research centers


Search results: Found 5

Listing 1 - 5 of 5
Sort by

Article
Evaluation of the Performance of the Dora Refinery Wastewater Treatment Plant

Authors: Muwafaq A. Abed --- Rafa H. Al-Suhaili
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2008 Volume: 14 Issue: 4 Pages: 3020-3035
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

Oil refineries are major contributors to local environmental problems .The main pollutants are oil , dissolved components , spent acids , suspended solids, sludge . Technically it is possible to remove all these pollutants by Physical , chemical and biological means .Oil is initially removed in the (API) separators , by skimming, while the heavy particles by scrapping . Further removal of discrete particles is done by gravity settlement in the primary settlement tank .The remaining suspended matter is removed by chemicals , that are added in the flocculation tank , while further flocs are removed in the air flotation tank . The biological treatment follows to remove the biological pollutants , usually followed by secondary settlement to reduce the flux of suspended particles carried with the effluent water. This thesis deals with the Dora refinery wastewater treatment plant , its present performance in comparison with the designed treatment performance and its final effluents compared with the Iraqi discharged water quality limitations .In order to identify the characteristics of the refinery effluents and to evaluate the performance of the refinery wastewater treatment plant , wastewater from different treatment stages were analyzed for various physical and chemical parameters . Using these parameters as the criteria of performance , comparisons were made between the actual and the designed performance for various potential pollutants. The sampling was conducted during 6 months from May to October 2006 , with two samples in each month for each of the units, one before , and one after.The results showed that the wastewater treatment plant in Al-Dora Refinery performed significantly, where high removal efficiencies , were obtained. For T.S.S , Oil , COD , BOD , Sulfide and Phenol which were 95% , 88% , 86% , 81% , 85% and 97% respectively . And the plant was not very efficient in NH3 , SO4 and PO4 removal .

ان المصافي تعتبر عالميا مساهم رئيسي في مشاكل البيئة الموقعية . اهم الملوثات الناتجة من المصافي والتي تنصرف مع المياه هي النفط ومركباته ,المواد المذابة والعالقة , الحوامض , الحمأة وغيرها . فنيا بالامكان ازالتها جميعا باساليب فيزياوية , كيمياوية وبايلوجية .حيث يتم ازالة النفط اولا في محطة المعالجة في خزانات خاصة للعزل وذلك بترك المياه فيها وقشط النفط الطافي على السطح وكذلك قشط المواد المترسبة في القعر . وتكون عملية الفصل في هذه الخزانات بفعل الجاذبية الارضية . تلي هذه المرحلة عملية فصل للمواد العالقة وذلك بخلط مواد كيمياوية مخثرة مع المياه في خزانات التخثير والدمج ومن ثم يتم تطويف المواد العالقة والمتكتلة في خزانات التطويف حيث يتم قشطها من السطح ومن قعر الخزان باستخدام القاشطات الخاصة لذلك . تتبع هذه العمليات عملية المعالجة البايلوجية , والتي يتم فيها معالجة المواد الذائبة بفعل الاحياء المجهرية (البكتريا ) ومن ثم يتم فصل هذه الملوثات وترسيبها في احواض الترسيب النهائي لفصل ما تبقى من المواد العالقة والمتجمعة والاحياء الحية المجهرية لتقليل جريانها مع المواد المنصرفة الى النهر. المعالجة البايلوجية في مصفى الدورة تستخدم التهوية الممتدة ووحدات الحمأة المنشطة . يتوفر في وحدات المشروع الاجهزة اللازمة للقشط والخلط والتهوية , وأحياء مجهرية حية تتغذى على الملوثات المجهرية . تستخدم هذه الدراسة أسلوب البحث والتحليل الاحصائي للبيانات المستحصلة من قراءات التحاليل الكيميائية للنماذج المأخوذة من مختلف المواقع في محطة المعالجة . وطريقة اخذ النماذج المتبعة كانت نموذج قبل وبعد كل وحدة من وحدات محطة المعالجة ولمدة ستة اشهر وللفترة من ايار وحتى تشرين الاول من عام 2006 وبواقع فحصين كل شهر وللملوثات:- (pH ,Oil , T.S.S , BOD5 ,COD ,N-NH3 ,Sulfide ,Sulfate , Phosphorous and Phenol ) النتائج اظهرت الاداء الكفوء لمحطة المعالجة في ازالة الملوثات (T.S.S ,OIL ,BOD , COD ,Sulfide , Phenol ) حيث سجلت اعلى نسبة ازالة لهذه الملوثات وهي 95% , 88% , 86% , 81% , 85% و97% على التوالي وكذلك النتائج اظهرت ان محطة المعالجة ليست كفوءة جدا في ازالة الملوثات NH3 , SO4 and PO4 .


