research centers


Search results: Found 7

Listing 1 - 7 of 7
Sort by

Article
Simultaneous determination of tryptophan and tyrosine in binary mixture by zero-crossing second derivative spectrophotometry.
التقدير الآني للتربتوفان والتايروسين في مزيجهما باستخدام المشتقة الطيفية الثانية

Author: Riyadh Mohammed Jihad لياض محمد جهاد
Journal: Journal of university of Anbar for Pure science مجلة جامعة الانبار للعلوم الصرفة ISSN: ISSN: 19918941 Year: 2010 Volume: 4 Issue: 1 Pages: 35-39
Publisher: University of Anbar جامعة الانبار

Loading...
Loading...
Abstract

Rapid and accurate binary mixture resolution of tryptophan and tyrosine was performed. Differential-derivative spectrophotometry with a zero-crossing measurement technique was used for the quantitative determination of tryptophan and tyrosine in laboratory-prepared mixtures. Neither sample pretreatment nor separation were required. Linear calibration graphs of differential second derivative values were (at 222.4 and 217.9 nm for tryptophan and tyrosine , respectively) versus concentration in the ranges 0.1–20.0 and 1.0– 50.0 µg ml_1, and the linearity was satisfactory (r = 0.9987 and r = 0.9997), for tryptophan and tyrosine , respectively) were obtained .The relative standard deviations were found to be less than 1.03%, indicating reasonable repeatibility of method.The results obtained by the proposed method has been statistically compared by means of Student t-test and by the variance ratio F-test where shows a good agreement .

تم استخدام طریقة دقیقة وسریعة لغرض فصل مركبي التربتوفان و التایروسین في المزیج الثنائي لهما . حیث تم أستخدامتقنیة المشتقة الطیفیة بالقیاس عند نقطة تقاطع الصفر في التقدیر الكمي لمركبي التربتوفان و التایروسین في المزیج المحضر مختبریا .اذ لم یلزم الأمر أي معالجة للنموذج المستخدم او أیة عملیة فصل مسبقة . كانت منحنیات المعایرة الخطیة لقیم المشتقة الطیفیة الثانیة٥٠.٠- ٢٠.٠ مایكروغ ا رم/مللتر ومن ١.٠ - عند الأطوال الموجیة ٢٢٢.٤ نانومیتر و ٢١٧.٩ نانومیتر ذات مدى خطي یمتد من ٠.١مایكروغ ا رم/مللتر ومعامل الأرتباط یساوي ٠.٩٩٨٧ و ٠.٩٩٩٧ للتربتوفان و التایروسین على التوالي. كما وجد أن الأنح ا رفات القیاسیةالنسبیة أقل من ١.٠٣ % مما یشیر الى قابلیة معقولة على التك ا رر في هذه الطریقة. النتائج المستحصلة باستخدام هذه الطریقة تم مقارنتهاحیث تبین موافقة جیدة. ( f ) ونسبة التباین ( t ) احصائیا بواسطة اختبار الطالب


Article
SPECTROPHOTOMETRIC DETERMINATION OF BINARY MIXTURE OFSOME آ-LACTAM ANTIBIOTICS

Authors: Shahbaz A. Maki --- Nabil S. Nassory --- Khaleda H. Al-Saidi
Journal: Al-Nahrain Journal of Science مجلة النهرين للعلوم ISSN: (print)26635453,(online)26635461 Year: 2009 Volume: 12 Issue: 3 Pages: 33-44
Publisher: Al-Nahrain University جامعة النهرين

Loading...
Loading...
Abstract

Derivative spectrophotometric techniques (first, second, third and fourth derivative) were
developed for the determination of four â-lactam antibiotic binary mixtures; in combinations
containing these compounds. The simultaneous determination of these compounds was
accomplished by derivative (1D, 2D, 3D and 4D) spectrophotometric technique and applying zerocrossing
technique amoxiclline trihydrate with cephalexin monohydrate (mix I) using 1D spectrum
zero crossing at valley 238.2 nm, and 2D spectrum at valley 263.8 nm, respectively, amoxiclline
trihydrate with cloxacillin sodium (mix II) using 2D at valley 281 and 4D at valley 230.6,
respectively, cephalexin monhydrate with cloxacillin sodium (mix III) using 1D spectrum zero
crossing at 272 nm and 2D spectrum at 253.2 nm, respectively and ampicillin trihydrate with
cloxacillin sodium (mix IV) using 1D at 282nm and 2D at 271.6 nm, respectively. From this
studying it was noticed that in all the applications of the previous methods the correlation
coefficient of calibration curves not less than 0.999 and the relative standard deviation not exceed to
0.214. The four described procedures were successfully applied to the determination of these
compounds in synthetic mixtures and in preparations with high percentage of recovery, accuracy
and precision .The procedures do not require any separation step.


