research centers


Search results: Found 211

Listing 1 - 10 of 211 << page
of 22
>>
Sort by

Article
Biotreatment of Al-Yarmook Hospital Wastewater Using Packed Bed Bioreactor
المعالجة الحيوية لمياه صرف مستشفى اليرموك باستخدام مفاعل حيوي نوع العمود المحشو

Author: Mohammed B. Abdul Kareem
Journal: Iraqi Journal of Biotechnology المجلة العراقية للتقانات الحياتية ISSN: 18154794 Year: 2013 Volume: 12 Issue: 1 Pages: 91-100
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

Biotreatment systems of wastewater for hospitals are a challenge for environmental engineers. In this study, a pilot- scale system of aerobic fixed film packed bed was constructed for wastewater treatment of Al-Yarmok hospital which located in Baghdad. The aim of this study was to test the performance of fixed film packed-bed for elimination of the organic compounds from wastewater under aerobic condition. The parameters studied were: inoculums concentration, circulation rate, packing type and temperature. The results showed that the system efficiently removed about 85% of the chemical oxygen demand (COD) and 82% of Biological oxygen demand (BOD), while percent reduction in turbidity was about 93% and reduction in nitrate concentration was about 85%. It was found that temperature of 35oC and circulation rate of 16 L/min and inoculums concentration of 5% gave the best results for biotreatment of wastewater.

تعتبر عمليات معالجة مياه الصرف الخاصة بالمستشفيات من الامور المهمة بالنسبة لمهندسي البيئة. في هذا البحث تم نصب عمود محشو لغرض اجراء دراسة تجريبية لمعالجة مياه الصرف الخارجة من مستشفى اليرموك في بغداد وتحت ظروف هوائية. ان المتغيرات التي تمت دراستها تتضمن تركيز اللقاح ,معدل تدوير المياه الملوثة خلال العمود ,نوع الحشوة المستخدمة ودرجة الحرارة. بينت النتائج ان الجهاز يزيل تقريبا 85% من الاوكسجين المطلوب كيمياويا ((COD وكذلك 82% من الاوكسجين المطلوب حيويا (BOD). بينما كانت نسبة ازالة العكورة 93% ونسبة ازالة ايونات النتروجين بحدود 85%. اوضحت النتائج العملية ان درجة حرارة 35 مْ ومعدل تدوير 16 لتر / دقيقة وتركيز لقاح 5% تعطي افضل النتائج لمعالجة مياه الصرف. يمتاز العمود المحشو المستخدم بسهولة نصبه وصيانته فضلا عن انه ذو كفاءة عالية في عملية المعالجة.


Article
Lead bioremoval by Bacillus spp. Isolated from industrial wastewater
الازالة الحياتية للرصاص بوساطة Bacillus spp. المعزولة من مياه الفضلة الصناعية

Authors: Harith J.Fahad Al-Mathkhury حارث جبار فهد المذخوري --- Fa’iza Kadhim Omran فائزة كاظم عمران
Journal: Baghdad Science Journal مجلة بغداد للعلوم ISSN: 20788665 24117986 Year: 2011 Volume: 8 Issue: 1عدد خاص بمؤتمر علوم الحياة Pages: 539-546
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