Article
Biological Phosphorus and Nitrogen Removal from Wastewater Using Moving Bed Biofilm Reactor (MBBR)
الازالة البيولوجية للفسفور والنتروجين من مياه الصرف الصحي باستخدام مفاعل الطبقة البيولوجية المتحركه

Authors: Mudhaffar S. Al-Zuhairy --- Zainab Bahaa --- Walaa S. Mizeel
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2015 Volume: 33 Issue: 7 Part (A) Engineering Pages: 1731-1739
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

In this research, an experimental study to evaluate nutrient removal from Al-Rustamiyah wastewater by a moving bed biofilm process was investigated.The moving bed biofilm reactorMBBR consisted of five reactors in series with one anoxic reactor MBBR-1, two aerobic reactor MBBR-2 and MBBR-3, outlet chamber and the flocculation part with dosing unit, that were operated continuously at different loading rates of phosphorus and nitrogen.The MBBR tankswere filled with suspended plastic carriers (AnoxKaldnes K5), with a 50% filling ratio. Under optimum conditions, almost complete nitrification with average ammonium removal efficiency of 82% was achieved.The average phosphorus and total nitrogen removal efficiencies were 76.79% and70%, respectively.

تم في هذه البحث, دراسة تجريبية لتقييم ازالة المغذيات من مياه الصرف الصحي ( الرستمية ) من خلال الطبقة البيولوجية المتحركة .تتألف منظومة الطبقة البيولوجية المتحركة (MBBR) من خمس مفاعلات متسلسلة تعمل على مختلف معدلات الحمل من الفوسفور والنيتروجين. وهي حوض غياب الأوكسجين، حوض التحلل الهوائي عدد 2، حوض التصاريف الخارجة و حوض التلبيد. حيث تم ملئ الاحواض الثلاث الاولى بالحوامل البلاستيكية Carriers وبنسبة ملء قدرها 50%. تحت الظروف المثلى، وقد تحقق النترجة تقريبا كاملة مع معدل كفاءة إزالة الأمونيوم 82٪. وكان معدل كفاءة ازالة الفوسفور والنتروجين الكلي 76.79٪ و 70٪ على التوالي.


Article
EVALUATION OF ENVIRONMENTAL SUSTAINABILITY INDICATORS OF NORTHERN RUSTIMEH WASTEWATER TREATMENT PLANT IN BAGHDAD, IRAQ, USING SIMAPRO7.1 PROGRAM
تقييم مؤشرات الاستدامة البيئية لمحطة الرستمية الشمالي لمعالجة مياه الصرف الصحي في بغداد ، العراق ، باستخدام برنامج SimaPro7.1

Authors: Mohammad Ali Alanbari --- Mais Salim Muter
Journal: Journal of Engineering and Sustainable Development مجلة الهندسة والتنمية المستدامة ISSN: 25200917 Year: 2018 Volume: 22 Issue: 5 Pages: 188-199
Publisher: Al-Mustansyriah University الجامعة المستنصرية

Loading...
Loading...
Abstract

The importance of the management of wastewater treatment plants is the process of purification of wastewater from impurities, suspended materials, pollutants and organic matter to be re-usable (non-human) or to be suitable for disposal in the waterways without causing pollution. Wastewater treatment involves several physical, chemical and biological phases. Because any wastewater treatment plant (WWTP) has environmental risk and negative impact, it is necessary to assess environmental sustainability indicators and thus can diagnose their risks and find solutions to reduce their environmental and health impacts in order to preserve the essential elements of the environment (water, air and soil) and on the conservation and sustainability of the natural resources of generations. There are many software programs designed to assess environmental sustainability indicators for any sewage treatment plant. SimaPro7.1 is one of several programs which are used to count and determine the ecological (environmental) effects related to wastewater treatment technologies. In this study, SimaPro7.1 has been used to inventory test namely the analysis of inputs to the plant, such as materials used in stage of construction of the plant, incoming wastewater, consumed energy, quality of treated wastewater and quantity of sludge produced, as well as the analysis of effluents to water and emissions air and assess an effects caused by Northern Rustimeh WWTP. An outcome from Life Cycle Assessment (LCA) shows the pollutant which emitted to all environment sub-compartment such as Carbon monoxide, Lead, Dinitrogen monoxide and another pollutant which causes impacts and damages to environment by 12.4GPt to every (1m3) of sewage. The results show that generality effects were (global warming, respiratory inorganics and nonrenewable energy); also most damages were on human health, climate change and resources.