Article
Spectrophotometric Determination of Promethazine Hydrochloride and Paracetamol in Pharmaceutical Tablets

Authors: Khaleda H. Al-Saidi --- Rana A, Hammza
Journal: Al-Nahrain Journal of Science مجلة النهرين للعلوم ISSN: (print)26635453,(online)26635461 Year: 2014 Volume: 17 Issue: 1 Pages: 14-23
Publisher: Al-Nahrain University جامعة النهرين

Loading...
Loading...
Abstract

Spectrophotometric techniques were developed for the determination of single and binarymixture Promethazine hydrochloride (PMH) and Paracetamol (PCM). Normal and first derivative (1D) used for single drug at λ 249.5 and 243.0 for PMH and 243.5 and 225 for PCM. The simultaneous determination of binary mixture (PMH) and (PCM) were accomplished by first derivative (1D) and second derivative (2D) spectrophotometric technique with applying zero-crossingat valley (V=216.5) and Peak (P=258.8)nm for (PMH) and (V=274.0 and P=299.2 nm for PCM).The correlation coefficient for calibration curves not less than 0.999 and the relative standard deviation not exceed to 0.214. The recovery of individual constituents under establishedconditions inthe ranges from 97.00% to 101.97 %. Linearity is maintained within a wide concentrationrange from 4.00-30.00mg/L for PMH and PCM. Standard addition method used forpharmaceutical tablets. A good accuracy and precision of simultaneous determination of (PCM), and (PMH) were confirmed by statistical analysis. The proposed procedures were successfully applied to the determination of these compounds in different ratio by synthetic mixtures and pharmaceutical tablets without requiring any separation step.

استخدمت تقنية الاطياف في تعيين كل من هيدروكلوريد البروميثازين والباراستيامول للادوية المنفردة والمزيج الثنائي، وباستخدام الطيف العادي وطيف المشتقة الاولى لتعيين هيدروكلوريد البروميثازين المنفرد في الاطوال الموجية 249.5 و 243.0 نم على التوالي ولتعين الباراستيامول في 243.5 و225.0 نم على التوالي اما المزيج الثنائي فقد استخدمت طريقة التقاطع الصفري لاطياف المشتقة الاولى والثانية لتعيين البروميثازين وفي الاطوال الموجية 216.5 و258.8 نم وللمشتقة الاولى لتعيين الباراستيامول في الاطوال الموجية في 274.0 و 299.2 نم. كان معامل الارتباط لمنحنيات المعايرة لايقل عن 0.9990 ومعدل الانحراف المعياري لايزيد عن 0.214 وكذلك نسبة الاسترداد لكل من هيدروكلوريد البروميثازين الباراستيامول بين 97.00% -101.97%، وان الخطية للمحاليل بين 2.00- 30.00 ملغم/ لتر ان التحليل الاحصائي اثبت الدقة العالية للطريقة وقد طبقت هذه الطريقة بنجاح لنماذج محضرة وبنسب مختلفة، وكذلك على النماذج الدوائية مثل اقراص الكولدين والباراسيتول.97.00% -101.97%، وان الخطية للمحاليل بين 2.00- 30.00 ملغم/ لتر ان التحليل الاحصائي اثبت الدقة العالية للطريقة وقد طبقت هذه الطريقة بنجاح لنماذج محضرة وبنسب مختلفة، وكذلك على النماذج الدوائية مثل اقراص الكولدين والباراسيتول.


Article
Simultaneous Determination of Paracetamol and Hyoscine-N- Butyl Bromide in Binary Mixture Using Derivative Spectrophotometry and Their Application for Pharmaceutical Samples

Authors: Marwa S. Yonis --- Khaleda H. Al-Saidi
Journal: Al-Nahrain Journal of Science مجلة النهرين للعلوم ISSN: (print)26635453,(online)26635461 Year: 2016 Volume: 19 Issue: 1 Pages: 56-68
Publisher: Al-Nahrain University جامعة النهرين

Loading...
Loading...
Abstract

Derivative spectrophotometric (first, second, third and fourth derivative) were used for the determination of paracetamol )PAR) and hyoscine n-butyl bromide (HYO) the binary mixture by applying zero-crossing technique for pure synthetic mixture. Also simultaneous determination of PAR and HYO in (SPAZMOTEK PLUS) tablets was applied. PAR was determined by using 1D and 2D methods at 297.4 and 303.5 nm (zero crossing point of HYO) with linear concentration ranges 2-30 μg.mL-1, with correlation coefficient r (0.9998, 0.9987), LOD (0.081, 0.250 μg mL-1), relative error (0.68, 0.22) and RSD% (0.107, 0.400), respectively. HYO was determined by using 1D method at 215.9 nm (zero crossing point of PAR) with concentration range 2-25 μg mL-1, with correlation coefficient 0.9997 and LOD 0.091μg mL-1, relative error 1.20 and RSD% 0.342. No interference found between both determined and those of matrices. A good accuracy and precision of simultaneous determination of PAR, and HYO were confirmed by statistical analysis. The percentage recovery of the individual drugs under the established conditions is ranged from 95.07% to 100.93%, the proposed procedures were successfully applied to the determination of these compounds in different ratio by synthetic mixtures and pharmaceutical tablets without requiring any separation step.