Four samples were collected from the wastewater of State Battery Manufacturing Company (SBMC); Babylon 2 factory in AL-Waziriya district, as triplicates. Physical and chemical measurements were carried out such as temperature, pH, Lead concentrations and their ranges were: (19.5-34.5) °C, (6.1-6.4) and (4.5-6.5) mg/L, respectively. Six dominant Bacillus spp. isolates were isolated from these samples; namely, Bacillus subtilis N1, Bacillus subtilis N2, Bacillus subtilis N3, Bacillus cereus N4, Bacillus cereus N5 , Bacillus cereus N6. These isolates were capable of removing Lead from aqueous solutions in a capacity reached 27.6 ± 1.4, 10.1 ± 1.7, 74.5 ± 0.7, 8.93 ± 2.8, 8.1 ± 3.5, 1.6± 0.7 mg/L, respectively. Whereas cell walls, extracted from the same isolates, were able to remove Pb with high efficiency reached 77.7 ± 0.3, 18.6 ± 1.2, 9.5 ± 0.7, 42.4 ± 6.3, 9.9 ± 0.9, 6.7 ± 2.1 mg/L, respectively. This study showed that there is high variation (P<0.05) in the ability of the isolated bacteria for lead biosorption. However, Bacillus subtilis N3 were the most efficient (P<0.05) in uptaking the lead from its aqueous solutions in average of (74.5 ± 0.7) mg/L compared to other bacterial species. FTIR spectrum illustrated that hydroxyl groups, carboxyl, amide, and carbonyl are the major sites for Pb binding. Cell walls of B. subtilis were able to remove almost all Pb ions from the wastewater sample (4.5 mg/L) taken from the wastewater treatment unit in the State Battery Manufacturing Company.

جمعت اربع نماذج من مياه الفضلة الصناعية للشركة العامة للبطاريات (معمل بابل-2 ) في الوزيرية وبواقع 3 مكررات .اجريت الفحوصات الفيزياوية والكيمياوية لتحديد الظروف البيئية , اذ كانت مديات درجات الحرارة , والاس الهيدروجيني, وتركيز الرصاص هي (19.5- 34.5 ) م°,(6.1-6.4 ), (4.5 -6.5 ) ملغم/لتر على التوالي . تم عزل وتشخيص ست انواع تابعة لجنس Bacillus من هذه العينات , Bacillus subtilis N1, B. subtilis N2,, B. subtilis N3. B.cereus N4 , , B. cereus N5 cereus N6.B. أختبرت العزلات في قابليتها على ازالة الرصاص من المحاليل المائية وقد كانت سعة الازالة, 27.6 ± 1.4, 10.1 ± 1.7, 1.6± 0.7 , 8.1 ± 3.5 , 8.93±2.8 , 74.5 ± 0.7 ملغم/لتر على التوالي . في حين كانت الجدران الخلوية المستخلص من العزلات البكتيرية نفسها, تبين ان لها كفاءة عالية في أزالة الرصاص وكانت معدلات الأزالة كما يلي 77.7 ± 0.3, 18.6 ± 1.2, 9.5 ± 0.7, 42.4 ± 6.3, , 6.7 ± 2.1 , 9.9 ± 0.9, ملغم/لتر على التوالي . أظهرت الدراسة تغايراً كبيرا(P>0.05 )ً في قابلية العزلات البكتيرية في أمتزاز الرصاص. اذ كانت العزلة B. subtilis N3 هي الأكفأ في أمتزاز الرصاص من المحاليل المائية بمعدل 77.7 ± 0.3 ملغم/لتر عند مقارنتها مع بقية الانواع البكتيرية المعزولة . من نتائج تحليل الاشعة تحت الحمراء ظهر ان المجاميع الكيمائية: الهيدروكسيل , الكاربونيل والأمايد والكاربوكسيل هي المسؤولة عن ربط الرصاص .لوحظ ان الجدار الخلوي للعزلة البكتيرية N1 B. subtilis تمكنت من أزالة ايونات الرصاص جميعها من العينة المأخوذة من وحدة معالجة مياه الفضلة الصناعية للشركة العامة لصناعة البطاريات والتي وجد تركيز الرصاص فيها 4.5 ملغم/لتر

Keywords

Lead --- bioremoval --- Bacillus --- wastewater


Article
Electrocoagulation of phenol for wastewater treatment

Author: Ahmed A-Mohammed
Journal: Iraqi Journal of Chemical and Petroleum Engineering المجلة العراقية للهندسة الكيمياوية وهندسة النفط ISSN: 19974884/26180707 Year: 2008 Volume: 9 Issue: 3 Pages: 45-49
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