Article
Performance Evaluation of Al-Khadraa' Wastewater Treatment Plant, Mosul-Iraq
تقييم أداء محطة الخضراء لمعالجة مياه الصرف الصحي، الموصل- العراق

Authors: Ayad Fadeel Qasim1 أياد فضيل قاسم1 --- Omer Moayad Khalil Al-Obady2 عمر مؤيد خليل العبادي2
Journal: Tikrit Journal of Pure Science مجلة تكريت للعلوم الصرفة ISSN: 18131662 Year: 2018 Volume: 23 Issue: 7 Pages: 42-46
Publisher: Tikrit University جامعة تكريت

Loading...
Loading...
Abstract

The study aims to evaluate the operational efficiency of Al-Khadraa' wastewater treatment plant and the compatibility of the quality of treated water with the Iraqi standards for disposal into rivers and valleys. The study showed that there are large variations in the quantities and quality of the influent to the plant which sometimes lead to stop operational units of the plant and this has an adverse effect upon the plant function. The results showed that the strength of the influent is classified as weak to medium. The average BOD5/COD ratio is equals to 0.6. Also it seemed that the efficiency of the treatment was weak and the quality of the effluent is out of the Iraqi standards for disposal into rivers and valleys. The percentage removal of BOD, COD, TSS, PO4, NH3 were 83.15%, 79%, 69.7%,56.15%,41.88% respectively. The sequence of removal efficiency was in the order of: NH3 تهدف هذه الدراسة إلى تقييم الكفاءة التشغيلية لمحطة معالجة الخضراء ومدى توافق نوعية المياه المعالجة مع المحددات العراقية للطرح في الأنهار والمجاري المائية. تبين من خلال الدراسة أن هنالك تغاير كبير في كميات ونوعية المياه الداخلة إلى المحطة ما يؤدي ذلك إلى إيقاف تشغيل المحطة في بعض الاحيان وانعكاس ذلك سلبا على أداء المعالجة في المحطة. بينت النتائج أن شدة تركيز المياه الداخلة الى المحطة يمكن تصنيفها متوسطة- ضعيفة وان نسبة BOD5/COD تساوي 0.6 , كما أظهرت النتائج أن كفاءة المعالجة في المحطة ضعيفة وأن نوعية المياه المعالجة لا تتطابق مع المحددات العراقية للطرح في الأنهار والمجاري المائية إذ بلغت نسب الإزالة لكل من BOD، COD ،TSS ، PO4، NH3 (83.15%، 79% و69.7%، 56.15%، 41.88%)على التوالي وكفاءة الإزالة كانت على الترتيب NH3


Article
Performance Evaluation of Sequencing Batch Reactor and Conventional Wastewater Treatment Plant based on Reliability assessment
مقارنة بين المفاعل ذو العمليات المتسلسلة ومحطة معالجة مياه المجاري التقليدية استنادا إلى تقييم الموثوقية

Authors: Shatha Abdulrazzak Jasim شذى عبد الرزاق جاسم --- Basim Hussein Khudair باسم حسين خضير
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2017 Volume: 23 Issue: 11 Pages: 97-112
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

Baghdad city has been faced numerous issues related to freshwater environment deteriorations due to many reasons, mainly was the discharge of wastewater without adequate treatment. Al-Rustamiya Wastewater Treatment Plant (WWTP) have been constructed among many plants in Baghdad city to reduce the amount of wastewater discharged into natural environment and its subsequent adverse effects. This study was conducted to evaluate the performance of the plant which consist of a conventional activated sludge (CAS) and sequencing batch reactors (SBR) systems as secondary treatment units and its ability to meet Iraqi specifications. A reliability level determination and analysis also were conducted to find the plant's stability and its capability to produce effluents that met the local standards. Coefficient of Reliability (COR) determination was done for effluent's concentrations of BOD5, COD, and TSS obtained from Al-Rustamiya WWTP for two years' data operation (2015-2016), using Iraqi standards concentrations. Generally, the results showed the effectiveness of Al-Rustamiya WWTP-(CAS and SBR system) was a major concern due to inadequate sewage treatment and that the plant effluents of both systems selected parameters BOD5, COD and TSS are not meeting the Iraqi standards due to many problems mainly were operational problems result in overall poor performance.

تواجه مدينة بغداد العديد من التحديات فيما يتعلق بالحفاظ على البيئة المائية من التدهور نتيجة الى العديد من الاسباب اهمها هو طرح مياه المجاري الغير معالجة بصورة مناسبة. مشروع الرستمية هو واحد من بين العديد من المحطات المنشأه لمعالجة مياه المجاري وتقليل الاثار الكارثيه الناتجه عن طرحها بدون معالجة, لذلك كان من الضروري تقييم اداء هذه المحطة التي تستخدم كل من نظام الحماءة النشطه التقليدي ومفاعل العمليات المتعاقبه كمعالجة ثانوية وكذلك معرفة مدى قدرتها على طرح مياه مجاري معالجة مطابقة للمواصفات العراقية. لقد تم دراسة قابلية المحطة على ازالة او تقليل ثلاث مؤشرات للتلوث (BOD5, COD and TSS), و قد كانت النتائج غير مرضية للعديد من الاسباب اهمها كانت مشاكل تشغيلية سببت جميعا ضعف الاداء بصورة عامة.

Listing 1 - 5 of 5
Sort by
Narrow your search

Resource type

article (5)


Language

English (5)


Year
From To Submit

2018 (2)

2017 (1)

2015 (1)

2008 (1)