تم استخدام المشتقاث الطيفية (الاولى, الثانية, الثالثة والرابعة) في تعيين الباراسيتامول والهايوسين بيوتل برومايد في مزيج ثنائي وبتقنية التقاطع الصفري للنماذج النقية والمستحضر الصيدلاني. تم تقدير الباراسيتامول و الهايوسين في مزيجهما باستخدام المشتقة الاولى والثالثة في (297.4 نانومتر) و (303.5 نانومتر) وكان مدى التراكيز الخطية (2-30 مايكـــروغــــرام/مـــــل) بمعامل ارتباط r (0.9998) و (0.9987) وحـــــــــد الكشــــــــــــــف (0.081 و 0.250 مايكروغرام/مل) والخطأ النسبي (0.68, 0.22) وانحراف معياري نسبي (0.107, 0.400) للباراسيتامول على التوالي. اما الهايوسين فتم تقديره باستخدام المشتقة الاولى في (215.9 نانومتر) ومدى التراكيز الخطية (2-25 مايكروغرام/مل) بمعامل ارتباط r (0.9997) وحد الكشف (0.091 مايكروغرام/مل) وكان الخطأ النسبي (1.20) بمعامــــل الانحراف النسبــــي (0.342) علــــى التوالـــــــي وتـــــم تطبيقــــــــــــه علـــــــــــــــى دواء (SPAZMOTEK PLUS-500PAR,10HYO mg) بدون تداخل بين مكونات الادوية. النتائج الاحصائية تساند دقة وصخة الطرق المستعملة حيث بلغت نسبة الاسترجاع بين (95.07%-100.93%). هذه الطريقة سهلة لا تحتاج الى فصل او اي معاملة.


Article
Gender Classification based on Audio Features
تصنيف نوع الجنس استناداً إلى مميزات الصوت

Authors: .Nidaa F. Hassan نداء فليح حسن --- Sarah Qusay Selah Alden ساره قصي صلاح الدين
Journal: Journal of Al-Ma'moon College مجلة كلية المأمون ISSN: 19924453 Year: 2018 Issue: 31 Pages: 196-213
Publisher: AlMamon University College كلية المامون الجامعة

Loading...
Loading...
Abstract

Gender audio classification is considered one of the most significant methods in audio processing. In this paper, an algorithm involving audio features (mean, standard deviation, zero crossing, Amplitude) and Support Vector Machine (SVM) is presented to perform speaker gender recognition. For each audio, the highlights vector is utilized as an info vector in the SVM algorithm. An example of 2270 audio, include 1132 female audio with 1138 male audio is analyzed based on this algorithm. With only the four features, the average prediction error is 5%.

إن نوع الجنس بالاعتماد على الصوت يعد في الاونه الاخير من أهم العمليات في معالجة الصوت. في هذا البحث ,تم تقديم خوارزمية تنطوي على مميزات الصوت (الوسط الحسابي ، الانحراف المعياري، عبور الصفر و السعة) و الة دعم التصنيفSVM لتنفيذ التعرف على جنس المتحدث.لكل إشارة، يتم استخدام قيم المميزات كمتجه إدخال في خوارزمية آلة دعم التصنيف. تم تحليل العينات الصوتيه استنادا إلى هذه الخوارزمية والتي يبلغ عددها 2270 إشارة، تحتوي على 1132 صوت أنثى و 1138 صوت ذكر،وباستخدام المميزات الأربع فقط , قيمه متوسط خطأ التنبؤ قد بلغ 5٪.