Electrocoagulation is an electrochemical process of treating polluted water where sacrificial anode corrodes to produce active coagulant (usually aluminum or iron cations) into solution. Accompanying electrolytic reactions evolve gas (usually as hydrogen bubbles). The present study investigates the removal of phenol from water by this method. A glass tank with 1 liter volume and two electrodes were used to perform the experiments. The electrode connected to a D.C. power supply. The effect of various factors on the removal of phenol (initial phenol concentration, electrode size, electrodes gab, current density, pH and treatment time) were studied. The results indicated that the removal efficiency decreased as initial phenol concentration increased, the highest removal obtained at pH in the range (6-8), the removal enhanced with increasing electrode size and decreasing the gab between the electrodes. The optimum current density obtained at 221 A/m2.


Article
REUSE OF DOMESTIC WASTEWATER FOR IRRIGATION: CONCEPTUAL AND BASIC DESIGN ELEMENTS

Author: Abdul-Fattah Mohamed Ali
Journal: Iraqi Journal of Chemical and Petroleum Engineering المجلة العراقية للهندسة الكيمياوية وهندسة النفط ISSN: 19974884/26180707 Year: 2011 Volume: 12 Issue: 1 Pages: 43 -52
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

In Iraq, water shortages and drought, especially during the hot summer months, necessitates that municipal authorities adopt water reuse projects like reusing treated domestic wastewater for crop irrigation. This work gives the conceptual and basic design elements for the necessary steps of filtration, UV irradiation and chlorination to make such a wastewater fit for agricultural use. A typical rural community of 50,000 people is considered as an example case for which functionality and relative simplicity of the proposed designs are prime factors. The objectives are 1) to show what is required and 2) that the presented information may be utilized to embark on the following phases of detailed design and execution of such projects.

ان شحة المياه والجفاف الذي يشهدهُ العراق , خصوصاً اثناء اشهر الصيف الحارة, تجعل من الضروري على السلطات البلدية اعتماد مشاريع اعادة استعمال المياه المصرفة المعالجة كمياه الصرف الصحي . يبين هذا العمل مفاهيم وعناصر التصميم الاساس لمراحل جعل هكذا مياه صالحة لسقي المزروعات. حيث تشتمل هذه المراحل على الترشيح والمعالجة بالاشعة فوق البنفسجية ومن ثم الكلورة. تم اعتماد تجمع سكاني ريفي عدد نفوسه 50000 كمثال لتوضيح التصاميم المقترحة المتسمة بالبساطة النسبية والفاعلية. يهدف العمل الى 1) ايضاح المتطلبات و 2) الأفادة من المعلومات المقدمة للشروع بطوري التصاميم التفصيلية والتنفيذ لهذه المشاريع.


Article
Zinc Removal from Industrial Wastewater by Electro-Coagulation Process

Authors: Nawras S. Sabeeh --- Ibtehal K. Shakir
Journal: Iraqi Journal of Chemical and Petroleum Engineering المجلة العراقية للهندسة الكيمياوية وهندسة النفط ISSN: 19974884/26180707 Year: 2007 Volume: 8 Issue: 2 Pages: 43-46
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

Electro coagulation treatment was used for zinc removal from electroplating -wastewater of the State Company for Electrical Industries, This wastewater, here consists zinc ions with maximum concentration in solution of 90 ppm.The parameters that influenced the wastewater treatment are: current density in the range 1—1.4 mA/cm, pH in the range 5-10, temperature in the range 25—45°C and time in the range /0—180 minute.The research is a laboratory experimental type using batch system for electrical process with direct current. The cell comprised of aluminum electrode as anode and stainless steel electrode as cathode. Thirty experiments and one hundred fifty sample lab tests were carried out in this research to study the effect of the mentioned paramet cr5 on the efficiency of the removal process.Experimental work of this research proved a higher efficiency about 95 % removal of zinc from wastewater at 1.4 mA! cm in alkaline media atpH equal and Mmperature 45°C.


