وأن هذا التحسن يقل بزيادة المسافات النسبية لمواقع مولدات الدوامة. حيث بلغ أعلى تحسن نسبي في المعدل الإجمالي لعدد نسلت (20.4%) و (27.7%) عند المسافات النسبية الصغيرة مع زاويتي لهجوم (30o) و (45o) على التوالي. وأن الزيادة في المعدل الإجمالي لمعامل الاحتكاك السطحي للأنابيب الثلاثة المرافقة للتحسن في انتقال الحرارة بلغت (53%) و (72%) لزاويتي الهجوم أعلاه على التوالي.


Article
Effect of Delta–Winglet Vortex Generators on a Forced Convection Heat Transfer in an Asymmetrically Heated Triangular Duct
تاثير توليد الدوران على انتقال الحرارة القسري في مجرى مثلث مسخن تسخينا غير متجانس

Loading...
Loading...
Abstract

An experimental investigation is performed to study the friction factor ( f ) and convection heat transfer coefficient (h) behavior in an asymmetrically heated equilateral triangular duct by using delta–winglets vortex generators which are embedded in a turbulent boundary layer. Two side walls of the heated test section are electrically heated with a constant heat flux, whereas the lower wall is indirectly heated. Reynolds number (Re) is ranged from (23,000) to (58,000). Two sizes and three attack angles of vortex generators are studied here for three cases; single, double, and treble pairs of generators. Each pair was supported in one wall of the test section at the various locations from the leading edge. The indicated results that friction factor ( f )and Nusselt number (Nu) are relatively proportion with the size, number and the inclination angle of the generators. The ( f ) decreases as airflow rate increases whereas Nu number increases. The present data of ( f ) is less than the data of Chegini by about (6.5 %) and overpredicts the data of Altemani by about (1.7 %).

يتناول هذا البحث دراسة تجريبية لسلوك معامل الاحتكاك و تحسين معامل انتقال الحرارة بالحمل ألقسري (ممثلاً بعدد نسلتNu ) في مجرى مثلث المقطع مسخن تسخيناً غير متجانس باستخدام مولدات الدوامية نوع (Delta-Winglet) مغمورة في الطبقة المتآخمة المضطربة. إن الجدارين الجانبيين لمقطع الاختبار مسخنان تسخيناً كهربائياً معتمدِينَ ثبوت الفيض الحراري كشرطٍ حدي، في حين أن الجدار السفلي مسخن بطريقة غير مباشرة. تراوح عدد رينولدز بين (23.000) إلى (58.000) خلال التجارب المختبرية. تم دراسة حجمين وثلاث زوايا لمولد الدوامية ولثلاث حالات والتي هي؛ زوج مفرد وزوجين وثلاثة أزواج من مولدات الدوامية حيث تم تثبيت كل زوج على السطح الداخلي لجدار مقطع الاختبار عند مسافات مختلفة من حافة المقدمة. لوحظ أن معامل الاحتكاك ( f ) ورقم نسلت ( Nu ) تناسبا طرديا مع حجم مولدات الدوامية وعددها وزاوية انحرافها، بينما يتناقص معامل الاحتكاك مع زيادة معدل تدفق الهواء في حين أن عدد نسلت يتزايد طرديا. تم استخراج معادلات إرتباطية لمعظم الحالات ولكل من معامل الاحتكاك وعدد نسلت وقد وجد أن معامل الاحتكاك كان اقل من القيم التي أوجدها الباحث Chegini بحوالي (6.5%) وأعلى من تلك التي أوجدها الباحث Altemani بحوالي (1.7%).

Listing 1 - 2 of 2
Sort by
Narrow your search

Resource type

article (2)


Language

Arabic and English (1)

English (1)


Year
From To Submit

2012 (1)

2007 (1)