Article
Using Genetic Algorithm To Determine The Architecture for Adaptive Neural Network To Recognize Some Of Arabic Phonemes
استخدام الخوارزمية الجينية لتحديد معمارية شبكة انسياب الخطأ خلفا المعدلة بمعامل تعلم متكيف لتمييز بعض الفونيمات العربية

Author: Saba abdul w. Alabodey صبا عبد الواحد صدام
Journal: Journal of Basrah Researches (Sciences) مجلة ابحاث البصرة ( العلميات) ISSN: 18172695 Year: 2008 Volume: 34 Issue: 2B Pages: 7-14
Publisher: Basrah University جامعة البصرة

Loading...
Loading...
Abstract

The aim of this paper is to determine the best architecture of neural network by using the genetic algorithm to recognize some of Arabic phonetics.In this paper the recorded speech signal has been processed through two stages. The first stage contains the required calculations of the best locations, while in the second stage the frequencies values and different manipulation have been calculated such as sorting, scaling and selecting three frequencies value to represent each phoneme.In the third stage the genetic algorithm will be used to determine the architecture of neural network to recognize the Arabic phonemes. The sound signals are recorded by using sound forge 5 , and work done by using Matlab 6.5 and turbopascal7 . As a result the recognition percentage is more than 80% .

يهدف العمل في هذا البحث الى تحديد افضل معمارية شبكة عصبية باستخدام الخوارزمية الجينية لتمييز بعض الفونيمات العربية . تضمن العمل ثلاث مراحل اساسية , شملت الاولى والثانية معالجة الاشارات الصوتية المسجلة من خلال اجراء الحسابات اللازمة لتحديد افضل المواقع التي يمكن اختيارها لتقطيع السلسلة الطويلة من العينات واستخلاص قيم طيف الترددات التي تحتويها الاشارة الصوتية , وضمت ايضا كل المعالجات التي نفذت على قيم طيف الترددات الناتج من استخدام طريقة فورير من اختيار وترتيب وتقييس القيم المميزة لكل اطار Frame صوتي مستخدم .اما المرحلة الثالثة فقد تضمنت استخدام الشبكة العصبية ذات الانسياب الخلفي المعدلة بمعامل تعلم متكيف والمحددة معماريتها باستخدام الخوارزمية الجينية كمميز لتمييز مجموعة الانماط التي تمثل كل منها صفة مميزة من صفات الفونيمات العربية المتكونة منها الاشارة الصوتية المسجلة .سجلت الاشارات الصوتية باستخدام برنامج Sound forge 5 وطبق العمل بتصميم وتطبيق برامج بواسطة كل من Matlab 6.5 و turbo pascal 7 وكانت نسبة دقة التمييز التي تم الحصول عليها هي 80% .


Article
Recognize some of Arabic phonemes by using Mamdani NeuroFuzzy Network
هيبرعلا تامينوفلا ضعب زييمت ادمم( ةببضملا ةيبصعلا ةكبشلا مادختساب )ين

Author: Saba Abdul-Wahed S. مادص دحاولا دبع ابص . م
Journal: Journal of Al-Qadisiyah for Computer Science and Mathematics مجلة القادسية لعلوم الحاسوب والرياضيات ISSN: 20740204 / 25213504 Year: 2015 Volume: 7 Issue: 1 Pages: 131-145
Publisher: Al-Qadisiyah University جامعة القادسية

Loading...
Loading...
Abstract

Modified mamdani neurofuzzy network scheme has been proposed and presented in this paper to recognize some of Arabic phonemes. The number of connecting is reduced to be equal to the number of member ship function plus one. to training this network ,we used some of sound segments which contain from two or three phonemes and recorded from more than one person in different age and both sexes in the same environment by used the same recorded programming (sound forge 5.0) . The proposed technique has been testing by using different group from sound segments which recorded in the same environment and recorded program. The percentage of recognition reaches to 87% to all recorded phonemes

)ينادمم( ةببضملا ةيبصعلا ةكبشلا مدختسي يلاحلا ثحبلا ضعب زييمتل برعلا تامينوفلا هي ثيح ,يءامتنلاا ةمدختسملا ادئاز لادب دحاو نم امتنلاا لاود ددع ء عوفرم ة ددعل ةكبشلا تلاخدم ىلإ ةفاضإ .ةكبشلا بيردت نمز ليلقت , انمدختسا وا )هلع+حيحص(نيمينوف نم هنوكتملا هيتوصلا عطاقملا ضعبلاك نمو رامعلاا فلتخمب صخش نم رثكا لبق نم هلجسمو )حيحص + هلع + حيحص(تامينوف ثلاث ليجستلا جمانرب سفن مادختسابو هئيبلا سفنبو نيسنجلا sound forge 5.0 بيردتلل . رابتخا متةعومجم ىلع ةحرتقملا ةينقتلا ةفلتخم تافصاوملا سفنب هلجسمو تامينوفلا سفنل هيتوصلا عطاقملا نمزييمت ةبسن ىلع انلصح دقو ليجستلل مدختسملا جمانربلاو هئيبلاو 78 %

Listing 1 - 7 of 7
Sort by
Narrow your search

Resource type

article (7)


Language

English (5)

Arabic (1)


Year
From To Submit

2018 (1)

2016 (1)

2015 (1)

2014 (1)

2010 (1)

More...