Article
Removal of lead from simulated wastewater by electrocoagulation method

Authors: Muhanned Dhia Fadhil Al-Mureeb --- Ahmed A.Mohammed
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2010 Volume: 16 Issue: 4 Pages: 5811 -5821
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

The separation of lead ions from wastewater was carried out in an electrocoagulation cell which has a set of electrodes, aluminum anode and stainless steel cathode. The effect of several working parameters such as pH, current density, initial lead concentration, electrodes surface area, gap between electrodes and sodium chloride concentration on the performance of electrocoagulation cell were examined. From the experiments found that the higher removal efficiency achieved at pH 9, with increasing current density and decreasing gap between electrodes the removal efficiency enhanced and the treatment time decreased. Using a flowrate of 0.025 l/min after (7min) electrolysis, the Pb(II) concentration decay from (250mg/l) to only (2.5mg/l) corresponding to a 99% removal efficiency.

آيونات ألرصاص في المياه الصناعية الملوثة فصلت داخل خلية التختير الكهروكيمياوي التي تحتوي على قطب انود من الألمنيوم وقطب كاثود من الحديد المقاوم للصدأ. عدة متغيرات والتي لها تأثير على كفاءة ألإزالة مثل الدالة الحامضية, كثافة التيار, تركيز الرصاص ألأولي, درجة الحرارة, تركيز كلوريد الصوديوم, المسافة بين ألأقطاب, المساحة السطحية للأقطاب ونوعيتها تم دراستها. من التجارب وجد ان أعلى كفاءة ازالة تتجقق عندما تكون الدالة الحامضية 9 , وبزيادة كثافة التيار التيار وتقليل المسافة بين ألأفطاب تتحسن كفاءة ألأزالة ويقل وقت المعالجة. كذلك وجد ان كفاءة ألأزالة تتحسن عند تقليل معدل الجريان.


Article
Some Negative Effects of Wastewater on Clayey Soil
بعض التأثیرات السلبیة لمیاه الصرف الصحي على التربة الطینیة

Authors: غیداء یاسین رشید --- شیماء طارق كاظم
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2010 Volume: 28 Issue: 22 Pages: 1142-1155
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

This study deals with the effect of wastewater on some physical, chemical andconsolidation properties of clayey soil and investigates the effect of wastewater flowbeneath buildings’ and structures’ foundations due to; breaking of wastewater pipes,the permeation of sewage water in to the soil, or its flow on the land that hasn’t beenconstructed yet.Soil samples have been taken from the University of Technology site at a depth (1–1.5) m and the preparation of samples were in two manners: the first by takingundisturbed samples which have been flooded with wastewater that allowed topermeation and flow through soil sample, the second, by taking disturbed samplessaturated with wastewater to ferment.The soil that used in this study was silty clay with low plasticity (CL-ML) and theresult of this study which lasted for (10) months showed an increase in the chlorides and sulphates ions during the first months and then decreased, it has been noticed anincrease in the concentration of carbonates ions along the period of study and anincrease in organic matter due to wastewater nature.The results of soil- wastewater interaction showed an increase in liquid limit, plasticlimit and plasticity index for both undisturbed and disturbed samples and the specificgravity of soil decreased due to wastewater chemical contents. The void ratio has beenincreased and preconsolidation pressure decreased which may be attributed to thedissolution of soluble salts and the influence of carbonate bonding that may be brokenwhen subjected to load. Also, the results showed an increment in the ability of soil tobe compressed when soil compression index (Cc) increased and soil swelling index (Cr)increased, too.

تتضمن ھذه الدراسة تأثیر میاه الصرف الصحي على بعض الخواص الفیزیائیة و الكیمیائیةللتربة الطینیة و معرفة مقدار تأثیرھا على خواص الانضمام و على اسس المنشأت و المباني عندماتعاني تسرب للمیاه تحتھا نتیجة لتكسر انابیب الصرف الصحي أو نتیجة لتغلغل المیاه الاسنة في التربةأو لانسیاب المیاه على الاراضي المتروكة والتي لم یباشر في بنائھا.1.5 ) م وتمت النمذجة بأسلوبین الاول - تم أخذ نماذج التربة من موقع في الجامعة التكنولوجیة وبعمق ( 1بأخذ عینات غیر مشوشة تم غمرھا بمیاه الصرف الصحي و سمح لتلك المیاه بالتغلغل و الجریان خلالنموذج التربة، الثاني أخذ عینات مشوشة شبعت بمیاه الصرف الصحي لتخمیرھا.و قد اظھرت نتیجة ھذه (CL-ML) توصف تربة ھذه الدراسة بأنھا طینیة غرینیة ذات لدونة واطئةالدراسة التي دامت ( 10 ) أشھر زیادة ایوني الكلوریدات و الكبریتات خلال الاشھر الاولى ثم انخفاضھافي الاشھر الاخیرة ، و لوحظ زیادة في تركیز ایون الكاربونات على طول فترة الدراسة و زیادةالمحتوى العضوي كنتیجة متوقعة لطبیعة میاه المخلفات.أظھرت نتائج معاملة التربة بمیاه الصرف الصحي الى زیادة في حد السیولة ، اللدونة ومؤشر اللدونة وللنموذجین المشوش و غیر المشوش و لوحظ وجود نقصان في الوزن النوعي للتربة مع الزمن نتیجةلمحتویات میاه الصرف الصحي الكیمیائیة. و لوحظ زیادة في نسبة الفراغات وانخفاض في ضغطالانضمام المسبق ناتج عن ذوبان الاملاح الذائبة و تكسر الاواصر الفیزوكیمیائیة عند تسلیط الضغطعلى محتوى الكاربونات في التربة. كما تبین من خلال النتائج زیادة في انضغاط التربة حیث ازداد.(Cr) و ارتفاع في قیم مؤشر الانتفاخ (Cc) مؤشر الانضغاط


Article
Physico-chemical and Biological Variables of Hospitals Wastewater in Erbil City
المتغيرات الفيزيوكيميائية والبايولوجية لمياه الصرف الصحي لمستشفيات في مدينة اربيل

Loading...
Loading...
Abstract

Three hospitals were chosen(Maternity hospital, Raperin hospital and Rhizgari hospital) for the present survey within Erbil city. Water samples were collected at regular monthly interval periods beginning in January 2012 to December 2012. pH of all the studied sites were found to be up 7. Electrical conductivity ranged from (1318-1790 µs.cm-1 in Maternity Hospital, 1770-2232 µs.cm-1 in Raperin Hospital, 1010-1615 µs.cm-1 in Rhizgari Hospital). BOD5 and COD values ranged from 22- 80 mg.L1 and 280- 1410 mg.L-1 respectively, this indicated a high pollution situation in the studied sites in respect to organic matter content. The quantitative analysis of counted microorganisms was more than that describe by WHO guidelines standard.

في هذه الدراسة اختيرت عينات المياه العادمة من ثلاث مستشفيات في مدينة اربيل هي مستشفى رزكاري ومستشفى رابرين ومستشفى الولادة, حيث جمعت العينات في فترات فاصلة منتظمة شهريا ابتداء من كانون الثاني 2012 إلى كانون الاول 2012. بينت نتائج الدراسة ان المياه كانت تميل الى القاعدية وكان الاس الهيدروجيني عموما اعلى من 7, تراوحت قيم التوصيل الكهربائي بين1318-1790 مايكروسيمنز.سنتيمتر-1 في مستشفى الولادة، وبين 1770-2232 مايكروسيمنز.سنتيمتر-1 في مستشفى رابرين، وبين 1010-1615 مايكروسيمنز.سنتيمتر-1 في مستشفى رزكاري. تراوحت قيم كل من المتطلب الحيوي للاوكسجين والمتطلب الكيمياوي للاوكسجين 22 -80 ملغم/لتر-1 و280-1410 ملغم/لتر-1 على التتالي نستدل مما سبق على وجود تراكيز عالية من المواد العضوية في مياه الفضلة لتلك المستشفيات. وقد تجاوزت نتائج التحليل الكمي للكائنات الدقيقة الحدود العليا المسموح بها من قبل منظمة الصحة العالمية.

Keywords

hospital wastewater --- BOD --- COD.


Article
Thermal Osmosis of Mixtures of Water and Organic Compounds through Different Membranes

Authors: Ahmed Faiq Al-Alawy --- Ramy Mohamed Al – Alawy
Journal: Iraqi Journal of Chemical and Petroleum Engineering المجلة العراقية للهندسة الكيمياوية وهندسة النفط ISSN: 19974884/26180707 Year: 2016 Volume: 17 Issue: 2 Pages: 53-68
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

The present work aimed to study the efficiency of thermal osmosis process for recovery of water from organic wastewater solution and study the factors affecting the performance of the osmosis cell. The driving force in the thermo osmosis cell is provided by a difference in temperature across the membrane sides between the draw and feed solution. In this research used a cellulose triacetate (CTA), as flat sheet membranes for treatment of organic wastewater under orientation membrane of active layer facing feed solution (FS) and draw solution (DS) is placed against the support layer. The organic materials were phenol, toluene, xylene and BTX (benzene, toluene, and xylene) used as feed solution. The osmotic agent in draw solution was sodium chloride salt. The membranes have high rejection percentage for NaCl and organic materials. In this research, the operating conditions that have been studied are: temperature of draw and feed solution (18 – 45 °C) and the operating time of process was (0 – 3) hours. It was found that water flux in thermal osmosis process increases with increasing temperature of draw and feed solution ( by average ratio 1:2), and decreases with increasing operating time.


Article
Electroflotocoagulation of Emulsified Cooling Oils as a Method of Pollution Control

Authors: Thamer J. Mohammed --- Dhia AL-DeenMohammed --- Abbas A.K.AL-Rikaby
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2016 Volume: 34 Issue: 8 Part (A) Engineering Pages: 1636-1650
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

This research includes the removal of pollution produced from used coolant emulsion oils especially soluble oil (7201). In many types of liquid effluents, oil – water emulsions can be among the most vexing to treat, even through such streams may contain only very small quantity of oil. Untraditional oil removal operation (electroflotocoagulation) is used in this research, which consist of glass cell 102 cm in height. A sacrificial Aluminum Anode is placed on a perforated glass disc at a distance 24-cm from the bottom. Above it is placed the upper electrode, Aluminum cathode is fixed on a movable glass tube. Product water was fed into settling vessels from the outlet arm 17 cm above the glass disc. Oily flocs and aluminum hydroxide were removed by a second side arm 45.5 cm above the product water arm. Sets of experiments were carried out to find the efficiency of electroflotocoagulation to remove the concentrate soluble oil (7201) from water. Multivariables were studied such as: applied potential, space between the two electrodes, settling time and initial soluble oil (7201) concentration. These variables have effect on the soluble oil (7201) percentage removal. The experimental results were represented in two mathematical em-pirical correlations and three dimensional graphs which describe the soluble oil (7201) removal efficiency as a function of current, settling time and in the second, initial soluble oil (7201) concentration respectively.

Listing 1 - 10 of 211 << page
of 22
>>
Sort by
Narrow your search

Resource type

article (211)


Language

English (156)

Arabic (34)

Arabic and English (18)


Year
From To Submit

2019 (6)

2018 (18)

2017 (31)

2016 (27)

2015 (15)

More...